15936 lines
524 KiB
Plaintext
15936 lines
524 KiB
Plaintext
|
PB 3 -PB3 FAULT EVALUATION C:ZONE10ST.S5D LEN=625
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
:C -DB96 OUTPUTS SERVICE M.
|
|||
|
:A D 3.11 Servicemode: FC acknowledge A6.3
|
|||
|
:= F 200.0 Servicemode: FC acknowledge A6.3
|
|||
|
:
|
|||
|
:A D 3.2 Servicemode: FC acknowledge A7.2
|
|||
|
:= F 200.1 Servicemode: FC acknowledge A7.2
|
|||
|
:
|
|||
|
:A D 4.13 Servicemode: FC acknowledge A8.5
|
|||
|
:= F 200.2 Servicemode: FC acknowledge A8.5
|
|||
|
:
|
|||
|
:A D 4.12 Servidemode: FC acknowledge A8.4
|
|||
|
:= F 200.3 Servicemode: FC acknowledge A8.4
|
|||
|
: *(5)
|
|||
|
:A D 5.10 *(5) Servicemode: FC ackn. A10.2
|
|||
|
:= F 200.4 *(5) Servicemode: FC ackn. A10.2
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
DB 96 = DB96 OUTPUTS SERVICE M. outputs service mode from RSView
|
|||
|
|
|||
|
Segment 2
|
|||
|
:C -DB100 FAULT EVALUATION
|
|||
|
:
|
|||
|
:A D 195.10 ackn fault S6.2
|
|||
|
:AN -M 4.2 GLOB.SERVICE-MODE
|
|||
|
:O F 200.0 Servicemode: FC acknowledge A6.3
|
|||
|
:= -A 6.3=z10+b1.HO500-fco
|
|||
|
:
|
|||
|
:A D 195.10 ackn fault S6.2
|
|||
|
:A D 67.10 cause fault S6.2
|
|||
|
:R D 195.10 ackn fault S6.2
|
|||
|
:
|
|||
|
:A D 195.1 ackn fault S7.1
|
|||
|
:AN -M 4.2 GLOB.SERVICE-MODE
|
|||
|
:O F 200.1 Servicemode: FC acknowledge A7.2
|
|||
|
:= -A 7.2=z10+b3.DR540-fco
|
|||
|
:
|
|||
|
:A D 195.1 ackn fault S7.1
|
|||
|
:A D 67.1 cause fault S7.1
|
|||
|
:R D 195.1 ackn fault S7.1
|
|||
|
:***
|
|||
|
|
|||
|
F 4.2 = M 4.2 GLOB.SERVICE-MODE
|
|||
|
Q 6.3 = A 6.3=z10+b1.HO500-fco frequ.converter acknowledge HO 500
|
|||
|
Q 7.2 = A 7.2=z10+b3.DR540-fco frequ.converter acknowledge DR 540
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
Segment 3
|
|||
|
:A D 196.9 ackn fault S8.1
|
|||
|
:AN -M 4.2 GLOB.SERVICE-MODE
|
|||
|
:O F 200.3 Servicemode: FC acknowledge A8.4
|
|||
|
:= -A 8.4=z10+b3.MI583-fco
|
|||
|
:
|
|||
|
:A D 196.9 ackn fault S8.1
|
|||
|
:A D 68.9 cause fault S8.1
|
|||
|
:R D 196.9 ackn fault S8.1
|
|||
|
:
|
|||
|
:A D 196.15 ackn fault S8.7
|
|||
|
:AN -M 4.2 GLOB.SERVICE-MODE
|
|||
|
:O F 200.2 Servicemode: FC acknowledge A8.5
|
|||
|
:= -A 8.5=z10+b3.MI583-fco
|
|||
|
:
|
|||
|
PB 3 -PB3 FAULT EVALUATION C:ZONE10ST.S5D LEN=625
|
|||
|
Page 2
|
|||
|
:A D 196.15 ackn fault S8.7
|
|||
|
:A D 68.15 cause fault S8.7
|
|||
|
:R D 196.15 ackn fault S8.7
|
|||
|
:***
|
|||
|
|
|||
|
F 4.2 = M 4.2 GLOB.SERVICE-MODE
|
|||
|
Q 8.4 = A 8.4=z10+b3.MI583-fco frequ.converter FE acknowledge MI 583
|
|||
|
Q 8.5 = A 8.5=z10+b3.MI583-fco frequ.converter MI acknowledge MI 583
|
|||
|
|
|||
|
Segment 4 *(5)
|
|||
|
:A D 197.9 ackn fault S10.1
|
|||
|
:AN -M 4.2 GLOB.SERVICE-MODE
|
|||
|
:O F 200.4 Servicemode: FC acknowled. A10.1
|
|||
|
:= -A 10.2=z10+b3.BD560-fco *(5) Total network inserted!
|
|||
|
:
|
|||
|
:A D 197.9 ackn fault S10.1
|
|||
|
:A D 69.9 cause fault S10.1
|
|||
|
:R D 197.9 ackn fault S10.1
|
|||
|
:***
|
|||
|
|
|||
|
F 4.2 = M 4.2 GLOB.SERVICE-MODE
|
|||
|
Q 10.2 = A 10.2=z10+b3.BD560-fco frequ.converter acknowledge BD 560 *(5)
|
|||
|
|
|||
|
Segment 5 fault evaluation
|
|||
|
:A -E 22.1=z10.PLC-flt:on
|
|||
|
:= -M 9.6 FAULT FUSE
|
|||
|
:
|
|||
|
:AN -M 1.1 CONTROL VOLTAGE
|
|||
|
:= -M 9.7 CONTR_VOLTAGE OFF
|
|||
|
:***
|
|||
|
|
|||
|
I 22.1 = E 22.1=z10.PLC-flt:on fault fuse on PLC
|
|||
|
F 9.6 = M 9.6 FAULT FUSE PLC-fault
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
F 9.7 = M 9.7 CONTR_VOLTAGE OFF PLC-fault
|
|||
|
|
|||
|
Segment 6 plc faults DW 00
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS BI
|
|||
|
IMP : -M 0.7 FLT.EVAL. FAST
|
|||
|
AW1 : -MW 8 ERROR-OB'S
|
|||
|
AW2 : FW 200
|
|||
|
EW1 : FW 200
|
|||
|
EW2 : FW 200
|
|||
|
FILT : KM 11111111 11111111
|
|||
|
DW1 : KF +0
|
|||
|
DW2 : KF +0
|
|||
|
FRG : -M 0.1 CONSTANT 1 always
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
F 0.7 = M 0.7 FLT.EVAL. FAST
|
|||
|
FW 8 = MW 8 ERROR-OB'S
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
PB 3 -PB3 FAULT EVALUATION C:ZONE10ST.S5D LEN=625
|
|||
|
Page 3
|
|||
|
Segment 7 special faults DW 01
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS BI
|
|||
|
IMP : -M 0.7 FLT.EVAL. FAST
|
|||
|
AW1 : -MW 40 SCALE FAULTS
|
|||
|
AW2 : FW 200
|
|||
|
EW1 : FW 200
|
|||
|
EW2 : FW 200
|
|||
|
FILT : KM 01111111 00000111 *(5) M40.3-.6
|
|||
|
DW1 : KF +1
|
|||
|
DW2 : KF +1
|
|||
|
FRG : -M 0.1 CONSTANT 1 always
|
|||
|
QUIT : KM 00000111 00000111 *(5) M40.3-.6 no quitt
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
F 0.7 = M 0.7 FLT.EVAL. FAST
|
|||
|
FW 40 = MW 40 SCALE FAULTS
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 8 motor faults DW 02
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS MO
|
|||
|
IMP : -M 0.7 FLT.EVAL. FAST
|
|||
|
AW1 : QW 4
|
|||
|
AW2 : FW 200
|
|||
|
EW1 : IW 4
|
|||
|
EW2 : FW 200
|
|||
|
FILT : KM 00010111 00011111
|
|||
|
DW1 : KF +2
|
|||
|
DW2 : KF +2
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
F 0.7 = M 0.7 FLT.EVAL. FAST
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 9 motor faults DW 03
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS MO
|
|||
|
IMP : -M 0.7 FLT.EVAL. FAST
|
|||
|
AW1 : QW 6
|
|||
|
AW2 : FW 200
|
|||
|
EW1 : IW 6
|
|||
|
EW2 : FW 200
|
|||
|
PB 3 -PB3 FAULT EVALUATION C:ZONE10ST.S5D LEN=625
|
|||
|
Page 4
|
|||
|
FILT : KM 10010011 11100001
|
|||
|
DW1 : KF +3
|
|||
|
DW2 : KF +3
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
F 0.7 = M 0.7 FLT.EVAL. FAST
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 10 FC faults DW 03
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS BN
|
|||
|
IMP : -M 0.7 FLT.EVAL. FAST
|
|||
|
AW1 : IW 6
|
|||
|
AW2 : FW 200
|
|||
|
EW1 : FW 200
|
|||
|
EW2 : FW 200
|
|||
|
FILT : KM 00000100 00000010
|
|||
|
DW1 : KF +3
|
|||
|
DW2 : KF +3
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
F 0.7 = M 0.7 FLT.EVAL. FAST
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 11 FC faults DW 04
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS BN
|
|||
|
IMP : -M 0.7 FLT.EVAL. FAST
|
|||
|
AW1 : IW 8
|
|||
|
AW2 : FW 200
|
|||
|
EW1 : FW 200
|
|||
|
EW2 : FW 200
|
|||
|
FILT : KM 10000010 00000000
|
|||
|
DW1 : KF +4
|
|||
|
DW2 : KF +4
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
PB 3 -PB3 FAULT EVALUATION C:ZONE10ST.S5D LEN=625
|
|||
|
Page 5
|
|||
|
F 0.7 = M 0.7 FLT.EVAL. FAST
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 12 motor faults DW 04
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS MO
|
|||
|
IMP : -M 1.0 FLT.EVAL. SLOW
|
|||
|
AW1 : QW 8
|
|||
|
AW2 : FW 200
|
|||
|
EW1 : IW 8
|
|||
|
EW2 : FW 200
|
|||
|
FILT : KM 00000101 00111111
|
|||
|
DW1 : KF +4
|
|||
|
DW2 : KF +4
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
F 1.0 = M 1.0 FLT.EVAL. SLOW
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 13 special faults DW 4
|
|||
|
:L IW 8
|
|||
|
:T FW 202
|
|||
|
:
|
|||
|
:AN -E 8.3=z10+b3.MI583-com
|
|||
|
:= F 202.3 cone mill unlocked
|
|||
|
:
|
|||
|
:AN -E 8.4=z10+b3.MI5X3-sac
|
|||
|
:= F 202.4 emergency stop cone mill
|
|||
|
:
|
|||
|
:CX -DX201 PL6-10HO561,BD560
|
|||
|
:L DW 226
|
|||
|
:L KF +4
|
|||
|
:!=F
|
|||
|
:= F 210.0 hammer mill requested
|
|||
|
:
|
|||
|
:L DW 226
|
|||
|
:L KF +1
|
|||
|
:!=F
|
|||
|
:AN -E 8.5=z10+b3.MI583-com
|
|||
|
:O(
|
|||
|
:L DW 226 01
|
|||
|
:L KF +1 01
|
|||
|
:><F 01
|
|||
|
:AN F 210.0 01 hammer mill requested
|
|||
|
:A -E 8.5=z10+b3.MI583-com 01
|
|||
|
:) 01
|
|||
|
:A -A 7.5=z10+b3.HO584-vac
|
|||
|
:= F 202.5
|
|||
|
:
|
|||
|
PB 3 -PB3 FAULT EVALUATION C:ZONE10ST.S5D LEN=625
|
|||
|
Page 6
|
|||
|
:L DW 226
|
|||
|
:L KF +2
|
|||
|
:!=F
|
|||
|
:AN -E 8.6=z10+b3.MI583-com
|
|||
|
:O(
|
|||
|
:L DW 226 01
|
|||
|
:L KF +2 01
|
|||
|
:><F 01
|
|||
|
:AN F 210.0 01 hammer mill requested
|
|||
|
:A -E 8.6=z10+b3.MI583-com 01
|
|||
|
:) 01
|
|||
|
:A -A 7.5=z10+b3.HO584-vac
|
|||
|
:= F 202.6
|
|||
|
:
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS BI
|
|||
|
IMP : -M 0.7 FLT.EVAL. FAST
|
|||
|
AW1 : FW 202
|
|||
|
AW2 : FW 200
|
|||
|
EW1 : FW 200
|
|||
|
EW2 : FW 200
|
|||
|
FILT : KM 01111000 00000000
|
|||
|
DW1 : KF +4
|
|||
|
DW2 : KF +4
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 204.0
|
|||
|
AEND : F 204.0
|
|||
|
:***
|
|||
|
|
|||
|
I 8.3 = E 8.3=z10+b3.MI583-com cone mill locked MI 583
|
|||
|
I 8.4 = E 8.4=z10+b3.MI5X3-sac safety circuit all healthy MI 5X3 *(6)
|
|||
|
I 8.5 = E 8.5=z10+b3.MI583-com cone mill sieve A MI 583
|
|||
|
Q 7.5 = A 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
I 8.6 = E 8.6=z10+b3.MI583-com cone mill sieve B MI 583
|
|||
|
F 0.7 = M 0.7 FLT.EVAL. FAST
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
DX 201 = DX201 PL6-10HO561,BD560 PL6:RES PL7-9:UNIT HO561 PL10:UNIT BD560
|
|||
|
|
|||
|
Segment 14 FC faults DW 05 *(5)
|
|||
|
:L IW 10 *(6)
|
|||
|
:T FW 204 *(6)
|
|||
|
:
|
|||
|
:AN -M 60.0 STRT CHARG BD560 *(6)
|
|||
|
:AN -M 60.2 STRT BLEND BD560 *(6)
|
|||
|
:AN -M 62.1 STRT DINOP BD560 *(6)
|
|||
|
:AN -M 60.4 STRT DISCH.BD560 *(6)
|
|||
|
:AN -M 4.2 GLOB.SERVICE-MODE *(6)
|
|||
|
:O -E 10.2=z10+b3.BD560-sac *(6)
|
|||
|
:= F 204.2 *(6)
|
|||
|
:
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q *(5) Total network inserted !
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS BN
|
|||
|
IMP : -M 0.7 FLT.EVAL. FAST
|
|||
|
AW1 : FW 204 *(6)
|
|||
|
PB 3 -PB3 FAULT EVALUATION C:ZONE10ST.S5D LEN=625
|
|||
|
Page 7
|
|||
|
AW2 : FW 200
|
|||
|
EW1 : FW 200
|
|||
|
EW2 : FW 200
|
|||
|
FILT : KM 00000110 00000000 *(6)
|
|||
|
DW1 : KF +5
|
|||
|
DW2 : KF +5
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
F 60.0 = M 60.0 STRT CHARG BD560
|
|||
|
F 60.2 = M 60.2 STRT BLEND BD560
|
|||
|
F 62.1 = M 62.1 STRT DINOP BD560
|
|||
|
F 60.4 = M 60.4 STRT DISCH.BD560
|
|||
|
F 4.2 = M 4.2 GLOB.SERVICE-MODE
|
|||
|
I 10.2 = E 10.2=z10+b3.BD560-sac safety circuit all healthy BD 560 *(6)
|
|||
|
F 0.7 = M 0.7 FLT.EVAL. FAST
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 15 motor faults DW 05
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS MO
|
|||
|
IMP : -M 1.0 FLT.EVAL. SLOW
|
|||
|
AW1 : QW 10
|
|||
|
AW2 : FW 200
|
|||
|
EW1 : IW 10
|
|||
|
EW2 : FW 200
|
|||
|
FILT : KM 00000001 00001000 e11.3 cone screw open
|
|||
|
DW1 : KF +5
|
|||
|
DW2 : KF +5
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
F 1.0 = M 1.0 FLT.EVAL. SLOW
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 16 flap (2O/2I) faults DW 05/07
|
|||
|
:L IW 10 *(6)
|
|||
|
:T FW 200 *(6)
|
|||
|
:L IW 14 *(6)
|
|||
|
:T FW 204 *(6)
|
|||
|
:
|
|||
|
:A -E 10.2=z10+b3.BD560-sac *(6)
|
|||
|
:A -E 11.1=z10+b3.BD560-o2: *(6)
|
|||
|
:= F 201.1 *(6)
|
|||
|
:
|
|||
|
PB 3 -PB3 FAULT EVALUATION C:ZONE10ST.S5D LEN=625
|
|||
|
Page 8
|
|||
|
:ON -E 10.2=z10+b3.BD560-sac *(6)
|
|||
|
:O -E 15.1=z10+b3.BD560-o2: *(6)
|
|||
|
:= F 205.1 *(6)
|
|||
|
:
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS RW
|
|||
|
IMP : -M 1.0 FLT.EVAL. SLOW
|
|||
|
AW1 : QW 10
|
|||
|
AW2 : QW 14
|
|||
|
EW1 : FW 200 *(6)
|
|||
|
EW2 : FW 204 *(6)
|
|||
|
FILT : KM 00000000 00000010
|
|||
|
DW1 : KF +5
|
|||
|
DW2 : KF +7
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +2
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
I 10.2 = E 10.2=z10+b3.BD560-sac safety circuit all healthy BD 560 *(6)
|
|||
|
I 11.1 = E 11.1=z10+b3.BD560-o2: outletflap 2O2I open BD 560
|
|||
|
I 15.1 = E 15.1=z10+b3.BD560-o2: outletflap 2O2I closed BD 560
|
|||
|
F 1.0 = M 1.0 FLT.EVAL. SLOW
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 17 flap (1O/2I) faults DW 05/07
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS KL
|
|||
|
IMP : -M 1.0 FLT.EVAL. SLOW
|
|||
|
AW1 : QW 10
|
|||
|
AW2 : FW 200
|
|||
|
EW1 : IW 10
|
|||
|
EW2 : IW 14
|
|||
|
FILT : KM 00000000 01110100 *(2) E11.2,E15.2
|
|||
|
DW1 : KF +5
|
|||
|
DW2 : KF +7
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +2
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 204.0
|
|||
|
AEND : F 204.0
|
|||
|
:***
|
|||
|
|
|||
|
F 1.0 = M 1.0 FLT.EVAL. SLOW
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 18 *(1) flap (2O/2I) faults DW06/08
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q *(1) Total network inserted
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS RW
|
|||
|
PB 3 -PB3 FAULT EVALUATION C:ZONE10ST.S5D LEN=625
|
|||
|
Page 9
|
|||
|
IMP : -M 6.6 ONE_SHOT 10_sec *(6)
|
|||
|
AW1 : QW 12
|
|||
|
AW2 : QW 16
|
|||
|
EW1 : IW 12
|
|||
|
EW2 : IW 16
|
|||
|
FILT : KM 00000001 00000000
|
|||
|
DW1 : KF +6
|
|||
|
DW2 : KF +8
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +2
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
F 6.6 = M 6.6 ONE_SHOT 10_sec flashpulse 10 sec
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 19 flap (1O/2I) faults DW 06/08
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS KL
|
|||
|
IMP : -M 1.0 FLT.EVAL. SLOW
|
|||
|
AW1 : QW 12
|
|||
|
AW2 : FW 200
|
|||
|
EW1 : IW 12
|
|||
|
EW2 : IW 16
|
|||
|
FILT : KM 10111010 01111011 *(2) E13.1,E17.1
|
|||
|
DW1 : KF +6
|
|||
|
DW2 : KF +8
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +2
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
F 1.0 = M 1.0 FLT.EVAL. SLOW
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 20 pinch valve (1O/1I) faults DW 07
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS QV
|
|||
|
IMP : -M 1.0 FLT.EVAL. SLOW
|
|||
|
AW1 : QW 14
|
|||
|
AW2 : FW 200
|
|||
|
EW1 : FW 200
|
|||
|
EW2 : IW 14
|
|||
|
FILT : KM 00011111 00000000
|
|||
|
DW1 : KF +7
|
|||
|
DW2 : KF +7
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
PB 3 -PB3 FAULT EVALUATION C:ZONE10ST.S5D LEN=625
|
|||
|
Page 10
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
F 1.0 = M 1.0 FLT.EVAL. SLOW
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 21 special faults DW 9
|
|||
|
:L IW 18
|
|||
|
:T FW 200
|
|||
|
:
|
|||
|
:A -E 18.3=z10+b1.HO502-lid
|
|||
|
:A -E 18.6=z10+b1.HO503-lid
|
|||
|
:A -E 19.1=z10+b1.HO504-lid
|
|||
|
:O -E 18.0=z10+b1.HO501-lid
|
|||
|
:= F 200.0
|
|||
|
:
|
|||
|
:A -E 18.0=z10+b1.HO501-lid
|
|||
|
:A -E 18.6=z10+b1.HO503-lid
|
|||
|
:A -E 19.1=z10+b1.HO504-lid
|
|||
|
:O -E 18.3=z10+b1.HO502-lid
|
|||
|
:= F 200.3
|
|||
|
:
|
|||
|
:A -E 18.0=z10+b1.HO501-lid
|
|||
|
:A -E 18.3=z10+b1.HO502-lid
|
|||
|
:A -E 19.1=z10+b1.HO504-lid
|
|||
|
:O -E 18.6=z10+b1.HO503-lid
|
|||
|
:= F 200.6
|
|||
|
:
|
|||
|
:A -E 18.0=z10+b1.HO501-lid
|
|||
|
:A -E 18.3=z10+b1.HO502-lid
|
|||
|
:A -E 18.6=z10+b1.HO503-lid
|
|||
|
:O -E 19.1=z10+b1.HO504-lid
|
|||
|
:= F 201.1
|
|||
|
:
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS BN
|
|||
|
IMP : -M 0.7 FLT.EVAL. FAST
|
|||
|
AW1 : FW 200
|
|||
|
AW2 : FW 202
|
|||
|
EW1 : FW 204
|
|||
|
EW2 : FW 206
|
|||
|
FILT : KM 01101101 10000011 *(3) E18.2,E18.5,E19.0
|
|||
|
DW1 : KF +9
|
|||
|
DW2 : KF +9
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
I 18.3 = E 18.3=z10+b1.HO502-lid lid closed HO 502
|
|||
|
I 18.6 = E 18.6=z10+b1.HO503-lid lid closed HO 503
|
|||
|
I 19.1 = E 19.1=z10+b1.HO504-lid lid closed HO 504
|
|||
|
I 18.0 = E 18.0=z10+b1.HO501-lid lid closed HO 501
|
|||
|
PB 3 -PB3 FAULT EVALUATION C:ZONE10ST.S5D LEN=625
|
|||
|
Page 11
|
|||
|
F 0.7 = M 0.7 FLT.EVAL. FAST
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 22 special faults DW 10
|
|||
|
:L IW 20
|
|||
|
:T FW 200
|
|||
|
:
|
|||
|
:CX -DX200 PL1-5 MX520,HO580
|
|||
|
:ON D 161.5 HO580 ENPTY-PHASE RUNNING
|
|||
|
:O -E 20.2=z10+b3.HO580-bin
|
|||
|
:AN -M 50.4 HO580 FAULT BIN
|
|||
|
:= F 200.2
|
|||
|
: *(5)
|
|||
|
:O -E 21.5=z10+b3.BD560-flm *(5)
|
|||
|
:ON -A 20.1=z10+b3.BD560-aps *(5)
|
|||
|
:= F 201.5 *(5)
|
|||
|
: *(5)
|
|||
|
:O -E 21.7=z10+b3.BD560-flm *(5)
|
|||
|
:ON -A 20.2=z10+b3.BD560-aps *(5)
|
|||
|
:= F 201.7 *(5)
|
|||
|
:*** *(5) One network split in two!
|
|||
|
|
|||
|
I 20.2 = E 20.2=z10+b3.HO580-bin bin available HO 580
|
|||
|
F 50.4 = M 50.4 HO580 FAULT BIN
|
|||
|
I 21.5 = E 21.5=z10+b3.BD560-flm flowmeter 1 healthy BD 560 *(5)
|
|||
|
Q 20.1 = A 20.1=z10+b3.BD560-aps air purged seals 1 on BD 560 *(5)
|
|||
|
I 21.7 = E 21.7=z10+b3.BD560-flm flowmeter 2 healthy BD 560 *(5)
|
|||
|
Q 20.2 = A 20.2=z10+b3.BD560-aps air purged seals 2 on BD 560 *(5)
|
|||
|
|
|||
|
DX 200 = DX200 PL1-5 MX520,HO580 PL1-3: UNIT MX520 PL4,5: UNIT HO580
|
|||
|
|
|||
|
Segment 23 special faults DW10 *(5)
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q *(5) One network split in two!
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS BN
|
|||
|
IMP : -M 0.7 FLT.EVAL. FAST
|
|||
|
AW1 : FW 200
|
|||
|
AW2 : FW 202
|
|||
|
EW1 : FW 204
|
|||
|
EW2 : FW 206
|
|||
|
FILT : KM 11001100 10100000 *(5) S21.5, S21.7
|
|||
|
DW1 : KF +10
|
|||
|
DW2 : KF +10
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
F 0.7 = M 0.7 FLT.EVAL. FAST
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 24 special faults DW 10
|
|||
|
:O -A 18.7=z10+b3.HO580-exh
|
|||
|
PB 3 -PB3 FAULT EVALUATION C:ZONE10ST.S5D LEN=625
|
|||
|
Page 12
|
|||
|
:O -E 21.6=z10+b3.HO580-exh
|
|||
|
:= F 201.6
|
|||
|
:
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS MO
|
|||
|
IMP : -M 1.0 FLT.EVAL. SLOW
|
|||
|
AW1 : FW 200
|
|||
|
AW2 : FW 202
|
|||
|
EW1 : IW 20
|
|||
|
EW2 : FW 204
|
|||
|
FILT : KM 00000000 01000000
|
|||
|
DW1 : KF +10
|
|||
|
DW2 : KF +10
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
Q 18.7 = A 18.7=z10+b3.HO580-exh exhaust Pfc on HO 580
|
|||
|
I 21.6 = E 21.6=z10+b3.HO580-exh exhaust Pfc on HO 580
|
|||
|
F 1.0 = M 1.0 FLT.EVAL. SLOW
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
Segment 25 special faults DW 11
|
|||
|
:L IW 22
|
|||
|
:T FW 200
|
|||
|
:
|
|||
|
:CX -DX201 PL6-10HO561,BD560
|
|||
|
:L DW 226
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:= F 210.0 cone mill/ hammer mill requested
|
|||
|
:
|
|||
|
:L DW 226
|
|||
|
:L KF +4
|
|||
|
:!=F
|
|||
|
:AN -E 22.6=z10+b3.HO561-ham
|
|||
|
:O(
|
|||
|
:L DW 226 01
|
|||
|
:L KF +4 01
|
|||
|
:><F 01
|
|||
|
:A F 210.0 01 cone mill/ hammer mill requested
|
|||
|
:A -E 22.6=z10+b3.HO561-ham 01
|
|||
|
:) 01
|
|||
|
:A -M 60.1 CHARGE ACT.BD560 *(6)
|
|||
|
:= F 200.6
|
|||
|
:
|
|||
|
:L DW 226
|
|||
|
:L KF +4
|
|||
|
:><F
|
|||
|
:A F 210.0 cone mill/ hammer mill requested
|
|||
|
:AN -E 22.7=z10+b3.HO561-com
|
|||
|
:O(
|
|||
|
:L DW 226 01
|
|||
|
:L KF +4 01
|
|||
|
:!=F 01
|
|||
|
PB 3 -PB3 FAULT EVALUATION C:ZONE10ST.S5D LEN=625
|
|||
|
Page 13
|
|||
|
:A -E 22.7=z10+b3.HO561-com 01
|
|||
|
:) 01
|
|||
|
:A -M 60.1 CHARGE ACT.BD560 *(6)
|
|||
|
:= F 200.7
|
|||
|
:
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS BI
|
|||
|
IMP : -M 0.7 FLT.EVAL. FAST
|
|||
|
AW1 : FW 200
|
|||
|
AW2 : FW 202
|
|||
|
EW1 : FW 204
|
|||
|
EW2 : FW 206
|
|||
|
FILT : KM 11000000 00000000
|
|||
|
DW1 : KF +11
|
|||
|
DW2 : KF +11
|
|||
|
FRG : -M 1.1 CONTROL VOLTAGE
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
I 22.6 = E 22.6=z10+b3.HO561-ham hammer mill request HO 561
|
|||
|
F 60.1 = M 60.1 CHARGE ACT.BD560
|
|||
|
I 22.7 = E 22.7=z10+b3.HO561-com cone mill request HO 561
|
|||
|
F 0.7 = M 0.7 FLT.EVAL. FAST
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
DX 201 = DX201 PL6-10HO561,BD560 PL6:RES PL7-9:UNIT HO561 PL10:UNIT BD560
|
|||
|
|
|||
|
Segment 26 special faults DW 12
|
|||
|
:JU -FB101 FAULT RW/KL/MO/Q
|
|||
|
Name :STOERUNG
|
|||
|
TYP : KS BN
|
|||
|
IMP : -M 0.7 FLT.EVAL. FAST
|
|||
|
AW1 : IW 24
|
|||
|
AW2 : FW 202
|
|||
|
EW1 : FW 204
|
|||
|
EW2 : FW 206
|
|||
|
FILT : KM 00000000 00000001
|
|||
|
DW1 : KF +12
|
|||
|
DW2 : KF +12
|
|||
|
FRG : -M 0.1 CONSTANT 1
|
|||
|
QUIT : KM 00000000 00000000
|
|||
|
ANZ : KF +1
|
|||
|
STDB : -DB100 FAULT EVALUATION
|
|||
|
SAST : F 202.0
|
|||
|
AEND : F 202.0
|
|||
|
:BE
|
|||
|
|
|||
|
F 0.7 = M 0.7 FLT.EVAL. FAST
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 101 = FB101 FAULT RW/KL/MO/Q fault evaluation word by word HKT al
|
|||
|
|
|||
|
PB 5 C:ZONE10ST.S5D LEN=21
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
:DOU FX 1
|
|||
|
Name :A
|
|||
|
:
|
|||
|
:JU -FB180 INTOUCH - SCALE
|
|||
|
Name :INTOUCH
|
|||
|
DBZE : KF +8413
|
|||
|
DBDA : KF +222
|
|||
|
DBRE : KF +0
|
|||
|
:
|
|||
|
:JU -FB180 INTOUCH - SCALE
|
|||
|
Name :INTOUCH
|
|||
|
DBZE : KF +8415
|
|||
|
DBDA : KF +224
|
|||
|
DBRE : KF +0
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 180 = FB180 INTOUCH - SCALE
|
|||
|
|
|||
|
|
|||
|
PB 10 -PB10 HO501-HO504 FEED.H C:ZONE10ST.S5D LEN=33
|
|||
|
Page 1
|
|||
|
Segment 1 Addition FiFo hopper HO501-HO504
|
|||
|
:L KF +240
|
|||
|
:T -MW180 PARAMETER 1 FiFo - DB
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T -MW182 PARAMETER 2 FiFo - Output
|
|||
|
:
|
|||
|
:JU -FB160 FIFO
|
|||
|
Name :FIFO
|
|||
|
DB : -MW180 PARAMETER 1 FiFo - DB
|
|||
|
:
|
|||
|
:JU -FB175 LOAD DW INDIR.
|
|||
|
Name :LADE DW
|
|||
|
DB : -MW180 PARAMETER 1 FiFo - DB
|
|||
|
DW : -MW182 PARAMETER 2 FiFo - Output
|
|||
|
DBDX : KS DB
|
|||
|
:
|
|||
|
:T -MW176 ACT.NO. ADD.-FIFO
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
FW 176 = MW176 ACT.NO. ADD.-FIFO
|
|||
|
|
|||
|
FB 160 = FB160 FIFO sa
|
|||
|
FB 175 = FB175 LOAD DW INDIR. sp
|
|||
|
|
|||
|
Segment 2
|
|||
|
:JU -SB11 IO HO501 FEED.H A1
|
|||
|
:
|
|||
|
:JU -SB12 IO HO502 FEED.H A1
|
|||
|
:
|
|||
|
:JU -SB13 IO HO503 FEED.H A1
|
|||
|
:
|
|||
|
:JU -SB14 IO HO504 FEED.H A1
|
|||
|
:BE
|
|||
|
|
|||
|
SB 11 = SB11 IO HO501 FEED.H A1 In-/Output HO501 area 1: feeding hopper
|
|||
|
SB 12 = SB12 IO HO502 FEED.H A1 In-/Output HO502 area 1: feeding hopper
|
|||
|
SB 13 = SB13 IO HO503 FEED.H A1 In-/Output HO503 area 1: feeding hopper
|
|||
|
SB 14 = SB14 IO HO504 FEED.H A1 In-/Output HO504 area 1: feeding hopper
|
|||
|
|
|||
|
PB 11 -PB11 IO HO500 SCALE 1 C:ZONE10ST.S5D LEN=235
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
:C -DB11 HO500 SCALE1:HO50X
|
|||
|
:***
|
|||
|
|
|||
|
DB 11 = DB11 HO500 SCALE1:HO50X HO500 area 1 scale 1: ingredient weighin
|
|||
|
|
|||
|
Segment 2 load inputs
|
|||
|
:A -E 6.0=z10+b1.HO500-vac
|
|||
|
:AN -S 6.0=z10+b1.HO500-vac
|
|||
|
:A -E 6.1=z10+b1.piv500-va
|
|||
|
:AN -S 6.1=z10+b1.piv500-va
|
|||
|
:= -ME26.0 VACUUMPUMP ON
|
|||
|
:
|
|||
|
:A -E 6.4=z10+b1.HO500-vi:
|
|||
|
:AN -S 6.4=z10+b1.HO500-vi:
|
|||
|
:= -ME26.1 VIBRATOR ON
|
|||
|
:
|
|||
|
:A -E 11.4=z10+b1.HO500-unv
|
|||
|
:AN -S 11.4=z10+b1.HO500-unv
|
|||
|
:AN -S 15.4=z10+b1.HO500-unv
|
|||
|
:= -ME26.2 UNLOAD VALVE CON
|
|||
|
:
|
|||
|
:A -E 11.5=z10+b1.HO500-fav
|
|||
|
:AN -S 11.5=z10+b1.HO500-fav
|
|||
|
:AN -S 15.5=z10+b1.HO500-fav
|
|||
|
:= -ME26.4 FRESH AIR VAL CL
|
|||
|
:***
|
|||
|
|
|||
|
I 6.0 = E 6.0=z10+b1.HO500-vac vacuumpump on HO 500
|
|||
|
S 6.0 = S 6.0=z10+b1.HO500-vac vacuumpump on HO 500
|
|||
|
I 6.1 = E 6.1=z10+b1.piv500-va vacuumpump on pinch valve 500
|
|||
|
S 6.1 = S 6.1=z10+b1.piv500-va vacuumpump on pinch valve 500
|
|||
|
F 26.0 = ME26.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
I 6.4 = E 6.4=z10+b1.HO500-vi: vibrator on HO 500
|
|||
|
S 6.4 = S 6.4=z10+b1.HO500-vi: vibrator on HO 500
|
|||
|
F 26.1 = ME26.1 VIBRATOR ON
|
|||
|
I 11.4 = E 11.4=z10+b1.HO500-unv unload valve convey HO 500
|
|||
|
S 11.4 = S 11.4=z10+b1.HO500-unv unload valve convey HO 500
|
|||
|
S 15.4 = S 15.4=z10+b1.HO500-unv unload valve run through HO 500
|
|||
|
F 26.2 = ME26.2 UNLOAD VALVE CON
|
|||
|
I 11.5 = E 11.5=z10+b1.HO500-fav fresh air valve closed HO 500
|
|||
|
S 11.5 = S 11.5=z10+b1.HO500-fav fresh air valve closed HO 500
|
|||
|
S 15.5 = S 15.5=z10+b1.HO500-fav fresh air valve open HO 500
|
|||
|
F 26.4 = ME26.4 FRESH AIR VAL CL
|
|||
|
|
|||
|
Segment 3 load inputs
|
|||
|
:A -E 11.6=z10+b1.HO500-ofl
|
|||
|
:AN -S 11.6=z10+b1.HO500-ofl
|
|||
|
:AN -S 15.6=z10+b1.HO500-ofl
|
|||
|
:= -ME26.5 OUTLETFLAP OPEN
|
|||
|
:
|
|||
|
:A -E 15.4=z10+b1.HO500-unv
|
|||
|
:AN -S 11.4=z10+b1.HO500-unv
|
|||
|
:AN -S 15.4=z10+b1.HO500-unv
|
|||
|
:= -ME27.2 UNLOAD V. RUN TH
|
|||
|
:
|
|||
|
:A -E 15.5=z10+b1.HO500-fav
|
|||
|
:AN -S 11.5=z10+b1.HO500-fav
|
|||
|
:AN -S 15.5=z10+b1.HO500-fav
|
|||
|
:= -ME27.4 FRESH AIR VAL OP
|
|||
|
:
|
|||
|
:A -E 15.6=z10+b1.HO500-ofl
|
|||
|
:AN -S 11.6=z10+b1.HO500-ofl
|
|||
|
:AN -S 15.6=z10+b1.HO500-ofl
|
|||
|
PB 11 -PB11 IO HO500 SCALE 1 C:ZONE10ST.S5D LEN=235
|
|||
|
Page 2
|
|||
|
:= -ME27.5 OUTLETFL. CLOSED
|
|||
|
:***
|
|||
|
|
|||
|
I 11.6 = E 11.6=z10+b1.HO500-ofl outletflap 1O2I open HO 500
|
|||
|
S 11.6 = S 11.6=z10+b1.HO500-ofl outletflap 1O2I open HO 500
|
|||
|
S 15.6 = S 15.6=z10+b1.HO500-ofl outletflap 1O2I closed HO 500
|
|||
|
F 26.5 = ME26.5 OUTLETFLAP OPEN
|
|||
|
I 15.4 = E 15.4=z10+b1.HO500-unv unload valve run through HO 500
|
|||
|
S 11.4 = S 11.4=z10+b1.HO500-unv unload valve convey HO 500
|
|||
|
S 15.4 = S 15.4=z10+b1.HO500-unv unload valve run through HO 500
|
|||
|
F 27.2 = ME27.2 UNLOAD V. RUN TH
|
|||
|
I 15.5 = E 15.5=z10+b1.HO500-fav fresh air valve open HO 500
|
|||
|
S 11.5 = S 11.5=z10+b1.HO500-fav fresh air valve closed HO 500
|
|||
|
S 15.5 = S 15.5=z10+b1.HO500-fav fresh air valve open HO 500
|
|||
|
F 27.4 = ME27.4 FRESH AIR VAL OP
|
|||
|
I 15.6 = E 15.6=z10+b1.HO500-ofl outletflap 1O2I closed HO 500
|
|||
|
F 27.5 = ME27.5 OUTLETFL. CLOSED
|
|||
|
|
|||
|
Segment 4 load inputs
|
|||
|
:A -E 19.7=z10+b1.HO500-sfi
|
|||
|
:AN -S 19.7=z10+b1.HO500-sfi
|
|||
|
:= -ME27.7 SECUNDARY FIL.OK
|
|||
|
:
|
|||
|
:A -E 14.0=z10+b1.HO500-piv
|
|||
|
:= -ME30.0 COMPV_1 CL/pos.1
|
|||
|
:
|
|||
|
:A -E 14.1=z10+b1.HO500-piv
|
|||
|
:= -ME30.1 COMPV_2 CLOSED
|
|||
|
:
|
|||
|
:A -E 14.2=z10+b1.HO500-piv
|
|||
|
:= -ME30.2 COMPV_3 CLOSED
|
|||
|
:
|
|||
|
:A -E 14.3=z10+b1.HO500-piv
|
|||
|
:= -ME30.3 COMPV_4 CLOSED
|
|||
|
:
|
|||
|
:A -E 14.4=z10+b1.HO500-piv
|
|||
|
:= -ME30.4 COMPV_5 CLOSED
|
|||
|
:***
|
|||
|
|
|||
|
I 19.7 = E 19.7=z10+b1.HO500-sfi secondary filter healthy HO 500
|
|||
|
S 19.7 = S 19.7=z10+b1.HO500-sfi secondary filter healthy HO 500
|
|||
|
F 27.7 = ME27.7 SECUNDARY FIL.OK
|
|||
|
I 14.0 = E 14.0=z10+b1.HO500-piv pinch valve O<>I 1 closed HO 500
|
|||
|
F 30.0 = ME30.0 COMPV_1 CL/pos.1
|
|||
|
I 14.1 = E 14.1=z10+b1.HO500-piv pinch valve O<>I 2 closed HO 500
|
|||
|
F 30.1 = ME30.1 COMPV_2 CLOSED
|
|||
|
I 14.2 = E 14.2=z10+b1.HO500-piv pinch valve O<>I 3 closed HO 500
|
|||
|
F 30.2 = ME30.2 COMPV_3 CLOSED
|
|||
|
I 14.3 = E 14.3=z10+b1.HO500-piv pinch valve O<>I 4 closed HO 500
|
|||
|
F 30.3 = ME30.3 COMPV_4 CLOSED
|
|||
|
I 14.4 = E 14.4=z10+b1.HO500-piv pinch valve O<>I 5 closed HO 500
|
|||
|
F 30.4 = ME30.4 COMPV_5 CLOSED
|
|||
|
|
|||
|
Segment 5 load inputs
|
|||
|
:O -S 14.0=z10+b1.HO500-piv
|
|||
|
:O -S 14.1=z10+b1.HO500-piv
|
|||
|
:O -S 14.2=z10+b1.HO500-piv
|
|||
|
:O -S 14.3=z10+b1.HO500-piv
|
|||
|
:O -S 14.4=z10+b1.HO500-piv
|
|||
|
:= -ME30.7 FAULT COMP. VAL.
