batch-example-2/recipes/HO580_CHARGE.OXML

975 lines
32 KiB
Plaintext
Raw Permalink Normal View History

2023-11-20 21:08:07 +00:00
<?xml version="1.0" encoding="UTF-8"?>
<RecipeElement xmlns="urn:Rockwell/MasterRecipe" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="urn:Rockwell/MasterRecipe C:\PROGRA~1\ROCKWE~1\BATCH\SCHEMAS\MasterRecipe.xsd" SchemaVersion="3530">
<RecipeElementID>HO580_CHARGE</RecipeElementID>
<Header>
<Abstract/>
<ApprovedBy/>
<AreaModel>\\DESKTOP-PKHILQE\BATCHCTL\ZONE-10\EQUIPMENT-MODEL.CFG</AreaModel>
<AreaModelDate>1950-02-28T00:00:00</AreaModelDate>
<Author>GB</Author>
<BeingEditedBy>Not being handled yet</BeingEditedBy>
<ClassBased>false</ClassBased>
<DBSchema>3530</DBSchema>
<DefaultSize>0.</DefaultSize>
<Description/>
<Duration>0</Duration>
<LocaleID>-1</LocaleID>
<MaxSize>0.</MaxSize>
<MinSize>0.</MinSize>
<ProductCode/>
<ProductID>Generic</ProductID>
<ProductUnits/>
<RecipeType>Operation</RecipeType>
<Released>0</Released>
<ReleaseAsStep>true</ReleaseAsStep>
<Resource>HO580</Resource>
<VerificationDate>1950-02-28T00:00:00</VerificationDate>
<Version>1.1</Version>
<VersionDate>2023-07-12T14:31:14</VersionDate>
<Obsoleted>false</Obsoleted>
<NextWIPNumber>2</NextWIPNumber>
<VersionDescription/>
<ParentName/>
<ParentVersionDescription/>
<ParentVersionDate>1950-02-28T00:00:00</ParentVersionDate>
<ParentVerificationDate>1950-02-28T00:00:00</ParentVerificationDate>
<ParentAreaModelDate>1950-02-28T00:00:00</ParentAreaModelDate>
<ParentAreaModelName/>
<SecurityAuthorityIdentifier>NOT_AVAILABLE</SecurityAuthorityIdentifier>
</Header>
<Parameter>
<Name>DEHUMRH</Name>
<ERPAlias/>
<PLCReference>1</PLCReference>
<Real>0</Real>
<High>100</High>
<Low>0</Low>
<EngineeringUnits>%</EngineeringUnits>
<Scale>false</Scale>
</Parameter>
<Parameter>
<Name>DEHUMTEMP</Name>
<ERPAlias/>
<PLCReference>1</PLCReference>
<Real>0</Real>
<High>100</High>
<Low>0</Low>
<EngineeringUnits>degC</EngineeringUnits>
<Scale>false</Scale>
</Parameter>
<Parameter>
<Name>HUMIDITYATEND</Name>
<ERPAlias/>
<PLCReference>1</PLCReference>
<EnumerationSet>Y_N_NA</EnumerationSet>
<EnumerationMember>NO</EnumerationMember>
</Parameter>
<Parameter>
<Name>HUMIDITYATSTART</Name>
<ERPAlias/>
<PLCReference>1</PLCReference>
<EnumerationSet>Y_N_NA</EnumerationSet>
<EnumerationMember>NO</EnumerationMember>
</Parameter>
<Parameter>
<Name>KIND_OF_DOSING</Name>
<ERPAlias/>
<PLCReference>1</PLCReference>
<EnumerationSet>KIND_OF_DOSING</EnumerationSet>
<EnumerationMember>POSITIVE_WEIGHING_WITHOUT_BATCH_OPTIM</EnumerationMember>
</Parameter>
<Parameter>
<Name>MILL_SPEED</Name>
<ERPAlias/>
<PLCReference>1</PLCReference>
<Integer>0</Integer>
<High>1000</High>
<Low>0</Low>
<EngineeringUnits>%*10</EngineeringUnits>
<Scale>false</Scale>
</Parameter>
<Parameter>
<Name>ROTARY_SPEED</Name>
<ERPAlias/>
<PLCReference>1</PLCReference>
<Integer>0</Integer>
<High>1000</High>
<Low>0</Low>
<EngineeringUnits>%10</EngineeringUnits>
<Scale>false</Scale>
</Parameter>
<Parameter>
<Name>SUB_ASSEMBLY</Name>
<ERPAlias/>
<PLCReference>1</PLCReference>
<Integer>1</Integer>
<High>5</High>
<Low>1</Low>
<EngineeringUnits/>
<Scale>false</Scale>
</Parameter>
<Parameter>
<Name>SUB_BATCH_TOLERANCE</Name>
<ERPAlias/>
<PLCReference>1</PLCReference>