|
|||
|
:
|
|||
|
:A -M 0.1 CONSTANT 1
|
|||
|
:= -ME31.3 REL CTRL-FINE
|
|||
|
:
|
|||
|
PB 11 -PB11 IO HO500 SCALE 1 C:ZONE10ST.S5D LEN=235
|
|||
|
Page 3
|
|||
|
:L DW 121 calibrate conveying pressure
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:O -E 6.0=z10+b1.HO500-vac
|
|||
|
:= -ME31.4 VACUUM ACTIV
|
|||
|
:
|
|||
|
:CX -DX200 PL1-5 MX520,HO580 *(6)
|
|||
|
:A D 111.5 *(6) RUNNING BY PLI HO500_DISNOP
|
|||
|
:= -ME31.6 PLI_DISCHARG.RUN *(6)
|
|||
|
:
|
|||
|
:A -E 24.0=z10+DKC.MX520-ch
|
|||
|
:= -ME31.7 SCALE_DISCH REL.
|
|||
|
:***
|
|||
|
|
|||
|
S 14.0 = S 14.0=z10+b1.HO500-piv pinch valve O<>I 1 closed HO 500
|
|||
|
S 14.1 = S 14.1=z10+b1.HO500-piv pinch valve O<>I 2 closed HO 500
|
|||
|
S 14.2 = S 14.2=z10+b1.HO500-piv pinch valve O<>I 3 closed HO 500
|
|||
|
S 14.3 = S 14.3=z10+b1.HO500-piv pinch valve O<>I 4 closed HO 500
|
|||
|
S 14.4 = S 14.4=z10+b1.HO500-piv pinch valve O<>I 5 closed HO 500
|
|||
|
F 30.7 = ME30.7 FAULT COMP. VAL.
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 31.3 = ME31.3 REL CTRL-FINE
|
|||
|
I 6.0 = E 6.0=z10+b1.HO500-vac vacuumpump on HO 500
|
|||
|
F 31.4 = ME31.4 VACUUM ACTIV
|
|||
|
F 31.6 = ME31.6 PLI_DISCHARG.RUN *(6)
|
|||
|
I 24.0 = E 24.0=z10+DKC.MX520-ch charge 1 ready MX 520
|
|||
|
F 31.7 = ME31.7 SCALE_DISCH REL.
|
|||
|
|
|||
|
DX 200 = DX200 PL1-5 MX520,HO580 PL1-3: UNIT MX520 PL4,5: UNIT HO580
|
|||
|
|
|||
|
Segment 6 load step index register
|
|||
|
:JU -FB177 LOAD DW DIREKT
|
|||
|
Name :LADE DW
|
|||
|
DB : KF +200
|
|||
|
DW : KF +53
|
|||
|
DBDX : KS DX
|
|||
|
:T FW 194 charge SI
|
|||
|
:
|
|||
|
:JU -FB177 LOAD DW DIREKT
|
|||
|
Name :LADE DW
|
|||
|
DB : KF +200
|
|||
|
DW : KF +103
|
|||
|
DBDX : KS DX
|
|||
|
:T FW 196 discharge_nop SI
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 177 = FB177 LOAD DW DIREKT sp
|
|||
|
|
|||
|
Segment 7
|
|||
|
:JU -FB11 HO500 SCALE1:HO50X
|
|||
|
Name :WAAGE
|
|||
|
LINR : KF +1
|
|||
|
WANR : KF +1
|
|||
|
WZNR : KF +1
|
|||
|
T1 : KF +40
|
|||
|
T2 : KF +41
|
|||
|
T3 : KF +42
|
|||
|
T4 : KF +43
|
|||
|
T5 : KF +44
|
|||
|
T6 : KF +45
|
|||
|
T7 : KF +46
|
|||
|
T8 : KF +47
|
|||
|
T9 : KF +48
|
|||
|
PB 11 -PB11 IO HO500 SCALE 1 C:ZONE10ST.S5D LEN=235
|
|||
|
Page 4
|
|||
|
T10 : KF +49
|
|||
|
AF/J : KS N
|
|||
|
PWDT : KF +128
|
|||
|
PWFU : KF +128
|
|||
|
CPSI : FW 194
|
|||
|
ECSI : -M 42.0 HO500 EOF CHA SI
|
|||
|
DPSI : FW 196
|
|||
|
EDSI : -M 42.1 HO500 EOF DIS SI
|
|||
|
EMPY : -M 42.2 HO500 EMPTY-RANG
|
|||
|
:***
|
|||
|
|
|||
|
F 42.0 = M 42.0 HO500 EOF CHA SI
|
|||
|
F 42.1 = M 42.1 HO500 EOF DIS SI
|
|||
|
F 42.2 = M 42.2 HO500 EMPTY-RANG
|
|||
|
|
|||
|
FB 11 = FB11 HO500 SCALE1:HO50X HO500 area 1 scale 1: ingredient weighin
|
|||
|
|
|||
|
Segment 8 write motor outputs
|
|||
|
:A -MA24.0 VACUUMPUMP ON
|
|||
|
:AN -S 6.0=z10+b1.HO500-vac
|
|||
|
:AN -S 6.1=z10+b1.piv500-va
|
|||
|
:= -A 6.0=z10+b1.HO500-vac
|
|||
|
:= -A 6.1=z10+b1.piv500-va
|
|||
|
:
|
|||
|
:A -MA24.1 VIBRATOR ON
|
|||
|
:AN -S 6.4=z10+b1.HO500-vi:
|
|||
|
:= -A 6.4=z10+b1.HO500-vi:
|
|||
|
:***
|
|||
|
|
|||
|
F 24.0 = MA24.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
S 6.0 = S 6.0=z10+b1.HO500-vac vacuumpump on HO 500
|
|||
|
S 6.1 = S 6.1=z10+b1.piv500-va vacuumpump on pinch valve 500
|
|||
|
Q 6.0 = A 6.0=z10+b1.HO500-vac vacuumpump on HO 500
|
|||
|
Q 6.1 = A 6.1=z10+b1.piv500-va vacuumpump on pinch valve 500
|
|||
|
F 24.1 = MA24.1 VIBRATOR ON
|
|||
|
S 6.4 = S 6.4=z10+b1.HO500-vi: vibrator on HO 500
|
|||
|
Q 6.4 = A 6.4=z10+b1.HO500-vi: vibrator on HO 500
|
|||
|
|
|||
|
Segment 9 write outputs
|
|||
|
:A -MA24.2 UNLOAD VALVE CON
|
|||
|
:= -A 11.4=z10+b1.HO500-unv
|
|||
|
:
|
|||
|
:A -MA24.4 FRESH AIR VAL CL
|
|||
|
:= -A 11.5=z10+b1.HO500-fav
|
|||
|
:
|
|||
|
:A -MA24.5 OUTLETFLAP OPEN
|
|||
|
:= -A 11.6=z10+b1.HO500-ofl
|
|||
|
:S -M 165.6 MX520 DI_NO ROK
|
|||
|
:
|
|||
|
:A -MA24.7 ANGLE VALVE DISC
|
|||
|
:= -A 18.0=z10+b1.HO500-anv
|
|||
|
:
|
|||
|
:A -MA25.0 COMPRES.AIR ON
|
|||
|
:= -A 17.7=z10+b1.HO500-coa
|
|||
|
:
|
|||
|
:A -MA25.2 FILTER 1 ON
|
|||
|
:= -A 17.0=z10+b1.HO500-paf
|
|||
|
:***
|
|||
|
|
|||
|
F 24.2 = MA24.2 UNLOAD VALVE CON
|
|||
|
Q 11.4 = A 11.4=z10+b1.HO500-unv unload valve convey HO 500
|
|||
|
F 24.4 = MA24.4 FRESH AIR VAL CL
|
|||
|
Q 11.5 = A 11.5=z10+b1.HO500-fav fresh air valve closed HO 500
|
|||
|
F 24.5 = MA24.5 OUTLETFLAP OPEN
|
|||
|
PB 11 -PB11 IO HO500 SCALE 1 C:ZONE10ST.S5D LEN=235
|
|||
|
Page 5
|
|||
|
Q 11.6 = A 11.6=z10+b1.HO500-ofl outletflap 1O2I open HO 500
|
|||
|
F 165.6 = M 165.6 MX520 DI_NO ROK enable reports
|
|||
|
F 24.7 = MA24.7 ANGLE VALVE DISC
|
|||
|
Q 18.0 = A 18.0=z10+b1.HO500-anv angle valve 1O discharge HO 500
|
|||
|
F 25.0 = MA25.0 COMPRES.AIR ON
|
|||
|
Q 17.7 = A 17.7=z10+b1.HO500-coa compressed air impulse HO 500
|
|||
|
F 25.2 = MA25.2 FILTER 1 ON
|
|||
|
Q 17.0 = A 17.0=z10+b1.HO500-paf purged air filter 1 on HO 500
|
|||
|
|
|||
|
Segment 10 write outputs
|
|||
|
:A -MA25.3 FILTER 2 ON
|
|||
|
:= -A 17.1=z10+b1.HO500-paf
|
|||
|
:
|
|||
|
:A -MA25.5 RAPPER 1 ON
|
|||
|
:= -A 17.5=z10+b1.HO500-rap
|
|||
|
:
|
|||
|
:A -MA25.6 RAPPER 2 ON
|
|||
|
:= -A 17.6=z10+b1.HO500-rap
|
|||
|
:
|
|||
|
:A -MA28.0 COMPONENT VAL 1
|
|||
|
:= -A 14.0=z10+b1.HO500-piv
|
|||
|
:
|
|||
|
:A -MA28.1 COMPONENT VAL 2
|
|||
|
:= -A 14.1=z10+b1.HO500-piv
|
|||
|
:***
|
|||
|
|
|||
|
F 25.3 = MA25.3 FILTER 2 ON
|
|||
|
Q 17.1 = A 17.1=z10+b1.HO500-paf purged air filter 2 on HO 500
|
|||
|
F 25.5 = MA25.5 RAPPER 1 ON
|
|||
|
Q 17.5 = A 17.5=z10+b1.HO500-rap rapper 1 on HO 500
|
|||
|
F 25.6 = MA25.6 RAPPER 2 ON
|
|||
|
Q 17.6 = A 17.6=z10+b1.HO500-rap rapper 2 on HO 500
|
|||
|
F 28.0 = MA28.0 COMPONENT VAL 1
|
|||
|
Q 14.0 = A 14.0=z10+b1.HO500-piv pinch valve O<>I 1 open HO 500
|
|||
|
F 28.1 = MA28.1 COMPONENT VAL 2
|
|||
|
Q 14.1 = A 14.1=z10+b1.HO500-piv pinch valve O<>I 2 open HO 500
|
|||
|
|
|||
|
Segment 11 write outputs
|
|||
|
:A -MA28.2 COMPONENT VAL 3
|
|||
|
:= -A 14.2=z10+b1.HO500-piv
|
|||
|
:
|
|||
|
:A -MA28.3 COMPONENT VAL 4
|
|||
|
:= -A 14.3=z10+b1.HO500-piv
|
|||
|
:
|
|||
|
:A -MA28.4 COMPONENT VAL 5
|
|||
|
:= -A 14.4=z10+b1.HO500-piv
|
|||
|
:
|
|||
|
:A -MA29.6 FREQ.CONV. SILO
|
|||
|
:= -A 6.2=z10+b1.HO500-fco
|
|||
|
:
|
|||
|
:A -MA29.7 SCALE_DISCH ON
|
|||
|
:= -A 24.0=z10+AZO.HO500-di
|
|||
|
:***
|
|||
|
|
|||
|
F 28.2 = MA28.2 COMPONENT VAL 3
|
|||
|
Q 14.2 = A 14.2=z10+b1.HO500-piv pinch valve O<>I 3 open HO 500
|
|||
|
F 28.3 = MA28.3 COMPONENT VAL 4
|
|||
|
Q 14.3 = A 14.3=z10+b1.HO500-piv pinch valve O<>I 4 open HO 500
|
|||
|
F 28.4 = MA28.4 COMPONENT VAL 5
|
|||
|
Q 14.4 = A 14.4=z10+b1.HO500-piv pinch valve O<>I 5 open HO 500
|
|||
|
F 29.6 = MA29.6 FREQ.CONV. SILO
|
|||
|
Q 6.2 = A 6.2=z10+b1.HO500-fco frequ.converter release HO 500
|
|||
|
F 29.7 = MA29.7 SCALE_DISCH ON
|
|||
|
Q 24.0 = A 24.0=z10+AZO.HO500-di discharge 1 on HO 500
|
|||
|
PB 11 -PB11 IO HO500 SCALE 1 C:ZONE10ST.S5D LEN=235
|
|||
|
Page 6
|
|||
|
Segment 12 faults scale
|
|||
|
:A -M 18.6 PRESSURE_FAULT
|
|||
|
:= -M 40.0 HO500 PRES.FAULT
|
|||
|
:
|
|||
|
:C -DB101 SCALE 01 (WORK)
|
|||
|
:O D 191.8
|
|||
|
:O D 192.8
|
|||
|
:O D 192.9
|
|||
|
:O D 192.10
|
|||
|
:O D 192.11
|
|||
|
:O D 192.12
|
|||
|
:O D 192.13
|
|||
|
:O D 192.14
|
|||
|
:= -M 41.0 HO500 WEIG.FAULT
|
|||
|
:BE
|
|||
|
|
|||
|
F 18.6 = M 18.6 PRESSURE_FAULT
|
|||
|
F 40.0 = M 40.0 HO500 PRES.FAULT
|
|||
|
F 41.0 = M 41.0 HO500 WEIG.FAULT
|
|||
|
|
|||
|
DB 101 = DB101 SCALE 01 (WORK) working DB plc scale RAM
|
|||
|
|
|||
|
PB 30 -PB30 BLENDER BD560 C:ZONE10ST.S5D LEN=59
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
: *(6) ax dx41
|
|||
|
:L KF +41 *(6) l dw0
|
|||
|
:T FW 190 scale working DB
|
|||
|
:
|
|||
|
:CX -DX201 PL6-10HO561,BD560
|
|||
|
:L DW 203
|
|||
|
:T FW 192 charge phase step index
|
|||
|
:
|
|||
|
:CX -DX202 PL11-15 BD560,RES
|
|||
|
:L DW 53
|
|||
|
:T FW 194 blend phase step index
|
|||
|
:
|
|||
|
:L DW 3
|
|||
|
:T FW 198 man_add phase step index
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
DX 201 = DX201 PL6-10HO561,BD560 PL6:RES PL7-9:UNIT HO561 PL10:UNIT BD560
|
|||
|
DX 202 = DX202 PL11-15 BD560,RES PL11-14: UNIT BD560 PL15: RESERVE
|
|||
|
|
|||
|
Segment 2 discharge_nop/discharge phase SI
|
|||
|
:L KF +0
|
|||
|
:
|
|||
|
:A -M 62.1 STRT DINOP BD560
|
|||
|
:JC -FB177 LOAD DW DIREKT
|
|||
|
Name :LADE DW
|
|||
|
DB : KF +202
|
|||
|
DW : KF +103
|
|||
|
DBDX : KS DX
|
|||
|
:
|
|||
|
:A -M 60.4 STRT DISCH.BD560
|
|||
|
:JC -FB177 LOAD DW DIREKT
|
|||
|
Name :LADE DW
|
|||
|
DB : KF +202
|
|||
|
DW : KF +153
|
|||
|
DBDX : KS DX
|
|||
|
:
|
|||
|
:T FW 196
|
|||
|
:***
|
|||
|
|
|||
|
F 62.1 = M 62.1 STRT DINOP BD560
|
|||
|
F 60.4 = M 60.4 STRT DISCH.BD560
|
|||
|
|
|||
|
FB 177 = FB177 LOAD DW DIREKT sp
|
|||
|
|
|||
|
Segment 3
|
|||
|
:CX -DX200 PL1-5 MX520,HO580 *(6)
|
|||
|
:L DW 203 *(6)
|
|||
|
:T FW 172 *(6) charge phase 2 step index
|
|||
|
:
|
|||
|
:JU -FB30 BLENDER BD560
|
|||
|
Name :BL560
|
|||
|
CPSI : FW 192
|
|||
|
BPSI : FW 194
|
|||
|
DPSI : FW 196
|
|||
|
MPSI : FW 198
|
|||
|
WADB : FW 190
|
|||
|
C2SI : FW 172 *(6)
|
|||
|
:
|
|||
|
:A -M 0.1 CONSTANT 1
|
|||
|
:R -M 61.0 RESET ALL BLTIME
|
|||
|
:BE
|
|||
|
|
|||
|
PB 30 -PB30 BLENDER BD560 C:ZONE10ST.S5D LEN=59
|
|||
|
Page 2
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 61.0 = M 61.0 RESET ALL BLTIME
|
|||
|
|
|||
|
FB 30 = FB30 BLENDER BD560
|
|||
|
|
|||
|
DX 200 = DX200 PL1-5 MX520,HO580 PL1-3: UNIT MX520 PL4,5: UNIT HO580
|
|||
|
|
|||
|
PB 31 -PB31 IO HO561 SCALE 3 C:ZONE10ST.S5D LEN=223
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
:C -DB103 SCALE 03 (WORK) *(6)
|
|||
|
:A D 191.0 *(6) Waage 3: KEbene aktiv
|
|||
|
:A -M 59.6 ABORT HO561_DISC *(6)
|
|||
|
:C -DB208 CONTROL DB PLC SC *(6)
|
|||
|
:S D 5.6 *(6) Waage 2: Komponente abbrech
|
|||
|
: *(6)
|
|||
|
:C -DB31 HO561 SCALE3:DR540
|
|||
|
:***
|
|||
|
|
|||
|
F 59.6 = M 59.6 ABORT HO561_DISC *(6)
|
|||
|
|
|||
|
DB 103 = DB103 SCALE 03 (WORK) working DB plc scale RAM
|
|||
|
DB 208 = DB208 CONTROL DB PLC SC control bits PC<->PLC plc scale RAM
|
|||
|
DB 31 = DB31 HO561 SCALE3:DR540 HO561 area 3 scale 3: from dryer
|
|||
|
|
|||
|
Segment 2 Load inputs
|
|||
|
:A -E 9.0=z10+b3.HO561-vac
|
|||
|
:AN -S 9.0=z10+b3.HO561-vac
|
|||
|
:A -E 9.1=z10+b3.HO561-vac
|
|||
|
:AN -S 9.1=z10+b3.HO561-vac
|
|||
|
:= -ME26.0 VACUUMPUMP ON
|
|||
|
:
|
|||
|
:A -E 9.2=z10+b3.HO561-vi:
|
|||
|
:AN -S 9.2=z10+b3.HO561-vi:
|
|||
|
:= -ME26.1 VIBRATOR ON
|
|||
|
:
|
|||
|
:A -E 12.5=z10+b3.HO561-anv
|
|||
|
:AN -S 12.5=z10+b3.HO561-anv
|
|||
|
:AN -S 16.5=z10+b3.HO561-anv
|
|||
|
:= -ME26.2 UNLOAD VALVE CON
|
|||
|
:
|
|||
|
:A -E 12.4=z10+b3.HO561-ofl
|
|||
|
:AN -S 12.4=z10+b3.HO561-ofl
|
|||
|
:AN -S 16.4=z10+b3.HO561-ofl
|
|||
|
:= -ME26.5 OUTLETFLAP OPEN
|
|||
|
:***
|
|||
|
|
|||
|
I 9.0 = E 9.0=z10+b3.HO561-vac vacuumpump 2 on HO 561
|
|||
|
S 9.0 = S 9.0=z10+b3.HO561-vac vacuumpump 2 on HO 561
|
|||
|
I 9.1 = E 9.1=z10+b3.HO561-vac vacuumpump 1 on HO 561
|
|||
|
S 9.1 = S 9.1=z10+b3.HO561-vac vacuumpump 1 on HO 561
|
|||
|
F 26.0 = ME26.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
I 9.2 = E 9.2=z10+b3.HO561-vi: vibrator on HO 561
|
|||
|
S 9.2 = S 9.2=z10+b3.HO561-vi: vibrator on HO 561
|
|||
|
F 26.1 = ME26.1 VIBRATOR ON
|
|||
|
I 12.5 = E 12.5=z10+b3.HO561-anv angle valve 1O2I Air open HO 561
|
|||
|
S 12.5 = S 12.5=z10+b3.HO561-anv angle valve 1O2I Air open HO 561
|
|||
|
S 16.5 = S 16.5=z10+b3.HO561-anv angle valve 1O2I Air closed HO 561
|
|||
|
F 26.2 = ME26.2 UNLOAD VALVE CON
|
|||
|
I 12.4 = E 12.4=z10+b3.HO561-ofl outletflap 1O2I open HO 561
|
|||
|
S 12.4 = S 12.4=z10+b3.HO561-ofl outletflap 1O2I open HO 561
|
|||
|
S 16.4 = S 16.4=z10+b3.HO561-ofl outletflap 1O2I closed HO 561
|
|||
|
F 26.5 = ME26.5 OUTLETFLAP OPEN
|
|||
|
|
|||
|
Segment 3 Load inputs
|
|||
|
:A -E 16.5=z10+b3.HO561-anv
|
|||
|
:AN -S 12.5=z10+b3.HO561-anv
|
|||
|
:AN -S 16.5=z10+b3.HO561-anv
|
|||
|
:= -ME27.2 UNLOAD V. RUN TH
|
|||
|
:
|
|||
|
:A -E 16.4=z10+b3.HO561-ofl
|
|||
|
:AN -S 12.4=z10+b3.HO561-ofl
|
|||
|
:AN -S 16.4=z10+b3.HO561-ofl
|
|||
|
PB 31 -PB31 IO HO561 SCALE 3 C:ZONE10ST.S5D LEN=223
|
|||
|
Page 2
|
|||
|
:= -ME27.5 OUTLETFL. CLOSED
|
|||
|
:
|
|||
|
:A -E 20.7=z10+b3.HO561-sfi
|
|||
|
:AN -S 20.7=z10+b3.HO561-sfi
|
|||
|
:= -ME27.7 SECUNDARY FIL.OK
|
|||
|
:
|
|||
|
:A -E 12.3=z10+b3.HO561-tdP
|
|||
|
:AN -S 12.3=z10+b3.HO561-tdP
|
|||
|
:AN -S 16.3=z10+b3.HO561-tdP
|
|||
|
:= -ME30.0 COMPV_1 CL/pos.1
|
|||
|
:***
|
|||
|
|
|||
|
I 16.5 = E 16.5=z10+b3.HO561-anv angle valve 1O2I Air closed HO 561
|
|||
|
S 12.5 = S 12.5=z10+b3.HO561-anv angle valve 1O2I Air open HO 561
|
|||
|
S 16.5 = S 16.5=z10+b3.HO561-anv angle valve 1O2I Air closed HO 561
|
|||
|
F 27.2 = ME27.2 UNLOAD V. RUN TH
|
|||
|
I 16.4 = E 16.4=z10+b3.HO561-ofl outletflap 1O2I closed HO 561
|
|||
|
S 12.4 = S 12.4=z10+b3.HO561-ofl outletflap 1O2I open HO 561
|
|||
|
S 16.4 = S 16.4=z10+b3.HO561-ofl outletflap 1O2I closed HO 561
|
|||
|
F 27.5 = ME27.5 OUTLETFL. CLOSED
|
|||
|
I 20.7 = E 20.7=z10+b3.HO561-sfi secondary filter healthy HO 561
|
|||
|
S 20.7 = S 20.7=z10+b3.HO561-sfi secondary filter healthy HO 561
|
|||
|
F 27.7 = ME27.7 SECUNDARY FIL.OK
|
|||
|
I 12.3 = E 12.3=z10+b3.HO561-tdP tube diverter 1O2I P position 1 HO 561
|
|||
|
S 12.3 = S 12.3=z10+b3.HO561-tdP tube diverter 1O2I P position 1 HO 561
|
|||
|
S 16.3 = S 16.3=z10+b3.HO561-tdP tube diverter 1O2I P position 2 HO 561
|
|||
|
F 30.0 = ME30.0 COMPV_1 CL/pos.1
|
|||
|
|
|||
|
Segment 4 Load inputs
|
|||
|
:A -E 16.3=z10+b3.HO561-tdP
|
|||
|
:AN -S 12.3=z10+b3.HO561-tdP
|
|||
|
:AN -S 16.3=z10+b3.HO561-tdP
|
|||
|
:= -ME31.0 COMPV_1 pos. 2
|
|||
|
:
|
|||
|
:A -M 0.1 CONSTANT 1
|
|||
|
:= -ME31.3 REL CTRL-FINE
|
|||
|
:
|
|||
|
:L DW 121 calibrate conveying pressure
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:O -E 9.1=z10+b3.HO561-vac
|
|||
|
:O -E 9.0=z10+b3.HO561-vac
|
|||
|
:= -ME31.4 VACUUM ACTIV
|
|||
|
:***
|
|||
|
|
|||
|
I 16.3 = E 16.3=z10+b3.HO561-tdP tube diverter 1O2I P position 2 HO 561
|
|||
|
S 12.3 = S 12.3=z10+b3.HO561-tdP tube diverter 1O2I P position 1 HO 561
|
|||
|
S 16.3 = S 16.3=z10+b3.HO561-tdP tube diverter 1O2I P position 2 HO 561
|
|||
|
F 31.0 = ME31.0 COMPV_1 pos. 2
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 31.3 = ME31.3 REL CTRL-FINE
|
|||
|
I 9.1 = E 9.1=z10+b3.HO561-vac vacuumpump 1 on HO 561
|
|||
|
I 9.0 = E 9.0=z10+b3.HO561-vac vacuumpump 2 on HO 561
|
|||
|
F 31.4 = ME31.4 VACUUM ACTIV
|
|||
|
|
|||
|
Segment 5 Load inputs
|
|||
|
:CX -DX201 PL6-10HO561,BD560 *(6)
|
|||
|
:A D 161.5 *(6) RUNNING BY PLI HO561_DISCHA
|
|||
|
:= -ME31.6 PLI_DISCHARG.RUN *(6)
|
|||
|
:
|
|||
|
:A -A 9.3=z10+b3.MI563-rfe
|
|||
|
:A -E 9.3=z10+b3.MI563-rfe
|
|||
|
:A -E 22.6=z10+b3.HO561-ham
|
|||
|
:AN -E 22.7=z10+b3.HO561-com
|
|||
|
PB 31 -PB31 IO HO561 SCALE 3 C:ZONE10ST.S5D LEN=223
|
|||
|
Page 3
|
|||
|
:AN -S 22.6=z10+b3.HO561-ham
|
|||
|
:AN -S 22.7=z10+b3.HO561-com
|
|||
|
:O
|
|||
|
:A -A 8.7=z10+b3.MI583-fco
|
|||
|
:A -E 22.7=z10+b3.HO561-com
|
|||
|
:AN -E 22.6=z10+b3.HO561-ham
|
|||
|
:AN -S 22.6=z10+b3.HO561-ham
|
|||
|
:AN -S 22.7=z10+b3.HO561-com
|
|||
|
: *(6) o a12.4
|
|||
|
:= -ME31.7 SCALE_DISCH REL.
|
|||
|
:***
|
|||
|
|
|||
|
F 31.6 = ME31.6 PLI_DISCHARG.RUN *(6)
|
|||
|
Q 9.3 = A 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
I 9.3 = E 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
I 22.6 = E 22.6=z10+b3.HO561-ham hammer mill request HO 561
|
|||
|
I 22.7 = E 22.7=z10+b3.HO561-com cone mill request HO 561
|
|||
|
S 22.6 = S 22.6=z10+b3.HO561-ham hammer mill request HO 561
|
|||
|
S 22.7 = S 22.7=z10+b3.HO561-com cone mill request HO 561
|
|||
|
Q 8.7 = A 8.7=z10+b3.MI583-fco frequ.converter MI release MI 583
|
|||
|
F 31.7 = ME31.7 SCALE_DISCH REL.
|
|||
|
|
|||
|
DX 201 = DX201 PL6-10HO561,BD560 PL6:RES PL7-9:UNIT HO561 PL10:UNIT BD560
|
|||
|
|
|||
|
Segment 6 load step index register
|
|||
|
:JU -FB177 LOAD DW DIREKT
|
|||
|
Name :LADE DW
|
|||
|
DB : KF +201
|
|||
|
DW : KF +103
|
|||
|
DBDX : KS DX
|
|||
|
:T FW 194 charge SI
|
|||
|
:
|
|||
|
:JU -FB177 LOAD DW DIREKT
|
|||
|
Name :LADE DW
|
|||
|
DB : KF +201
|
|||
|
DW : KF +153
|
|||
|
DBDX : KS DX
|
|||
|
:T FW 196 discharge SI
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 177 = FB177 LOAD DW DIREKT sp
|
|||
|
|
|||
|
Segment 7 Write motor outputs
|
|||
|
:JU -FB31 HO561 SCALE3:DR540
|
|||
|
Name :WAAGE
|
|||
|
LINR : KF +3
|
|||
|
WANR : KF +1
|
|||
|
WZNR : KF +3
|
|||
|
T1 : KF +70
|
|||
|
T2 : KF +71
|
|||
|
T3 : KF +72
|
|||
|
T4 : KF +73
|
|||
|
T5 : KF +74
|
|||
|
T6 : KF +75
|
|||
|
T7 : KF +76
|
|||
|
T8 : KF +77
|
|||
|
T9 : KF +78
|
|||
|
T10 : KF +79
|
|||
|
AF/J : KS N
|
|||
|
PWDT : KF +138
|
|||
|
PWFU : KF +0
|
|||
|
CPSI : FW 194
|
|||
|
ECSI : -M 42.6 HO561 EOF CHA SI
|
|||
|
PB 31 -PB31 IO HO561 SCALE 3 C:ZONE10ST.S5D LEN=223
|
|||
|
Page 4
|
|||
|
DPSI : FW 196
|
|||
|
EDSI : -M 42.7 HO561 EOF DIS SI
|
|||
|
EMPY : -M 43.0 HO561 EMPTY-RANG
|
|||
|
:***
|
|||
|
|
|||
|
F 42.6 = M 42.6 HO561 EOF CHA SI
|
|||
|
F 42.7 = M 42.7 HO561 EOF DIS SI
|
|||
|
F 43.0 = M 43.0 HO561 EMPTY-RANG
|
|||
|
|
|||
|
FB 31 = FB31 HO561 SCALE3:DR540 HO561 area 3 scale 3: from dryer
|
|||
|
|
|||
|
Segment 8 Write outputs
|
|||
|
:A -MA24.0 VACUUMPUMP ON
|
|||
|
:AN -S 9.1=z10+b3.HO561-vac
|
|||
|
:AN -M 61.1 MILL ACTIVE *(4) NO mill active
|
|||
|
:AN -M 61.2 MAT. IN HO563 *(4) NO material in HO563
|
|||
|
:= -A 9.1=z10+b3.HO561-vac
|
|||
|
:
|
|||
|
:A -MA24.0 VACUUMPUMP ON
|
|||
|
:AN -S 9.0=z10+b3.HO561-vac
|
|||
|
:= -A 9.0=z10+b3.HO561-vac
|
|||
|
:
|
|||
|
:A -MA24.1 VIBRATOR ON
|
|||
|
:AN -S 9.2=z10+b3.HO561-vi:
|
|||
|
:= -A 9.2=z10+b3.HO561-vi:
|
|||
|
:***
|
|||
|
|
|||
|
F 24.0 = MA24.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
S 9.1 = S 9.1=z10+b3.HO561-vac vacuumpump 1 on HO 561
|
|||
|
F 61.1 = M 61.1 MILL ACTIVE
|
|||
|
F 61.2 = M 61.2 MAT. IN HO563
|
|||
|
Q 9.1 = A 9.1=z10+b3.HO561-vac vacuumpump 1 on HO 561
|
|||
|
S 9.0 = S 9.0=z10+b3.HO561-vac vacuumpump 2 on HO 561
|
|||
|
Q 9.0 = A 9.0=z10+b3.HO561-vac vacuumpump 2 on HO 561
|
|||
|
F 24.1 = MA24.1 VIBRATOR ON
|
|||
|
S 9.2 = S 9.2=z10+b3.HO561-vi: vibrator on HO 561
|
|||
|
Q 9.2 = A 9.2=z10+b3.HO561-vi: vibrator on HO 561
|
|||
|
|
|||
|
Segment 9 Write outputs
|
|||
|
:A -MA24.2 UNLOAD VALVE CON
|
|||
|
:= -A 12.5=z10+b3.HO561-anv
|
|||
|
:
|
|||
|
:A -MA24.5 OUTLETFLAP OPEN
|
|||
|
:= -A 12.4=z10+b3.HO561-ofl
|
|||
|
:S -M 165.5 HO561 DISCH ROK
|
|||
|
:
|
|||
|
:A -MA25.2 FILTER 1 ON
|
|||
|
:= -A 19.1=z10+b3.HO561-paf
|
|||
|
:
|
|||
|
:A -MA25.3 FILTER 2 ON
|
|||
|
:= -A 19.2=z10+b3.HO561-paf
|
|||
|
:
|
|||
|
:A -MA25.4 FILTER 3 ON
|
|||
|
:= -A 19.3=z10+b3.HO561-paf
|
|||
|
:
|
|||
|
:A -MA28.0 COMPONENT VAL 1
|
|||
|
:= -A 12.3=z10+b3.HO561-tdP
|
|||
|
:
|
|||
|
:AN -A 7.5=z10+b3.HO584-vac
|
|||
|
:AN -A 9.0=z10+b3.HO561-vac
|
|||
|
:AN -A 9.1=z10+b3.HO561-vac
|
|||
|
:= -A 12.1=MV645313-fav
|
|||
|
:***
|
|||
|
|
|||
|
PB 31 -PB31 IO HO561 SCALE 3 C:ZONE10ST.S5D LEN=223
|
|||
|
Page 5
|
|||
|
F 24.2 = MA24.2 UNLOAD VALVE CON
|
|||
|
Q 12.5 = A 12.5=z10+b3.HO561-anv angle valve 1O2I Air open HO 561
|
|||
|
F 24.5 = MA24.5 OUTLETFLAP OPEN
|
|||
|
Q 12.4 = A 12.4=z10+b3.HO561-ofl outletflap 1O2I open HO 561
|
|||
|
F 165.5 = M 165.5 HO561 DISCH ROK enable reports
|
|||
|
F 25.2 = MA25.2 FILTER 1 ON
|
|||
|
Q 19.1 = A 19.1=z10+b3.HO561-paf purged air filter 1 on HO 561
|
|||
|
F 25.3 = MA25.3 FILTER 2 ON
|
|||
|
Q 19.2 = A 19.2=z10+b3.HO561-paf purged air filter 2 on HO 561
|
|||
|
F 25.4 = MA25.4 FILTER 3 ON
|
|||
|
Q 19.3 = A 19.3=z10+b3.HO561-paf purged air filter 3 on HO 561
|
|||
|
F 28.0 = MA28.0 COMPONENT VAL 1
|
|||
|
Q 12.3 = A 12.3=z10+b3.HO561-tdP tube diverter 1O2I P position 1 HO 561
|
|||
|
Q 7.5 = A 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
Q 9.0 = A 9.0=z10+b3.HO561-vac vacuumpump 2 on HO 561
|
|||
|
Q 9.1 = A 9.1=z10+b3.HO561-vac vacuumpump 1 on HO 561
|
|||
|
Q 12.1 = A 12.1=MV645313-fav air bleed valve open
|
|||
|
|
|||
|
Segment 10 Reset outputs
|
|||
|
:A -A 12.3=z10+b3.HO561-tdP *(6)
|
|||
|
:R -A 7.1=z10+b3.DR540-fco *(6)
|
|||
|
:
|
|||
|
:A -A 12.3=z10+b3.HO561-tdP
|
|||
|
:L KT 002.2 *(2)
|
|||
|
:SD -T76 HO561 OFF-del FE540 *(2)
|
|||
|
:
|
|||
|
:A -T76 HO561 OFF-del FE540 *(2)
|
|||
|
:R -A 7.0=z10+b3.DR540-rfe
|
|||
|
:***
|
|||
|
|
|||
|
Q 12.3 = A 12.3=z10+b3.HO561-tdP tube diverter 1O2I P position 1 HO 561
|
|||
|
Q 7.1 = A 7.1=z10+b3.DR540-fco frequ.converter release DR 540
|
|||
|
T 76 = T76 HO561 OFF-del FE540 HO561 OFF-delay rot.feeder DR540 *(2)
|
|||
|
Q 7.0 = A 7.0=z10+b3.DR540-rfe rotary feeder on DR 540
|
|||
|
|
|||
|
Segment 11 faults scale
|
|||
|
:A -M 18.6 PRESSURE_FAULT
|
|||
|
:= -M 40.1 HO561 PRES.FAULT
|
|||
|
:
|
|||
|
:C -DB103 SCALE 03 (WORK)
|
|||
|
:O D 191.8
|
|||
|
:O D 192.8
|
|||
|
:O D 192.9
|
|||
|
:O D 192.10
|
|||
|
:O D 192.11
|
|||
|
:O D 192.12
|
|||
|
:O D 192.13
|
|||
|
:O D 192.14
|
|||
|
:= -M 41.1 HO561 WEIG.FAULT
|
|||
|
:BE
|
|||
|
|
|||
|
F 18.6 = M 18.6 PRESSURE_FAULT
|
|||
|
F 40.1 = M 40.1 HO561 PRES.FAULT
|
|||
|
F 41.1 = M 41.1 HO561 WEIG.FAULT
|
|||
|
|
|||
|
DB 103 = DB103 SCALE 03 (WORK) working DB plc scale RAM
|
|||
|
|
|||
|
PB 41 -PB41 IO HO580 SCALE 4 C:ZONE10ST.S5D LEN=188
|
|||
|
Page 1
|
|||
|
Segment 1 detect broken wire 4-20 mA
|
|||
|
:C -DB104 SCALE 04 (WORK)
|
|||
|
:L DD 67
|
|||
|
:L KG +3000000+03
|
|||
|
:<G
|
|||
|
:S D 64.15
|
|||
|
:
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
DB 104 = DB104 SCALE 04 (WORK) working DB plc scale RAM
|
|||
|
|
|||
|
Segment 2
|
|||
|
:C -DB41 HO580 SCALE4:BD560
|
|||
|
:***
|
|||
|
|
|||
|
DB 41 = DB41 HO580 SCALE4:BD560 HO580 area 2 scale 4: from blender
|
|||
|
|
|||
|
Segment 3 Load inputs
|
|||
|
:A -E 21.6=z10+b3.HO580-exh
|
|||
|
:AN -S 21.6=z10+b3.HO580-exh
|
|||
|
:= -ME26.0 VACUUMPUMP ON
|
|||
|
:
|
|||
|
:A -E 16.0=z10+b3.HO580-dse
|
|||
|
:AN -S 12.0=z10+b3.HO580-dse
|
|||
|
:AN -S 16.0=z10+b3.HO580-dse
|
|||
|
:= -ME26.6 DOCKING DEVIC UP
|
|||
|
:
|
|||
|
:A -E 20.2=z10+b3.HO580-bin
|
|||
|
:AN -S 20.2=z10+b3.HO580-bin
|
|||
|
:= -ME26.7 CONTAINER OK
|
|||
|
:
|
|||
|
:A -E 12.0=z10+b3.HO580-dse
|
|||
|
:AN -S 12.0=z10+b3.HO580-dse
|
|||
|
:AN -S 16.0=z10+b3.HO580-dse
|
|||
|
:= -ME27.0 DOCKING DEV DOWN
|
|||
|
:***
|
|||
|
|
|||
|
I 21.6 = E 21.6=z10+b3.HO580-exh exhaust Pfc on HO 580
|
|||
|
S 21.6 = S 21.6=z10+b3.HO580-exh exhaust Pfc on HO 580
|
|||
|
F 26.0 = ME26.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
I 16.0 = E 16.0=z10+b3.HO580-dse docking seal deflate HO 580
|
|||
|
S 12.0 = S 12.0=z10+b3.HO580-dse docking seal inflate HO 580
|
|||
|
S 16.0 = S 16.0=z10+b3.HO580-dse docking seal deflate HO 580
|
|||
|
F 26.6 = ME26.6 DOCKING DEVIC UP
|
|||
|
I 20.2 = E 20.2=z10+b3.HO580-bin bin available HO 580
|
|||
|
S 20.2 = S 20.2=z10+b3.HO580-bin bin available HO 580
|
|||
|
F 26.7 = ME26.7 CONTAINER OK
|
|||
|
I 12.0 = E 12.0=z10+b3.HO580-dse docking seal inflate HO 580
|
|||
|
F 27.0 = ME27.0 DOCKING DEV DOWN
|
|||
|
|
|||
|
Segment 4 Load inputs
|
|||
|
:L DW 50 *(6)
|
|||
|
:L KF +5 *(6)
|
|||
|
:!=F *(6)
|
|||
|
:= F 200.0 *(6) silo 5: blender
|
|||
|
:
|
|||
|
:O -M 60.5 DIS.TIME OVER BL
|
|||
|
:O -M 162.3 BD560 UNIT_IDLE
|
|||
|
:A F 200.0 *(6) silo 5: blender
|
|||
|
:ON F 200.0 *(6) silo 5: blender
|
|||
|
:= -ME27.6 SILO EMPTY
|
|||
|
:
|
|||
|
:A -M 0.1 CONSTANT 1
|
|||
|
PB 41 -PB41 IO HO580 SCALE 4 C:ZONE10ST.S5D LEN=188
|
|||
|
Page 2
|
|||
|
:= -ME31.3 REL CTRL-FINE
|
|||
|
:***
|
|||
|
|
|||
|
F 60.5 = M 60.5 DIS.TIME OVER BL
|
|||
|
F 162.3 = M 162.3 BD560 UNIT_IDLE
|
|||
|
F 27.6 = ME27.6 SILO EMPTY (6)* name changed
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 31.3 = ME31.3 REL CTRL-FINE
|
|||
|
|
|||
|
Segment 5 load step index register
|
|||
|
:JU -FB177 LOAD DW DIREKT
|
|||
|
Name :LADE DW
|
|||
|
DB : KF +200
|
|||
|
DW : KF +203
|
|||
|
DBDX : KS DX
|
|||
|
:T FW 194 charge SI
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T FW 196 no discharge phase
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 177 = FB177 LOAD DW DIREKT sp
|
|||
|
|
|||
|
Segment 6
|
|||
|
:JU -FB41 HO580 SCALE4:BD560
|
|||
|
Name :WAAGE
|
|||
|
LINR : KF +4
|
|||
|
WANR : KF +1
|
|||
|
WZNR : KF +4
|
|||
|
T1 : KF +67
|
|||
|
T2 : KF +68
|
|||
|
T3 : KF +69
|
|||
|
CPSI : FW 194
|
|||
|
ECSI : -M 42.3 HO580 EOF CHA SI
|
|||
|
DPSI : FW 196
|
|||
|
EMPY : -M 42.5 HO580 EMPTY-RANG
|
|||
|
:***
|
|||
|
|
|||
|
F 42.3 = M 42.3 HO580 EOF CHA SI
|
|||
|
F 42.5 = M 42.5 HO580 EMPTY-RANG
|
|||
|
|
|||
|
FB 41 = FB41 HO580 SCALE4:BD560 HO580 area 3 scale 4: from blender
|
|||
|
|
|||
|
Segment 7 Scale HO561: Abbort Discharg*(6)
|
|||
|
:CX -DX200 PL1-5 MX520,HO580 *(6) Total network inserted!
|
|||
|
:AN D 210.0 ABORT BY PLI HO580_CHARGE
|
|||
|
:AN D 210.1 HOLD BY PLI HO580_CHARGE
|
|||
|
:AN D 211.3 ABORTED TO PLI HO580_CHARGE
|
|||
|
:AN D 211.0 HELD TO PLI HO580_CHARGE
|
|||
|
:A -MA15.4 POS.COMPO.ACTIVE
|
|||
|
:A -MA17.1 HEAL/E.SUCK. ACT
|
|||
|
:S -M 59.6 ABORT HO561_DISC
|
|||
|
:
|
|||
|
:A -MA24.0 VACUUMPUMP ON weighing active
|
|||
|
:R D 211.0 HELD TO PLI HO580_CHARGE
|
|||
|
:
|
|||
|
:C -DB103 SCALE 03 (WORK)
|
|||
|
:AN D 191.0 KEbene aktiv
|
|||
|
:A -M 59.6 ABORT HO561_DISC
|
|||
|
:R -M 59.6 ABORT HO561_DISC
|
|||
|
:***
|
|||
|
|
|||
|
F 15.4 = MA15.4 POS.COMPO.ACTIVE plc scale AST 1
|
|||
|
PB 41 -PB41 IO HO580 SCALE 4 C:ZONE10ST.S5D LEN=188
|
|||
|
Page 3
|
|||
|
F 17.1 = MA17.1 HEAL/E.SUCK. ACT plc scale AST 2
|
|||
|
F 59.6 = M 59.6 ABORT HO561_DISC *(6)
|
|||
|
F 24.0 = MA24.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
|
|||
|
DB 103 = DB103 SCALE 03 (WORK) working DB plc scale RAM
|
|||
|
|
|||
|
DX 200 = DX200 PL1-5 MX520,HO580 PL1-3: UNIT MX520 PL4,5: UNIT HO580
|
|||
|
|
|||
|
Segment 8 write outputs
|
|||
|
:C -DB41 HO580 SCALE4:BD560
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 151
|
|||
|
AUSG : -MW186 DW_ADDRESS
|
|||
|
:
|
|||
|
:A -M 62.1 STRT DINOP BD560
|
|||
|
:A -A 22.3=z10+b3.BD560-dis
|
|||
|
:ON -E 16.0=z10+b3.HO580-dse
|
|||
|
:O -MA24.0 VACUUMPUMP ON
|
|||
|
:= -M 66.1 BD560 STR ON DIS *(5)
|
|||
|
: *(5)
|
|||
|
:A -M 66.1 BD560 STR ON DIS *(5)
|
|||
|
:L -MW186 DW_ADDRESS
|
|||
|
:SF -T59 HO580 heel exhaust
|
|||
|
:
|
|||
|
:A -T59 HO580 heel exhaust
|
|||
|
:= -A 18.7=z10+b3.HO580-exh
|
|||
|
:***
|
|||
|
|
|||
|
FW 186 = MW186 DW_ADDRESS
|
|||
|
F 62.1 = M 62.1 STRT DINOP BD560
|
|||
|
Q 22.3 = A 22.3=z10+b3.BD560-dis discharge active BD 560
|
|||
|
I 16.0 = E 16.0=z10+b3.HO580-dse docking seal deflate HO 580
|
|||
|
F 24.0 = MA24.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
F 66.1 = M 66.1 BD560 STR ON DIS *(5)
|
|||
|
T 59 = T59 HO580 heel exhaust HO580 heel time exhaust on
|
|||
|
Q 18.7 = A 18.7=z10+b3.HO580-exh exhaust Pfc on HO 580
|
|||
|
|
|||
|
DB 41 = DB41 HO580 SCALE4:BD560 HO580 area 2 scale 4: from blender
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 9 faults scale
|
|||
|
:A -MA24.0 VACUUMPUMP ON
|
|||
|
:AN -E 20.2=z10+b3.HO580-bin
|
|||
|
:= -M 50.4 HO580 FAULT BIN
|
|||
|
:***
|
|||
|
|
|||
|
F 24.0 = MA24.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
I 20.2 = E 20.2=z10+b3.HO580-bin bin available HO 580
|
|||
|
F 50.4 = M 50.4 HO580 FAULT BIN
|
|||
|
|
|||
|
Segment 10 faults scale
|
|||
|
:C -DB102 SCALE 02 (WORK)
|
|||
|
:O D 191.8
|
|||
|
:O D 192.8
|
|||
|
:O D 192.9
|
|||
|
:O D 192.10
|
|||
|
:O D 192.11
|
|||
|
:O D 192.12
|
|||
|
:O D 192.13
|
|||
|
:O D 192.14
|
|||
|
:= -M 41.2 HO580 WEIG.FAULT
|
|||
|
PB 41 -PB41 IO HO580 SCALE 4 C:ZONE10ST.S5D LEN=188
|
|||
|
Page 4
|
|||
|
:***
|
|||
|
|
|||
|
F 41.2 = M 41.2 HO580 WEIG.FAULT
|
|||
|
|
|||
|
DB 102 = DB102 SCALE 02 (WORK) working DB plc scale RAM
|
|||
|
|
|||
|
Segment 11 docking inflate
|
|||
|
:C -DB41 HO580 SCALE4:BD560
|
|||
|
:A -M 62.1 STRT DINOP BD560
|
|||
|
:A -A 22.3=z10+b3.BD560-dis
|
|||
|
:O -MA24.6 ENABLE DOCKING D
|
|||
|
:A -E 23.1=z10+b3.HO580-do:
|
|||
|
: *(6) u e15.1
|
|||
|
: *(6) uns11.1
|
|||
|
: *(6) uns15.1
|
|||
|
:S -A 12.0=z10+b3.HO580-dse
|
|||
|
:
|
|||
|
:A -E 23.0=z10+b3.HO580-do:
|
|||
|
:AN -E 23.1=z10+b3.HO580-do:
|
|||
|
:AN -MA24.6 ENABLE DOCKING D
|
|||
|
:AN -M 61.1 MILL ACTIVE *(6) u e15.1
|
|||
|
:AN -M 61.2 MAT. IN HO563 *(6) uns11.1
|
|||
|
:AN -M 61.3 MAT. IN HO584 *(6) uns15.1
|
|||
|
:R -A 12.0=z10+b3.HO580-dse
|
|||
|
:***
|
|||
|
|
|||
|
F 62.1 = M 62.1 STRT DINOP BD560
|
|||
|
Q 22.3 = A 22.3=z10+b3.BD560-dis discharge active BD 560
|
|||
|
F 24.6 = MA24.6 ENABLE DOCKING D
|
|||
|
I 23.1 = E 23.1=z10+b3.HO580-do: docking inflate HO 580
|
|||
|
Q 12.0 = A 12.0=z10+b3.HO580-dse docking seal inflate HO 580
|
|||
|
I 23.0 = E 23.0=z10+b3.HO580-do: docking deflate HO 580
|
|||
|
F 61.1 = M 61.1 MILL ACTIVE
|
|||
|
F 61.2 = M 61.2 MAT. IN HO563
|
|||
|
F 61.3 = M 61.3 MAT. IN HO584
|
|||
|
|
|||
|
DB 41 = DB41 HO580 SCALE4:BD560 HO580 area 2 scale 4: from blender
|
|||
|
|
|||
|
Segment 12 *(1) docking deflate
|
|||
|
:AN -A 12.0=z10+b3.HO580-dse *(1) Total network inserted
|
|||
|
:AN -E 16.0=z10+b3.HO580-dse *(1)
|
|||
|
:= -A 16.0=z10+b3.HO580-dse *(1)
|
|||
|
:***
|
|||
|
|
|||
|
Q 12.0 = A 12.0=z10+b3.HO580-dse docking seal inflate HO 580
|
|||
|
I 16.0 = E 16.0=z10+b3.HO580-dse docking seal deflate HO 580
|
|||
|
Q 16.0 = A 16.0=z10+b3.HO580-dse docking seal deflate HO 580
|
|||
|
|
|||
|
Segment 13 lamps
|
|||
|
:A -MA24.0 VACUUMPUMP ON
|
|||
|
:AN -MA25.7 REGISTRATION ACT
|
|||
|
:O -M 4.5 GLOBAL LAMBTEST
|
|||
|
:= -A 22.1=z10+b2.HO580-wgh
|
|||
|
:
|
|||
|
:O -E 12.0=z10+b3.HO580-dse
|
|||
|
:O -M 4.5 GLOBAL LAMBTEST
|
|||
|
:= -A 23.1=z10+b2.HO580-do:
|
|||
|
:
|
|||
|
:O -E 16.0=z10+b3.HO580-dse
|
|||
|
:O -M 4.5 GLOBAL LAMBTEST
|
|||
|
:= -A 23.0=z10+b2.HO580-do:
|
|||
|
:
|
|||
|
:L DW 50 *(6)
|
|||
|
:L KF +5 *(6)
|
|||
|
PB 41 -PB41 IO HO580 SCALE 4 C:ZONE10ST.S5D LEN=188
|
|||
|
Page 5
|
|||
|
:><F *(6) silo >< blender
|
|||
|
:R -M 66.1 BD560 STR ON DIS *(6)
|
|||
|
:BE
|
|||
|
|
|||
|
F 24.0 = MA24.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
F 25.7 = MA25.7 REGISTRATION ACT
|
|||
|
F 4.5 = M 4.5 GLOBAL LAMBTEST
|
|||
|
Q 22.1 = A 22.1=z10+b2.HO580-wgh weighing active HO 580
|
|||
|
I 12.0 = E 12.0=z10+b3.HO580-dse docking seal inflate HO 580
|
|||
|
Q 23.1 = A 23.1=z10+b2.HO580-do: docking inflate HO 580
|
|||
|
I 16.0 = E 16.0=z10+b3.HO580-dse docking seal deflate HO 580
|
|||
|
Q 23.0 = A 23.0=z10+b2.HO580-do: docking deflate HO 580
|
|||
|
F 66.1 = M 66.1 BD560 STR ON DIS *(5)
|
|||
|
|
|||
|
PB 193 -PB193 CP535 C:ZONE10ST.S5D LEN=19
|
|||
|
Page 1
|
|||
|
Segment 1 CP143 Receive-All
|
|||
|
:JU -FB127 UP ACTIV 135U
|
|||
|
Name :REC-A
|
|||
|
SSNR : KY 0,4 Addressed by = 64
|
|||
|
A-NR : KY 0,0
|
|||
|
ANZW : FW 250
|
|||
|
PAFE : FY 255 MB 255 PAFE-Byte
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 127 = FB127 UP ACTIV 135U
|
|||
|
|
|||
|
Segment 2 CP143 Send-All
|
|||
|
:JU -FB126 ACTIVE 135U
|
|||
|
Name :SEND-A
|
|||
|
SSNR : KY 0,4 Addressed by = 64
|
|||
|
A-NR : KY 0,0
|
|||
|
ANZW : FW 250
|
|||
|
PAFE : FY 255 MB 255 PAFE-Byte
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 126 = FB126 ACTIVE 135U
|
|||
|
|
|||
|
FB 1 -FB 1 RUN UP C:ZONE10ST.S5D LEN=43
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
Name :RUN UP
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2 run up in cycle program
|
|||
|
:AN -M 1.2 RUN UP OB
|
|||
|
:BEC
|
|||
|
:***
|
|||
|
|
|||
|
F 1.2 = M 1.2 RUN UP OB
|
|||
|
|
|||
|
Segment 3 create DB's
|
|||
|
:L KB 1
|
|||
|
:JU -OB122:FREEZE ALARMS
|
|||
|
:
|
|||
|
:JU -FB170 CREATE DB START U
|
|||
|
Name :DB-ERZ
|
|||
|
:
|
|||
|
:JU -FB186 CREATE SCALE DBs
|
|||
|
Name :WS-ERZ.
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 170 = FB170 CREATE DB START U plc scale HKT sa
|
|||
|
FB 186 = FB186 CREATE SCALE DBs plc scale
|
|||
|
|
|||
|
OB 122 = OB122:FREEZE ALARMS
|
|||
|
|
|||
|
Segment 4 initialise stack
|
|||
|
:
|
|||
|
:JU -FB167 INIT STACK
|
|||
|
Name :ST-INI
|
|||
|
:
|
|||
|
:***
|
|||
|
|
|||
|
FB 167 = FB167 INIT STACK al
|
|||
|
|
|||
|
Segment 5 synchronize CP's
|
|||
|
:JU -FB125 SYNCHRON 135U
|
|||
|
Name :SYNCHRON CP 1430 ( H1-Bus )
|
|||
|
SSNR : KY 0,4
|
|||
|
BLGR : KY 0,255
|
|||
|
PAFE : FY 255
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 125 = FB125 SYNCHRON 135U
|
|||
|
|
|||
|
Segment 6 L2-Bus simulation
|
|||
|
: ky 0,200 0,0 mb255
|
|||
|
:
|
|||
|
:***
|
|||
|
|
|||
|
Segment 7
|
|||
|
:L KB 2
|
|||
|
:JU -OB122:FREEZE ALARMS
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
OB 122 = OB122:FREEZE ALARMS
|
|||
|
|
|||
|
Segment 8 Anlaufkennung ruecksetzen
|
|||
|
:A -M 1.2 RUN UP OB
|
|||
|
FB 1 -FB 1 RUN UP C:ZONE10ST.S5D LEN=43
|
|||
|
Page 2
|
|||
|
:R -M 1.2 RUN UP OB
|
|||
|
:BE
|
|||
|
|
|||
|
F 1.2 = M 1.2 RUN UP OB
|
|||
|
|
|||
|
FB 2 -FB 2 SERVICEMODE RSVIEW C:ZONE10ST.S5D LEN=650
|
|||
|
Page 1
|
|||
|
Segment 1 service mode
|
|||
|
Name :SERVICE
|
|||
|
|
|||
|
:C -DB5 GLOBAL DATA
|
|||
|
:***
|
|||
|
|
|||
|
DB 5 = DB5 GLOBAL DATA
|
|||
|
|
|||
|
Segment 2 Init Service-mode: reset DW's
|
|||
|
:L DW 0 INIT Service-mode
|
|||
|
:L KS IN
|
|||
|
:!=F
|
|||
|
:JC =M001 no init
|
|||
|
:L KF +96
|
|||
|
:T FW 200 DB96
|
|||
|
:L KF +0
|
|||
|
:T FW 202 dw0
|
|||
|
:L KF +255
|
|||
|
:T FW 204 dw255
|
|||
|
:JU -FB138 RESERVE DWs
|
|||
|
Name :DB-VORBE
|
|||
|
DBNR : FW 200
|
|||
|
VON : FW 202
|
|||
|
BIS : FW 204
|
|||
|
LAEN : FW 200
|
|||
|
L-B : KS BI
|
|||
|
WERT : KH 0000
|
|||
|
DBDX : KS DB
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
FB 138 = FB138 RESERVE DWs 23.11.95 UR
|
|||
|
|
|||
|
Segment 3 Init Service-mode finished
|
|||
|
:L DW 0
|
|||
|
:L KS IN
|
|||
|
:!=F
|
|||
|
:JC =M001
|
|||
|
:A -M 1.3 RUN UP INIT.
|
|||
|
:R -M 1.3 RUN UP INIT.
|
|||
|
:L KF +0 *(5) One empty row deleted!
|
|||
|
:CX -DX30 DR540 DRYER A 2&3
|
|||
|
:T DW 7 analog v. freq.conv. DR540
|
|||
|
:C -DB11 HO500 SCALE1:HO50X
|
|||
|
:T DW 146 analog v. freq.conv. HO500
|
|||
|
:C -DB30 BD560 BLENDER
|
|||
|
:T DW 50 analog v. freq.conv. MI583
|
|||
|
:T DW 51 analog v. freq.conv. FE583
|
|||
|
:T DW 52 *(5) analog v. freq.conv. BD560
|
|||
|
M001 :
|
|||
|
:C -DB5 GLOBAL DATA
|
|||
|
:L KS IN
|
|||
|
:T DW 0
|
|||
|
:*** Init Service-mode
|
|||
|
|
|||
|
F 1.3 = M 1.3 RUN UP INIT.
|
|||
|
|
|||
|
DB 11 = DB11 HO500 SCALE1:HO50X HO500 area 1 scale 1: ingredient weighin
|
|||
|
DB 30 = DB30 BD560 BLENDER
|
|||
|
DB 5 = DB5 GLOBAL DATA
|
|||
|
|
|||
|
DX 30 = DX30 DR540 DRYER A 2&3 DR540 area 2 & 3: line dryer
|
|||
|
|
|||
|
Segment 4 Reset Service-mode outputs
|
|||
|
FB 2 -FB 2 SERVICEMODE RSVIEW C:ZONE10ST.S5D LEN=650
|
|||
|
Page 2
|
|||
|
:C -DB96 OUTPUTS SERVICE M.
|
|||
|
:
|
|||
|
:AN -E 6.2=z10+b1.HO500-fco
|
|||
|
:R D 3.10 Service: release freq.conv.HO500
|
|||
|
:
|
|||
|
:AN -E 7.1=z10+b3.DR540-fco
|
|||
|
:R D 3.1 Service: release freq.conv.DR540
|
|||
|
:
|
|||
|
:AN -E 8.1=z10+b3.MI583-fco
|
|||
|
:R D 4.9 Service: release freq.conv.FE583
|
|||
|
:
|
|||
|
:AN -E 8.7=z10+b3.MI583-fco
|
|||
|
:R D 4.15 Service: release freq.conv.MI583
|
|||
|
: *(5)
|
|||
|
:AN -E 10.1=z10+b3.BD560-fco *(5)
|
|||
|
:R D 5.9 *(5) Service: rel.freq.con.BD560
|
|||
|
:***
|
|||
|
|
|||
|
I 6.2 = E 6.2=z10+b1.HO500-fco frequ.converter ready HO 500
|
|||
|
I 7.1 = E 7.1=z10+b3.DR540-fco frequ.converter ready DR 540
|
|||
|
I 8.1 = E 8.1=z10+b3.MI583-fco frequ.converter FE ready MI 583
|
|||
|
I 8.7 = E 8.7=z10+b3.MI583-fco frequ.converter MI ready MI 583
|
|||
|
I 10.1 = E 10.1=z10+b3.BD560-fco frequ.converter ready BD 560 *(5)
|
|||
|
|
|||
|
DB 96 = DB96 OUTPUTS SERVICE M. outputs service mode from RSView
|
|||
|
|
|||
|
Segment 5 Reset Service-mode outputs
|
|||
|
:O -A 4.1=z10+b1.HO502-rfe
|
|||
|
:O -A 4.2=z10+b1.HO503-rfe
|
|||
|
:O -A 4.4=z10+b1.HO505-dsc
|
|||
|
:O -S 4.0=z10+b1.HO501-rfe
|
|||
|
:R D 2.8 Service: rotary feeder on HO501
|
|||
|
:
|
|||
|
:O -A 4.0=z10+b1.HO501-rfe
|
|||
|
:O -A 4.2=z10+b1.HO503-rfe
|
|||
|
:O -A 4.4=z10+b1.HO505-dsc
|
|||
|
:O -S 4.1=z10+b1.HO502-rfe
|
|||
|
:R D 2.9 Service: rotary feeder on HO502
|
|||
|
:
|
|||
|
:O -A 4.0=z10+b1.HO501-rfe
|
|||
|
:O -A 4.1=z10+b1.HO502-rfe
|
|||
|
:O -A 4.4=z10+b1.HO505-dsc
|
|||
|
:O -S 4.2=z10+b1.HO503-rfe
|
|||
|
:R D 2.10 Service: rotary feeder on HO503
|
|||
|
:***
|
|||
|
|
|||
|
Q 4.1 = A 4.1=z10+b1.HO502-rfe rotary feeder on HO 502
|
|||
|
Q 4.2 = A 4.2=z10+b1.HO503-rfe rotary feeder on HO 503
|
|||
|
Q 4.4 = A 4.4=z10+b1.HO505-dsc dosing screw on HO 505
|
|||
|
S 4.0 = S 4.0=z10+b1.HO501-rfe rotary feeder on HO 501
|
|||
|
Q 4.0 = A 4.0=z10+b1.HO501-rfe rotary feeder on HO 501
|
|||
|
S 4.1 = S 4.1=z10+b1.HO502-rfe rotary feeder on HO 502
|
|||
|
S 4.2 = S 4.2=z10+b1.HO503-rfe rotary feeder on HO 503
|
|||
|
|
|||
|
Segment 6 Reset Service-mode outputs
|
|||
|
:O -A 4.0=z10+b1.HO501-rfe
|
|||
|
:O -A 4.1=z10+b1.HO502-rfe
|
|||
|
:O -A 4.2=z10+b1.HO503-rfe
|
|||
|
:O -S 4.4=z10+b1.HO505-dsc
|
|||
|
:R D 2.12 Service: rotary feeder on HO505
|
|||
|
:
|
|||
|
:A -S 5.0=z10+b1.HO501-vi:
|
|||
|
:R D 2.0 Service: vibrator on HO501
|
|||
|
:
|
|||
|
FB 2 -FB 2 SERVICEMODE RSVIEW C:ZONE10ST.S5D LEN=650
|
|||
|
Page 3
|
|||
|
:A -S 5.1=z10+b1.HO502-vi:
|
|||
|
:R D 2.1 Service: vibrator on HO502
|
|||
|
:
|
|||
|
:A -S 5.2=z10+b1.HO503-vi:
|
|||
|
:R D 2.2 Service: vibrator on HO503
|
|||
|
:
|
|||
|
:A -S 5.3=z10+b1.HO504-vi:
|
|||
|
:R D 2.3 Service: vibrator on HO504
|
|||
|
:***
|
|||
|
|
|||
|
Q 4.0 = A 4.0=z10+b1.HO501-rfe rotary feeder on HO 501
|
|||
|
Q 4.1 = A 4.1=z10+b1.HO502-rfe rotary feeder on HO 502
|
|||
|
Q 4.2 = A 4.2=z10+b1.HO503-rfe rotary feeder on HO 503
|
|||
|
S 4.4 = S 4.4=z10+b1.HO505-dsc dosing screw on HO 505
|
|||
|
S 5.0 = S 5.0=z10+b1.HO501-vi: vibrator on HO 501
|
|||
|
S 5.1 = S 5.1=z10+b1.HO502-vi: vibrator on HO 502
|
|||
|
S 5.2 = S 5.2=z10+b1.HO503-vi: vibrator on HO 503
|
|||
|
S 5.3 = S 5.3=z10+b1.HO504-vi: vibrator on HO 504
|
|||
|
|
|||
|
Segment 7 Reset Service-mode outputs
|
|||
|
:A -S 5.4=z10+b1.HO505-vi:
|
|||
|
:R D 2.4 Service: vibrator on HO505
|
|||
|
:
|
|||
|
:A -S 6.0=z10+b1.HO500-vac
|
|||
|
:R D 3.8 Service: vacuumpump on HO500
|
|||
|
:
|
|||
|
:A -S 6.1=z10+b1.piv500-va
|
|||
|
:R D 3.9 Service: vacuumpump piv on HO500
|
|||
|
:
|
|||
|
:A -S 6.4=z10+b1.HO500-vi:
|
|||
|
:R D 3.12 Service: vibrator on HO500
|
|||
|
:
|
|||
|
:A -S 6.7=z10+b1.fra505-vi
|
|||
|
:R D 3.15 Service: vibrator frame on HO505
|
|||
|
:
|
|||
|
:A -S 7.0=z10+b3.DR540-rfe
|
|||
|
:R D 3.0 Service: rotary feeder on DR540
|
|||
|
:***
|
|||
|
|
|||
|
S 5.4 = S 5.4=z10+b1.HO505-vi: vibrator on HO 505
|
|||
|
S 6.0 = S 6.0=z10+b1.HO500-vac vacuumpump on HO 500
|
|||
|
S 6.1 = S 6.1=z10+b1.piv500-va vacuumpump on pinch valve 500
|
|||
|
S 6.4 = S 6.4=z10+b1.HO500-vi: vibrator on HO 500
|
|||
|
S 6.7 = S 6.7=z10+b1.fra505-vi vibrator on frame 505
|
|||
|
S 7.0 = S 7.0=z10+b3.DR540-rfe rotary feeder on DR 540
|
|||
|
|
|||
|
Segment 8 Reset Service-mode outputs
|
|||
|
:A -S 7.5=z10+b3.HO584-vac
|
|||
|
:R D 3.5 Service: vacuumpump on HO584
|
|||
|
:
|
|||
|
:A -S 7.6=z10+b3.HO584-vi:
|
|||
|
:R D 3.6 Service: vibrator on HO584
|
|||
|
:
|
|||
|
:A -S 7.7=z10+b3.HO584-rfe
|
|||
|
:R D 3.7 Service: rotary feeder on HO584
|
|||
|
:
|
|||
|
:A -S 8.0=z10+b3.MI583-rfe
|
|||
|
:R D 4.8 Service: rotary feeder on MI583
|
|||
|
:
|
|||
|
:A -S 8.2=z10+b3.MI583-com
|
|||
|
:R D 4.10 Service: cone mill on MI583
|
|||
|
:
|
|||
|
:A -S 9.0=z10+b3.HO561-vac
|
|||
|
:R D 4.0 Service: vacuumpump 2 on HO561
|
|||
|
FB 2 -FB 2 SERVICEMODE RSVIEW C:ZONE10ST.S5D LEN=650
|
|||
|
Page 4
|
|||
|
:***
|
|||
|
|
|||
|
S 7.5 = S 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
S 7.6 = S 7.6=z10+b3.HO584-vi: vibrator on HO 584
|
|||
|
S 7.7 = S 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
S 8.0 = S 8.0=z10+b3.MI583-rfe rotary feeder on MI 583
|
|||
|
S 8.2 = S 8.2=z10+b3.MI583-com cone mill on MI 583
|
|||
|
S 9.0 = S 9.0=z10+b3.HO561-vac vacuumpump 2 on HO 561
|
|||
|
|
|||
|
Segment 9 Reset Service-mode outputs
|
|||
|
:A -S 9.1=z10+b3.HO561-vac
|
|||
|
:R D 4.1 Service: vacuumpump 1 on HO561
|
|||
|
:
|
|||
|
:A -S 9.2=z10+b3.HO561-vi:
|
|||
|
:R D 4.2 Service: vibrator on HO561
|
|||
|
:
|
|||
|
:A -S 9.3=z10+b3.MI563-rfe
|
|||
|
:R D 4.3 Service: rotary feeder on MI563
|
|||
|
:
|
|||
|
:A -S 9.4=z10+b3.MI563-ham
|
|||
|
:R D 4.4 Service: hammer mill on MI563
|
|||
|
:
|
|||
|
:A -S 9.5=z10+b3.HO563-vi:
|
|||
|
:R D 4.5 Service: vibrator on HO563
|
|||
|
:
|
|||
|
:A -S 10.0=z10+b3.BD560-rbl
|
|||
|
:R D 5.8 Service: ribbon blender on BD560
|
|||
|
:***
|
|||
|
|
|||
|
S 9.1 = S 9.1=z10+b3.HO561-vac vacuumpump 1 on HO 561
|
|||
|
S 9.2 = S 9.2=z10+b3.HO561-vi: vibrator on HO 561
|
|||
|
S 9.3 = S 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
S 9.4 = S 9.4=z10+b3.MI563-ham hammer mill on MI 563
|
|||
|
S 9.5 = S 9.5=z10+b3.HO563-vi: vibrator on HO 563
|
|||
|
S 10.0 = S 10.0=z10+b3.BD560-rbl ribbon blender on BD 560
|
|||
|
|
|||
|
Segment 10 copy DW -> AW
|
|||
|
:AN -M 1.3 RUN UP INIT.