<Real>0</Real>
<High>100</High>
<Low>0</Low>
<EngineeringUnits/>
<Scale>false</Scale>
</Parameter>
<Parameter>
<Name>SUB_BATCH_WEIGHT</Name>
<ERPAlias/>
<PLCReference>1</PLCReference>
<Real>0</Real>
<High>1000</High>
<Low>0</Low>
<EngineeringUnits/>
<Scale>false</Scale>
</Parameter>
<Steps>
<InitialStep XPos="700" YPos="100">
<Name>INITIALSTEP:1</Name>
</InitialStep>
<TerminalStep XPos="800" YPos="5504">
<Name>TERMINALSTEP:1</Name>
</TerminalStep>
<Step XPos="600" YPos="4106" AcquireUnit="true" SystemStep="false">
<Name>$NULL:1</Name>
<StepRecipeID>$NULL</StepRecipeID>
<PackedFlags>257</PackedFlags>
<UnitAlias>HO580</UnitAlias>
</Step>
<Step XPos="600" YPos="700" AcquireUnit="true" SystemStep="false">
<Name>ACCUMULATOR:1</Name>
<StepRecipeID>ACCUMULATOR</StepRecipeID>
<PackedFlags>1</PackedFlags>
<UnitAlias>HO580</UnitAlias>
<FormulaValue>
<Name>ADD</Name>
<Display>false</Display>
<Value/>
<Real>1</Real>
<EngineeringUnits/>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>PROMPT</Name>
<Display>true</Display>
<Value/>
<String>TURN ON</String>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>RESET</Name>
<Display>false</Display>
<Value/>
<EnumerationSet>YES_NO</EnumerationSet>
<EnumerationMember>YES</EnumerationMember>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>USE_ACCUMULATOR</Name>
<Display>false</Display>
<Value/>
<EnumerationSet>ACCUMULATORS_ENUM</EnumerationSet>
<EnumerationMember>HUMIDITY_MONITORING</EnumerationMember>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<ReportLimit Verification="No_Limits">
<Name>ACCUMULATOR</Name>
<LowLowLowValue/>
<LowLowValue/>
<LowValue/>
<HighValue/>
<HighHighValue/>
<HighHighHighValue/>
<VerificationLimitCalculation>Absolute</VerificationLimitCalculation>
<TargetParameter/>
</ReportLimit>
</Step>
<Step XPos="1600" YPos="700" AcquireUnit="true" SystemStep="false">
<Name>ACCUMULATOR:2</Name>
<StepRecipeID>ACCUMULATOR</StepRecipeID>
<PackedFlags>1</PackedFlags>
<UnitAlias>HO580</UnitAlias>
<FormulaValue>
<Name>ADD</Name>
<Display>false</Display>
<Value/>
<Real>0</Real>
<EngineeringUnits/>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>PROMPT</Name>
<Display>false</Display>
<Value/>
<String>TURN OFF</String>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>RESET</Name>
<Display>false</Display>
<Value/>
<EnumerationSet>YES_NO</EnumerationSet>
<EnumerationMember>YES</EnumerationMember>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>USE_ACCUMULATOR</Name>
<Display>false</Display>
<Value/>
<EnumerationSet>ACCUMULATORS_ENUM</EnumerationSet>
<EnumerationMember>HUMIDITY_MONITORING</EnumerationMember>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<ReportLimit Verification="No_Limits">
<Name>ACCUMULATOR</Name>
<LowLowLowValue/>
<LowLowValue/>
<LowValue/>
<HighValue/>
<HighHighValue/>
<HighHighHighValue/>
<VerificationLimitCalculation>Absolute</VerificationLimitCalculation>
<TargetParameter/>
</ReportLimit>
</Step>
<Step XPos="600" YPos="4720" AcquireUnit="true" SystemStep="false">
<Name>ACCUMULATOR:3</Name>
<StepRecipeID>ACCUMULATOR</StepRecipeID>
<PackedFlags>1</PackedFlags>
<UnitAlias>HO580</UnitAlias>
<FormulaValue>
<Name>ADD</Name>
<Display>false</Display>
<Value/>
<Real>1</Real>
<EngineeringUnits/>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>PROMPT</Name>
<Display>true</Display>
<Value/>
<String>TURN ON</String>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>RESET</Name>
<Display>false</Display>
<Value/>
<EnumerationSet>YES_NO</EnumerationSet>
<EnumerationMember>YES</EnumerationMember>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>USE_ACCUMULATOR</Name>
<Display>false</Display>
<Value/>
<EnumerationSet>ACCUMULATORS_ENUM</EnumerationSet>
<EnumerationMember>HUMIDITY_MONITORING</EnumerationMember>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<ReportLimit Verification="No_Limits">
<Name>ACCUMULATOR</Name>
<LowLowLowValue/>
<LowLowValue/>
<LowValue/>
<HighValue/>
<HighHighValue/>
<HighHighHighValue/>
<VerificationLimitCalculation>Absolute</VerificationLimitCalculation>
<TargetParameter/>
</ReportLimit>
</Step>
<Step XPos="1800" YPos="4704" AcquireUnit="true" SystemStep="false">
<Name>ACCUMULATOR:4</Name>
<StepRecipeID>ACCUMULATOR</StepRecipeID>
<PackedFlags>1</PackedFlags>
<UnitAlias>HO580</UnitAlias>
<FormulaValue>
<Name>ADD</Name>
<Display>false</Display>
<Value/>
<Real>0</Real>
<EngineeringUnits/>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>PROMPT</Name>
<Display>true</Display>
<Value/>
<String>TURN OFF</String>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>RESET</Name>
<Display>false</Display>
<Value/>
<EnumerationSet>YES_NO</EnumerationSet>
<EnumerationMember>YES</EnumerationMember>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>USE_ACCUMULATOR</Name>
<Display>false</Display>
<Value/>
<EnumerationSet>ACCUMULATORS_ENUM</EnumerationSet>
<EnumerationMember>HUMIDITY_MONITORING</EnumerationMember>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<ReportLimit Verification="No_Limits">
<Name>ACCUMULATOR</Name>
<LowLowLowValue/>
<LowLowValue/>
<LowValue/>
<HighValue/>
<HighHighValue/>
<HighHighHighValue/>
<VerificationLimitCalculation>Absolute</VerificationLimitCalculation>
<TargetParameter/>
</ReportLimit>
</Step>
<Step XPos="600" YPos="1900" AcquireUnit="true" SystemStep="false">
<Name>CHARGE:1</Name>
<StepRecipeID>CHARGE</StepRecipeID>
<PackedFlags>1</PackedFlags>
<UnitAlias>HO580</UnitAlias>
<FormulaValue>
<Name>FINE_VALUE</Name>
<Display>false</Display>
<Value/>
<Real>0</Real>
<EngineeringUnits/>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>HEEL</Name>
<Display>false</Display>
<Value/>
<Real>20</Real>
<EngineeringUnits/>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>HEEL_TIME</Name>
<Display>false</Display>
<Value/>
<Integer>100</Integer>
<EngineeringUnits/>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>KIND_OF_DOSING</Name>
<Display>false</Display>
<Defer>KIND_OF_DOSING</Defer>
<EnumerationSet>KIND_OF_DOSING</EnumerationSet>
<EnumerationMember/>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>SPEED_COARSE</Name>
<Display>false</Display>
<Defer>MILL_SPEED</Defer>
<Integer>0</Integer>
<EngineeringUnits>%*10</EngineeringUnits>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>SPEED_FINE</Name>
<Display>false</Display>
<Defer>ROTARY_SPEED</Defer>
<Integer>0</Integer>
<EngineeringUnits>%10</EngineeringUnits>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>SUB_ASSEMBLY</Name>
<Display>false</Display>