|
|||
|
:JC -FB174 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DB
|
|||
|
DB-Q : KF +96
|
|||
|
VON : KF +2
|
|||
|
BIS : KF +13
|
|||
|
ZIEL : KS A
|
|||
|
DB-Z : KF +0
|
|||
|
NACH : KF +4
|
|||
|
FEHL : F 200.0
|
|||
|
LAEN : KF +0
|
|||
|
L-B : KS BI
|
|||
|
:***
|
|||
|
|
|||
|
F 1.3 = M 1.3 RUN UP INIT.
|
|||
|
|
|||
|
FB 174 = FB174 COPY BLOCK Parameter: D sp
|
|||
|
|
|||
|
Segment 11 read pressure scale HO500
|
|||
|
:C -DB11 HO500 SCALE1:HO50X
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T FY 180 0 =P-address
|
|||
|
:L KF +128
|
|||
|
:T FY 181
|
|||
|
:
|
|||
|
FB 2 -FB 2 SERVICEMODE RSVIEW C:ZONE10ST.S5D LEN=650
|
|||
|
Page 5
|
|||
|
:L DW 121 calibrate conveying pressure
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:O -E 6.0=z10+b1.HO500-vac
|
|||
|
:= -M 64.1 SERVM.VACT HO500
|
|||
|
:***
|
|||
|
|
|||
|
I 6.0 = E 6.0=z10+b1.HO500-vac vacuumpump on HO 500
|
|||
|
F 64.1 = M 64.1 SERVM.VACT HO500
|
|||
|
|
|||
|
DB 11 = DB11 HO500 SCALE1:HO50X HO500 area 1 scale 1: ingredient weighin
|
|||
|
|
|||
|
Segment 12 read pressure scale HO500
|
|||
|
:JU -FB118 PRESSURE TRANSMIT
|
|||
|
Name :DRUCKAUF
|
|||
|
BGRN : -MW180 PARAMETER 1
|
|||
|
OG : DW 123
|
|||
|
UG : DW 122
|
|||
|
AUSG : DW 124
|
|||
|
FEHL : F 200.0
|
|||
|
AKTV : -M 64.1 SERVM.VACT HO500
|
|||
|
TIMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
S5S7 : KS S5
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 64.1 = M 64.1 SERVM.VACT HO500
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 118 = FB118 PRESSURE TRANSMIT hkt as
|
|||
|
|
|||
|
Segment 13 pressure high
|
|||
|
:L DW 124 actual pressure
|
|||
|
:L DW 125 min pressure
|
|||
|
:>F
|
|||
|
:R -M 40.0 HO500 PRES.FAULT
|
|||
|
:
|
|||
|
:L DW 124 actual pressure
|
|||
|
:L DW 126 max pressure
|
|||
|
:<F
|
|||
|
:O F 200.0
|
|||
|
:S -M 40.0 HO500 PRES.FAULT
|
|||
|
:***
|
|||
|
|
|||
|
F 40.0 = M 40.0 HO500 PRES.FAULT
|
|||
|
|
|||
|
Segment 14 read pressure hopper HO584
|
|||
|
:C -DB30 BD560 BLENDER
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T FY 180 0 =P-address
|
|||
|
:L KF +134
|
|||
|
:T FY 181
|
|||
|
:
|
|||
|
:L DW 1 calibrate conveying pressure
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:O -E 7.5=z10+b3.HO584-vac
|
|||
|
:= -M 64.3 SERVM.VACT HO584
|
|||
|
:***
|
|||
|
|
|||
|
I 7.5 = E 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
F 64.3 = M 64.3 SERVM.VACT HO584
|
|||
|
|
|||
|
FB 2 -FB 2 SERVICEMODE RSVIEW C:ZONE10ST.S5D LEN=650
|
|||
|
Page 6
|
|||
|
DB 30 = DB30 BD560 BLENDER
|
|||
|
|
|||
|
Segment 15 read pressure hopper HO584
|
|||
|
:JU -FB118 PRESSURE TRANSMIT
|
|||
|
Name :DRUCKAUF
|
|||
|
BGRN : -MW180 PARAMETER 1
|
|||
|
OG : DW 3
|
|||
|
UG : DW 2
|
|||
|
AUSG : DW 4
|
|||
|
FEHL : F 200.0
|
|||
|
AKTV : -M 64.3 SERVM.VACT HO584
|
|||
|
TIMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
S5S7 : KS S5
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 64.3 = M 64.3 SERVM.VACT HO584
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 118 = FB118 PRESSURE TRANSMIT hkt as
|
|||
|
|
|||
|
Segment 16 pressure high
|
|||
|
:L DW 4 actual pressure
|
|||
|
:L DW 5 min pressure
|
|||
|
:>F
|
|||
|
:R -M 40.2 HO584 PRES.FAULT
|
|||
|
:
|
|||
|
:L DW 4 actual pressure
|
|||
|
:L DW 6 max pressure
|
|||
|
:<F
|
|||
|
:O F 200.0
|
|||
|
:S -M 40.2 HO584 PRES.FAULT
|
|||
|
:***
|
|||
|
|
|||
|
F 40.2 = M 40.2 HO584 PRES.FAULT
|
|||
|
|
|||
|
Segment 17 read pressure seal 1 BD560 *(5)
|
|||
|
:L KF +0 *(5) Total network inserted!
|
|||
|
:T FY 180 0 =P-address
|
|||
|
:L KF +140
|
|||
|
:T FY 181
|
|||
|
:
|
|||
|
:L DW 53 calibrate pressure seal 1
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:O -A 20.1=z10+b3.BD560-aps
|
|||
|
:= -M 65.2 SERVM.P1AC BD560
|
|||
|
:***
|
|||
|
|
|||
|
Q 20.1 = A 20.1=z10+b3.BD560-aps air purged seals 1 on BD 560 *(5)
|
|||
|
F 65.2 = M 65.2 SERVM.P1AC BD560 *(5)
|
|||
|
|
|||
|
Segment 18 read pressure seal 1 BD560 *(5)
|
|||
|
:JU -FB118 PRESSURE TRANSMIT *(5) Total network inserted!
|
|||
|
Name :DRUCKAUF
|
|||
|
BGRN : -MW180 PARAMETER 1
|
|||
|
OG : DW 55 pr. range max limit seal 1 BD560
|
|||
|
UG : DW 54 pr. range min limit seal 1 BD560
|
|||
|
AUSG : DW 56 relative pressure seal 1 BD560
|
|||
|
FEHL : F 200.0
|
|||
|
AKTV : -M 65.2 SERVM.P1AC BD560
|
|||
|
TIMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
S5S7 : KS S5
|
|||
|
:L DW 56 *(6) rel. pressure seal 1 BD560
|
|||
|
FB 2 -FB 2 SERVICEMODE RSVIEW C:ZONE10ST.S5D LEN=650
|
|||
|
Page 7
|
|||
|
:L DW 54 *(6) pr.range min li.seal1 BD560
|
|||
|
:<F *(6)
|
|||
|
:JC =M001 *(6)
|
|||
|
:L DW 56 *(6) rel. pressure seal 1 BD560
|
|||
|
:L DW 55 *(6) pr.range max li.seal1 BD560
|
|||
|
:>F *(6)
|
|||
|
:JC =M001 *(6)
|
|||
|
:JU =M002 *(6)
|
|||
|
M001 :L KF -1 *(6) val.out of range: displ. -1
|
|||
|
:T DW 56 *(6) rel. pressure seal 1 BD560
|
|||
|
M002 :L DW 56 *(6) rel. pressure seal 1 BD560
|
|||
|
:L DW 57 minimum pressure seal 1 BD560
|
|||
|
:<F
|
|||
|
:O F 200.0
|
|||
|
:A -A 20.1=z10+b3.BD560-aps
|
|||
|
:= -M 40.3 BD560 PR.F SEAL1
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 65.2 = M 65.2 SERVM.P1AC BD560 *(5)
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
Q 20.1 = A 20.1=z10+b3.BD560-aps air purged seals 1 on BD 560 *(5)
|
|||
|
F 40.3 = M 40.3 BD560 PR.F SEAL1
|
|||
|
|
|||
|
FB 118 = FB118 PRESSURE TRANSMIT hkt as
|
|||
|
|
|||
|
Segment 19 read pressure seal 2 BD560 *(5)
|
|||
|
:L KF +0 *(5) Total network inserted!
|
|||
|
:T FY 180 0 =P-address
|
|||
|
:L KF +142
|
|||
|
:T FY 181
|
|||
|
:
|
|||
|
:L DW 58 calibrate pressure seal 2
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:O -A 20.2=z10+b3.BD560-aps
|
|||
|
:= -M 65.3 SERVM.P2AC BD560
|
|||
|
:***
|
|||
|
|
|||
|
Q 20.2 = A 20.2=z10+b3.BD560-aps air purged seals 2 on BD 560 *(5)
|
|||
|
F 65.3 = M 65.3 SERVM.P2AC BD560 *(5)
|
|||
|
|
|||
|
Segment 20 read pressure seal 2 BD560 *(5)
|
|||
|
:JU -FB118 PRESSURE TRANSMIT *(5) Total network inserted!
|
|||
|
Name :DRUCKAUF
|
|||
|
BGRN : -MW180 PARAMETER 1
|
|||
|
OG : DW 60 pr. range max limit seal 2 BD560
|
|||
|
UG : DW 59 pr. range min limit seal 2 BD560
|
|||
|
AUSG : DW 61 relative pressure seal 2 BD560
|
|||
|
FEHL : F 200.0
|
|||
|
AKTV : -M 65.2 SERVM.P1AC BD560
|
|||
|
TIMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
S5S7 : KS S5
|
|||
|
:L DW 61 *(6) rel. pressure seal 2 BD560
|
|||
|
:L DW 59 *(6) pr.range min li.seal2 BD560
|
|||
|
:<F *(6)
|
|||
|
:JC =M001 *(6)
|
|||
|
:L DW 61 *(6) rel. pressure seal 2 BD560
|
|||
|
:L DW 60 *(6) pr.range max li.seal2 BD560
|
|||
|
:>F *(6)
|
|||
|
:JC =M001 *(6)
|
|||
|
:JU =M002 *(6)
|
|||
|
M001 :L KF -1 *(6) val.out of range: displ. -1
|
|||
|
:T DW 61 *(6) rel. pressure seal 2 BD560
|
|||
|
FB 2 -FB 2 SERVICEMODE RSVIEW C:ZONE10ST.S5D LEN=650
|
|||
|
Page 8
|
|||
|
M002 :L DW 61 *(6) rel. pressure seal 2 BD560
|
|||
|
:L DW 62 minimum pressure seal 2 BD560
|
|||
|
:<F
|
|||
|
:O F 200.0
|
|||
|
:A -A 20.2=z10+b3.BD560-aps
|
|||
|
:= -M 40.4 BD560 PR.F SEAL2
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 65.2 = M 65.2 SERVM.P1AC BD560 *(5)
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
Q 20.2 = A 20.2=z10+b3.BD560-aps air purged seals 2 on BD 560 *(5)
|
|||
|
F 40.4 = M 40.4 BD560 PR.F SEAL2
|
|||
|
|
|||
|
FB 118 = FB118 PRESSURE TRANSMIT hkt as
|
|||
|
|
|||
|
Segment 21 read val. freq.conv. MI583 *(5)
|
|||
|
:L KF +0 *(5) Total network inserted!
|
|||
|
:T FY 180 0= P-address
|
|||
|
:L KF +130
|
|||
|
:T FY 181
|
|||
|
:L KF +1500 *(6)
|
|||
|
:T -MW182 PARAMETER 2 Max= 1500
|
|||
|
:L KF +0
|
|||
|
:T -MW184 PARAMETER 3 Min= 0
|
|||
|
:
|
|||
|
:JU -FB118 PRESSURE TRANSMIT
|
|||
|
Name :DRUCKAUF
|
|||
|
BGRN : -MW180 PARAMETER 1
|
|||
|
OG : -MW182 PARAMETER 2
|
|||
|
UG : -MW184 PARAMETER 3
|
|||
|
AUSG : DW 63 actual speed cone mill MI583
|
|||
|
FEHL : F 200.0
|
|||
|
AKTV : -M 0.1 CONSTANT 1
|
|||
|
TIMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
S5S7 : KS S5
|
|||
|
:L DW 63 actual speed cone mill MI583
|
|||
|
:L -MW184 PARAMETER 3
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:L DW 63 actual speed cone mill MI583
|
|||
|
:L -MW182 PARAMETER 2
|
|||
|
:>F
|
|||
|
:JC =M001
|
|||
|
:JU =M002
|
|||
|
M001 :L KF -1
|
|||
|
:T DW 63 actual speed cone mill 583
|
|||
|
M002 :***
|
|||
|
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 118 = FB118 PRESSURE TRANSMIT hkt as
|
|||
|
|
|||
|
Segment 22 speed out of tol.range MI583*(5)
|
|||
|
:L DW 71 set speed cone mill MI583 in rpm
|
|||
|
:L DW 64 speed tol.cone mill MI583 in rpm
|
|||
|
:-F
|
|||
|
:L DW 63 act.speed cone mill MI583 in rpm
|
|||
|
:>F act speed < set speed - tol
|
|||
|
:= F 201.0
|
|||
|
FB 2 -FB 2 SERVICEMODE RSVIEW C:ZONE10ST.S5D LEN=650
|
|||
|
Page 9
|
|||
|
: *(5) Total network inserted
|
|||
|
:L DW 71 set speed cone mill MI583 in rpm
|
|||
|
:L DW 64 speed tol.cone mill MI583 in rpm
|
|||
|
:+F
|
|||
|
:L DW 63 act.speed cone mill MI583 in rpm
|
|||
|
:<F act speed > set speed + tol
|
|||
|
:O F 201.0 act speed < set speed - tol
|
|||
|
:O F 200.0
|
|||
|
:A -A 8.7=z10+b3.MI583-fco
|
|||
|
:L KT 080.1
|
|||
|
:SD T 202
|
|||
|
:A T 202
|
|||
|
:= -M 40.5 MI583 SPEED FAUL
|
|||
|
:***
|
|||
|
|
|||
|
Q 8.7 = A 8.7=z10+b3.MI583-fco frequ.converter MI release MI 583
|
|||
|
F 40.5 = M 40.5 MI583 SPEED FAUL
|
|||
|
|
|||
|
Segment 23 actual val. freq.conv.BD560 *(5)
|
|||
|
:L KF +0 *(5) Total network inserted!
|
|||
|
:T FY 180 0= P-address
|
|||
|
:L KF +136
|
|||
|
:T FY 181
|
|||
|
:JU -FB118 PRESSURE TRANSMIT
|
|||
|
Name :DRUCKAUF
|
|||
|
BGRN : -MW180 PARAMETER 1
|
|||
|
OG : DW 70 Max speed blender BD560
|
|||
|
UG : DW 69 Min speed blender BD560
|
|||
|
AUSG : DW 65 actual speed blender BD560
|
|||
|
FEHL : F 200.0
|
|||
|
AKTV : -M 0.1 CONSTANT 1
|
|||
|
TIMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
S5S7 : KS S5
|
|||
|
:L DW 65 actual speed blender BD560
|
|||
|
:L DW 69 Min speed blender BD560
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:L DW 65 actual speed blender BD560
|
|||
|
:L DW 70 Max speed blender BD560
|
|||
|
:>F
|
|||
|
:JC =M001
|
|||
|
:JU =M002
|
|||
|
M001 :L KF -1
|
|||
|
:T DW 65 actual speed blender BD560
|
|||
|
M002 :***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 118 = FB118 PRESSURE TRANSMIT hkt as
|
|||
|
|
|||
|
Segment 24 speed out of tol.range BD560*(5)
|
|||
|
:L DW 68 set speed blender BD560 in rpm
|
|||
|
:L DW 66 speed tol. blender BD560 in rpm
|
|||
|
:-F
|
|||
|
:L DW 65 act. speed blender BD560 in rpm
|
|||
|
:>F act speed < set speed - tol
|
|||
|
:= F 201.0
|
|||
|
: *(5) Total network inserted
|
|||
|
:L DW 68 set speed blender BD560 in rpm
|
|||
|
:L DW 66 speed tol. blender BD560 in rpm
|
|||
|
:+F
|
|||
|
:L DW 65 act. speed blender BD560 in rpm
|
|||
|
FB 2 -FB 2 SERVICEMODE RSVIEW C:ZONE10ST.S5D LEN=650
|
|||
|
Page 10
|
|||
|
:<F act speed > set speed + tol
|
|||
|
:O F 201.0 act speed < set speed - tol
|
|||
|
:O F 200.0
|
|||
|
:A -A 10.1=z10+b3.BD560-fco
|
|||
|
:L KT 080.1
|
|||
|
:SD T 201
|
|||
|
:A T 201
|
|||
|
:= -M 40.6 BD560 SPEED FAUL
|
|||
|
:***
|
|||
|
|
|||
|
Q 10.1 = A 10.1=z10+b3.BD560-fco frequ.converter release BD 560 *(5)
|
|||
|
F 40.6 = M 40.6 BD560 SPEED FAUL
|
|||
|
|
|||
|
Segment 25 read pressure scale HO561
|
|||
|
:C -DB31 HO561 SCALE3:DR540
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T FY 180 0 =P-address
|
|||
|
:L KF +138
|
|||
|
:T FY 181
|
|||
|
:
|
|||
|
:L DW 121 calibrate conveying pressure
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:O -E 9.1=z10+b3.HO561-vac
|
|||
|
:O -E 9.0=z10+b3.HO561-vac
|
|||
|
:= -M 64.2 SERVM.VACT HO561
|
|||
|
:***
|
|||
|
|
|||
|
I 9.1 = E 9.1=z10+b3.HO561-vac vacuumpump 1 on HO 561
|
|||
|
I 9.0 = E 9.0=z10+b3.HO561-vac vacuumpump 2 on HO 561
|
|||
|
F 64.2 = M 64.2 SERVM.VACT HO561
|
|||
|
|
|||
|
DB 31 = DB31 HO561 SCALE3:DR540 HO561 area 3 scale 3: from dryer
|
|||
|
|
|||
|
Segment 26 read pressure scale HO561
|
|||
|
:JU -FB118 PRESSURE TRANSMIT
|
|||
|
Name :DRUCKAUF
|
|||
|
BGRN : -MW180 PARAMETER 1
|
|||
|
OG : DW 123
|
|||
|
UG : DW 122
|
|||
|
AUSG : DW 124
|
|||
|
FEHL : F 200.0
|
|||
|
AKTV : -M 64.2 SERVM.VACT HO561
|
|||
|
TIMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
S5S7 : KS S5
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 64.2 = M 64.2 SERVM.VACT HO561
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 118 = FB118 PRESSURE TRANSMIT hkt as
|
|||
|
|
|||
|
Segment 27 pressure high
|
|||
|
:L DW 124 actual pressure
|
|||
|
:L DW 125 min pressure
|
|||
|
:>F
|
|||
|
:R -M 40.1 HO561 PRES.FAULT
|
|||
|
:
|
|||
|
:L DW 124 actual pressure
|
|||
|
:L DW 126 max pressure
|
|||
|
:<F
|
|||
|
:O F 200.0
|
|||
|
FB 2 -FB 2 SERVICEMODE RSVIEW C:ZONE10ST.S5D LEN=650
|
|||
|
Page 11
|
|||
|
:S -M 40.1 HO561 PRES.FAULT
|
|||
|
:***
|
|||
|
|
|||
|
F 40.1 = M 40.1 HO561 PRES.FAULT
|
|||
|
|
|||
|
Segment 28 set value freq.converter HO500
|
|||
|
:C -DB11 HO500 SCALE1:HO50X
|
|||
|
:L KF +128
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:AN -M 1.3 RUN UP INIT.
|
|||
|
:JC -FB251 WRIT ANALOG VALUE
|
|||
|
Name :AN-AUS
|
|||
|
APW : -MW180 PARAMETER 1
|
|||
|
OG : KG +1000000+04
|
|||
|
UG : KG +0000000+00
|
|||
|
AMAX : KF +1024
|
|||
|
AMIN : KF +0
|
|||
|
WERG : FD 192
|
|||
|
WERT : DW 146
|
|||
|
G/F : KS F
|
|||
|
IN : KS IN
|
|||
|
FORM : KS ..
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 1.3 = M 1.3 RUN UP INIT.
|
|||
|
|
|||
|
DB 11 = DB11 HO500 SCALE1:HO50X HO500 area 1 scale 1: ingredient weighin
|
|||
|
|
|||
|
FB 251 = FB251 WRIT ANALOG VALUE
|
|||
|
|
|||
|
Segment 29 set value freq.converter DR540
|
|||
|
:CX -DX30 DR540 DRYER A 2&3
|
|||
|
:L KF +130
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:AN -M 1.3 RUN UP INIT.
|
|||
|
:JC -FB251 WRIT ANALOG VALUE
|
|||
|
Name :AN-AUS
|
|||
|
APW : -MW180 PARAMETER 1
|
|||
|
OG : KG +1000000+04
|
|||
|
UG : KG +0000000+00
|
|||
|
AMAX : KF +1024
|
|||
|
AMIN : KF +0
|
|||
|
WERG : FD 192
|
|||
|
WERT : DW 7
|
|||
|
G/F : KS F
|
|||
|
IN : KS IN
|
|||
|
FORM : KS ..
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 1.3 = M 1.3 RUN UP INIT.
|
|||
|
|
|||
|
FB 251 = FB251 WRIT ANALOG VALUE
|
|||
|
|
|||
|
DX 30 = DX30 DR540 DRYER A 2&3 DR540 area 2 & 3: line dryer
|
|||
|
|
|||
|
Segment 30 set value freq.converter MI583
|
|||
|
:C -DB30 BD560 BLENDER
|
|||
|
:L KF +132
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
FB 2 -FB 2 SERVICEMODE RSVIEW C:ZONE10ST.S5D LEN=650
|
|||
|
Page 12
|
|||
|
:AN -M 1.3 RUN UP INIT.
|
|||
|
:JC -FB251 WRIT ANALOG VALUE
|
|||
|
Name :AN-AUS
|
|||
|
APW : -MW180 PARAMETER 1
|
|||
|
OG : KG +1000000+04
|
|||
|
UG : KG +0000000+00
|
|||
|
AMAX : KF +1024
|
|||
|
AMIN : KF +0
|
|||
|
WERG : FD 192
|
|||
|
WERT : DW 51
|
|||
|
G/F : KS F
|
|||
|
IN : KS IN
|
|||
|
FORM : KS ..
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 1.3 = M 1.3 RUN UP INIT.
|
|||
|
|
|||
|
DB 30 = DB30 BD560 BLENDER
|
|||
|
|
|||
|
FB 251 = FB251 WRIT ANALOG VALUE
|
|||
|
|
|||
|
Segment 31 set value freq.converter FE583
|
|||
|
:L KF +134
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:AN -M 1.3 RUN UP INIT.
|
|||
|
:JC -FB251 WRIT ANALOG VALUE
|
|||
|
Name :AN-AUS
|
|||
|
APW : -MW180 PARAMETER 1
|
|||
|
OG : KG +1000000+04
|
|||
|
UG : KG +0000000+00
|
|||
|
AMAX : KF +1024
|
|||
|
AMIN : KF +0
|
|||
|
WERG : FD 192
|
|||
|
WERT : DW 50
|
|||
|
G/F : KS F
|
|||
|
IN : KS IN
|
|||
|
FORM : KS ..
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 1.3 = M 1.3 RUN UP INIT.
|
|||
|
|
|||
|
FB 251 = FB251 WRIT ANALOG VALUE
|
|||
|
|
|||
|
Segment 32 set value freq.conv. BD560 *(5)
|
|||
|
:L KF +136 *(5) Total network inserted
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:AN -M 1.3 RUN UP INIT.
|
|||
|
:JC -FB251 WRIT ANALOG VALUE
|
|||
|
Name :AN-AUS
|
|||
|
APW : -MW180 PARAMETER 1
|
|||
|
OG : KG +1000000+04
|
|||
|
UG : KG +0000000+00
|
|||
|
AMAX : KF +1024
|
|||
|
AMIN : KF +0
|
|||
|
WERG : FD 192
|
|||
|
WERT : DW 52
|
|||
|
G/F : KS F
|
|||
|
IN : KS IN
|
|||
|
FORM : KS ..
|
|||
|
:BE
|
|||
|
FB 2 -FB 2 SERVICEMODE RSVIEW C:ZONE10ST.S5D LEN=650
|
|||
|
Page 13
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 1.3 = M 1.3 RUN UP INIT.
|
|||
|
|
|||
|
FB 251 = FB251 WRIT ANALOG VALUE
|
|||
|
|
|||
|
FB 3 -FB 3 FAULT EVALUATION C:ZONE10ST.S5D LEN=390
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
Name :FAULT EV
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2 Collective fault receipt
|
|||
|
:C -DB5 GLOBAL DATA
|
|||
|
:
|
|||
|
:A D 2.0 collective fault receipt by View
|
|||
|
:= -M 3.6
|
|||
|
:S -M 2.5
|
|||
|
:
|
|||
|
:AN -M 2.5
|
|||
|
:JC =M001
|
|||
|
:L DW 6 counter fault receipt
|
|||
|
:L KF +16
|
|||
|
:>=F
|
|||
|
:R -M 2.5
|
|||
|
:R D 2.0
|
|||
|
:L DW 6
|
|||
|
:L KF +16
|
|||
|
:><F
|
|||
|
:JC =M002
|
|||
|
:L KF +192
|
|||
|
:T DW 7 erase counter collective receipt
|
|||
|
M003 :
|
|||
|
:L DW 7 Am Ende des Sammelquittungs-
|
|||
|
:T FW 200 durchlaufs werden alle Quit.
|
|||
|
:C -DB100 FAULT EVALUATION wieder geloescht
|
|||
|
:L KM 00000000 00000000 ==> auf DW 192 bis DW255 in den
|
|||
|
:DO FW 200 Stoer-DB wird Null geschrieben
|
|||
|
:T DW 0 (sonst bleibt Quit. bei
|
|||
|
: vorhandener Diskrepanz stehen
|
|||
|
: und Stoerung wird nach
|
|||
|
:C -DB5 GLOBAL DATA Beseitigung der Diskrepanz
|
|||
|
: geloescht)
|
|||
|
:L FW 200
|
|||
|
:L KF +255
|
|||
|
:>=F
|
|||
|
:JC =M002
|
|||
|
:L DW 7
|
|||
|
:L KF +1
|
|||
|
:+F
|
|||
|
:T DW 7 erase counter collective receipt
|
|||
|
:JU =M003
|
|||
|
M002 :
|
|||
|
:L DW 6 counter fault receipt
|
|||
|
:L KF +1
|
|||
|
:+F
|
|||
|
:T DW 6 counter fault receipt
|
|||
|
M001 :
|
|||
|
:A -M 2.5
|
|||
|
:JC =M004
|
|||
|
:L KF +0
|
|||
|
:T DW 6 counter fault receipt
|
|||
|
M004 :***
|
|||
|
|
|||
|
F 3.6 = M 3.6
|
|||
|
F 2.5 = M 2.5
|
|||
|
|
|||
|
DB 5 = DB5 GLOBAL DATA
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
Segment 3 DB100 Bereich 0 DW 0 -15
|
|||
|
FB 3 -FB 3 FAULT EVALUATION C:ZONE10ST.S5D LEN=390
|
|||
|
Page 2
|
|||
|
:JU -FB100 COLLECTIVE FAULT
|
|||
|
Name :FE-ERSTW
|
|||
|
SAST : -M 2.2 COL.FAULT DB100
|
|||
|
QUIT : -M 2.4
|
|||
|
ANFW : KF +0
|
|||
|
ENDW : KF +15
|
|||
|
DB1 : -DB100 FAULT EVALUATION
|
|||
|
DB2 : -DB99 FAULT EVALUATION
|
|||
|
BER : KF +0
|
|||
|
ERST : -M 2.3 FIRST NOT. DB100
|
|||
|
AUTQ : -M 2.5
|
|||
|
T-NR : KF +0
|
|||
|
AEND : -M 2.0 MODIFICAT. DB100
|
|||
|
QAEN : -M 2.1 RECEIPT.MOD.DB100
|
|||
|
TOFF : KF +0
|
|||
|
:***
|
|||
|
|
|||
|
F 2.2 = M 2.2 COL.FAULT DB100 general fault
|
|||
|
F 2.4 = M 2.4
|
|||
|
F 2.3 = M 2.3 FIRST NOT. DB100 general fualt
|
|||
|
F 2.5 = M 2.5
|
|||
|
F 2.0 = M 2.0 MODIFICAT. DB100 general fault
|
|||
|
F 2.1 = M 2.1 RECEIPT.MOD.DB100 general fault
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
DB 99 = DB99 FAULT EVALUATION helper DB for FB 100
|
|||
|
|
|||
|
FB 100 = FB100 COLLECTIVE FAULT cont.control DB100(area by area) HKT al
|
|||
|
|
|||
|
Segment 4 DB100 Bereich 1 DW 16-31
|
|||
|
:JU -FB100 COLLECTIVE FAULT
|
|||
|
Name :FE-ERSTW
|
|||
|
SAST : -M 2.6
|
|||
|
QUIT : -M 2.4
|
|||
|
ANFW : KF +16
|
|||
|
ENDW : KF +31
|
|||
|
DB1 : -DB100 FAULT EVALUATION
|
|||
|
DB2 : -DB99 FAULT EVALUATION
|
|||
|
BER : KF +1
|
|||
|
ERST : -M 2.7
|
|||
|
AUTQ : -M 2.5
|
|||
|
T-NR : KF +0
|
|||
|
AEND : -M 2.0 MODIFICAT. DB100
|
|||
|
QAEN : -M 2.1 RECEIPT.MOD.DB100
|
|||
|
TOFF : KF +0
|
|||
|
:***
|
|||
|
|
|||
|
F 2.6 = M 2.6
|
|||
|
F 2.4 = M 2.4
|
|||
|
F 2.7 = M 2.7
|
|||
|
F 2.5 = M 2.5
|
|||
|
F 2.0 = M 2.0 MODIFICAT. DB100 general fault
|
|||
|
F 2.1 = M 2.1 RECEIPT.MOD.DB100 general fault
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
DB 99 = DB99 FAULT EVALUATION helper DB for FB 100
|
|||
|
|
|||
|
FB 100 = FB100 COLLECTIVE FAULT cont.control DB100(area by area) HKT al
|
|||
|
|
|||
|
Segment 5 DB100 Bereich 2 DW 32-47
|
|||
|
:JU -FB100 COLLECTIVE FAULT
|
|||
|
Name :FE-ERSTW
|
|||
|
SAST : -M 3.2 COL.FAULT DB100
|
|||
|
QUIT : -M 2.4
|
|||
|
FB 3 -FB 3 FAULT EVALUATION C:ZONE10ST.S5D LEN=390
|
|||
|
Page 3
|
|||
|
ANFW : KF +32
|
|||
|
ENDW : KF +47
|
|||
|
DB1 : -DB100 FAULT EVALUATION
|
|||
|
DB2 : -DB99 FAULT EVALUATION
|
|||
|
BER : KF +2
|
|||
|
ERST : -M 3.3 FIRST NOT. DB100
|
|||
|
AUTQ : -M 2.5
|
|||
|
T-NR : KF +0
|
|||
|
AEND : -M 2.0 MODIFICAT. DB100
|
|||
|
QAEN : -M 2.1 RECEIPT.MOD.DB100
|
|||
|
TOFF : KF +0
|
|||
|
:***
|
|||
|
|
|||
|
F 3.2 = M 3.2 COL.FAULT DB100 extrem fault
|
|||
|
F 2.4 = M 2.4
|
|||
|
F 3.3 = M 3.3 FIRST NOT. DB100 extrem fault
|
|||
|
F 2.5 = M 2.5
|
|||
|
F 2.0 = M 2.0 MODIFICAT. DB100 general fault
|
|||
|
F 2.1 = M 2.1 RECEIPT.MOD.DB100 general fault
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
DB 99 = DB99 FAULT EVALUATION helper DB for FB 100
|
|||
|
|
|||
|
FB 100 = FB100 COLLECTIVE FAULT cont.control DB100(area by area) HKT al
|
|||
|
|
|||
|
Segment 6 DB100 Bereich 3 DW 48-63
|
|||
|
:JU -FB100 COLLECTIVE FAULT
|
|||
|
Name :FE-ERSTW
|
|||
|
SAST : -M 3.4
|
|||
|
QUIT : -M 2.4
|
|||
|
ANFW : KF +48
|
|||
|
ENDW : KF +63
|
|||
|
DB1 : -DB100 FAULT EVALUATION
|
|||
|
DB2 : -DB99 FAULT EVALUATION
|
|||
|
BER : KF +3
|
|||
|
ERST : -M 3.5
|
|||
|
AUTQ : -M 2.5
|
|||
|
T-NR : KF +0
|
|||
|
AEND : -M 2.0 MODIFICAT. DB100
|
|||
|
QAEN : -M 2.1 RECEIPT.MOD.DB100
|
|||
|
TOFF : KF +0
|
|||
|
:***
|
|||
|
|
|||
|
F 3.4 = M 3.4
|
|||
|
F 2.4 = M 2.4
|
|||
|
F 3.5 = M 3.5
|
|||
|
F 2.5 = M 2.5
|
|||
|
F 2.0 = M 2.0 MODIFICAT. DB100 general fault
|
|||
|
F 2.1 = M 2.1 RECEIPT.MOD.DB100 general fault
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
DB 99 = DB99 FAULT EVALUATION helper DB for FB 100
|
|||
|
|
|||
|
FB 100 = FB100 COLLECTIVE FAULT cont.control DB100(area by area) HKT al
|
|||
|
|
|||
|
Segment 7 Sammelstoerlampe
|
|||
|
:O -M 2.2 COL.FAULT DB100
|
|||
|
:O -M 2.6
|
|||
|
:O -M 3.2 COL.FAULT DB100
|
|||
|
:O -M 3.4
|
|||
|
:= F 200.0
|
|||
|
:***
|
|||
|
|
|||
|
F 2.2 = M 2.2 COL.FAULT DB100 general fault
|
|||
|
FB 3 -FB 3 FAULT EVALUATION C:ZONE10ST.S5D LEN=390
|
|||
|
Page 4
|
|||
|
F 2.6 = M 2.6
|
|||
|
F 3.2 = M 3.2 COL.FAULT DB100 extrem fault
|
|||
|
F 3.4 = M 3.4
|
|||
|
|
|||
|
Segment 8 fault P-Bereich in S-flags
|
|||
|
:C -DB100 FAULT EVALUATION
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T -MW178 LOOP COUNTER FB3
|
|||
|
:
|
|||
|
M001 :L -MW178 LOOP COUNTER FB3
|
|||
|
:L KF +2
|
|||
|
:XF
|
|||
|
:T FW 200
|
|||
|
:
|
|||
|
:DO -MW178 LOOP COUNTER FB3
|
|||
|
:L DW 0
|
|||
|
:DO FW 200
|
|||
|
:T SW 0
|
|||
|
:
|
|||
|
:L -MW178 LOOP COUNTER FB3
|
|||
|
:ADD KF +1
|
|||
|
:T -MW178 LOOP COUNTER FB3
|
|||
|
:
|
|||
|
:L -MW178 LOOP COUNTER FB3
|
|||
|
:L KF +64
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:***
|
|||
|
|
|||
|
FW 178 = MW178 LOOP COUNTER FB3
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
Segment 9 scale faults HO500 *(6)
|
|||
|
:C -DB101 SCALE 01 (WORK) *(6) Total network inserted !
|
|||
|
:L DL 192
|
|||
|
:T -MB 101 SCALE 1 FAULTS
|
|||
|
:A D 191.8
|
|||
|
:= -M 101.7 SC1 BROKEN WIRE
|
|||
|
:
|
|||
|
:C -DB103 SCALE 03 (WORK)
|
|||
|
:L DL 192
|
|||
|
:T -MB 103 SCALE 3 FAULTS
|
|||
|
:A D 191.8
|
|||
|
:= -M 103.7 SC3 BROKEN WIRE
|
|||
|
:
|
|||
|
:C -DB104 SCALE 04 (WORK)
|
|||
|
:L DL 192
|
|||
|
:T -MB 104 SCALE 4 FAULTS
|
|||
|
:A D 191.8
|
|||
|
:= -M 104.7 SC4 BROKEN WIRE
|
|||
|
:***
|
|||
|
|
|||
|
FY 101 = MB 101 SCALE 1 FAULTS *(6)
|
|||
|
F 101.7 = M 101.7 SC1 BROKEN WIRE *(6) acknowledge scale 1 broken wire fau
|
|||
|
FY 103 = MB 103 SCALE 3 FAULTS *(6)
|
|||
|
F 103.7 = M 103.7 SC3 BROKEN WIRE *(6) acknowledge scale 3 broken wire fau
|
|||
|
FY 104 = MB 104 SCALE 4 FAULTS *(6)
|
|||
|
F 104.7 = M 104.7 SC4 BROKEN WIRE *(6) acknowledge scale 4 broken wire fau
|
|||
|
|
|||
|
DB 101 = DB101 SCALE 01 (WORK) working DB plc scale RAM
|
|||
|
DB 103 = DB103 SCALE 03 (WORK) working DB plc scale RAM
|
|||
|
DB 104 = DB104 SCALE 04 (WORK) working DB plc scale RAM
|
|||
|
FB 3 -FB 3 FAULT EVALUATION C:ZONE10ST.S5D LEN=390
|
|||
|
Page 5
|
|||
|
Segment 10 ack scale faults HO500
|
|||
|
:C -DB208 CONTROL DB PLC SC *(6)
|
|||
|
:A -M 101.0 SC1 DOS.TIMEOUT *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 1.8 *(6)
|
|||
|
:AN -M 101.0 SC1 DOS.TIMEOUT *(6)
|
|||
|
:R D 1.8 *(6)
|
|||
|
:
|
|||
|
:A -M 101.1 SC1 TOLERANCE F *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 1.9 *(6)
|
|||
|
:AN -M 101.1 SC1 TOLERANCE F *(6)
|
|||
|
:R D 1.9 *(6)
|
|||
|
:
|
|||
|
:A -M 101.2 SC1 DIS.TIM.OVE *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 1.10 *(6)
|
|||
|
:AN -M 101.2 SC1 DIS.TIM.OVE *(6)
|
|||
|
:R D 1.10 *(6)
|
|||
|
:*** *(6)
|
|||
|
|
|||
|
F 101.0 = M 101.0 SC1 DOS.TIMEOUT *(6) acknowledge scale 1 dosing timeout
|
|||
|
F 3.6 = M 3.6
|
|||
|
F 101.1 = M 101.1 SC1 TOLERANCE F *(6) acknowledge scale 1 tolerance fault
|
|||
|
F 101.2 = M 101.2 SC1 DIS.TIM.OVE *(6) ackn. scale 1 discharge time overfl
|
|||
|
|
|||
|
DB 208 = DB208 CONTROL DB PLC SC control bits PC<->PLC plc scale RAM
|
|||
|
|
|||
|
Segment 11 ack scale faults HO500
|
|||
|
:A -M 101.3 SC1 RELEASE FAU *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 1.11 *(6)
|
|||
|
:AN -M 101.3 SC1 RELEASE FAU *(6)
|
|||
|
:R D 1.11 *(6)
|
|||
|
:
|
|||
|
:A -M 101.4 SC1 OVERLOAD *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 1.12 *(6)
|
|||
|
:AN -M 101.4 SC1 OVERLOAD *(6)
|
|||
|
:R D 1.12 *(6)
|
|||
|
:
|
|||
|
:A -M 101.5 SC1 HEEL T.HIGH *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 1.13 *(6)
|
|||
|
:AN -M 101.5 SC1 HEEL T.HIGH *(6)
|
|||
|
:R D 1.13 *(6)
|
|||
|
:*** *(6)
|
|||
|
|
|||
|
F 101.3 = M 101.3 SC1 RELEASE FAU *(6) acknowledge scale 1 release fault
|
|||
|
F 3.6 = M 3.6
|
|||
|
F 101.4 = M 101.4 SC1 OVERLOAD *(6) acknowledge scale 1 overload
|
|||
|
F 101.5 = M 101.5 SC1 HEEL T.HIGH *(6) acknowledge scale 1 heel to high
|
|||
|
|
|||
|
Segment 12 ack scale faults HO500 *(6)
|
|||
|
:A -M 101.6 SC1 THROUGHPUT *(6) Total network inserted !
|
|||
|
:A -M 3.6
|
|||
|
:S D 1.14
|
|||
|
:AN -M 101.6 SC1 THROUGHPUT
|
|||
|
:R D 1.14
|
|||
|
:
|
|||
|
:A -M 101.7 SC1 BROKEN WIRE
|
|||
|
:A -M 3.6
|
|||
|
:S D 0.8
|
|||
|
:AN -M 101.7 SC1 BROKEN WIRE
|
|||
|
FB 3 -FB 3 FAULT EVALUATION C:ZONE10ST.S5D LEN=390
|
|||
|
Page 6
|
|||
|
:R D 0.8
|
|||
|
:***
|
|||
|
|
|||
|
F 101.6 = M 101.6 SC1 THROUGHPUT *(6) acknowledge scale 1 throughput faul
|
|||
|
F 3.6 = M 3.6
|
|||
|
F 101.7 = M 101.7 SC1 BROKEN WIRE *(6) acknowledge scale 1 broken wire fau
|
|||
|
|
|||
|
Segment 13 ack scale faults HO561
|
|||
|
:A -M 103.0 SC3 DOS.TIMEOUT *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 5.8 *(6)
|
|||
|
:AN -M 103.0 SC3 DOS.TIMEOUT *(6)
|
|||
|
:R D 5.8 *(6)
|
|||
|
:
|
|||
|
:A -M 103.1 SC3 TOLERANCE F *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 5.9 *(6)
|
|||
|
:AN -M 103.1 SC3 TOLERANCE F *(6)
|
|||
|
:R D 5.9 *(6)
|
|||
|
:
|
|||
|
:A -M 103.2 SC3 DIS.TIM.OVE *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 5.10 *(6)
|
|||
|
:AN -M 103.2 SC3 DIS.TIM.OVE *(6)
|
|||
|
:R D 5.10 *(6)
|
|||
|
:*** *(6)
|
|||
|
|
|||
|
F 103.0 = M 103.0 SC3 DOS.TIMEOUT *(6) acknowledge scale 3 dosing timeout
|
|||
|
F 3.6 = M 3.6
|
|||
|
F 103.1 = M 103.1 SC3 TOLERANCE F *(6) acknowledge scale 3 tolerance fault
|
|||
|
F 103.2 = M 103.2 SC3 DIS.TIM.OVE *(6) ackn. scale 3 discharge time overfl
|
|||
|
|
|||
|
Segment 14 ack scale faults HO561
|
|||
|
:A -M 103.3 SC3 RELEASE FAU *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 5.11 *(6)
|
|||
|
:AN -M 103.3 SC3 RELEASE FAU *(6)
|
|||
|
:R D 5.11 *(6)
|
|||
|
:
|
|||
|
:A -M 103.4 SC3 OVERLOAD *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 5.12 *(6)
|
|||
|
:AN -M 103.4 SC3 OVERLOAD *(6)
|
|||
|
:R D 5.12 *(6)
|
|||
|
:
|
|||
|
:A -M 103.5 SC3 HEEL T.HIGH *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 5.13 *(6)
|
|||
|
:AN -M 103.5 SC3 HEEL T.HIGH *(6)
|
|||
|
:R D 5.13 *(6)
|
|||
|
:*** *(6)
|
|||
|
|
|||
|
F 103.3 = M 103.3 SC3 RELEASE FAU *(6) acknowledge scale 3 release fault
|
|||
|
F 3.6 = M 3.6
|
|||
|
F 103.4 = M 103.4 SC3 OVERLOAD *(6) acknowledge scale 3 overload
|
|||
|
F 103.5 = M 103.5 SC3 HEEL T.HIGH *(6) acknowledge scale 3 heel to high
|
|||
|
|
|||
|
Segment 15 ack scale faults HO561 *(6)
|
|||
|
:A -M 103.6 SC3 THROUGHPUT *(6) Total network inserted !
|
|||
|
:A -M 3.6
|
|||
|
:S D 5.14
|
|||
|
:AN -M 103.6 SC3 THROUGHPUT
|
|||
|
:R D 5.14
|
|||
|
:
|
|||
|
FB 3 -FB 3 FAULT EVALUATION C:ZONE10ST.S5D LEN=390
|
|||
|
Page 7
|
|||
|
:A -M 103.7 SC3 BROKEN WIRE
|
|||
|
:A -M 3.6
|
|||
|
:S D 4.8
|
|||
|
:AN -M 103.7 SC3 BROKEN WIRE
|
|||
|
:R D 4.8
|
|||
|
:***
|
|||
|
|
|||
|
F 103.6 = M 103.6 SC3 THROUGHPUT *(6) acknowledge scale 3 throughput faul
|
|||
|
F 3.6 = M 3.6
|
|||
|
F 103.7 = M 103.7 SC3 BROKEN WIRE *(6) acknowledge scale 3 broken wire fau
|
|||
|
|
|||
|
Segment 16 ack scale faults HO580
|
|||
|
:A -M 104.0 SC4 DOS.TIMEOUT *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 7.8 *(6)
|
|||
|
:AN -M 104.0 SC4 DOS.TIMEOUT
|
|||
|
:R D 7.8
|
|||
|
:
|
|||
|
:A -M 104.1 SC4 TOLERANCE F *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 7.9 *(6)
|
|||
|
:AN -M 104.1 SC4 TOLERANCE F *(6)
|
|||
|
:R D 7.9 *(6)
|
|||
|
:
|
|||
|
:A -M 104.2 SC4 DIS.TIM.OVE *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 7.10 *(6)
|
|||
|
:AN -M 104.2 SC4 DIS.TIM.OVE *(6)
|
|||
|
:R D 7.10 *(6)
|
|||
|
:*** *(6)
|
|||
|
|
|||
|
F 104.0 = M 104.0 SC4 DOS.TIMEOUT *(6) acknowledge scale 4 dosing timeout
|
|||
|
F 3.6 = M 3.6
|
|||
|
F 104.1 = M 104.1 SC4 TOLERANCE F *(6) acknowledge scale 4 tolerance fault
|
|||
|
F 104.2 = M 104.2 SC4 DIS.TIM.OVE *(6) ackn. scale 4 discharge time overfl
|
|||
|
|
|||
|
Segment 17 ack scale faults HO580
|
|||
|
:A -M 104.3 SC4 RELEASE FAU *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 7.11 *(6)
|
|||
|
:AN -M 104.3 SC4 RELEASE FAU *(6)
|
|||
|
:R D 7.11 *(6)
|
|||
|
:
|
|||
|
:A -M 104.4 SC4 OVERLOAD *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 7.12 *(6)
|
|||
|
:AN -M 104.4 SC4 OVERLOAD *(6)
|
|||
|
:S D 7.12 *(6)
|
|||
|
:
|
|||
|
:A -M 104.5 SC4 HEEL T.HIGH *(6)
|
|||
|
:A -M 3.6
|
|||
|
:S D 7.13 *(6)
|
|||
|
:AN -M 104.5 SC4 HEEL T.HIGH *(6)
|
|||
|
:R D 7.13 *(6)
|
|||
|
:*** *(6)
|
|||
|
|
|||
|
F 104.3 = M 104.3 SC4 RELEASE FAU *(6) acknowledge scale 4 release fault
|
|||
|
F 3.6 = M 3.6
|
|||
|
F 104.4 = M 104.4 SC4 OVERLOAD *(6) acknowledge scale 4 overload
|
|||
|
F 104.5 = M 104.5 SC4 HEEL T.HIGH *(6) acknowledge scale 4 heel to high
|
|||
|
|
|||
|
Segment 18 ack scale faults HO580 *(6)
|
|||
|
:A -M 104.6 SC4 THROUGHPUT *(6) Total network inserted !
|
|||
|
:A -M 3.6
|
|||
|
FB 3 -FB 3 FAULT EVALUATION C:ZONE10ST.S5D LEN=390
|
|||
|
Page 8
|
|||
|
:S D 7.14
|
|||
|
:AN -M 104.6 SC4 THROUGHPUT
|
|||
|
:R D 7.14
|
|||
|
:
|
|||
|
:A -M 104.7 SC4 BROKEN WIRE
|
|||
|
:A -M 3.6
|
|||
|
:S D 6.8
|
|||
|
:AN -M 104.7 SC4 BROKEN WIRE
|
|||
|
:R D 6.8
|
|||
|
:***
|
|||
|
|
|||
|
F 104.6 = M 104.6 SC4 THROUGHPUT *(6) acknowledge scale 4 throughput faul
|
|||
|
F 3.6 = M 3.6
|
|||
|
F 104.7 = M 104.7 SC4 BROKEN WIRE *(6) acknowledge scale 4 broken wire fau
|
|||
|
|
|||
|
Segment 19 fault control voltage on
|
|||
|
:C -DB100 FAULT EVALUATION
|
|||
|
:A D 0.7 fault: control voltage off
|
|||
|
:= -S 22.0=z10.PLC-cvo:on
|
|||
|
:BE
|
|||
|
|
|||
|
S 22.0 = S 22.0=z10.PLC-cvo:on control voltage on PLC
|
|||
|
|
|||
|
DB 100 = DB100 FAULT EVALUATION create fault messages RAM
|
|||
|
|
|||
|
FB 4 -FB 4 C:ZONE10ST.S5D LEN=32
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
Name :RES OUTP
|
|||
|
|
|||
|
:AN -S 25.0=z10+DKC.HO500-ea
|
|||
|
:O -M 0.1 CONSTANT 1
|
|||
|
:AN -S 22.0=z10.PLC-cvo:on
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T QW 4
|
|||
|
:T QW 6
|
|||
|
:T QW 8
|
|||
|
:T QW 10
|
|||
|
:T QW 12
|
|||
|
:T QW 14
|
|||
|
:T QW 16
|
|||
|
:T QW 18
|
|||
|
:T QW 20
|
|||
|
:T QW 22
|
|||
|
:T QW 24
|
|||
|
:T QW 26
|
|||
|
M001 :BE
|
|||
|
|
|||
|
S 25.0 = S 25.0=z10+DKC.HO500-ea earth monitoring 9 healthy HO 500
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
S 22.0 = S 22.0=z10.PLC-cvo:on control voltage on PLC
|
|||
|
|
|||
|
FB 5 -FB 5 C:ZONE10ST.S5D LEN=117
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
Name :CAL.PRES
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2
|
|||
|
:C -DB11 HO500 SCALE1:HO50X
|
|||
|
:
|
|||
|
:L DW 121
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:= F 200.0
|
|||
|
:
|
|||
|
:ON F 200.0
|
|||
|
:O -M 64.5 CAL.PRESS. HO500
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KF -1000
|
|||
|
:T DW 122
|
|||
|
:L KF +1000
|
|||
|
:T DW 123
|
|||
|
M001 :
|
|||
|
:A F 200.0
|
|||
|
:= -M 64.5 CAL.PRESS. HO500
|
|||
|
:***
|
|||
|
|
|||
|
F 64.5 = M 64.5 CAL.PRESS. HO500
|
|||
|
|
|||
|
DB 11 = DB11 HO500 SCALE1:HO50X HO500 area 1 scale 1: ingredient weighin
|
|||
|
|
|||
|
Segment 3
|
|||
|
:C -DB31 HO561 SCALE3:DR540
|
|||
|
:
|
|||
|
:L DW 121
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:= F 200.0
|
|||
|
:
|
|||
|
:ON F 200.0
|
|||
|
:O -M 64.6 CAL.PRESS. HO561
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KF -1000
|
|||
|
:T DW 122
|
|||
|
:L KF +1000
|
|||
|
:T DW 123
|
|||
|
M001 :
|
|||
|
:A F 200.0
|
|||
|
:= -M 64.6 CAL.PRESS. HO561
|
|||
|
:***
|
|||
|
|
|||
|
F 64.6 = M 64.6 CAL.PRESS. HO561
|
|||
|
|
|||
|
DB 31 = DB31 HO561 SCALE3:DR540 HO561 area 3 scale 3: from dryer
|
|||
|
|
|||
|
Segment 4
|
|||
|
:C -DB30 BD560 BLENDER
|
|||
|
:
|
|||
|
:L DW 1
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:= F 200.0
|
|||
|
:
|
|||
|
:ON F 200.0
|
|||
|
FB 5 -FB 5 C:ZONE10ST.S5D LEN=117
|
|||
|
Page 2
|
|||
|
:O -M 64.7 CAL.PRESS. HO584
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KF -1000
|
|||
|
:T DW 2
|
|||
|
:L KF +1000
|
|||
|
:T DW 3
|
|||
|
M001 :
|
|||
|
:A F 200.0
|
|||
|
:= -M 64.7 CAL.PRESS. HO584
|
|||
|
:***
|
|||
|
|
|||
|
F 64.7 = M 64.7 CAL.PRESS. HO584
|
|||
|
|
|||
|
DB 30 = DB30 BD560 BLENDER
|
|||
|
|
|||
|
Segment 5
|
|||
|
:L DW 53
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:= F 200.0
|
|||
|
:
|
|||
|
:ON F 200.0
|
|||
|
:O -M 65.6 CAL.PRESS1 BD560
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KF -1000
|
|||
|
:T DW 54
|
|||
|
:L KF +1000
|
|||
|
:T DW 55
|
|||
|
M001 :
|
|||
|
:A F 200.0
|
|||
|
:= -M 65.6 CAL.PRESS1 BD560
|
|||
|
:***
|
|||
|
|
|||
|
F 65.6 = M 65.6 CAL.PRESS1 BD560 *(5)
|
|||
|
|
|||
|
Segment 6
|
|||
|
:L DW 58
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:= F 200.0
|
|||
|
:
|
|||
|
:ON F 200.0
|
|||
|
:O -M 65.7 CAL.PRESS2 BD560
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KF -1000
|
|||
|
:T DW 59
|
|||
|
:L KF +1000
|
|||
|
:T DW 60
|
|||
|
M001 :
|
|||
|
:A F 200.0
|
|||
|
:= -M 65.7 CAL.PRESS2 BD560
|
|||
|
:BE
|
|||
|
|
|||
|
F 65.7 = M 65.7 CAL.PRESS2 BD560 *(5)
|
|||
|
|
|||
|
FB 6 -FB 6 PRESSURE TRANSMIT. C:ZONE10ST.S5D LEN=128
|
|||
|
Page 1
|
|||
|
Segment 1 Drucktransmitter
|
|||
|
|
|||
|
Name :DRUCKTRS
|
|||
|
Decl :ABSO I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :MEMO I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :RELA I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :MIND I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :MAXD I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :FREI I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :TERR I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :DRST I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :SFDF I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KS
|
|||
|
Decl :TAKT I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
|
|||
|
:A F 255.0 Ruecksetzen der Schmiermerker
|
|||
|
:R F 255.0
|
|||
|
:
|
|||
|
:A F 255.1
|
|||
|
:R F 255.1
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 2 Memory-Feld
|
|||
|
:O =FREI Freigabe fuer Geblaese
|
|||
|
:JC =M001 =>Memory-Feld nicht aktualis.
|
|||
|
:
|
|||
|
:L =ABSO Absolut-Druck laden
|
|||
|
:L =MEMO Memory-Feld laden
|
|||
|
:<=F
|
|||
|
:JC =M002
|
|||
|
:AN F 255.0
|
|||
|
:S F 255.0 =>Memory-Feld + 1
|
|||
|
:
|
|||
|
M002 :>=F
|
|||
|
:JC =M001
|
|||
|
:AN F 255.1
|
|||
|
:S F 255.1 =>Memory-Feld - 1
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 3 Memory-Feld berechnen
|
|||
|
:O =FREI Freigabe fuer Geblaese
|
|||
|
:ON =TAKT oder kein Sekundenimpuls
|
|||
|
:JC =M001 =>Memory-Feld nicht aktualis.
|
|||
|
:
|
|||
|
:A F 255.0
|
|||
|
:JC =M002
|
|||
|
:A F 255.1
|
|||
|
:JC =M003
|
|||
|
:JU =M001
|
|||
|
:
|
|||
|
M002 :L =MEMO
|
|||
|
:L KF +1
|
|||
|
:+F
|
|||
|
:T =MEMO =>MEMO = MEMO + 1
|
|||
|
:JU =M001
|
|||
|
:
|
|||
|
M003 :L =MEMO
|
|||
|
:L KF -1
|
|||
|
:+F
|
|||
|
:T =MEMO
|
|||
|
: =>MEMO = MEMO -1
|
|||
|
M001 :***
|
|||
|
FB 6 -FB 6 PRESSURE TRANSMIT. C:ZONE10ST.S5D LEN=128
|
|||
|
Page 2
|
|||
|
Segment 4 Relativdruck berechnen
|
|||
|
:L =ABSO Absolutdruck
|
|||
|
:L =MEMO -Memorydruck
|
|||
|
:-F =============
|
|||
|
:T =RELA Relativdruck
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 5 Min-/Maxdruck Druckfoerderung
|
|||
|
:LW =SFDF
|
|||
|
:L KS DF
|
|||
|
:><F
|
|||
|
:JC =M001 => keine Druckfoerderung
|
|||
|
:
|
|||
|
:L =RELA Relativdruck
|
|||
|
:L =MAXD Maxdruck
|
|||
|
:>=F Relativdruck>=Maxdruck
|
|||
|
:O =TERR Transmitterfehler
|
|||
|
:S =DRST =>Druckstoerung
|
|||
|
:
|
|||
|
:L =RELA Relativdruck
|
|||
|
:L =MIND Mindruck
|
|||
|
:<=F Relativdruck<=Mindruck
|
|||
|
:AN =TERR Transmitterfehler
|
|||
|
:RB =DRST =>Stoerung loeschen
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 6 Min-/Maxdruck Saugfoerderung
|
|||
|
:LW =SFDF
|
|||
|
:L KS SF
|
|||
|
:><F
|
|||
|
:JC =M001 =>keine Saugfoerderung
|
|||
|
:
|
|||
|
:L =RELA Relativdruck
|
|||
|
:L =MAXD Maxdruck
|
|||
|
:<=F Relativdruck<=Maxdruck
|
|||
|
:O =TERR Transmitterfehler
|
|||
|
:S =DRST =>Druckstoerung
|
|||
|
:
|
|||
|
:L =RELA Relativdruck
|
|||
|
:L =MIND Mindruck
|
|||
|
:>=F Relativdruck>=Mindruck
|
|||
|
:AN =TERR Transmittmrddh+<2B>
|
|||
|
:RB =DRST
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 7
|
|||
|
:BE
|
|||
|
|
|||
|
FB 7 -FB 7 C:ZONE10ST.S5D LEN=108
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
FB 8 - IMPULSZAEHLUNG SPEICHERND SE/SA STAND: 21.06.00
|
|||
|
===============================================================================
|
|||
|
***** CPU : 948 *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : 21.06.00 R.GREMMINGER
|
|||
|
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG :
|
|||
|
|
|||
|
NR. DATUM AENDERUNG BEARBEITER
|
|||
|
-------------------------------------------------------------------------------
|
|||
|
01
|
|||
|
===============================================================================
|
|||
|
SYMBOLIKDATEI : KEINE
|
|||
|
---------------
|
|||
|
|
|||
|
BAUSTEINPARAMETER :
|
|||
|
-------------------
|
|||
|
#STRT : STARTBIT FUER ZAEHLER
|
|||
|
#AKTI : COUNTER LAEUFT
|
|||
|
#AUSG : COUNTER ABGELAUFEN
|
|||
|
#SOLL : SOLLWERT
|
|||
|
#IST : ISTWERT
|
|||
|
#IMP : IMPULSSIGNAL
|
|||
|
#H-IM : HILFSMERKER IMPULSSIGNAL (FLANKENAUSWERTUNG)
|
|||
|
#DIV : DIVISOR (GEZAELTE IMPULSE DIVIDIERT DURCH #DIV ERGIEBT DEN ISTWERT)
|
|||
|
|
|||
|
LOKALE VARIABLEN :
|
|||
|
------------------
|
|||
|
KEINE VERWENDET
|
|||
|
|
|||
|
Name :COUNTER
|
|||
|
Decl :STRT I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :RSET I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :AKTI I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :AUSG I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :SOLL I/Q/D/B/T/C: I BI/BY/W/D: D
|
|||
|
Decl :H-ID I/Q/D/B/T/C: Q BI/BY/W/D: D
|
|||
|
Decl :IMP I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :H-IM I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :EINH I/Q/D/B/T/C: I BI/BY/W/D: D
|
|||
|
Decl :ISTD I/Q/D/B/T/C: Q BI/BY/W/D: D
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2
|
|||
|
:AN =RSET
|
|||
|
:JC =M001
|
|||
|
:RB =AUSG
|
|||
|
:RB =AKTI
|
|||
|
:
|
|||
|
:L KG +0000000+00
|
|||
|
:T =H-ID
|
|||
|
:T =ISTD
|
|||
|
:
|
|||
|
:BEU
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
FB 7 -FB 7 C:ZONE10ST.S5D LEN=108
|
|||
|
Page 2
|
|||
|
Segment 3
|
|||
|
|
|||
|
|
|||
|
Zaehlen :
|
|||
|
_____________
|
|||
|
STRT : __! !____
|
|||
|
________
|
|||
|
AKTI : __! !________
|
|||
|
____
|
|||
|
AUSG : ___________! !____
|
|||
|
|
|||
|
|
|||
|
SOLLWERT = ISTWERT
|
|||
|
|
|||
|
|
|||
|
:L =SOLL
|
|||
|
:L =H-ID
|
|||
|
:>G
|
|||
|
:A =STRT
|
|||
|
:= =AKTI
|
|||
|
:
|
|||
|
:A =STRT
|
|||
|
:AN =AKTI
|
|||
|
:= =AUSG
|
|||
|
:
|
|||
|
:ON =AKTI
|
|||
|
:ON =IMP
|
|||
|
:O =H-IM
|
|||
|
:JC =M001
|
|||
|
:L =H-ID
|
|||
|
:L =EINH
|
|||
|
::G
|
|||
|
:GFD
|
|||
|
:L KF +1
|
|||
|
:+F
|
|||
|
:FDG
|
|||
|
:L =EINH
|
|||
|
:XG
|
|||
|
:T =H-ID
|
|||
|
M001 :
|
|||
|
:A =IMP
|
|||
|
:= =H-IM
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 4
|
|||
|
:A =STRT
|
|||
|
:A =IMP
|
|||
|
:AN -T9
|
|||
|
:L KT 010.2
|
|||
|
:SF -T9
|
|||
|
:
|
|||
|
:O -T9
|
|||
|
:ON =STRT
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =H-ID
|
|||
|
:L KG +6000000+01
|
|||
|
:XG
|
|||
|
:T =ISTD
|
|||
|
:
|
|||
|
:L KG +0000000+00
|
|||
|
:T =H-ID
|
|||
|
:
|
|||
|
FB 7 -FB 7 C:ZONE10ST.S5D LEN=108
|
|||
|
Page 3
|
|||
|
M001 :BE
|
|||
|
|
|||
|
T 9 = T9
|
|||
|
|
|||
|
FB 8 -FB 8 COUNT PULSE C:ZONE10ST.S5D LEN=80
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
FB 8 - IMPULSZAEHLUNG SPEICHERND SE/SA STAND: 21.06.00
|
|||
|
===============================================================================
|
|||
|
***** CPU : 948 *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : 21.06.00 R.GREMMINGER
|
|||
|
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG :
|
|||
|
|
|||
|
NR. DATUM AENDERUNG BEARBEITER
|
|||
|
-------------------------------------------------------------------------------
|
|||
|
01
|
|||
|
===============================================================================
|
|||
|
SYMBOLIKDATEI : KEINE
|
|||
|
---------------
|
|||
|
|
|||
|
BAUSTEINPARAMETER :
|
|||
|
-------------------
|
|||
|
#STRT : STARTBIT FUER ZAEHLER
|
|||
|
#AKTI : COUNTER LAEUFT
|
|||
|
#AUSG : COUNTER ABGELAUFEN
|
|||
|
#SOLL : SOLLWERT
|
|||
|
#IST : ISTWERT
|
|||
|
#IMP : IMPULSSIGNAL
|
|||
|
#H-IM : HILFSMERKER IMPULSSIGNAL (FLANKENAUSWERTUNG)
|
|||
|
#DIV : DIVISOR (GEZAELTE IMPULSE DIVIDIERT DURCH #DIV ERGIEBT DEN ISTWERT)
|
|||
|
|
|||
|
LOKALE VARIABLEN :
|
|||
|
------------------
|
|||
|
KEINE VERWENDET
|
|||
|
|
|||
|
Name :COUNTER
|
|||
|
Decl :STRT I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :RSET I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :AKTI I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :AUSG I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :SOLL I/Q/D/B/T/C: I BI/BY/W/D: D
|
|||
|
Decl :IST I/Q/D/B/T/C: Q BI/BY/W/D: D
|
|||
|
Decl :IMP I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :H-IM I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :EINH I/Q/D/B/T/C: I BI/BY/W/D: D
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2 COUNTER RESET
|
|||
|
:AN =RSET Bei Ansteuerung des Reset
|
|||
|
:JC =M001 Einganges wird der Counterausgan
|
|||
|
:RB =AUSG und das Counter Aktivsignal
|
|||
|
:RB =AKTI zurueckgesetzt.
|
|||
|
:
|
|||
|
:L KG +0000000+00 Die bereits gezaelten Impulse
|
|||
|
:T =IST werden zurueckgesetzt.
|
|||
|
:
|
|||
|
:BEU Der Baustein wird nicht mehr
|
|||
|
: weiter bearbeitet.
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 3 Zaehlen
|
|||
|
|
|||
|
FB 8 -FB 8 COUNT PULSE C:ZONE10ST.S5D LEN=80
|
|||
|
Page 2
|
|||
|
|
|||
|
Zaehlen :
|
|||
|
_____________
|
|||
|
STRT : __! !____
|
|||
|
________
|
|||
|
AKTI : __! !________
|
|||
|
____
|
|||
|
AUSG : ___________! !____
|
|||
|
|
|||
|
|
|||
|
SOLLWERT = ISTWERT
|
|||
|
|
|||
|
|
|||
|
:L =SOLL Sollwert ist groesser als
|
|||
|
:L =IST Istwert und
|
|||
|
:>G
|
|||
|
:A =STRT Startsignal steht an, dann
|
|||
|
:= =AKTI signalisiere 'Counter ist aktiv'
|
|||
|
:
|
|||
|
:A =STRT Ist der Sollwert erreicht & Star
|
|||
|
:AN =AKTI steht noch an, dann wird Ausgang
|
|||
|
:= =AUSG freigegeben.
|
|||
|
:
|
|||
|
:ON =AKTI Wenn der Counter aktiv ist und
|
|||
|
:ON =IMP ein ext. Impuls ansteht,
|
|||
|
:O =H-IM (Auswertung Flanke)
|
|||
|
:JC =M001 dann wird
|
|||
|
:L =IST die Istwert um
|
|||
|
:L =EINH
|
|||
|
::G
|
|||
|
:GFD
|
|||
|
:L KF +1 eine Einheit
|
|||
|
:+F erhoeht.
|
|||
|
:FDG
|
|||
|
:L =EINH
|
|||
|
:XG
|
|||
|
:T =IST
|
|||
|
M001 :
|
|||
|
:A =IMP Auswertung Flanke
|
|||
|
:= =H-IM
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 9 -FB 9 TIME MEASURING C:ZONE10ST.S5D LEN=107
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
FB 9 - TIMERNACHBILDUNG SPEICHERND SE/SA STAND: 07.10.98
|
|||
|
Vorlage: FB 108 - TIMERNACHBILDUNG SE/SA STAND: 22.10.97
|
|||
|
===============================================================================
|
|||
|
***** CPU : ALLE *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : 18.03.93 K.WEBER
|
|||
|
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG :
|
|||
|
|
|||
|
NR. DATUM AENDERUNG BEARBEITER
|
|||
|
-------------------------------------------------------------------------------
|
|||
|
01 22.10.97 N4 (1) UR
|
|||
|
02 07.10.98 N3,N4 (2) GRR
|
|||
|
===============================================================================
|
|||
|
SYMBOLIKDATEI : KEINE
|
|||
|
---------------
|
|||
|
|
|||
|
BAUSTEINPARAMETER :
|
|||
|
-------------------
|
|||
|
#STRT : STARTBIT FUER TIMER
|
|||
|
#AKTI : ZEIT LAEUFT (SIEHE EIN-/AUSSCHALTVERZOEGERUNG)
|
|||
|
#AUSG : TIMERAUSGANG
|
|||
|
#TTYP : SE = EINSCHALTVERZ. SA = AUSSCHALTVERZ.
|
|||
|
#SOLL : SOLLZEIT
|
|||
|
#IST : ISTZEIT
|
|||
|
#IMP : IMPULS DER ZEITBASIS (IMPULS = 1 ZYKLUS LANG)
|
|||
|
|
|||
|
|
|||
|
LOKALE VARIABLEN :
|
|||
|
------------------
|
|||
|
KEINE VERWENDET
|
|||
|
|
|||
|
Name :TIMER
|
|||
|
Decl :STRT I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :RSET I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :AKTI I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :AUSG I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :TTYP I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KS
|
|||
|
Decl :SOLL I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :IST I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :IMP I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2
|
|||
|
:AN =RSET
|
|||
|
:JC =M001
|
|||
|
:RB =AUSG
|
|||
|
:RB =AKTI
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T =IST
|
|||
|
:
|
|||
|
:BEU
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 3
|
|||
|
FB 9 -FB 9 TIME MEASURING C:ZONE10ST.S5D LEN=107
|
|||
|
Page 2
|
|||
|
|
|||
|
|
|||
|
Einschaltverzoegerung :
|
|||
|
__________
|
|||
|
STRT : __! !__
|
|||
|
____
|
|||
|
AKTI : __! !________
|
|||
|
_____
|
|||
|
AUSG : _______! !__
|
|||
|
|
|||
|
|
|||
|
:LW =TTYP
|
|||
|
:L KS SE
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:L =SOLL
|
|||
|
:L =IST
|
|||
|
:>F
|
|||
|
:A =STRT
|
|||
|
:= =AKTI
|
|||
|
:
|
|||
|
:A =STRT
|
|||
|
:AN =AKTI
|
|||
|
:= =AUSG
|
|||
|
:
|
|||
|
:
|
|||
|
:
|
|||
|
:
|
|||
|
:
|
|||
|
:
|
|||
|
:
|
|||
|
:ON =STRT
|
|||
|
:ON =IMP
|
|||
|
:JC =M001
|
|||
|
:L =IST
|
|||
|
:L KF +1
|
|||
|
:+F
|
|||
|
:T =IST
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 4
|
|||
|
|
|||
|
22.10.97 UR - (1) IST-DATENWORT LOESCHEN WENN START NICHT MEHR ANSTEHT
|
|||
|
07.10.98 GRR- (2) KEIN LOESCHEN
|
|||
|
|
|||
|
Ausschaltverzoegerung :
|
|||
|
___________
|
|||
|
STRT : _! !_____
|
|||
|
___
|
|||
|
AKTI : _____________! !_
|
|||
|
_______________
|
|||
|
AUSG : _! !_
|
|||
|
|
|||
|
|
|||
|
:LW =TTYP
|
|||
|
:L KS SA
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:L =SOLL
|
|||
|
:L =IST
|
|||
|
:>F
|
|||
|
:A =AUSG
|
|||
|
:AN =STRT
|
|||
|
FB 9 -FB 9 TIME MEASURING C:ZONE10ST.S5D LEN=107
|
|||
|
Page 3
|
|||
|
:= =AKTI
|
|||
|
:
|
|||
|
:O =STRT
|
|||
|
:O =AKTI
|
|||
|
:= =AUSG
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:ON =AUSG
|
|||
|
:
|
|||
|
:JC =M002
|
|||
|
:ON =STRT
|
|||
|
:ON =IMP
|
|||
|
:JC =M001
|
|||
|
:L =IST
|
|||
|
:L KF +1
|
|||
|
:+F
|
|||
|
M002 :T =IST
|
|||
|
M001 :BE
|
|||
|
|
|||
|
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
******************************************************************************
|
|||
|
|
|||
|
DESCRICTION :
|
|||
|
|
|||
|
This block handles the dosing from the ingredient hoppers to the scale HO500
|
|||
|
and the discharge to the diosna-mixer.
|
|||
|
|
|||
|
|
|||
|
|
|||
|
******************************************************************************
|
|||
|
|
|||
|
|
|||
|
PARAMETER :
|
|||
|
|
|||
|
|
|||
|
LINR : line number
|
|||
|
WANR : scale number
|
|||
|
WZNR : scale count number ( to calculate the data blocks )
|
|||
|
T1 : Timer 1 ( heel time vacuumpump )
|
|||
|
T2 : Timer 2 ( time until conveying pressure built up )
|
|||
|
T3 : Timer 3 ( cycle purged air filter )
|
|||
|
T4 : Timer 4 ( cycle rapper filter )
|
|||
|
T5 : Timer 5 ( cycle vibration motor )
|
|||
|
T6 : Timer 6 ( cycle compressed air )
|
|||
|
T7 : Timer 7 ( delay time multiport valve )
|
|||
|
T8 : Timer 8 ( TTOL FB92 )
|
|||
|
T9 : Timer 9 ( TFIN FB92 )
|
|||
|
T10 : Timer 10 ( )
|
|||
|
AF/J : lifting funct. J/N ( scale discharge with lifting function is
|
|||
|
selected , if this parameter is set to J )
|
|||
|
PWDT : analog input pressure transmiter
|
|||
|
PWFU : analog output frequency converter
|
|||
|
CPSI : charge phase step index
|
|||
|
ECSI : end of charge step
|
|||
|
DPSI : discharge phase step index
|
|||
|
EDSI : end of discharge step
|
|||
|
EMPY : empty check ( MIN<x<MAX)
|
|||
|
|
|||
|
*******************************************************************************
|
|||
|
|
|||
|
INTERNAL USED FUNCTION BLOCKS:
|
|||
|
|
|||
|
FB 190 Scale module
|
|||
|
FB 91 Occupy silo
|
|||
|
FB 106 Transfer KF->KT
|
|||
|
FB 90 Check multiport valve
|
|||
|
FB 108 Timer imitation
|
|||
|
FB 250 Read analog value
|
|||
|
FB 6 Pressure transmiter
|
|||
|
FB 251 Write analog value
|
|||
|
FB 92 Control weighing
|
|||
|
FB 113 Clock generator
|
|||
|
|
|||
|
*******************************************************************************
|
|||
|
|
|||
|
|
|||
|
Name :WAAGE
|
|||
|
Decl :LINR I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :WANR I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :WZNR I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T1 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T2 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 2
|
|||
|
Decl :T3 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T4 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T5 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T6 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T7 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T8 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T9 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T10 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :AF/J I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KS
|
|||
|
Decl :PWDT I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :PWFU I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :CPSI I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :ECSI I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :DPSI I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :EDSI I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :EMPY I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2 calculate DB-addresses
|
|||
|
:LW =LINR line no.