<Defer>SUB_ASSEMBLY</Defer>
<Integer>0</Integer>
<EngineeringUnits/>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>TARGET_VALUE_DOSING_TIME</Name>
<Display>false</Display>
<Value/>
<Integer>1200</Integer>
<EngineeringUnits/>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>TOLERANCE</Name>
<Display>false</Display>
<Defer>SUB_BATCH_TOLERANCE</Defer>
<Real>0.0</Real>
<EngineeringUnits/>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>WEIGHT_TO_ADD</Name>
<Display>false</Display>
<Defer>SUB_BATCH_WEIGHT</Defer>
<Real>0.0</Real>
<EngineeringUnits/>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<ReportLimit Verification="No_Limits">
<Name>END_WEIGHT</Name>
<LowLowLowValue/>
<LowLowValue/>
<LowValue/>
<HighValue/>
<HighHighValue/>
<HighHighHighValue/>
<VerificationLimitCalculation>Absolute</VerificationLimitCalculation>
<TargetParameter/>
</ReportLimit>
<ReportLimit Verification="No_Limits">
<Name>READY_TO_COMPLETE</Name>
<LowLowLowValue/>
<LowLowValue/>
<LowValue/>
<HighValue/>
<HighHighValue/>
<HighHighHighValue/>
<VerificationLimitCalculation>Absolute</VerificationLimitCalculation>
<TargetParameter/>
</ReportLimit>
<ReportLimit Verification="No_Limits">
<Name>START_WEIGHT</Name>
<LowLowLowValue/>
<LowLowValue/>
<LowValue/>
<HighValue/>
<HighHighValue/>
<HighHighHighValue/>
<VerificationLimitCalculation>Absolute</VerificationLimitCalculation>
<TargetParameter/>
</ReportLimit>
<ReportLimit Verification="No_Limits">
<Name>WEIGHT_ADDED</Name>
<LowLowLowValue/>
<LowLowValue/>
<LowValue/>
<HighValue/>
<HighHighValue/>
<HighHighHighValue/>
<VerificationLimitCalculation>Absolute</VerificationLimitCalculation>
<TargetParameter/>
</ReportLimit>
</Step>
<Step XPos="1400" YPos="2400" AcquireUnit="true" SystemStep="false">
<Name>EP_PROMPT:1</Name>
<StepRecipeID>EP_PROMPT</StepRecipeID>
<PackedFlags>1</PackedFlags>
<UnitAlias>HO580</UnitAlias>
<FormulaValue>
<Name>PROMPT</Name>
<Display>true</Display>
<Value/>
<String>CONFIRM WEIGHT IN HO580 IS WITHIN TOLERANCE</String>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
</Step>
<Step XPos="600" YPos="1300" AcquireUnit="true" SystemStep="false">
<Name>PARTNER_RECEIVE:1</Name>
<StepRecipeID>PARTNER_RECEIVE</StepRecipeID>
<PackedFlags>1</PackedFlags>
<UnitAlias>HO580</UnitAlias>
<FormulaValue>
<Name>REASON</Name>
<Display>true</Display>
<Value/>
<String>WAIT FOR HO561 TO BE READY TO DISCHARGE</String>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
</Step>
<Step XPos="1400" YPos="2906" AcquireUnit="true" SystemStep="false">
<Name>PARTNER_RECEIVE:2</Name>
<StepRecipeID>PARTNER_RECEIVE</StepRecipeID>
<PackedFlags>1</PackedFlags>
<UnitAlias>HO580</UnitAlias>
<FormulaValue>
<Name>REASON</Name>
<Display>true</Display>
<Value/>
<String>WAIT FOR HO561 DISCHARGE COMPLETE CONFIRMATION</String>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
</Step>
<Step XPos="1400" YPos="3406" AcquireUnit="true" SystemStep="false">
<Name>PARTNER_RECEIVE:3</Name>
<StepRecipeID>PARTNER_RECEIVE</StepRecipeID>
<PackedFlags>1</PackedFlags>
<UnitAlias>HO580</UnitAlias>
<FormulaValue>
<Name>REASON</Name>
<Display>true</Display>
<Value/>
<String>CHARGE COMPLETE INTO HO580</String>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
</Step>
<Step XPos="1400" YPos="1900" AcquireUnit="true" SystemStep="false">
<Name>TIMER:1</Name>
<StepRecipeID>$TIMER_DN_SECOND</StepRecipeID>
<PackedFlags>513</PackedFlags>
<UnitAlias>HO580</UnitAlias>
<FormulaValue>
<Name>$HOLD_BEHAVIOR</Name>
<Display>false</Display>
<Value/>
<EnumerationSet>$HOLD_BEHAVIOR</EnumerationSet>
<EnumerationMember>RETENTIVE</EnumerationMember>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>$SETPOINT</Name>
<Display>false</Display>
<Value/>
<Real>1000</Real>
<EngineeringUnits/>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<FormulaValue>
<Name>$TIMER_TYPE</Name>
<Display>false</Display>
<Value/>
<EnumerationSet>$TIMER_TYPE</EnumerationSet>
<EnumerationMember>COUNT_DOWN</EnumerationMember>
<FormulaValueLimit Verification="No_Limits">
<LowLowLowValue>0.</LowLowLowValue>
<LowLowValue>0.</LowLowValue>
<LowValue>0.</LowValue>
<HighValue>0.</HighValue>
<HighHighValue>0.</HighHighValue>
<HighHighHighValue>0.</HighHighHighValue>
</FormulaValueLimit>
</FormulaValue>
<ReportLimit Verification="No_Limits">
<Name>$ELAPSED_TIME</Name>
<LowLowLowValue/>
<LowLowValue/>
<LowValue/>
<HighValue/>
<HighHighValue/>
<HighHighHighValue/>
<VerificationLimitCalculation>Absolute</VerificationLimitCalculation>
<TargetParameter/>
</ReportLimit>
<ReportLimit Verification="No_Limits">
<Name>$REMAINING_TIME</Name>
<LowLowLowValue/>
<LowLowValue/>
<LowValue/>
<HighValue/>
<HighHighValue/>
<HighHighHighValue/>
<VerificationLimitCalculation>Absolute</VerificationLimitCalculation>
<TargetParameter/>
</ReportLimit>
</Step>
</Steps>
<Transition XPos="800" YPos="500">
<Name>T1</Name>
<ConditionalExpression>HUMIDITYATSTART = "YES"</ConditionalExpression>
</Transition>
<Transition XPos="800" YPos="4500">
<Name>T2</Name>
<ConditionalExpression>$NULL:1.[21] = [14] [3] HUMIDITYATEND = "YES"</ConditionalExpression>
</Transition>
<Transition XPos="800" YPos="996">
<Name>T3</Name>
<ConditionalExpression>ACCUMULATOR:1.[21] = [14]</ConditionalExpression>
</Transition>
<Transition XPos="800" YPos="5100">
<Name>T4</Name>
<ConditionalExpression>ACCUMULATOR:3.[21] = [14]</ConditionalExpression>
</Transition>
<Transition XPos="1796" YPos="452">
<Name>T5</Name>
<ConditionalExpression>HUMIDITYATSTART &lt;&gt; "YES"</ConditionalExpression>
</Transition>
<Transition XPos="1800" YPos="998">
<Name>T6</Name>
<ConditionalExpression>ACCUMULATOR:2.[21] = [14]</ConditionalExpression>
</Transition>
<Transition XPos="2000" YPos="4600">
<Name>T7</Name>
<ConditionalExpression>$NULL:1.[21] = [14] [3] HUMIDITYATEND &lt;&gt; "YES"</ConditionalExpression>
</Transition>
<Transition XPos="2000" YPos="5100">
<Name>T8</Name>
<ConditionalExpression>ACCUMULATOR:4.[21] = [14]</ConditionalExpression>
</Transition>
<Transition XPos="1600" YPos="3202">
<Name>T9</Name>
<ConditionalExpression>PARTNER_RECEIVE:2.[21] = [14]</ConditionalExpression>
</Transition>
<Transition XPos="800" YPos="1600">
<Name>T11</Name>
<ConditionalExpression>PARTNER_RECEIVE:1.[21] = [14]</ConditionalExpression>
</Transition>
<Transition XPos="1600" YPos="2200">
<Name>T14</Name>
<ConditionalExpression>(SUB_BATCH_WEIGHT &gt;= 200 [2] TIMER:1.REMAINING_TIME = 0) [3] CHARGE:1.[21] = [12] [3] CHARGE:1.READY_TO_COMPLETE = "YES"</ConditionalExpression>
</Transition>