|
|||
|
:SLW 3 multiplyed 10
|
|||
|
:LW =LINR
|
|||
|
:SLW 1
|
|||
|
:+F
|
|||
|
:T -MW 32 ADDR.LINE_DB = address line-DB
|
|||
|
:
|
|||
|
:LW =WANR line DB
|
|||
|
:+F + scale no.
|
|||
|
:T -MW 34 ADDR.SCALE_DB = address scale-DB
|
|||
|
:
|
|||
|
:LW =WZNR scale count no.
|
|||
|
:L KF +164 + 164
|
|||
|
:+F = address DB dosing addresses
|
|||
|
:T -MW 38 ADDR.DOS_ADR_DB
|
|||
|
:***
|
|||
|
|
|||
|
FW 32 = MW 32 ADDR.LINE_DB
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
FW 38 = MW 38 ADDR.DOS_ADR_DB
|
|||
|
|
|||
|
Segment 3 store scale count number
|
|||
|
:DO -MW 34 ADDR.SCALE_DB
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:
|
|||
|
:LW =WZNR
|
|||
|
:T DW 1 hand over scale count number
|
|||
|
:
|
|||
|
:L -MW 34 ADDR.SCALE_DB
|
|||
|
:T DW 4 hand over number working-DB
|
|||
|
:
|
|||
|
:L -MW 38 ADDR.DOS_ADR_DB
|
|||
|
:T DW 5
|
|||
|
:***
|
|||
|
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
FW 38 = MW 38 ADDR.DOS_ADR_DB
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 4 load status of weighing
|
|||
|
:L DW 6
|
|||
|
:T -MW 10 I-CONTROLBITs interface to scale module
|
|||
|
:L DW 7
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 3
|
|||
|
:T -MW 12 I-CONTROLBITs
|
|||
|
:L DW 52
|
|||
|
:T -MW 14 O-CONTROLBITs
|
|||
|
:L DW 53
|
|||
|
:T -MW 16 O-CONTROLBITs
|
|||
|
: --------------------------------
|
|||
|
:L DW 114 internal variable weighing
|
|||
|
:T -MW18 STATUS FLAGS
|
|||
|
: --------------------------------
|
|||
|
:L DW 115 outputs scale
|
|||
|
:T -MW24 IND. OUTPUTS SCALE
|
|||
|
:L DW 117
|
|||
|
:T -MW28 IND. OUTPUTS WAY
|
|||
|
: --------------------------------
|
|||
|
:L DR 119 signal display
|
|||
|
:T -MB90 SIGNAL DISPLAY
|
|||
|
:***
|
|||
|
|
|||
|
FW 10 = MW 10 I-CONTROLBITs plc scale EST 1
|
|||
|
FW 12 = MW 12 I-CONTROLBITs plc scale EST 2
|
|||
|
FW 14 = MW 14 O-CONTROLBITs plc scale AST 1
|
|||
|
FW 16 = MW 16 O-CONTROLBITs plc scale AST 2
|
|||
|
FW 18 = MW18 STATUS FLAGS SCALE STATUS
|
|||
|
FW 24 = MW24 IND. OUTPUTS SCALE
|
|||
|
FW 28 = MW28 IND. OUTPUTS WAY
|
|||
|
FY 90 = MB90 SIGNAL DISPLAY SCALE SIGNAL DISPLAY
|
|||
|
|
|||
|
Segment 5 MODE to scale module
|
|||
|
:A -M 0.3 1 SEC. IMPULSE
|
|||
|
:= -ME12.0 1-SEC-IMPULSE
|
|||
|
:
|
|||
|
:AN -M 4.0 GLOBAL AUTO-MODE
|
|||
|
:AN -M 4.1 GLOB. MANUAL-MODE
|
|||
|
:O -M 4.2 GLOB.SERVICE-MODE
|
|||
|
:= -ME12.1 PLC-MODE/PC-MODE
|
|||
|
:***
|
|||
|
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
F 12.0 = ME12.0 1-SEC-IMPULSE plc scale EST 2
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
F 4.2 = M 4.2 GLOB.SERVICE-MODE
|
|||
|
F 12.1 = ME12.1 PLC-MODE/PC-MODE plc scale EST 2 (1=PLC-MODE / 0=PC-MODE)
|
|||
|
|
|||
|
Segment 6 communication scale module
|
|||
|
:JU -FB190 SCALE CONTROL
|
|||
|
Name :WAAGE
|
|||
|
W-NR : DW 1
|
|||
|
EST1 : -MW 10 I-CONTROLBITs
|
|||
|
EST2 : -MW 12 I-CONTROLBITs
|
|||
|
AST1 : -MW 14 O-CONTROLBITs
|
|||
|
AST2 : -MW 16 O-CONTROLBITs
|
|||
|
ANDB : -MW 34 ADDR.SCALE_DB
|
|||
|
DBDX : KS DB
|
|||
|
:***
|
|||
|
|
|||
|
FW 10 = MW 10 I-CONTROLBITs plc scale EST 1
|
|||
|
FW 12 = MW 12 I-CONTROLBITs plc scale EST 2
|
|||
|
FW 14 = MW 14 O-CONTROLBITs plc scale AST 1
|
|||
|
FW 16 = MW 16 O-CONTROLBITs plc scale AST 2
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
|
|||
|
FB 190 = FB190 SCALE CONTROL plc scale
|
|||
|
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 4
|
|||
|
Segment 7 got silo data
|
|||
|
:A -MA16.2 LOAD SILO DATA
|
|||
|
:= -ME10.4 GOT SILO DATA
|
|||
|
:***
|
|||
|
|
|||
|
F 16.2 = MA16.2 LOAD SILO DATA plc scale AST 2
|
|||
|
F 10.4 = ME10.4 GOT SILO DATA plc scale EST 1
|
|||
|
|
|||
|
Segment 8 silo_no. ok
|
|||
|
:A(
|
|||
|
:L DW 50 01
|
|||
|
:L KF +0 01 silo_no. 1-5 ok
|
|||
|
:>F 01
|
|||
|
:) 01
|
|||
|
:A(
|
|||
|
:L DW 50 01
|
|||
|
:L KF +5 01
|
|||
|
:<=F 01
|
|||
|
:) 01
|
|||
|
:= -M 18.0 SILO_NR_OK
|
|||
|
:***
|
|||
|
|
|||
|
F 18.0 = M 18.0 SILO_NR_OK
|
|||
|
|
|||
|
Segment 9 reserve silo with actual scale
|
|||
|
:O -MA15.4 POS.COMPO.ACTIVE
|
|||
|
:O -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:= F 210.0
|
|||
|
:
|
|||
|
:JU -FB91 OCCUPY_SILO
|
|||
|
Name :SILO-BEL
|
|||
|
SINR : DW 50 silo number
|
|||
|
WADB : -MW 34 ADDR.SCALE_DB working DB
|
|||
|
DOSI : F 210.0
|
|||
|
BELG : -M 18.3 SILO_OCCUPIED_OK
|
|||
|
SIOK : -M 18.0 SILO_NR_OK
|
|||
|
OFFS : KF +10
|
|||
|
SIAW : -MW20 IND. OUTPUTS Silo
|
|||
|
SIEW : -MW22 IND. INPUTs Silo
|
|||
|
:***
|
|||
|
|
|||
|
F 15.4 = MA15.4 POS.COMPO.ACTIVE plc scale AST 1
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
F 18.3 = M 18.3 SILO_OCCUPIED_OK
|
|||
|
F 18.0 = M 18.0 SILO_NR_OK
|
|||
|
FW 20 = MW20 IND. OUTPUTS Silo
|
|||
|
FW 22 = MW22 IND. INPUTs Silo
|
|||
|
|
|||
|
FB 91 = FB91 OCCUPY_SILO
|
|||
|
|
|||
|
Segment 10 start vacuum pump
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2 convert heel time
|
|||
|
EING : DW 150
|
|||
|
AUSG : FW 202
|
|||
|
: --------------------------------
|
|||
|
:LW =T1
|
|||
|
:T FW 200
|
|||
|
:
|
|||
|
:O -MA15.4 POS.COMPO.ACTIVE
|
|||
|
:O -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:O -MA16.4 DISCHARGE
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 5
|
|||
|
:L FW 202 heel time vacuum pump
|
|||
|
:DO FW 200
|
|||
|
:SF -T0 IND.ADDRES.(DUMMY)
|
|||
|
:DO FW 200
|
|||
|
:A -T0 IND.ADDRES.(DUMMY)
|
|||
|
:= -MA24.0 VACUUMPUMP ON
|
|||
|
:***
|
|||
|
|
|||
|
F 15.4 = MA15.4 POS.COMPO.ACTIVE plc scale AST 1
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 16.4 = MA16.4 DISCHARGE plc scale AST 2
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
F 24.0 = MA24.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 11 unload valve
|
|||
|
:O -MA15.4 POS.COMPO.ACTIVE
|
|||
|
:O -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:A -MA24.0 VACUUMPUMP ON
|
|||
|
:A -ME26.0 VACUUMPUMP ON
|
|||
|
:A -ME27.5 OUTLETFL. CLOSED
|
|||
|
:O(
|
|||
|
:A -MA24.7 ANGLE VALVE DISC 01
|
|||
|
:A -MA24.0 VACUUMPUMP ON 01
|
|||
|
:A -ME26.0 VACUUMPUMP ON 01
|
|||
|
:) 01
|
|||
|
:= -MA24.2 UNLOAD VALVE CON
|
|||
|
:***
|
|||
|
|
|||
|
F 15.4 = MA15.4 POS.COMPO.ACTIVE plc scale AST 1
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 24.0 = MA24.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
F 26.0 = ME26.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
F 27.5 = ME27.5 OUTLETFL. CLOSED
|
|||
|
F 24.7 = MA24.7 ANGLE VALVE DISC
|
|||
|
F 24.2 = MA24.2 UNLOAD VALVE CON
|
|||
|
|
|||
|
Segment 12 conveying pressure built up
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 151
|
|||
|
AUSG : FW 202
|
|||
|
: --------------------------------
|
|||
|
:LW =T2
|
|||
|
:T FW 200
|
|||
|
:
|
|||
|
:A -MA24.2 UNLOAD VALVE CON
|
|||
|
:A -ME26.2 UNLOAD VALVE CON
|
|||
|
:AN -ME27.2 UNLOAD V. RUN TH
|
|||
|
:L FW 202 time until conveying pressure
|
|||
|
:DO FW 200 buit up
|
|||
|
:SD -T0 IND.ADDRES.(DUMMY)
|
|||
|
:DO FW 200
|
|||
|
:A -T0 IND.ADDRES.(DUMMY)
|
|||
|
:= -M 18.2 PRESSUR_BUILD_UP
|
|||
|
:***
|
|||
|
|
|||
|
F 24.2 = MA24.2 UNLOAD VALVE CON
|
|||
|
F 26.2 = ME26.2 UNLOAD VALVE CON
|
|||
|
F 27.2 = ME27.2 UNLOAD V. RUN TH
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
F 18.2 = M 18.2 PRESSUR_BUILD_UP
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 6
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 13 release dosing to scale module
|
|||
|
:A -MA15.4 POS.COMPO.ACTIVE
|
|||
|
:A -M 18.2 PRESSUR_BUILD_UP
|
|||
|
:A -M 18.0 SILO_NR_OK
|
|||
|
:A -MA20.1 DOSING UNIT ON
|
|||
|
:A -ME22.1 DOSING UNIT ON
|
|||
|
:= -ME11.0 DOSIN.REL.POSITV
|
|||
|
:
|
|||
|
:A -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:A -M 18.2 PRESSUR_BUILD_UP
|
|||
|
:A -M 18.0 SILO_NR_OK
|
|||
|
:= -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:***
|
|||
|
|
|||
|
F 15.4 = MA15.4 POS.COMPO.ACTIVE plc scale AST 1
|
|||
|
F 18.2 = M 18.2 PRESSUR_BUILD_UP
|
|||
|
F 18.0 = M 18.0 SILO_NR_OK
|
|||
|
F 20.1 = MA20.1 DOSING UNIT ON
|
|||
|
F 22.1 = ME22.1 DOSING UNIT ON
|
|||
|
F 11.0 = ME11.0 DOSIN.REL.POSITV plc scale EST 1
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 11.2 = ME11.2 DOS.REL.CNTR/MAN plc scale EST 1
|
|||
|
|
|||
|
Segment 14 dosing timeout scale
|
|||
|
:LW =WZNR
|
|||
|
:L KF +100
|
|||
|
:+F
|
|||
|
:T -MW188 ADDR_OBJECT_DB/DX
|
|||
|
:L KF +192
|
|||
|
:T -MW186 DW_ADDRESS
|
|||
|
:L KF +9
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB135 TEST DATABIT
|
|||
|
Name :D-BIT AB
|
|||
|
DB : -MW188 ADDR_OBJECT_DB/DX
|
|||
|
DW : -MW186 DW_ADDRESS
|
|||
|
BIT : -MW180 PARAMETER 1
|
|||
|
WERT : -M 19.7 FAULT DOSING TIM
|
|||
|
DBDX : KS DB
|
|||
|
:***
|
|||
|
|
|||
|
FW 188 = MW188 ADDR_OBJECT_DB/DX
|
|||
|
FW 186 = MW186 DW_ADDRESS
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 19.7 = M 19.7 FAULT DOSING TIM
|
|||
|
|
|||
|
FB 135 = FB135 TEST DATABIT
|
|||
|
|
|||
|
Segment 15 multipot valve ok
|
|||
|
:LW =T7 timer to check the multiport
|
|||
|
:T -MW180 PARAMETER 1 valve
|
|||
|
:
|
|||
|
:JU -FB90 CHK_MULTIPORT_VALV
|
|||
|
Name :CHECK-QV
|
|||
|
AWQV : -MW28 IND. OUTPUTS WAY
|
|||
|
EWQV : -MW30 IND. INPUTS WAY
|
|||
|
FILT : KM 00011111 00000000
|
|||
|
TUMS : -MW180 PARAMETER 1
|
|||
|
QVOK : -M 18.1 WAY_OK
|
|||
|
ANGE : -M 18.7 WAY_ACTIV
|
|||
|
:
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 7
|
|||
|
:O -MA15.5 POS.DOS. ACTIVE
|
|||
|
:O -MA15.7 CNTR.WEI.DOS.ACT
|
|||
|
:= F 200.0 rel. compo_v
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 28 = MW28 IND. OUTPUTS WAY
|
|||
|
FW 30 = MW30 IND. INPUTS WAY
|
|||
|
F 18.1 = M 18.1 WAY_OK
|
|||
|
F 18.7 = M 18.7 WAY_ACTIV
|
|||
|
F 15.5 = MA15.5 POS.DOS. ACTIVE plc scale AST 1
|
|||
|
F 15.7 = MA15.7 CNTR.WEI.DOS.ACT plc scale AST 1
|
|||
|
|
|||
|
FB 90 = FB90 CHK_MULTIPORT_VALV check multiport valve ok: way ok
|
|||
|
|
|||
|
Segment 16 open component valve
|
|||
|
:L DW 170
|
|||
|
:T FW 202
|
|||
|
:
|
|||
|
:L KF +3 set value close component valve
|
|||
|
:T -MW180 PARAMETER 1 delayed
|
|||
|
:
|
|||
|
:JU -FB108 TIMER IMITATION
|
|||
|
Name :TIMER
|
|||
|
STRT : F 200.0 rel. compo_v
|
|||
|
RSET : -M 0.2 CONSTANT 0
|
|||
|
AKTI : F 202.2
|
|||
|
AUSG : F 202.3 compo_v open
|
|||
|
TTYP : KS SA
|
|||
|
SOLL : -MW180 PARAMETER 1
|
|||
|
IST : DW 171
|
|||
|
IMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
:
|
|||
|
:L FW 202
|
|||
|
:T DW 170
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 0.2 = M 0.2 CONSTANT 0
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 108 = FB108 TIMER IMITATION e.g. for scale control WK al
|
|||
|
|
|||
|
Segment 17 open component valve 1
|
|||
|
:A(
|
|||
|
:L DW 50 01 actual silo no.
|
|||
|
:L KF +1 01
|
|||
|
:!=F 01
|
|||
|
:) 01
|
|||
|
:A F 202.3 compo_v open
|
|||
|
:= F 200.0
|
|||
|
:
|
|||
|
:A -ME27.7 SECUNDARY FIL.OK
|
|||
|
:A F 200.0
|
|||
|
:S -MA28.0 COMPONENT VAL 1
|
|||
|
:
|
|||
|
:AN F 200.0
|
|||
|
:R -MA28.0 COMPONENT VAL 1
|
|||
|
:***
|
|||
|
|
|||
|
F 27.7 = ME27.7 SECUNDARY FIL.OK
|
|||
|
F 28.0 = MA28.0 COMPONENT VAL 1
|
|||
|
|
|||
|
Segment 18 open component valve 2
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 8
|
|||
|
:A(
|
|||
|
:L DW 50 01
|
|||
|
:L KF +2 01
|
|||
|
:!=F 01
|
|||
|
:) 01
|
|||
|
:A F 202.3 compo_v open
|
|||
|
:= F 200.0
|
|||
|
:
|
|||
|
:A -ME27.7 SECUNDARY FIL.OK
|
|||
|
:A F 200.0
|
|||
|
:S -MA28.1 COMPONENT VAL 2
|
|||
|
:
|
|||
|
:AN F 200.0
|
|||
|
:R -MA28.1 COMPONENT VAL 2
|
|||
|
:***
|
|||
|
|
|||
|
F 27.7 = ME27.7 SECUNDARY FIL.OK
|
|||
|
F 28.1 = MA28.1 COMPONENT VAL 2
|
|||
|
|
|||
|
Segment 19 open component valve 3
|
|||
|
:A(
|
|||
|
:L DW 50 01 actual silo no.
|
|||
|
:L KF +3 01
|
|||
|
:!=F 01
|
|||
|
:) 01
|
|||
|
:A F 202.3 compo_v open
|
|||
|
:= F 200.0
|
|||
|
:
|
|||
|
:A -ME27.7 SECUNDARY FIL.OK
|
|||
|
:A F 200.0
|
|||
|
:S -MA28.2 COMPONENT VAL 3
|
|||
|
:
|
|||
|
:AN F 200.0
|
|||
|
:R -MA28.2 COMPONENT VAL 3
|
|||
|
:***
|
|||
|
|
|||
|
F 27.7 = ME27.7 SECUNDARY FIL.OK
|
|||
|
F 28.2 = MA28.2 COMPONENT VAL 3
|
|||
|
|
|||
|
Segment 20 open component valve 4
|
|||
|
:A(
|
|||
|
:L DW 50 01
|
|||
|
:L KF +4 01
|
|||
|
:!=F 01
|
|||
|
:) 01
|
|||
|
:A F 202.3 compo_v open
|
|||
|
:= F 200.0
|
|||
|
:
|
|||
|
:A -ME27.7 SECUNDARY FIL.OK
|
|||
|
:A F 200.0
|
|||
|
:S -MA28.3 COMPONENT VAL 4
|
|||
|
:
|
|||
|
:AN F 200.0
|
|||
|
:R -MA28.3 COMPONENT VAL 4
|
|||
|
:***
|
|||
|
|
|||
|
F 27.7 = ME27.7 SECUNDARY FIL.OK
|
|||
|
F 28.3 = MA28.3 COMPONENT VAL 4
|
|||
|
|
|||
|
Segment 21 open component valve 5
|
|||
|
:A(
|
|||
|
:L DW 50 01 actual silo no.
|
|||
|
:L KF +5 01
|
|||
|
:!=F 01
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 9
|
|||
|
:) 01
|
|||
|
:A F 202.3 compo_v open
|
|||
|
:= F 200.0
|
|||
|
:
|
|||
|
:A -ME27.7 SECUNDARY FIL.OK
|
|||
|
:A F 200.0
|
|||
|
:S -MA28.4 COMPONENT VAL 5
|
|||
|
:
|
|||
|
:AN F 200.0
|
|||
|
:R -MA28.4 COMPONENT VAL 5
|
|||
|
:***
|
|||
|
|
|||
|
F 27.7 = ME27.7 SECUNDARY FIL.OK
|
|||
|
F 28.4 = MA28.4 COMPONENT VAL 5
|
|||
|
|
|||
|
Segment 22 close fresh air valve
|
|||
|
:O -MA15.7 CNTR.WEI.DOS.ACT
|
|||
|
:O -MA15.5 POS.DOS. ACTIVE
|
|||
|
:A -M 18.1 WAY_OK
|
|||
|
:A -M 18.7 WAY_ACTIV
|
|||
|
:AN -ME30.7 FAULT COMP. VAL.
|
|||
|
:= -MA24.4 FRESH AIR VAL CL
|
|||
|
:***
|
|||
|
|
|||
|
F 15.7 = MA15.7 CNTR.WEI.DOS.ACT plc scale AST 1
|
|||
|
F 15.5 = MA15.5 POS.DOS. ACTIVE plc scale AST 1
|
|||
|
F 18.1 = M 18.1 WAY_OK
|
|||
|
F 18.7 = M 18.7 WAY_ACTIV
|
|||
|
F 30.7 = ME30.7 FAULT COMP. VAL.
|
|||
|
F 24.4 = MA24.4 FRESH AIR VAL CL
|
|||
|
|
|||
|
Segment 23 read pressure
|
|||
|
:L KF +0
|
|||
|
:T FY 180 0 = P-address
|
|||
|
:LW =PWDT
|
|||
|
:T FY 181
|
|||
|
:
|
|||
|
:JU -FB118 PRESSURE TRANSMIT
|
|||
|
Name :DRUCKAUF
|
|||
|
BGRN : -MW180 PARAMETER 1
|
|||
|
OG : DW 123
|
|||
|
UG : DW 122
|
|||
|
AUSG : DW 124
|
|||
|
FEHL : F 200.0
|
|||
|
AKTV : -ME31.4 VACUUM ACTIV relative convey. pressure
|
|||
|
TIMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
S5S7 : KS S5
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 31.4 = ME31.4 VACUUM ACTIV
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 118 = FB118 PRESSURE TRANSMIT hkt as
|
|||
|
|
|||
|
Segment 24 pressure high
|
|||
|
:L DW 124 actual pressure
|
|||
|
:L DW 125 min pressure
|
|||
|
:>F
|
|||
|
:R -M 18.4 PRESSURE_HIGH
|
|||
|
:
|
|||
|
:L DW 124 actual pressure
|
|||
|
:L DW 126 max pressure
|
|||
|
:<F
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 10
|
|||
|
:O F 200.0
|
|||
|
:S -M 18.4 PRESSURE_HIGH
|
|||
|
:***
|
|||
|
|
|||
|
F 18.4 = M 18.4 PRESSURE_HIGH
|
|||
|
|
|||
|
Segment 25 delay time fault convey.pressure
|
|||
|
:L KF +10
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
Segment 26 output fault conveying pressure
|
|||
|
:L DW 170
|
|||
|
:T FW 202
|
|||
|
:
|
|||
|
:JU -FB108 TIMER IMITATION
|
|||
|
Name :TIMER
|
|||
|
STRT : -M 18.4 PRESSURE_HIGH
|
|||
|
RSET : -M 0.2 CONSTANT 0
|
|||
|
AKTI : F 202.0
|
|||
|
AUSG : -M 18.6 PRESSURE_FAULT
|
|||
|
TTYP : KS SE
|
|||
|
SOLL : -MW180 PARAMETER 1
|
|||
|
IST : DW 172
|
|||
|
IMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
:
|
|||
|
:L FW 202
|
|||
|
:T DW 170
|
|||
|
:***
|
|||
|
|
|||
|
F 18.4 = M 18.4 PRESSURE_HIGH
|
|||
|
F 0.2 = M 0.2 CONSTANT 0
|
|||
|
F 18.6 = M 18.6 PRESSURE_FAULT
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 108 = FB108 TIMER IMITATION e.g. for scale control WK al
|
|||
|
|
|||
|
Segment 27 release dosing silo
|
|||
|
:A -MA24.4 FRESH AIR VAL CL
|
|||
|
:A -ME26.4 FRESH AIR VAL CL
|
|||
|
:AN -ME27.4 FRESH AIR VAL OP
|
|||
|
:AN -M 18.4 PRESSURE_HIGH
|
|||
|
:= -M 18.5 DOS_REL_SILO
|
|||
|
:
|
|||
|
:A -MA20.2 FREQ.CONV. REL.
|
|||
|
:= -MA29.6 FREQ.CONV. SILO
|
|||
|
:L DW 55
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
M001 :T DW 146
|
|||
|
:***
|
|||
|
|
|||
|
F 24.4 = MA24.4 FRESH AIR VAL CL
|
|||
|
F 26.4 = ME26.4 FRESH AIR VAL CL
|
|||
|
F 27.4 = ME27.4 FRESH AIR VAL OP
|
|||
|
F 18.4 = M 18.4 PRESSURE_HIGH
|
|||
|
F 18.5 = M 18.5 DOS_REL_SILO
|
|||
|
F 20.2 = MA20.2 FREQ.CONV. REL. *** not used
|
|||
|
F 29.6 = MA29.6 FREQ.CONV. SILO
|
|||
|
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 11
|
|||
|
Segment 28 set value freq.conv.
|
|||
|
:LW =PWFU
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB251 WRIT ANALOG VALUE
|
|||
|
Name :AN-AUS
|
|||
|
APW : -MW180 PARAMETER 1
|
|||
|
OG : KG +1000000+04
|
|||
|
UG : KG +0000000+00
|
|||
|
AMAX : KF +1024
|
|||
|
AMIN : KF +0
|
|||
|
WERG : FD 192
|
|||
|
WERT : DW 146
|
|||
|
G/F : KS F
|
|||
|
IN : KS IN
|
|||
|
FORM : KS ..
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
FB 251 = FB251 WRIT ANALOG VALUE
|
|||
|
|
|||
|
Segment 29 release weight simulation
|
|||
|
:A -M 18.5 DOS_REL_SILO
|
|||
|
:A -MA21.4 >DOS_RUNNING SIL
|
|||
|
:= -ME11.4 DOS.UNIT RUN.POS
|
|||
|
:***
|
|||
|
|
|||
|
F 18.5 = M 18.5 DOS_REL_SILO
|
|||
|
F 21.4 = MA21.4 >DOS_RUNNING SIL
|
|||
|
F 11.4 = ME11.4 DOS.UNIT RUN.POS plc scale EST 1
|
|||
|
|
|||
|
Segment 30 check tolerance
|
|||
|
:LW =T8
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:LW =T9
|
|||
|
:T -MW182 PARAMETER 2
|
|||
|
:
|
|||
|
:JU -FB92 CONTROL_WEIGHING
|
|||
|
Name :CTR-WEIG
|
|||
|
WZNR : DW 1
|
|||
|
TOLE : DD 110
|
|||
|
TTOL : -MW180 PARAMETER 1
|
|||
|
EOCW : -M 19.2 CTRL-WEI IN TOLE
|
|||
|
TFIN : -MW182 PARAMETER 2
|
|||
|
CTRF : -M 19.1 CONTROL FINE
|
|||
|
DOSI : -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
DFIN : -ME31.3 REL CTRL-FINE
|
|||
|
:
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 19.2 = M 19.2 CTRL-WEI IN TOLE
|
|||
|
F 19.1 = M 19.1 CONTROL FINE
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 31.3 = ME31.3 REL CTRL-FINE
|
|||
|
|
|||
|
FB 92 = FB92 CONTROL_WEIGHING
|
|||
|
|
|||
|
Segment 31 receipt control weighing
|
|||
|
:A -MA21.5 >SILO EMPTY
|
|||
|
:A -M 19.2 CTRL-WEI IN TOLE
|
|||
|
:O
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 12
|
|||
|
:A -MA15.4 POS.COMPO.ACTIVE
|
|||
|
:A -ME13.5 REL.FOR REGISTR.
|
|||
|
:= =ECSI
|
|||
|
:
|
|||
|
:A =ECSI
|
|||
|
:A(
|
|||
|
:L =CPSI 01
|
|||
|
:L KF +90 01 Step 90: stop charge
|
|||
|
:>=F 01
|
|||
|
:) 01
|
|||
|
:A -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:S -ME10.2 RECPT.CNTR.WEIGH
|
|||
|
:
|
|||
|
:AN -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:R -ME10.2 RECPT.CNTR.WEIGH
|
|||
|
:***
|
|||
|
|
|||
|
F 21.5 = MA21.5 >SILO EMPTY
|
|||
|
F 19.2 = M 19.2 CTRL-WEI IN TOLE
|
|||
|
F 15.4 = MA15.4 POS.COMPO.ACTIVE plc scale AST 1
|
|||
|
F 13.5 = ME13.5 REL.FOR REGISTR. plc scale EST 2
|
|||
|
F 11.2 = ME11.2 DOS.REL.CNTR/MAN plc scale EST 1
|
|||
|
F 10.2 = ME10.2 RECPT.CNTR.WEIGH plc scale EST 1
|
|||
|
|
|||
|
Segment 32 rel. cleaning filter
|
|||
|
:O(
|
|||
|
:A -MA15.5 POS.DOS. ACTIVE 01
|
|||
|
:A -MA15.0 POSITIVE COURSE 01
|
|||
|
:) 01
|
|||
|
:O -MA15.7 CNTR.WEI.DOS.ACT
|
|||
|
:A -ME11.4 DOS.UNIT RUN.POS
|
|||
|
:= F 201.0
|
|||
|
:
|
|||
|
:A -MA24.5 OUTLETFLAP OPEN
|
|||
|
:A -ME26.5 OUTLETFLAP OPEN
|
|||
|
:AN -ME27.5 OUTLETFL. CLOSED
|
|||
|
:AN -MA17.3 STRT.DISCH.HELP
|
|||
|
:AN -MA16.6 FIN.DISCHARG.FIN
|
|||
|
:AN -MA16.7 INT.DISCHARG.FIN
|
|||
|
:= F 201.1
|
|||
|
:
|
|||
|
:O F 201.0
|
|||
|
:O F 201.1
|
|||
|
:= F 200.0
|
|||
|
:***
|
|||
|
|
|||
|
F 15.5 = MA15.5 POS.DOS. ACTIVE plc scale AST 1
|
|||
|
F 15.0 = MA15.0 POSITIVE COURSE plc scale AST 1
|
|||
|
F 15.7 = MA15.7 CNTR.WEI.DOS.ACT plc scale AST 1
|
|||
|
F 11.4 = ME11.4 DOS.UNIT RUN.POS plc scale EST 1
|
|||
|
F 24.5 = MA24.5 OUTLETFLAP OPEN
|
|||
|
F 26.5 = ME26.5 OUTLETFLAP OPEN
|
|||
|
F 27.5 = ME27.5 OUTLETFL. CLOSED
|
|||
|
F 17.3 = MA17.3 STRT.DISCH.HELP plc scale AST 2
|
|||
|
F 16.6 = MA16.6 FIN.DISCHARG.FIN plc scale AST 2
|
|||
|
F 16.7 = MA16.7 INT.DISCHARG.FIN plc scale AST 2
|
|||
|
|
|||
|
Segment 33 timer no. cycle filter
|
|||
|
:L DW 152
|
|||
|
:T -MW182 PARAMETER 2
|
|||
|
:
|
|||
|
:L DW 153
|
|||
|
:T -MW184 PARAMETER 3
|
|||
|
:
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 13
|
|||
|
:A F 201.0
|
|||
|
:JC =M001 --------------------------------
|
|||
|
:
|
|||
|
:L DW 156
|
|||
|
:T -MW182 PARAMETER 2
|
|||
|
:
|
|||
|
:L DW 157
|
|||
|
:T -MW184 PARAMETER 3
|
|||
|
M001 :***
|
|||
|
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
Segment 34 time cycle filter cleaning
|
|||
|
:LW =T3
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +1 convert impulse time
|
|||
|
EING : -MW182 PARAMETER 2
|
|||
|
AUSG : FW 202
|
|||
|
: --------------------------------
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2 convert break time
|
|||
|
EING : -MW184 PARAMETER 3
|
|||
|
AUSG : FW 204
|
|||
|
: --------------------------------
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 35 cycle purged air filter cleaning
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : F 200.0
|
|||
|
T : -T0 IND.ADDRES.(DUMMY)
|
|||
|
DWIM : FW 202
|
|||
|
DWPA : FW 204
|
|||
|
AUSG : -M 19.0 FILTER ACTIV
|
|||
|
POS : -M 0.1 CONSTANT 1
|
|||
|
DBT : -DB11 HO500 SCALE1:HO50X
|
|||
|
RM : -M 19.0 FILTER ACTIV
|
|||
|
T-IN : -MW180 PARAMETER 1
|
|||
|
IN : KS IN
|
|||
|
SOLL : KF +2
|
|||
|
IST : DW 147
|
|||
|
FERT : F 200.1
|
|||
|
BITL : DW 148
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB11 HO500 SCALE1:HO50X
|
|||
|
:***
|
|||
|
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
F 19.0 = M 19.0 FILTER ACTIV
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
DB 11 = DB11 HO500 SCALE1:HO50X HO500 area 1 scale 1: ingredient weighin
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 14
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 36 filter 1+2 on
|
|||
|
:A -M 19.0 FILTER ACTIV
|
|||
|
:A D 148.0
|
|||
|
:= -MA25.2 FILTER 1 ON
|
|||
|
:
|
|||
|
:A -M 19.0 FILTER ACTIV
|
|||
|
:A D 148.1
|
|||
|
:= -MA25.3 FILTER 2 ON
|
|||
|
:***
|
|||
|
|
|||
|
F 19.0 = M 19.0 FILTER ACTIV
|
|||
|
F 25.2 = MA25.2 FILTER 1 ON
|
|||
|
F 25.3 = MA25.3 FILTER 2 ON
|
|||
|
|
|||
|
Segment 37 time cycle rapper filter
|
|||
|
:LW =T4
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +1 convert impulse time
|
|||
|
EING : DW 158
|
|||
|
AUSG : FW 202
|
|||
|
: --------------------------------
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2 convert break time
|
|||
|
EING : DW 159
|
|||
|
AUSG : FW 204
|
|||
|
: --------------------------------
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 38 cycle rapper filter cleaning
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : F 201.1
|
|||
|
T : -T0 IND.ADDRES.(DUMMY)
|
|||
|
DWIM : FW 202
|
|||
|
DWPA : FW 204
|
|||
|
AUSG : -MA25.1 RAPPER FILTER ON
|
|||
|
POS : -M 0.1 CONSTANT 1
|
|||
|
DBT : -DB11 HO500 SCALE1:HO50X
|
|||
|
RM : -MA25.1 RAPPER FILTER ON
|
|||
|
T-IN : -MW180 PARAMETER 1
|
|||
|
IN : KS IN
|
|||
|
SOLL : KF +2
|
|||
|
IST : DW 127
|
|||
|
FERT : F 200.1
|
|||
|
BITL : DW 128
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB11 HO500 SCALE1:HO50X
|
|||
|
:***
|
|||
|
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
F 25.1 = MA25.1 RAPPER FILTER ON
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 15
|
|||
|
DB 11 = DB11 HO500 SCALE1:HO50X HO500 area 1 scale 1: ingredient weighin
|
|||
|
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 39 rapper filter 1+2 on
|
|||
|
:A -MA25.1 RAPPER FILTER ON
|
|||
|
:A D 128.0
|
|||
|
:= -MA25.5 RAPPER 1 ON
|
|||
|
:
|
|||
|
:A -MA25.1 RAPPER FILTER ON
|
|||
|
:A D 128.1
|
|||
|
:= -MA25.6 RAPPER 2 ON
|
|||
|
:***
|
|||
|
|
|||
|
F 25.1 = MA25.1 RAPPER FILTER ON
|
|||
|
F 25.5 = MA25.5 RAPPER 1 ON
|
|||
|
F 25.6 = MA25.6 RAPPER 2 ON
|
|||
|
|
|||
|
Segment 40 ackn. register request
|
|||
|
:A -MA17.5 REGISTR.REQUEST
|
|||
|
:= -ME13.5 REL.FOR REGISTR.
|
|||
|
:***
|
|||
|
|
|||
|
F 17.5 = MA17.5 REGISTR.REQUEST plc scale AST 2
|
|||
|
F 13.5 = ME13.5 REL.FOR REGISTR. plc scale EST 2
|
|||
|
|
|||
|
Segment 41 max. empty level
|
|||
|
:L DD 106 max. empty weight
|
|||
|
:T FD 190
|
|||
|
:
|
|||
|
:L DW 1 scale number
|
|||
|
:L KF +100
|
|||
|
:+F
|
|||
|
:T FW 200
|
|||
|
:
|
|||
|
:DO FW 200
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:
|
|||
|
:L DD 38 scale empty level
|
|||
|
:L FD 190
|
|||
|
:>=G
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 38 scale empty level
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 42 load gross/ registrated weight
|
|||
|
:L DD 198 gross weight
|
|||
|
:T FD 190 gross weight scale
|
|||
|
:
|
|||
|
:L DD 195 registrated weight
|
|||
|
:T FD 200 registrated weight scale
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 43 empty check
|
|||
|
:DO -MW 34 ADDR.SCALE_DB
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:
|
|||
|
:L DD 106 max. empty weight
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 16
|
|||
|
:L FD 190
|
|||
|
:>=G
|
|||
|
:A(
|
|||
|
:L DD 108 01 min. empty weight
|
|||
|
:L FD 190 01
|
|||
|
:<=G 01
|
|||
|
:) 01
|
|||
|
:= =EMPY
|
|||
|
:***
|
|||
|
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 44 start weight / reg.weight fillin
|
|||
|
:O -MA17.0 TARNG/CALMNG ACT
|
|||
|
:O D 112.0 hf taring act
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 132 start weight filling
|
|||
|
M001 :
|
|||
|
:A -MA17.0 TARNG/CALMNG ACT
|
|||
|
:S D 112.0 hf taring act
|
|||
|
:
|
|||
|
:AN -ME13.5 REL.FOR REGISTR. *** NO EFFECT DURING TEST
|
|||
|
:JC =M002 ***
|
|||
|
: ***
|
|||
|
:L FD 190 ***
|
|||
|
:T DD 134 *** end weight filling
|
|||
|
M002 : ***
|
|||
|
:L FD 200
|
|||
|
:T DD 130 registrated weight filling
|
|||
|
: }}} TEST {{{
|
|||
|
:L DD 132 start weight filling
|
|||
|
:L DD 130 registrated weight filling
|
|||
|
:+G
|
|||
|
:T DD 134 end weight filling
|
|||
|
:***
|
|||
|
|
|||
|
F 17.0 = MA17.0 TARNG/CALMNG ACT plc scale AST 2
|
|||
|
F 13.5 = ME13.5 REL.FOR REGISTR. plc scale EST 2
|
|||
|
|
|||
|
Segment 45
|
|||
|
: from this network on starts
|
|||
|
: the discharging of the scale
|
|||
|
:
|
|||
|
:***
|
|||
|
|
|||
|
Segment 46 open outletflap
|
|||
|
:A -MA16.4 DISCHARGE
|
|||
|
:= -MA24.7 ANGLE VALVE DISC
|
|||
|
:
|
|||
|
:A -MA16.4 DISCHARGE
|
|||
|
:A -M 18.2 PRESSUR_BUILD_UP
|
|||
|
:= -ME10.0 RELEASE DISCHARG
|
|||
|
:
|
|||
|
:A -ME10.0 RELEASE DISCHARG
|
|||
|
:A -ME31.7 SCALE_DISCH REL.
|
|||
|
:= -MA24.5 OUTLETFLAP OPEN
|
|||
|
:
|
|||
|
:A -MA24.5 OUTLETFLAP OPEN
|
|||
|
:A -ME26.5 OUTLETFLAP OPEN
|
|||
|
:AN -ME27.5 OUTLETFL. CLOSED
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 17
|
|||
|
:= -MA29.7 SCALE_DISCH ON
|
|||
|
:***
|
|||
|
|
|||
|
F 16.4 = MA16.4 DISCHARGE plc scale AST 2
|
|||
|
F 24.7 = MA24.7 ANGLE VALVE DISC
|
|||
|
F 18.2 = M 18.2 PRESSUR_BUILD_UP
|
|||
|
F 10.0 = ME10.0 RELEASE DISCHARG plc scale EST 1
|
|||
|
F 31.7 = ME31.7 SCALE_DISCH REL.
|
|||
|
F 24.5 = MA24.5 OUTLETFLAP OPEN
|
|||
|
F 26.5 = ME26.5 OUTLETFLAP OPEN
|
|||
|
F 27.5 = ME27.5 OUTLETFL. CLOSED
|
|||
|
F 29.7 = MA29.7 SCALE_DISCH ON
|
|||
|
|
|||
|
Segment 47 timer compressed air
|
|||
|
:LW =T6
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +1 convert impulse time
|
|||
|
EING : DW 160
|
|||
|
AUSG : FW 202
|
|||
|
: --------------------------------
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2 convert break time
|
|||
|
EING : DW 161
|
|||
|
AUSG : FW 204
|
|||
|
: --------------------------------
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 48 cycle compressed air
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : -MA29.7 SCALE_DISCH ON
|
|||
|
T : -T0 IND.ADDRES.(DUMMY)
|
|||
|
DWIM : FW 202
|
|||
|
DWPA : FW 204
|
|||
|
AUSG : -MA25.0 COMPRES.AIR ON
|
|||
|
POS : -M 0.1 CONSTANT 1
|
|||
|
DBT : -DB11 HO500 SCALE1:HO50X
|
|||
|
RM : -MA25.0 COMPRES.AIR ON
|
|||
|
T-IN : -MW180 PARAMETER 1
|
|||
|
IN : KS IN
|
|||
|
SOLL : KF +0
|
|||
|
IST : FW 206
|
|||
|
FERT : F 200.1
|
|||
|
BITL : FW 208
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB11 HO500 SCALE1:HO50X
|
|||
|
:***
|
|||
|
|
|||
|
F 29.7 = MA29.7 SCALE_DISCH ON
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
F 25.0 = MA25.0 COMPRES.AIR ON
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
DB 11 = DB11 HO500 SCALE1:HO50X HO500 area 1 scale 1: ingredient weighin
|
|||
|
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 18
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 49 time vibration motor
|
|||
|
:LW =T5
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2 convert impulse time
|
|||
|
EING : DW 154
|
|||
|
AUSG : FW 202
|
|||
|
: --------------------------------
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2 convert break time
|
|||
|
EING : DW 155
|
|||
|
AUSG : FW 204
|
|||
|
: --------------------------------
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 50 cycle vibration motor
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : -MA29.7 SCALE_DISCH ON
|
|||
|
T : -T0 IND.ADDRES.(DUMMY)
|
|||
|
DWIM : FW 202
|
|||
|
DWPA : FW 204
|
|||
|
AUSG : -MA24.1 VIBRATOR ON
|
|||
|
POS : -M 0.1 CONSTANT 1
|
|||
|
DBT : -DB11 HO500 SCALE1:HO50X
|
|||
|
RM : -ME26.1 VIBRATOR ON
|
|||
|
T-IN : -MW180 PARAMETER 1
|
|||
|
IN : KS IN
|
|||
|
SOLL : KF +0
|
|||
|
IST : FW 206
|
|||
|
FERT : F 200.1
|
|||
|
BITL : FW 208
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB11 HO500 SCALE1:HO50X
|
|||
|
:***
|
|||
|
|
|||
|
F 29.7 = MA29.7 SCALE_DISCH ON
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
F 24.1 = MA24.1 VIBRATOR ON
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 26.1 = ME26.1 VIBRATOR ON
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
DB 11 = DB11 HO500 SCALE1:HO50X HO500 area 1 scale 1: ingredient weighin
|
|||
|
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 51 got weight value to scale module
|
|||
|
:A -MA16.6 FIN.DISCHARG.FIN
|
|||
|
:= =EDSI
|
|||
|
:
|
|||
|
:O( *(6)
|
|||
|
:L =DPSI 01
|
|||
|
:L KF +90 01 Step 90: stop discharge
|
|||
|
:>=F 01
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 19
|
|||
|
:) 01
|
|||
|
:ON -ME31.6 PLI_DISCHARG.RUN *(6)
|
|||
|
:A =EDSI
|
|||
|
:= -ME10.1 SCALE DISCHARGED
|
|||
|
:
|
|||
|
:A -MA16.3 TAKEOV.WEIGHT VA
|
|||
|
:= -ME10.5 GOT WEIGHT VALUE
|
|||
|
:
|
|||
|
:AN -ME10.1 SCALE DISCHARGED
|
|||
|
:JC =M001
|
|||
|
:L KF +0
|
|||
|
:T DW 50 delete silo no.
|
|||
|
:T DW 51 delete consumer no.
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 16.6 = MA16.6 FIN.DISCHARG.FIN plc scale AST 2
|
|||
|
F 31.6 = ME31.6 PLI_DISCHARG.RUN *(6)
|
|||
|
F 10.1 = ME10.1 SCALE DISCHARGED plc scale EST 1
|
|||
|
F 16.3 = MA16.3 TAKEOV.WEIGHT VA plc scale AST 2
|
|||
|
F 10.5 = ME10.5 GOT WEIGHT VALUE plc scale EST 1
|
|||
|
|
|||
|
Segment 52 start weight / end weight discha
|
|||
|
:ON -MA24.5 OUTLETFLAP OPEN
|
|||
|
:ON -MA16.5 FINAL DISCHARGE
|
|||
|
:JC =M001
|
|||
|
:A -M 19.4 GOT_DIS_STRT WEI
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 138 start weight discharge
|
|||
|
:A -M 0.1 CONSTANT 1
|
|||
|
:S -M 19.4 GOT_DIS_STRT WEI
|
|||
|
M001 :
|
|||
|
:AN -ME10.1 SCALE DISCHARGED
|
|||
|
:JC =M002
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 140 end weight discharge
|
|||
|
M002 :
|
|||
|
:A -ME10.5 GOT WEIGHT VALUE
|
|||
|
:R -M 19.4 GOT_DIS_STRT WEI
|
|||
|
:***
|
|||
|
|
|||
|
F 24.5 = MA24.5 OUTLETFLAP OPEN
|
|||
|
F 16.5 = MA16.5 FINAL DISCHARGE plc scale AST 2
|
|||
|
F 19.4 = M 19.4 GOT_DIS_STRT WEI
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 10.1 = ME10.1 SCALE DISCHARGED plc scale EST 1
|
|||
|
F 10.5 = ME10.5 GOT WEIGHT VALUE plc scale EST 1
|
|||
|
|
|||
|
Segment 53 discharged weight
|
|||
|
: ldd142 discharged weight
|
|||
|
:L DD 138 weight at start
|
|||
|
:L DD 140 weight at end
|
|||
|
:-G
|
|||
|
:T DD 136 prepare for block transfer
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 54 delete report charge
|
|||
|
:L =CPSI
|
|||
|
:L KF +40
|
|||
|
:>=F
|
|||
|
:JC =M001
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 20
|
|||
|
:
|
|||
|
:L KG +0000000+00 erase
|
|||
|
:T DD 130 registrated weight
|
|||
|
:T DD 132 start weight charge
|
|||
|
:T DD 134 end weight charge
|
|||
|
:
|
|||
|
:A -M 0.1 CONSTANT 1
|
|||
|
:R D 112.0 hf taring act
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
|
|||
|
Segment 55 delete report discharge
|
|||
|
:L =DPSI
|
|||
|
:L KF +40
|
|||
|
:>=F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KG +0000000+00 erase
|
|||
|
:T DD 136 discharged weight
|
|||
|
:T DD 138 start weight discharge
|
|||
|
:T DD 140 end weight discharge
|
|||
|
:T DD 142 Discharged weight
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 56 signal display
|
|||
|
:A -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:AN -M 19.1 CONTROL FINE
|
|||
|
:O -MA14.0 NEGATIVE COURSE
|
|||
|
:O -MA15.0 POSITIVE COURSE
|
|||
|
:= -M 90.0 COARSE_SPEED
|
|||
|
:
|
|||
|
:O -M 19.1 CONTROL FINE
|
|||
|
:O -MA14.1 NEGATIVE FINE
|
|||
|
:O -MA15.1 POSITIVE FINE
|
|||
|
:= -M 90.1 FINE_SPEED
|
|||
|
:
|
|||
|
:O -MA14.2 NEGATIVE EX-FINE
|
|||
|
:O -MA15.2 POSITIVE EX-FINE
|
|||
|
:= -M 90.2 EXTRAFINE_SPEED
|
|||
|
:
|
|||
|
:O -MA14.4 NEG.COMPO.ACTIVE
|
|||
|
:O -MA15.4 POS.COMPO.ACTIVE
|
|||
|
:O -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:S D 112.7 display registrated weight
|
|||
|
:A -MA16.4 DISCHARGE
|
|||
|
:R D 112.7 display registrated weight
|
|||
|
:***
|
|||
|
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 19.1 = M 19.1 CONTROL FINE
|
|||
|
F 14.0 = MA14.0 NEGATIVE COURSE plc scale AST 1
|
|||
|
F 15.0 = MA15.0 POSITIVE COURSE plc scale AST 1
|
|||
|
F 90.0 = M 90.0 COARSE_SPEED
|
|||
|
F 14.1 = MA14.1 NEGATIVE FINE plc scale AST 1
|
|||
|
F 15.1 = MA15.1 POSITIVE FINE plc scale AST 1
|
|||
|
F 90.1 = M 90.1 FINE_SPEED
|
|||
|
F 14.2 = MA14.2 NEGATIVE EX-FINE plc scale AST 1
|
|||
|
F 15.2 = MA15.2 POSITIVE EX-FINE plc scale AST 1
|
|||
|
F 90.2 = M 90.2 EXTRAFINE_SPEED
|
|||
|
F 14.4 = MA14.4 NEG.COMPO.ACTIVE plc scale AST 1
|
|||
|
F 15.4 = MA15.4 POS.COMPO.ACTIVE plc scale AST 1
|
|||
|
F 16.4 = MA16.4 DISCHARGE plc scale AST 2
|
|||
|
FB 11 -FB11 HO500 SCALE1:HO50X C:ZONE10ST.S5D LEN=914
|
|||
|
Page 21
|
|||
|
Segment 57 store status of weighing
|
|||
|
:L -MW 10 I-CONTROLBITs
|
|||
|
:T DW 6
|
|||
|
:L -MW 12 I-CONTROLBITs interface to scale module
|
|||
|
:T DW 7
|
|||
|
:L -MW 14 O-CONTROLBITs
|
|||
|
:T DW 52
|
|||
|
:L -MW 16 O-CONTROLBITs
|
|||
|
:T DW 53
|
|||
|
: --------------------------------
|
|||
|
:L -MW24 IND. OUTPUTS SCALE outputs / inputs
|
|||
|
:T DW 115
|
|||
|
:L -MW26 IND. INPUTS SCALE
|
|||
|
:T DW 116
|
|||
|
:L -MW28 IND. OUTPUTS WAY
|
|||
|
:T DW 117
|
|||
|
:L -MW30 IND. INPUTS WAY
|
|||
|
:T DW 118
|
|||
|
: --------------------------------
|
|||
|
:***
|
|||
|
|
|||
|
FW 10 = MW 10 I-CONTROLBITs plc scale EST 1
|
|||
|
FW 12 = MW 12 I-CONTROLBITs plc scale EST 2
|
|||
|
FW 14 = MW 14 O-CONTROLBITs plc scale AST 1
|
|||
|
FW 16 = MW 16 O-CONTROLBITs plc scale AST 2
|
|||
|
FW 24 = MW24 IND. OUTPUTS SCALE
|
|||
|
FW 26 = MW26 IND. INPUTS SCALE
|
|||
|
FW 28 = MW28 IND. OUTPUTS WAY
|
|||
|
FW 30 = MW30 IND. INPUTS WAY
|
|||
|
|
|||
|
Segment 58 store status of weighing
|
|||
|
:L -MW18 STATUS FLAGS internal variable weighing
|
|||
|
:T DW 114
|
|||
|
: --------------------------------
|
|||
|
:L -MB90 SIGNAL DISPLAY signal display
|
|||
|
:T DR 119
|
|||
|
:BE
|
|||
|
|
|||
|
FW 18 = MW18 STATUS FLAGS SCALE STATUS
|
|||
|
FY 90 = MB90 SIGNAL DISPLAY SCALE SIGNAL DISPLAY
|
|||
|
|
|||
|
FB 21 C:ZONE10ST.S5D LEN=326
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
******************************************************************************
|
|||
|
|
|||
|
DESCRIPTION :
|
|||
|
|
|||
|
This block handles the control weighing from dryer via cone mill container
|
|||
|
scale HO580.
|
|||
|
|
|||
|
|
|||
|
|
|||
|
******************************************************************************
|
|||
|
|
|||
|
PARAMETER :
|
|||
|
|
|||
|
LINR : line number
|
|||
|
WANR : scale number
|
|||
|
WZNR : scale count number ( to calculate to datablock )
|
|||
|
T1 : timer 1 ( TTOL FB92 )
|
|||
|
T2 : timer 2 ( TFIN FB92 )
|
|||
|
CPSI : charge phase step index
|
|||
|
ECSI : end of charge step
|
|||
|
DPSI : discharge phase step index
|
|||
|
EDSI : end of discharge step
|
|||
|
EMPY : empty check ( MIN<x<MAX )
|
|||
|
|
|||
|
*******************************************************************************
|
|||
|
|
|||
|
INTERNAL USED BLOCKS :
|
|||
|
|
|||
|
FB 190 Scale module
|
|||
|
FB 92 Control weighing
|
|||
|
|
|||
|
*******************************************************************************
|
|||
|
|
|||
|
Name :WAAGE
|
|||
|
Decl :LINR I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :WANR I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :WZNR I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T1 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T2 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :CPSI I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :ECSI I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :DPSI I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :EMPY I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2 calculate DB addresses
|
|||
|
:LW =LINR
|
|||
|
:SLW 3 line no.
|
|||
|
:LW =LINR * 10
|
|||
|
:SLW 1
|
|||
|
:+F
|
|||
|
:T -MW 32 ADDR.LINE_DB = address line-DB
|
|||
|
:
|
|||
|
:LW =WANR line-DB
|
|||
|
:+F + scale no.
|
|||
|
:T -MW 34 ADDR.SCALE_DB = address scale-DB
|
|||
|
:
|
|||
|
:LW =WZNR scale count no.
|
|||
|
:L KF +164 + 164
|
|||
|
:+F = address DB dosing addresses
|
|||
|
:T -MW 38 ADDR.DOS_ADR_DB
|
|||
|
FB 21 C:ZONE10ST.S5D LEN=326
|
|||
|
Page 2
|
|||
|
:***
|
|||
|
|
|||
|
FW 32 = MW 32 ADDR.LINE_DB
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
FW 38 = MW 38 ADDR.DOS_ADR_DB
|
|||
|
|
|||
|
Segment 3 store scale count number
|
|||
|
:DO -MW 34 ADDR.SCALE_DB
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:
|
|||
|
:LW =WZNR
|
|||
|
:T DW 1 hand over scale count no.
|
|||
|
:
|
|||
|
:L -MW 34 ADDR.SCALE_DB
|
|||
|
:T DW 4 hand over no. working-DB
|
|||
|
:
|
|||
|
:L -MW 38 ADDR.DOS_ADR_DB
|
|||
|
:T DW 5
|
|||
|
:***
|
|||
|
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
FW 38 = MW 38 ADDR.DOS_ADR_DB
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 4 read status of weighing
|
|||
|
:L DW 6
|
|||
|
:T -MW 10 I-CONTROLBITs interface to scale module
|
|||
|
:L DW 7
|
|||
|
:T -MW 12 I-CONTROLBITs
|
|||
|
:L DW 52
|
|||
|
:T -MW 14 O-CONTROLBITs
|
|||
|
:L DW 53
|
|||
|
:T -MW 16 O-CONTROLBITs
|
|||
|
: --------------------------------
|
|||
|
:L DW 114 internal variable scale
|
|||
|
:T -MW18 STATUS FLAGS
|
|||
|
: --------------------------------
|
|||
|
:L DW 115 outputs scale
|
|||
|
:T -MW24 IND. OUTPUTS SCALE
|
|||
|
:L DW 117
|
|||
|
:T -MW28 IND. OUTPUTS WAY
|
|||
|
: --------------------------------
|
|||
|
:***
|
|||
|
|
|||
|
FW 10 = MW 10 I-CONTROLBITs plc scale EST 1
|
|||
|
FW 12 = MW 12 I-CONTROLBITs plc scale EST 2
|
|||
|
FW 14 = MW 14 O-CONTROLBITs plc scale AST 1
|
|||
|
FW 16 = MW 16 O-CONTROLBITs plc scale AST 2
|
|||
|
FW 18 = MW18 STATUS FLAGS SCALE STATUS
|
|||
|
FW 24 = MW24 IND. OUTPUTS SCALE
|
|||
|
FW 28 = MW28 IND. OUTPUTS WAY
|
|||
|
|
|||
|
Segment 5 MODE to scale module
|
|||
|
:A -M 0.3 1 SEC. IMPULSE
|
|||
|
:= -ME12.0 1-SEC-IMPULSE
|
|||
|
:
|
|||
|
:AN -M 4.0 GLOBAL AUTO-MODE
|
|||
|
:AN -M 4.1 GLOB. MANUAL-MODE
|
|||
|
:O -M 4.2 GLOB.SERVICE-MODE
|
|||
|
:O F 99.7
|
|||
|
:= -ME12.1 PLC-MODE/PC-MODE
|
|||
|
:***
|
|||
|
|
|||
|
FB 21 C:ZONE10ST.S5D LEN=326
|
|||
|
Page 3
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
F 12.0 = ME12.0 1-SEC-IMPULSE plc scale EST 2
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
F 4.2 = M 4.2 GLOB.SERVICE-MODE
|
|||
|
F 12.1 = ME12.1 PLC-MODE/PC-MODE plc scale EST 2 (1=PLC-MODE / 0=PC-MODE)
|
|||
|
|
|||
|
Segment 6 communication scale module
|
|||
|
:JU -FB190 SCALE CONTROL
|
|||
|
Name :WAAGE
|
|||
|
W-NR : DW 1
|
|||
|
EST1 : -MW 10 I-CONTROLBITs
|
|||
|
EST2 : -MW 12 I-CONTROLBITs
|
|||
|
AST1 : -MW 14 O-CONTROLBITs
|
|||
|
AST2 : -MW 16 O-CONTROLBITs
|
|||
|
ANDB : -MW 34 ADDR.SCALE_DB
|
|||
|
DBDX : KS DB
|
|||
|
:***
|
|||
|
|
|||
|
FW 10 = MW 10 I-CONTROLBITs plc scale EST 1
|
|||
|
FW 12 = MW 12 I-CONTROLBITs plc scale EST 2
|
|||
|
FW 14 = MW 14 O-CONTROLBITs plc scale AST 1
|
|||
|
FW 16 = MW 16 O-CONTROLBITs plc scale AST 2
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
|
|||
|
FB 190 = FB190 SCALE CONTROL plc scale
|
|||
|
|
|||
|
Segment 7 got silo data
|
|||
|
:A -MA16.2 LOAD SILO DATA
|
|||
|
:= -ME10.4 GOT SILO DATA
|
|||
|
:***
|
|||
|
|
|||
|
F 16.2 = MA16.2 LOAD SILO DATA plc scale AST 2
|
|||
|
F 10.4 = ME10.4 GOT SILO DATA plc scale EST 1
|
|||
|
|
|||
|
Segment 8 silo_No ok
|
|||
|
:L DW 50
|
|||
|
:L KF +1 silo_No 1 ok
|
|||
|
:!=F
|
|||
|
:= -M 18.0 SILO_NR_OK
|
|||
|
:***
|
|||
|
|
|||
|
F 18.0 = M 18.0 SILO_NR_OK
|
|||
|
|
|||
|
Segment 9 exhaust on
|
|||
|
:A -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:= -MA24.0 VACUUMPUMP ON here: exhaust
|
|||
|
:***
|
|||
|
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 24.0 = MA24.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
|
|||
|
Segment 10 dosing release
|
|||
|
:A -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:A -M 18.0 SILO_NR_OK
|
|||
|
:A -MA24.0 VACUUMPUMP ON here: exhaust
|
|||
|
:A -ME26.0 VACUUMPUMP ON here: exhaust
|
|||
|
:A -ME26.7 CONTAINER OK
|
|||
|
:= -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:***
|
|||
|
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 18.0 = M 18.0 SILO_NR_OK
|
|||
|
F 24.0 = MA24.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
FB 21 C:ZONE10ST.S5D LEN=326
|
|||
|
Page 4
|
|||
|
F 26.0 = ME26.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
F 26.7 = ME26.7 CONTAINER OK
|
|||
|
F 11.2 = ME11.2 DOS.REL.CNTR/MAN plc scale EST 1
|
|||
|
|
|||
|
Segment 11 control weighing in tolerance ?
|
|||
|
|
|||
|
:LW =T1
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:LW =T2
|
|||
|
:T -MW182 PARAMETER 2
|
|||
|
:
|
|||
|
:JU -FB92 CONTROL_WEIGHING
|
|||
|
Name :CTR-WEIG
|
|||
|
WZNR : DW 1
|
|||
|
TOLE : DD 110
|
|||
|
TTOL : -MW180 PARAMETER 1
|
|||
|
EOCW : -M 19.2 CTRL-WEI IN TOLE
|
|||
|
TFIN : -MW182 PARAMETER 2
|
|||
|
CTRF : -M 19.1 CONTROL FINE
|
|||
|
DOSI : -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
DFIN : -ME31.3 REL CTRL-FINE
|
|||
|
:
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 19.2 = M 19.2 CTRL-WEI IN TOLE
|
|||
|
F 19.1 = M 19.1 CONTROL FINE
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 31.3 = ME31.3 REL CTRL-FINE
|
|||
|
|
|||
|
FB 92 = FB92 CONTROL_WEIGHING
|
|||
|
|
|||
|
Segment 12 release weight simulation
|
|||
|
:A -MA15.7 CNTR.WEI.DOS.ACT
|
|||
|
:A -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:A -ME27.0 DOCKING DEV DOWN
|
|||
|
:= -ME11.4 DOS.UNIT RUN.POS
|
|||
|
:
|
|||
|
:A -MA15.7 CNTR.WEI.DOS.ACT
|
|||
|
:A -MA17.1 HEAL/E.SUCK. ACT
|
|||
|
:= -MA24.6 ENABLE DOCKING D
|
|||
|
:***
|
|||
|
|
|||
|
F 15.7 = MA15.7 CNTR.WEI.DOS.ACT plc scale AST 1
|
|||
|
F 11.2 = ME11.2 DOS.REL.CNTR/MAN plc scale EST 1
|
|||
|
F 27.0 = ME27.0 DOCKING DEV DOWN
|
|||
|
F 11.4 = ME11.4 DOS.UNIT RUN.POS plc scale EST 1
|
|||
|
F 17.1 = MA17.1 HEAL/E.SUCK. ACT plc scale AST 2
|
|||
|
F 24.6 = MA24.6 ENABLE DOCKING D
|
|||
|
|
|||
|
Segment 13 receipt control weighing
|
|||
|
:A -ME27.6 SILO EMPTY dryer silo
|
|||
|
:A -M 19.2 CTRL-WEI IN TOLE
|
|||
|
:= =ECSI
|
|||
|
:A -ME27.6 SILO EMPTY u=ecsi / ???
|
|||
|
:A(
|
|||
|
:L =CPSI 01
|
|||
|
:L KF +90 01
|
|||
|
:>=F 01
|
|||
|
:) 01
|
|||
|
:A -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:S -ME10.2 RECPT.CNTR.WEIGH
|
|||
|
:AN -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
FB 21 C:ZONE10ST.S5D LEN=326
|
|||
|
Page 5
|
|||
|
:R -ME10.2 RECPT.CNTR.WEIGH
|
|||
|
:***
|
|||
|
|
|||
|
F 27.6 = ME27.6 SILO EMPTY (6)* name changed
|
|||
|
F 19.2 = M 19.2 CTRL-WEI IN TOLE
|
|||
|
F 11.2 = ME11.2 DOS.REL.CNTR/MAN plc scale EST 1
|
|||
|
F 10.2 = ME10.2 RECPT.CNTR.WEIGH plc scale EST 1
|
|||
|
|
|||
|
Segment 14 ack. register request
|
|||
|
:A -MA17.5 REGISTR.REQUEST
|
|||
|
:A -ME26.6 DOCKING DEVIC UP
|
|||
|
:= -ME13.5 REL.FOR REGISTR.
|
|||
|
:***
|
|||
|
|
|||
|
F 17.5 = MA17.5 REGISTR.REQUEST plc scale AST 2
|
|||
|
F 26.6 = ME26.6 DOCKING DEVIC UP
|
|||
|
F 13.5 = ME13.5 REL.FOR REGISTR. plc scale EST 2
|
|||
|
|
|||
|
Segment 15 max. empty level
|
|||
|
:L DD 106 max. empty weight
|
|||
|
:T FD 190
|
|||
|
:
|
|||
|
:L DW 1 scale number
|
|||
|
:L KF +100
|
|||
|
:+F
|
|||
|
:T FW 200
|
|||
|
:
|
|||
|
:DO FW 200
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:
|
|||
|
:L DD 38 scale empty level
|
|||
|
:L FD 190
|
|||
|
:>=G
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 38 scale empty level
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 16 load gross/ registrated weight
|
|||
|
:L DD 198 gross weight
|
|||
|
:T FD 190 gross weight scale
|
|||
|
:
|
|||
|
:L DD 195 registrated weight
|
|||
|
:T FD 200 registrated weight scale
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 17 empty check
|
|||
|
:DO -MW 34 ADDR.SCALE_DB
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:
|
|||
|
:L DD 106 max. empty weight
|
|||
|
:L FD 190
|
|||
|
:>=G
|
|||
|
:A(
|
|||
|
:L DD 108 01 min. empty weight
|
|||
|
:L FD 190 01
|
|||
|
:<=G 01
|
|||
|
:) 01
|
|||
|
:= =EMPY
|
|||
|
FB 21 C:ZONE10ST.S5D LEN=326
|
|||
|
Page 6
|
|||
|
:***
|
|||
|
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 18 start weight / end weight fillin
|
|||
|
:O -MA17.0 TARNG/CALMNG ACT
|
|||
|
:O D 112.0 hf taring act
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 132 start weight filling
|
|||
|
M001 :
|
|||
|
:A -MA17.0 TARNG/CALMNG ACT
|
|||
|
:S D 112.0 hf taring act
|
|||
|
:
|
|||
|
:AN -ME13.5 REL.FOR REGISTR.
|
|||
|
:JC =M002
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 134 end weight filling
|
|||
|
M002 :
|
|||
|
:L FD 200
|
|||
|
:T DD 130 registrated weight filling
|
|||
|
:***
|
|||
|
|
|||
|
F 17.0 = MA17.0 TARNG/CALMNG ACT plc scale AST 2
|
|||
|
F 13.5 = ME13.5 REL.FOR REGISTR. plc scale EST 2
|
|||
|
|
|||
|
Segment 19
|
|||
|
: from this network on starts the
|
|||
|
: discharging of the scale
|
|||
|
:
|
|||
|
:***
|
|||
|
|
|||
|
Segment 20 ack. discharging to scale module
|
|||
|
:A -MA16.4 DISCHARGE
|
|||
|
:AN -ME26.7 CONTAINER OK
|
|||
|
:= -ME10.0 RELEASE DISCHARG
|
|||
|
:
|
|||
|
:A -MA16.3 TAKEOV.WEIGHT VA
|
|||
|
:= -ME10.5 GOT WEIGHT VALUE
|
|||
|
:
|
|||
|
:O -MA16.6 FIN.DISCHARG.FIN
|
|||
|
:O -MA16.7 INT.DISCHARG.FIN
|
|||
|
:= -ME10.1 SCALE DISCHARGED
|
|||
|
:
|
|||
|
:AN -ME10.1 SCALE DISCHARGED
|
|||
|
:JC =M001
|
|||
|
:L KF +0
|
|||
|
:T DW 50 delete silo no.
|
|||
|
:T DW 51 delete consumer no.
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 16.4 = MA16.4 DISCHARGE plc scale AST 2
|
|||
|
F 26.7 = ME26.7 CONTAINER OK
|
|||
|
F 10.0 = ME10.0 RELEASE DISCHARG plc scale EST 1
|
|||
|
F 16.3 = MA16.3 TAKEOV.WEIGHT VA plc scale AST 2
|
|||
|
F 10.5 = ME10.5 GOT WEIGHT VALUE plc scale EST 1
|
|||
|
F 16.6 = MA16.6 FIN.DISCHARG.FIN plc scale AST 2
|
|||
|
F 16.7 = MA16.7 INT.DISCHARG.FIN plc scale AST 2
|
|||
|
F 10.1 = ME10.1 SCALE DISCHARGED plc scale EST 1
|
|||
|
FB 21 C:ZONE10ST.S5D LEN=326
|
|||
|
Page 7
|
|||
|
Segment 21 start weight / end weight discha
|
|||
|
:ON -MA16.5 FINAL DISCHARGE
|
|||
|
:ON -ME10.0 RELEASE DISCHARG
|
|||
|
:JC =M001
|
|||
|
:A -M 19.4 GOT_DIS_STRT WEI
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 138 start weight discharge
|
|||
|
:A -M 0.1 CONSTANT 1
|
|||
|
:S -M 19.4 GOT_DIS_STRT WEI
|
|||
|
M001 :
|
|||
|
:AN -ME10.1 SCALE DISCHARGED
|
|||
|
:JC =M002
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 140 end weight discharge
|
|||
|
M002 :
|
|||
|
:A -ME10.5 GOT WEIGHT VALUE
|
|||
|
:R -M 19.4 GOT_DIS_STRT WEI
|
|||
|
:***
|
|||
|
|
|||
|
F 16.5 = MA16.5 FINAL DISCHARGE plc scale AST 2
|
|||
|
F 10.0 = ME10.0 RELEASE DISCHARG plc scale EST 1
|
|||
|
F 19.4 = M 19.4 GOT_DIS_STRT WEI
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 10.1 = ME10.1 SCALE DISCHARGED plc scale EST 1
|
|||
|
F 10.5 = ME10.5 GOT WEIGHT VALUE plc scale EST 1
|
|||
|
|
|||
|
Segment 22 discharged weight
|
|||
|
:L DD 142 discharged weight
|
|||
|
:T DD 136 prepare for block transfer
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 23 delete report charge
|
|||
|
:L =CPSI
|
|||
|
:L KF +40
|
|||
|
:>=F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KG +0000000+00 erase
|
|||
|
:T DD 130 registrated weight
|
|||
|
:T DD 132 start weight charge
|
|||
|
:T DD 134 end weight charge
|
|||
|
:
|
|||
|
:A -M 0.1 CONSTANT 1
|
|||
|
:R D 112.0 hf taring act
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
|
|||
|
Segment 24 delete report discharge
|
|||
|
:L =DPSI
|
|||
|
:L KF +40
|
|||
|
:>=F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KG +0000000+00 erase
|
|||
|
:T DD 136 discharged weight
|
|||
|
:T DD 138 start weight discharge
|
|||
|
:T DD 140 end weight discharge
|
|||
|
:T DD 142 Discharged weight
|
|||
|
M001 :***
|
|||
|
FB 21 C:ZONE10ST.S5D LEN=326
|
|||
|
Page 8
|
|||
|
Segment 25 store status of weighing
|
|||
|
|
|||
|
:L -MW 10 I-CONTROLBITs
|
|||
|
:T DW 6
|
|||
|
:L -MW 12 I-CONTROLBITs interface to scale module
|
|||
|
:T DW 7
|
|||
|
:L -MW 14 O-CONTROLBITs
|
|||
|
:T DW 52
|
|||
|
:L -MW 16 O-CONTROLBITs
|
|||
|
:T DW 53
|
|||
|
: --------------------------------
|
|||
|
:L -MW18 STATUS FLAGS internal variable scale
|
|||
|
:T DW 114
|
|||
|
: --------------------------------
|
|||
|
:L -MW24 IND. OUTPUTS SCALE outputs / inputs
|
|||
|
:T DW 115
|
|||
|
:L -MW26 IND. INPUTS SCALE
|
|||
|
:T DW 116
|
|||
|
:L -MW30 IND. INPUTS WAY
|
|||
|
:T FW 117
|
|||
|
:L -MW30 IND. INPUTS WAY
|
|||
|
:T DW 118 --------------------------------
|
|||
|
:BE
|
|||
|
|
|||
|
FW 10 = MW 10 I-CONTROLBITs plc scale EST 1
|
|||
|
FW 12 = MW 12 I-CONTROLBITs plc scale EST 2
|
|||
|
FW 14 = MW 14 O-CONTROLBITs plc scale AST 1
|
|||
|
FW 16 = MW 16 O-CONTROLBITs plc scale AST 2
|
|||
|
FW 18 = MW18 STATUS FLAGS SCALE STATUS
|
|||
|
FW 24 = MW24 IND. OUTPUTS SCALE
|
|||
|
FW 26 = MW26 IND. INPUTS SCALE
|
|||
|
FW 30 = MW30 IND. INPUTS WAY
|
|||
|
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 1
|
|||
|
Segment 1 *(6) C2SI added
|
|||
|
Name :BL560
|
|||
|
Decl :CPSI I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :BPSI I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :DPSI I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :MPSI I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :WADB I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :C2SI I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
|
|||
|
:CX -DX201 PL6-10HO561,BD560 *(6) BD560_CHARGE
|
|||
|
:AN -M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
:JC =M001 *(6)
|
|||
|
:
|
|||
|
:CX -DX200 PL1-5 MX520,HO580 *(6) HO580_CHARGE
|
|||
|
M001 :
|
|||
|
:O D 210.0 *(6) ABORT BY PLI
|
|||
|
:O D 210.1 *(6) HOLD BY PLI
|
|||
|
:O D 211.3 *(6) ABORTED BY PLI
|
|||
|
:O D 211.0 *(6) HELD PY PLI
|
|||
|
:= F 59.4 *(6)
|
|||
|
:R -M 59.5 STOP MI BY HO580 *(6)
|
|||
|
:R -M 61.1 MILL ACTIVE *(6)
|
|||
|
:R -M 61.2 MAT. IN HO563 *(6)
|
|||
|
:R -M 61.3 MAT. IN HO584 *(6)
|
|||
|
:
|
|||
|
:C -DB30 BD560 BLENDER
|
|||
|
:L =WADB *(6)
|
|||
|
:T -MW188 ADDR_OBJECT_DB/DX *(6)
|
|||
|
:***
|
|||
|
|
|||
|
F 59.7 = M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
F 59.5 = M 59.5 STOP MI BY HO580 *(6)
|
|||
|
F 61.1 = M 61.1 MILL ACTIVE
|
|||
|
F 61.2 = M 61.2 MAT. IN HO563
|
|||
|
F 61.3 = M 61.3 MAT. IN HO584
|
|||
|
FW 188 = MW188 ADDR_OBJECT_DB/DX
|
|||
|
|
|||
|
DB 30 = DB30 BD560 BLENDER
|
|||
|
|
|||
|
DX 201 = DX201 PL6-10HO561,BD560 PL6:RES PL7-9:UNIT HO561 PL10:UNIT BD560
|
|||
|
DX 200 = DX200 PL1-5 MX520,HO580 PL1-3: UNIT MX520 PL4,5: UNIT HO580
|
|||
|
|
|||
|
Segment 2 Load scale module control bits
|
|||
|
:L KF +52
|
|||
|
:T -MW186 DW_ADDRESS
|
|||
|
:
|
|||
|
:JU -FB175 LOAD DW INDIR.