<Transition XPos="1600" YPos="2702">
<Name>T15</Name>
<ConditionalExpression>EP_PROMPT:1.[21] = [14]</ConditionalExpression>
</Transition>
<Transition XPos="800" YPos="3900">
<Name>T16</Name>
<ConditionalExpression>PARTNER_RECEIVE:3.[21] = [14]</ConditionalExpression>
</Transition>
<ElementLink>
<FromStep>$NULL:1</FromStep>
<ToTransition>T2</ToTransition>
</ElementLink>
<ElementLink>
<FromStep>$NULL:1</FromStep>
<ToTransition>T7</ToTransition>
</ElementLink>
<ElementLink>
<FromTransition>T16</FromTransition>
<ToStep>$NULL:1</ToStep>
</ElementLink>
<ElementLink>
<FromTransition>T1</FromTransition>
<ToStep>ACCUMULATOR:1</ToStep>
</ElementLink>
<ElementLink>
<FromStep>ACCUMULATOR:1</FromStep>
<ToTransition>T3</ToTransition>
</ElementLink>
<ElementLink>
<FromTransition>T5</FromTransition>
<ToStep>ACCUMULATOR:2</ToStep>
</ElementLink>
<ElementLink>
<FromStep>ACCUMULATOR:2</FromStep>
<ToTransition>T6</ToTransition>
</ElementLink>
<ElementLink>
<FromTransition>T2</FromTransition>
<ToStep>ACCUMULATOR:3</ToStep>
</ElementLink>
<ElementLink>
<FromStep>ACCUMULATOR:3</FromStep>
<ToTransition>T4</ToTransition>
</ElementLink>
<ElementLink>
<FromTransition>T7</FromTransition>
<ToStep>ACCUMULATOR:4</ToStep>
</ElementLink>
<ElementLink>
<FromStep>ACCUMULATOR:4</FromStep>
<ToTransition>T8</ToTransition>
</ElementLink>
<ElementLink>
<FromTransition>T11</FromTransition>
<ToStep>CHARGE:1</ToStep>
</ElementLink>
<ElementLink>
<FromStep>CHARGE:1</FromStep>
<ToTransition>T16</ToTransition>
</ElementLink>
<ElementLink>
<FromTransition>T14</FromTransition>
<ToStep>EP_PROMPT:1</ToStep>
</ElementLink>
<ElementLink>
<FromStep>EP_PROMPT:1</FromStep>
<ToTransition>T15</ToTransition>
</ElementLink>
<ElementLink>
<FromStep>INITIALSTEP:1</FromStep>
<ToTransition>T1</ToTransition>
</ElementLink>
<ElementLink>
<FromStep>INITIALSTEP:1</FromStep>
<ToTransition>T5</ToTransition>
</ElementLink>
<ElementLink>
<FromTransition>T3</FromTransition>
<ToStep>PARTNER_RECEIVE:1</ToStep>
</ElementLink>
<ElementLink>
<FromTransition>T6</FromTransition>
<ToStep>PARTNER_RECEIVE:1</ToStep>
</ElementLink>
<ElementLink>
<FromStep>PARTNER_RECEIVE:1</FromStep>
<ToTransition>T11</ToTransition>
</ElementLink>
<ElementLink>
<FromStep>PARTNER_RECEIVE:2</FromStep>
<ToTransition>T9</ToTransition>
</ElementLink>
<ElementLink>
<FromTransition>T15</FromTransition>
<ToStep>PARTNER_RECEIVE:2</ToStep>
</ElementLink>
<ElementLink>
<FromTransition>T9</FromTransition>
<ToStep>PARTNER_RECEIVE:3</ToStep>
</ElementLink>
<ElementLink>
<FromStep>PARTNER_RECEIVE:3</FromStep>
<ToTransition>T16</ToTransition>
</ElementLink>
<ElementLink>
<FromTransition>T4</FromTransition>
<ToStep>TERMINALSTEP:1</ToStep>
</ElementLink>
<ElementLink>
<FromTransition>T8</FromTransition>
<ToStep>TERMINALSTEP:1</ToStep>
</ElementLink>
<ElementLink>
<FromTransition>T11</FromTransition>
<ToStep>TIMER:1</ToStep>
</ElementLink>
<ElementLink>
<FromStep>TIMER:1</FromStep>
<ToTransition>T14</ToTransition>
</ElementLink>
<UnitRequirement>
<UnitAlias>HO580</UnitAlias>
<ClassInstance>HO580</ClassInstance>
<BindingMethod>BatchCreation</BindingMethod>
<MaterialBindingMethod>ByInventory</MaterialBindingMethod>
<ClassBased>false</ClassBased>
</UnitRequirement>
<Comments/>
<Formulations/>
</RecipeElement>