|
|||
|
Name :LADE DW
|
|||
|
DB : -MW188 ADDR_OBJECT_DB/DX *(6)
|
|||
|
DW : -MW186 DW_ADDRESS
|
|||
|
DBDX : KS DB
|
|||
|
:T -MW 14 O-CONTROLBITs
|
|||
|
: *(6)
|
|||
|
:L KF +53 *(6)
|
|||
|
:T -MW186 DW_ADDRESS *(6)
|
|||
|
: *(6)
|
|||
|
:JU -FB175 LOAD DW INDIR. *(6)
|
|||
|
Name :LADE DW
|
|||
|
DB : -MW188 ADDR_OBJECT_DB/DX *(6)
|
|||
|
DW : -MW186 DW_ADDRESS *(6)
|
|||
|
DBDX : KS DB *(6)
|
|||
|
:T -MW 16 O-CONTROLBITs *(6)
|
|||
|
:***
|
|||
|
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 2
|
|||
|
FW 186 = MW186 DW_ADDRESS
|
|||
|
FW 188 = MW188 ADDR_OBJECT_DB/DX
|
|||
|
FW 14 = MW 14 O-CONTROLBITs plc scale AST 1
|
|||
|
FW 16 = MW 16 O-CONTROLBITs plc scale AST 2
|
|||
|
|
|||
|
FB 175 = FB175 LOAD DW INDIR. sp
|
|||
|
|
|||
|
Segment 3 Load phase HO-CHARGE sub ass*(6)
|
|||
|
:L KF +200 *(6) Total network inserted!
|
|||
|
:T -MW182 PARAMETER 2
|
|||
|
:
|
|||
|
:L KF +226
|
|||
|
:T -MW184 PARAMETER 3
|
|||
|
:
|
|||
|
:JU -FB175 LOAD DW INDIR.
|
|||
|
Name :LADE DW
|
|||
|
DB : -MW182 PARAMETER 2
|
|||
|
DW : -MW184 PARAMETER 3
|
|||
|
DBDX : KS DX
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:***
|
|||
|
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
FB 175 = FB175 LOAD DW INDIR. sp
|
|||
|
|
|||
|
Segment 4 Activate Mill by HO580 *(6)
|
|||
|
:A -T80 MI5X3 heel time mil
|
|||
|
:R -M 61.1 MILL ACTIVE
|
|||
|
: charge phase 2 step index
|
|||
|
:L =C2SI *(6) Total network inserted!
|
|||
|
:L KF +40
|
|||
|
:>=F
|
|||
|
:A(
|
|||
|
:L -MW180 PARAMETER 1 01
|
|||
|
:L KF +5 01
|
|||
|
:><F 01 silo >< blender
|
|||
|
:) 01
|
|||
|
:A(
|
|||
|
:O -MA15.7 CNTR.WEI.DOS.ACT 01
|
|||
|
:O -MA15.5 POS.DOS. ACTIVE 01
|
|||
|
:) 01
|
|||
|
:S -M 61.1 MILL ACTIVE
|
|||
|
:S -M 59.7 RQ_MILL BY HO580
|
|||
|
:
|
|||
|
:AN -M 61.1 MILL ACTIVE
|
|||
|
:AN -M 61.2 MAT. IN HO563
|
|||
|
:AN -M 61.3 MAT. IN HO584
|
|||
|
:AN F 59.4
|
|||
|
:R -M 59.7 RQ_MILL BY HO580
|
|||
|
:R -M 59.5 STOP MI BY HO580
|
|||
|
:***
|
|||
|
|
|||
|
T 80 = T80 MI5X3 heel time mil MI5X3 heel time mill MI563 / MI583
|
|||
|
F 61.1 = M 61.1 MILL ACTIVE
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 15.7 = MA15.7 CNTR.WEI.DOS.ACT plc scale AST 1
|
|||
|
F 15.5 = MA15.5 POS.DOS. ACTIVE plc scale AST 1
|
|||
|
F 59.7 = M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
F 61.2 = M 61.2 MAT. IN HO563
|
|||
|
F 61.3 = M 61.3 MAT. IN HO584
|
|||
|
F 59.5 = M 59.5 STOP MI BY HO580 *(6)
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 3
|
|||
|
Segment 5 charge/hammer mill active
|
|||
|
:L =CPSI
|
|||
|
:L KF +40
|
|||
|
:>=F
|
|||
|
:A -M 60.0 STRT CHARG BD560 charge by PLI
|
|||
|
:S -M 60.1 CHARGE ACT.BD560 charge active
|
|||
|
:S -M 61.1 MILL ACTIVE mill act
|
|||
|
:
|
|||
|
:AN -M 61.1 MILL ACTIVE
|
|||
|
:AN -M 61.2 MAT. IN HO563
|
|||
|
:AN -M 61.3 MAT. IN HO584
|
|||
|
:R -M 60.1 CHARGE ACT.BD560
|
|||
|
:
|
|||
|
:A -MA17.1 HEAL/E.SUCK. ACT *(6)
|
|||
|
:A -M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
:S -M 59.5 STOP MI BY HO580 *(6)
|
|||
|
:***
|
|||
|
|
|||
|
F 60.0 = M 60.0 STRT CHARG BD560
|
|||
|
F 60.1 = M 60.1 CHARGE ACT.BD560
|
|||
|
F 61.1 = M 61.1 MILL ACTIVE
|
|||
|
F 61.2 = M 61.2 MAT. IN HO563
|
|||
|
F 61.3 = M 61.3 MAT. IN HO584
|
|||
|
F 17.1 = MA17.1 HEAL/E.SUCK. ACT plc scale AST 2
|
|||
|
F 59.7 = M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
F 59.5 = M 59.5 STOP MI BY HO580 *(6)
|
|||
|
|
|||
|
Segment 6 Load phase BD-CHARGE sub assembl
|
|||
|
:A -M 59.7 RQ_MILL BY HO580
|
|||
|
:JC =M001 *(6)
|
|||
|
:
|
|||
|
:L KF +201
|
|||
|
:T -MW182 PARAMETER 2
|
|||
|
:
|
|||
|
:L KF +226
|
|||
|
:T -MW184 PARAMETER 3
|
|||
|
:
|
|||
|
:JU -FB175 LOAD DW INDIR.
|
|||
|
Name :LADE DW
|
|||
|
DB : -MW182 PARAMETER 2
|
|||
|
DW : -MW184 PARAMETER 3
|
|||
|
DBDX : KS DX
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
M001 :*** *(6)
|
|||
|
|
|||
|
F 59.7 = M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
FB 175 = FB175 LOAD DW INDIR. sp
|
|||
|
|
|||
|
Segment 7 delay time high level free HO563
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 11
|
|||
|
AUSG : -MW186 DW_ADDRESS
|
|||
|
:
|
|||
|
:A -E 21.1=z10+b3.HO563-hli
|
|||
|
:L -MW186 DW_ADDRESS
|
|||
|
:SD -T81 HO563 high lev.free
|
|||
|
:***
|
|||
|
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 4
|
|||
|
FW 186 = MW186 DW_ADDRESS
|
|||
|
I 21.1 = E 21.1=z10+b3.HO563-hli high level indicat free HO 563
|
|||
|
T 81 = T81 HO563 high lev.free HO563 delay time high level indic. free
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 8 hammer mill /rotary feeder
|
|||
|
:O -M 66.0 BD560 SEALS OK *(6) <- *(5)
|
|||
|
:O -M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
:A( *(6)
|
|||
|
:L -MW180 PARAMETER 1 01
|
|||
|
:L KF +4 01
|
|||
|
:!=F 01
|
|||
|
:) 01 *(6)
|
|||
|
:A -M 61.1 MILL ACTIVE
|
|||
|
:A -E 22.6=z10+b3.HO561-ham
|
|||
|
:A -E 8.4=z10+b3.MI5X3-sac *(2) no E-stop
|
|||
|
:AN -E 22.7=z10+b3.HO561-com
|
|||
|
:AN -S 22.6=z10+b3.HO561-ham
|
|||
|
:AN -S 22.7=z10+b3.HO561-com
|
|||
|
:AN -S 8.4=z10+b3.MI5X3-sac *(2) no E-Stop
|
|||
|
:AN -S 9.4=z10+b3.MI563-ham
|
|||
|
:= -A 9.4=z10+b3.MI563-ham
|
|||
|
:= -A 19.4=z10+b3.MI563-coo
|
|||
|
:
|
|||
|
:A -A 9.4=z10+b3.MI563-ham
|
|||
|
:A -E 9.4=z10+b3.MI563-ham
|
|||
|
:AN -S 9.4=z10+b3.MI563-ham
|
|||
|
:A -T81 HO563 high lev.free
|
|||
|
:AN -S 9.3=z10+b3.MI563-rfe
|
|||
|
:= -A 9.3=z10+b3.MI563-rfe
|
|||
|
:***
|
|||
|
|
|||
|
F 66.0 = M 66.0 BD560 SEALS OK *(5)
|
|||
|
F 59.7 = M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 61.1 = M 61.1 MILL ACTIVE
|
|||
|
I 22.6 = E 22.6=z10+b3.HO561-ham hammer mill request HO 561
|
|||
|
I 8.4 = E 8.4=z10+b3.MI5X3-sac safety circuit all healthy MI 5X3 *(6)
|
|||
|
I 22.7 = E 22.7=z10+b3.HO561-com cone mill request HO 561
|
|||
|
S 22.6 = S 22.6=z10+b3.HO561-ham hammer mill request HO 561
|
|||
|
S 22.7 = S 22.7=z10+b3.HO561-com cone mill request HO 561
|
|||
|
S 8.4 = S 8.4=z10+b3.MI5X3-sac safety circuit all healthy MI 5X3 *(6)
|
|||
|
S 9.4 = S 9.4=z10+b3.MI563-ham hammer mill on MI 563
|
|||
|
Q 9.4 = A 9.4=z10+b3.MI563-ham hammer mill on MI 563
|
|||
|
Q 19.4 = A 19.4=z10+b3.MI563-coo cooling on MI 563
|
|||
|
I 9.4 = E 9.4=z10+b3.MI563-ham hammer mill on MI 563
|
|||
|
T 81 = T81 HO563 high lev.free HO563 delay time high level indic. free
|
|||
|
S 9.3 = S 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
Q 9.3 = A 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
|
|||
|
Segment 9 time ball vibrator
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 15
|
|||
|
AUSG : FW 202
|
|||
|
:
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 16
|
|||
|
AUSG : FW 204
|
|||
|
:
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 5
|
|||
|
:A -A 9.3=z10+b3.MI563-rfe
|
|||
|
:A -E 9.3=z10+b3.MI563-rfe
|
|||
|
:AN -S 9.3=z10+b3.MI563-rfe
|
|||
|
:= F 200.0 rel ball vibrator
|
|||
|
:***
|
|||
|
|
|||
|
Q 9.3 = A 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
I 9.3 = E 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
S 9.3 = S 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 10 clock ball vibrator MI563
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : F 200.0 release
|
|||
|
T : -T85 MI563 cyc ball vibr
|
|||
|
DWIM : FW 202
|
|||
|
DWPA : FW 204
|
|||
|
AUSG : -A 19.5=z10+b3.MI563-bvi
|
|||
|
POS : -M 0.1 CONSTANT 1
|
|||
|
DBT : -DB30 BD560 BLENDER
|
|||
|
RM : -A 19.5=z10+b3.MI563-bvi
|
|||
|
T-IN : FW 206
|
|||
|
IN : KS ..
|
|||
|
SOLL : KF +0
|
|||
|
IST : FW 208
|
|||
|
FERT : F 200.1
|
|||
|
BITL : FW 210
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB30 BD560 BLENDER
|
|||
|
:***
|
|||
|
|
|||
|
T 85 = T85 MI563 cyc ball vibr MI563 cycle ball vibrator
|
|||
|
Q 19.5 = A 19.5=z10+b3.MI563-bvi ball vibrator on MI 563
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
|
|||
|
DB 30 = DB30 BD560 BLENDER
|
|||
|
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 11 heel time mill MI563 / MI583
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 10
|
|||
|
AUSG : -MW186 DW_ADDRESS
|
|||
|
:
|
|||
|
:A -M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
:A -M 59.5 STOP MI BY HO580 *(6)
|
|||
|
:O( *(6)
|
|||
|
:AN -M 59.7 RQ_MILL BY HO580 01 *(6)
|
|||
|
:AN -M 60.0 STRT CHARG BD560 01 *(6) stop by PLI
|
|||
|
:A -E 10.2=z10+b3.BD560-sac 01 *(6)
|
|||
|
:AN -S 10.2=z10+b3.BD560-sac 01 *(6)
|
|||
|
:) 01 *(6)
|
|||
|
:A -A 9.3=z10+b3.MI563-rfe way: hammer mill
|
|||
|
:A -E 9.3=z10+b3.MI563-rfe
|
|||
|
:AN -S 9.3=z10+b3.MI563-rfe
|
|||
|
:O -A 8.1=z10+b3.MI583-fco way: cone mill
|
|||
|
:AN -A 12.4=z10+b3.HO561-ofl *(2) CHECK outlet HO561 closed
|
|||
|
:AN -E 12.4=z10+b3.HO561-ofl *(2)
|
|||
|
:A -E 16.4=z10+b3.HO561-ofl *(2)
|
|||
|
:AN -S 12.4=z10+b3.HO561-ofl *(2)
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 6
|
|||
|
:AN -S 16.4=z10+b3.HO561-ofl *(2)
|
|||
|
:L -MW186 DW_ADDRESS
|
|||
|
:SD -T80 MI5X3 heel time mil heel time mill 563 / 583
|
|||
|
:***
|
|||
|
|
|||
|
FW 186 = MW186 DW_ADDRESS
|
|||
|
F 59.7 = M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
F 59.5 = M 59.5 STOP MI BY HO580 *(6)
|
|||
|
F 60.0 = M 60.0 STRT CHARG BD560
|
|||
|
I 10.2 = E 10.2=z10+b3.BD560-sac safety circuit all healthy BD 560 *(6)
|
|||
|
S 10.2 = S 10.2=z10+b3.BD560-sac safety circuit all healthy BD 560 *(6)
|
|||
|
Q 9.3 = A 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
I 9.3 = E 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
S 9.3 = S 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
Q 8.1 = A 8.1=z10+b3.MI583-fco frequ.converter FE release MI 583
|
|||
|
Q 12.4 = A 12.4=z10+b3.HO561-ofl outletflap 1O2I open HO 561
|
|||
|
I 12.4 = E 12.4=z10+b3.HO561-ofl outletflap 1O2I open HO 561
|
|||
|
I 16.4 = E 16.4=z10+b3.HO561-ofl outletflap 1O2I closed HO 561
|
|||
|
S 12.4 = S 12.4=z10+b3.HO561-ofl outletflap 1O2I open HO 561
|
|||
|
S 16.4 = S 16.4=z10+b3.HO561-ofl outletflap 1O2I closed HO 561
|
|||
|
T 80 = T80 MI5X3 heel time mil MI5X3 heel time mill MI563 / MI583
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 12 rest discharge time HO563
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 12
|
|||
|
AUSG : -MW186 DW_ADDRESS
|
|||
|
:***
|
|||
|
|
|||
|
FW 186 = MW186 DW_ADDRESS
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 13 material in HO563
|
|||
|
:A -A 9.3=z10+b3.MI563-rfe
|
|||
|
:A -E 9.3=z10+b3.MI563-rfe
|
|||
|
:AN -S 9.3=z10+b3.MI563-rfe
|
|||
|
:S -M 61.2 MAT. IN HO563 mat in HO563
|
|||
|
:
|
|||
|
:A -M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
:A -M 59.5 STOP MI BY HO580 *(6)
|
|||
|
:O( *(6)
|
|||
|
:AN -M 59.7 RQ_MILL BY HO580 01 *(6)
|
|||
|
:AN -M 60.0 STRT CHARG BD560 01 *(6) stop by PLI
|
|||
|
:) 01 *(6)
|
|||
|
:A -M 61.2 MAT. IN HO563 mat in ho563
|
|||
|
:A -A 13.1=z10+b3.HO584-fav *(2)
|
|||
|
:A -E 13.1=z10+b3.HO584-fav *(2)
|
|||
|
:AN -S 13.1=z10+b3.HO584-fav *(2)
|
|||
|
:AN -S 17.1=z10+b3.HO584-fav *(2)
|
|||
|
:AN -A 9.4=z10+b3.MI563-ham
|
|||
|
:AN -E 9.4=z10+b3.MI563-ham
|
|||
|
:AN -S 9.4=z10+b3.MI563-ham
|
|||
|
:A -E 21.1=z10+b3.HO563-hli
|
|||
|
:A -E 20.4=z10+b2.HO584-hli
|
|||
|
:L -MW186 DW_ADDRESS
|
|||
|
:SD -T82 HO563 rest discharg rest ho563
|
|||
|
:
|
|||
|
:A -T82 HO563 rest discharg
|
|||
|
:R -M 61.2 MAT. IN HO563 mat in ho563
|
|||
|
:***
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 7
|
|||
|
Q 9.3 = A 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
I 9.3 = E 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
S 9.3 = S 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
F 61.2 = M 61.2 MAT. IN HO563
|
|||
|
F 59.7 = M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
F 59.5 = M 59.5 STOP MI BY HO580 *(6)
|
|||
|
F 60.0 = M 60.0 STRT CHARG BD560
|
|||
|
Q 13.1 = A 13.1=z10+b3.HO584-fav fresh air valve closed HO 584
|
|||
|
I 13.1 = E 13.1=z10+b3.HO584-fav fresh air valve closed HO584
|
|||
|
S 13.1 = S 13.1=z10+b3.HO584-fav fresh air valve closed HO 584
|
|||
|
S 17.1 = S 17.1=z10+b3.HO584-fav fresh air valve open HO 584
|
|||
|
Q 9.4 = A 9.4=z10+b3.MI563-ham hammer mill on MI 563
|
|||
|
I 9.4 = E 9.4=z10+b3.MI563-ham hammer mill on MI 563
|
|||
|
S 9.4 = S 9.4=z10+b3.MI563-ham hammer mill on MI 563
|
|||
|
I 21.1 = E 21.1=z10+b3.HO563-hli high level indicat free HO 563
|
|||
|
I 20.4 = E 20.4=z10+b2.HO584-hli high level indicat free HO 584
|
|||
|
FW 186 = MW186 DW_ADDRESS
|
|||
|
T 82 = T82 HO563 rest discharg HO563 rest discharge time
|
|||
|
|
|||
|
Segment 14 heel time product feeder HO584
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 14
|
|||
|
AUSG : -MW186 DW_ADDRESS
|
|||
|
:***
|
|||
|
|
|||
|
FW 186 = MW186 DW_ADDRESS
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 15 vacuum pump HO584
|
|||
|
:A -M 61.1 MILL ACTIVE
|
|||
|
:A -E 22.7=z10+b3.HO561-com
|
|||
|
:AN -E 22.6=z10+b3.HO561-ham
|
|||
|
:AN -S 22.6=z10+b3.HO561-ham
|
|||
|
:AN -S 22.7=z10+b3.HO561-com
|
|||
|
:O -M 61.2 MAT. IN HO563
|
|||
|
:A( *(6)
|
|||
|
:O -M 59.7 RQ_MILL BY HO580 01 *(6)
|
|||
|
:O -M 66.0 BD560 SEALS OK 01 *(6) <- *(5)
|
|||
|
:) 01
|
|||
|
:AN -S 7.5=z10+b3.HO584-vac
|
|||
|
:= -A 7.5=z10+b3.HO584-vac
|
|||
|
:S -M 61.3 MAT. IN HO584
|
|||
|
:
|
|||
|
:A -M 61.3 MAT. IN HO584
|
|||
|
:AN -M 61.1 MILL ACTIVE
|
|||
|
:AN -M 61.2 MAT. IN HO563
|
|||
|
:L -MW186 DW_ADDRESS
|
|||
|
:SD -T84 HO584 heel time dis
|
|||
|
:
|
|||
|
:A -T84 HO584 heel time dis
|
|||
|
:R -M 61.3 MAT. IN HO584
|
|||
|
:***
|
|||
|
|
|||
|
F 61.1 = M 61.1 MILL ACTIVE
|
|||
|
I 22.7 = E 22.7=z10+b3.HO561-com cone mill request HO 561
|
|||
|
I 22.6 = E 22.6=z10+b3.HO561-ham hammer mill request HO 561
|
|||
|
S 22.6 = S 22.6=z10+b3.HO561-ham hammer mill request HO 561
|
|||
|
S 22.7 = S 22.7=z10+b3.HO561-com cone mill request HO 561
|
|||
|
F 61.2 = M 61.2 MAT. IN HO563
|
|||
|
F 59.7 = M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
F 66.0 = M 66.0 BD560 SEALS OK *(5)
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 8
|
|||
|
S 7.5 = S 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
Q 7.5 = A 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
F 61.3 = M 61.3 MAT. IN HO584
|
|||
|
FW 186 = MW186 DW_ADDRESS
|
|||
|
T 84 = T84 HO584 heel time dis HO584 heel time dischagring
|
|||
|
|
|||
|
Segment 16 rotary feeder HO584
|
|||
|
:A -M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
:A -A 12.0=z10+b3.HO580-dse *(6)
|
|||
|
:A -E 12.0=z10+b3.HO580-dse *(6)
|
|||
|
:AN -E 16.0=z10+b3.HO580-dse *(6)
|
|||
|
:AN -S 12.0=z10+b3.HO580-dse *(6)
|
|||
|
:AN -S 16.0=z10+b3.HO580-dse *(6)
|
|||
|
:A -E 20.2=z10+b3.HO580-bin *(6)
|
|||
|
:AN -S 20.2=z10+b3.HO580-bin *(6)
|
|||
|
:A -E 21.6=z10+b3.HO580-exh *(6)
|
|||
|
:AN -S 21.6=z10+b3.HO580-exh *(6)
|
|||
|
:O( *(6)
|
|||
|
:AN -M 59.7 RQ_MILL BY HO580 01 *(6)
|
|||
|
:A -E 10.2=z10+b3.BD560-sac 01 *(6)
|
|||
|
:AN -S 10.2=z10+b3.BD560-sac 01 *(6)
|
|||
|
:AN -S 10.0=z10+b3.BD560-rbl 01 *(6)
|
|||
|
:A -E 10.1=z10+b3.BD560-fco 01 *(6)
|
|||
|
:AN -S 10.1=z10+b3.BD560-fco 01 *(6)
|
|||
|
:AN -E 11.1=z10+b3.BD560-o2: 01 *(6)
|
|||
|
:A -E 15.1=z10+b3.BD560-o2: 01 *(6)
|
|||
|
:AN -S 11.1=z10+b3.BD560-o2: 01 *(6)
|
|||
|
:AN -S 15.1=z10+b3.BD560-o2: 01 *(6)
|
|||
|
:A -E 21.4=z10+b3.BD560-lid 01 *(6)
|
|||
|
:) 01 *(6)
|
|||
|
:A -M 61.3 MAT. IN HO584
|
|||
|
:AN -S 7.7=z10+b3.HO584-rfe
|
|||
|
:= -A 7.7=z10+b3.HO584-rfe
|
|||
|
:***
|
|||
|
|
|||
|
F 59.7 = M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
Q 12.0 = A 12.0=z10+b3.HO580-dse docking seal inflate HO 580
|
|||
|
I 12.0 = E 12.0=z10+b3.HO580-dse docking seal inflate HO 580
|
|||
|
I 16.0 = E 16.0=z10+b3.HO580-dse docking seal deflate HO 580
|
|||
|
S 12.0 = S 12.0=z10+b3.HO580-dse docking seal inflate HO 580
|
|||
|
S 16.0 = S 16.0=z10+b3.HO580-dse docking seal deflate HO 580
|
|||
|
I 20.2 = E 20.2=z10+b3.HO580-bin bin available HO 580
|
|||
|
S 20.2 = S 20.2=z10+b3.HO580-bin bin available HO 580
|
|||
|
I 21.6 = E 21.6=z10+b3.HO580-exh exhaust Pfc on HO 580
|
|||
|
S 21.6 = S 21.6=z10+b3.HO580-exh exhaust Pfc on HO 580
|
|||
|
I 10.2 = E 10.2=z10+b3.BD560-sac safety circuit all healthy BD 560 *(6)
|
|||
|
S 10.2 = S 10.2=z10+b3.BD560-sac safety circuit all healthy BD 560 *(6)
|
|||
|
S 10.0 = S 10.0=z10+b3.BD560-rbl ribbon blender on BD 560
|
|||
|
I 10.1 = E 10.1=z10+b3.BD560-fco frequ.converter ready BD 560 *(5)
|
|||
|
S 10.1 = S 10.1=z10+b3.BD560-fco frequ.converter ready BD 560 *(5)
|
|||
|
I 11.1 = E 11.1=z10+b3.BD560-o2: outletflap 2O2I open BD 560
|
|||
|
I 15.1 = E 15.1=z10+b3.BD560-o2: outletflap 2O2I closed BD 560
|
|||
|
S 11.1 = S 11.1=z10+b3.BD560-o2: outletflap 2O2I open BD 560
|
|||
|
S 15.1 = S 15.1=z10+b3.BD560-o2: outletflap 2O2I closed BD 560
|
|||
|
I 21.4 = E 21.4=z10+b3.BD560-lid lid closed BD 560
|
|||
|
F 61.3 = M 61.3 MAT. IN HO584
|
|||
|
S 7.7 = S 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
Q 7.7 = A 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
|
|||
|
Segment 17 release purged air filter HO584
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +1
|
|||
|
EING : DW 21
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 9
|
|||
|
AUSG : FW 202
|
|||
|
:
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 22
|
|||
|
AUSG : FW 204
|
|||
|
:
|
|||
|
:A -A 7.7=z10+b3.HO584-rfe
|
|||
|
:L KT 030.2
|
|||
|
:SD -T96 ...................
|
|||
|
:
|
|||
|
:A -A 7.7=z10+b3.HO584-rfe
|
|||
|
:A -E 7.7=z10+b3.HO584-rfe
|
|||
|
:AN -S 7.7=z10+b3.HO584-rfe
|
|||
|
:A -T96 ...................
|
|||
|
:A -A 12.4=z10+b3.HO561-ofl
|
|||
|
:= F 200.0 release
|
|||
|
:***
|
|||
|
|
|||
|
Q 7.7 = A 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
T 96 = T96 ...................
|
|||
|
I 7.7 = E 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
S 7.7 = S 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
Q 12.4 = A 12.4=z10+b3.HO561-ofl outletflap 1O2I open HO 561
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 18 clock filter HO584
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : F 200.0 release
|
|||
|
T : -T88 HO584 cyc filter cl
|
|||
|
DWIM : FW 202
|
|||
|
DWPA : FW 204
|
|||
|
AUSG : -A 18.6=z10+b3.HO584-paf
|
|||
|
POS : -M 0.1 CONSTANT 1
|
|||
|
DBT : -DB30 BD560 BLENDER
|
|||
|
RM : -A 18.6=z10+b3.HO584-paf
|
|||
|
T-IN : FW 206
|
|||
|
IN : KS ..
|
|||
|
SOLL : KF +0
|
|||
|
IST : FW 208
|
|||
|
FERT : F 200.1
|
|||
|
BITL : FW 210
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB30 BD560 BLENDER
|
|||
|
:***
|
|||
|
|
|||
|
T 88 = T88 HO584 cyc filter cl HO584 cycle purged air filter
|
|||
|
Q 18.6 = A 18.6=z10+b3.HO584-paf purged air filter on HO 584
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
|
|||
|
DB 30 = DB30 BD560 BLENDER
|
|||
|
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 19 release vibrator HO584
|
|||
|
:A -A 7.5=z10+b3.HO584-vac
|
|||
|
:A -E 7.5=z10+b3.HO584-vac
|
|||
|
:AN -S 7.5=z10+b3.HO584-vac
|
|||
|
:A -A 7.7=z10+b3.HO584-rfe
|
|||
|
:A -E 7.7=z10+b3.HO584-rfe
|
|||
|
:AN -S 7.7=z10+b3.HO584-rfe
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 10
|
|||
|
:AN -S 7.6=z10+b3.HO584-vi:
|
|||
|
:= F 200.0 release
|
|||
|
:
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 19
|
|||
|
AUSG : FW 202
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 20
|
|||
|
AUSG : FW 204
|
|||
|
:***
|
|||
|
|
|||
|
Q 7.5 = A 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
I 7.5 = E 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
S 7.5 = S 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
Q 7.7 = A 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
I 7.7 = E 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
S 7.7 = S 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
S 7.6 = S 7.6=z10+b3.HO584-vi: vibrator on HO 584
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 20 clock vibrator HO584
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : F 200.0 release
|
|||
|
T : -T87 HO584 cyc vibrator
|
|||
|
DWIM : FW 202
|
|||
|
DWPA : FW 204
|
|||
|
AUSG : -A 7.6=z10+b3.HO584-vi:
|
|||
|
POS : -M 0.1 CONSTANT 1
|
|||
|
DBT : -DB30 BD560 BLENDER
|
|||
|
RM : -E 7.6=z10+b3.HO584-vi:
|
|||
|
T-IN : FW 206
|
|||
|
IN : KS ..
|
|||
|
SOLL : KF +0
|
|||
|
IST : FW 208
|
|||
|
FERT : F 200.1
|
|||
|
BITL : FW 210
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB30 BD560 BLENDER
|
|||
|
:***
|
|||
|
|
|||
|
T 87 = T87 HO584 cyc vibrator HO584 cycle vibration motor
|
|||
|
Q 7.6 = A 7.6=z10+b3.HO584-vi: vibrator on HO 584
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
I 7.6 = E 7.6=z10+b3.HO584-vi: vibrator on HO 584
|
|||
|
|
|||
|
DB 30 = DB30 BD560 BLENDER
|
|||
|
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 21 release ball vibrator HO584
|
|||
|
:A -A 7.5=z10+b3.HO584-vac
|
|||
|
:A -E 7.5=z10+b3.HO584-vac
|
|||
|
:AN -S 7.5=z10+b3.HO584-vac
|
|||
|
:A -A 7.7=z10+b3.HO584-rfe
|
|||
|
:A -E 7.7=z10+b3.HO584-rfe
|
|||
|
:AN -S 7.7=z10+b3.HO584-rfe
|
|||
|
:= F 200.0 release ball vibrator HO584
|
|||
|
:
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 11
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 19
|
|||
|
AUSG : FW 202
|
|||
|
:
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 20
|
|||
|
AUSG : FW 204
|
|||
|
:***
|
|||
|
|
|||
|
Q 7.5 = A 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
I 7.5 = E 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
S 7.5 = S 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
Q 7.7 = A 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
I 7.7 = E 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
S 7.7 = S 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 22 clock ball vibrator HO584
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : F 200.0 release ball vibrator HO584
|
|||
|
T : -T90 HO584 cyc ball vibr
|
|||
|
DWIM : FW 202
|
|||
|
DWPA : FW 204
|
|||
|
AUSG : -A 18.5=z10+b3.HO584-bvi
|
|||
|
POS : -M 0.1 CONSTANT 1
|
|||
|
DBT : -DB30 BD560 BLENDER
|
|||
|
RM : -A 18.5=z10+b3.HO584-bvi
|
|||
|
T-IN : FW 206
|
|||
|
IN : KS ..
|
|||
|
SOLL : KF +0
|
|||
|
IST : FW 208
|
|||
|
FERT : F 200.1
|
|||
|
BITL : FW 210
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB30 BD560 BLENDER
|
|||
|
:***
|
|||
|
|
|||
|
T 90 = T90 HO584 cyc ball vibr HO584 cycle ball vibrator
|
|||
|
Q 18.5 = A 18.5=z10+b3.HO584-bvi ball vibrator on HO 584
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
|
|||
|
DB 30 = DB30 BD560 BLENDER
|
|||
|
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 23 angle valve 563/583
|
|||
|
:A -M 61.2 MAT. IN HO563
|
|||
|
:A -A 7.5=z10+b3.HO584-vac *(6)
|
|||
|
:A -E 7.5=z10+b3.HO584-vac *(6)
|
|||
|
:AN -S 7.5=z10+b3.HO584-vac *(6)
|
|||
|
: *(6) No release ball vibr. HO584
|
|||
|
:= -A 12.7=z10+b3.HO584-anv
|
|||
|
:
|
|||
|
:A -M 61.1 MILL ACTIVE
|
|||
|
:AN -M 61.2 MAT. IN HO563 *(6)
|
|||
|
:A -A 7.5=z10+b3.HO584-vac *(6)
|
|||
|
:A -E 7.5=z10+b3.HO584-vac *(6)
|
|||
|
:AN -S 7.5=z10+b3.HO584-vac *(6)
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 12
|
|||
|
: *(6) No release ball vibr. HO584
|
|||
|
: *(2) No check key switch
|
|||
|
:= -A 13.0=z10+b3.HO584-anv
|
|||
|
:***
|
|||
|
|
|||
|
F 61.2 = M 61.2 MAT. IN HO563
|
|||
|
Q 7.5 = A 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
I 7.5 = E 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
S 7.5 = S 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
Q 12.7 = A 12.7=z10+b3.HO584-anv angle valve 1O2I 563 open HO 584
|
|||
|
F 61.1 = M 61.1 MILL ACTIVE
|
|||
|
Q 13.0 = A 13.0=z10+b3.HO584-anv angle valve 1O2I 583 open HO 584
|
|||
|
|
|||
|
Segment 24 cone mill sieve ok
|
|||
|
:L -MW180 PARAMETER 1
|
|||
|
:L KF +1
|
|||
|
:!=F
|
|||
|
:A -E 8.5=z10+b3.MI583-com
|
|||
|
:AN -E 8.6=z10+b3.MI583-com
|
|||
|
:O(
|
|||
|
:L -MW180 PARAMETER 1 01
|
|||
|
:L KF +2 01
|
|||
|
:!=F 01
|
|||
|
:AN -E 8.5=z10+b3.MI583-com 01
|
|||
|
:A -E 8.6=z10+b3.MI583-com 01
|
|||
|
:) 01
|
|||
|
:O(
|
|||
|
:L -MW180 PARAMETER 1 01
|
|||
|
:L KF +3 01
|
|||
|
:!=F 01
|
|||
|
:AN -E 8.5=z10+b3.MI583-com 01
|
|||
|
:AN -E 8.6=z10+b3.MI583-com 01
|
|||
|
:) 01
|
|||
|
:= F 200.0 cone mill sieve ok
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
I 8.5 = E 8.5=z10+b3.MI583-com cone mill sieve A MI 583
|
|||
|
I 8.6 = E 8.6=z10+b3.MI583-com cone mill sieve B MI 583
|
|||
|
|
|||
|
Segment 25 cone mill fault sieve
|
|||
|
:A -M 61.1 MILL ACTIVE
|
|||
|
:A -E 22.7=z10+b3.HO561-com
|
|||
|
:AN -E 22.6=z10+b3.HO561-ham
|
|||
|
:AN F 200.0 cone mill sieve ok
|
|||
|
:= -M 50.3 MI583 FAULT SIEV
|
|||
|
:***
|
|||
|
|
|||
|
F 61.1 = M 61.1 MILL ACTIVE
|
|||
|
I 22.7 = E 22.7=z10+b3.HO561-com cone mill request HO 561
|
|||
|
I 22.6 = E 22.6=z10+b3.HO561-ham hammer mill request HO 561
|
|||
|
F 50.3 = M 50.3 MI583 FAULT SIEV
|
|||
|
|
|||
|
Segment 26 clos fresh air valve HO563/MI583
|
|||
|
:A -A 12.7=z10+b3.HO584-anv
|
|||
|
:A -E 12.7=z10+b3.HO584-anv
|
|||
|
:AN -S 12.7=z10+b3.HO584-anv
|
|||
|
:AN -S 16.7=z10+b3.HO584-anv
|
|||
|
:O( *
|
|||
|
:A -A 13.0=z10+b3.HO584-anv 01 *
|
|||
|
:A -E 13.0=z10+b3.HO584-anv 01 *
|
|||
|
:AN -S 13.0=z10+b3.HO584-anv 01 *
|
|||
|
:AN -S 17.0=z10+b3.HO584-anv 01 *
|
|||
|
:A -E 22.7=z10+b3.HO561-com 01 ** (2) Key switch Check
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 13
|
|||
|
:AN -E 22.6=z10+b3.HO561-ham 01 ** (2)
|
|||
|
:AN -S 22.6=z10+b3.HO561-ham 01 ** (2)
|
|||
|
:AN -S 22.7=z10+b3.HO561-com 01 ** (2)
|
|||
|
:) 01 *
|
|||
|
:AN -M 62.2 HO584 PRESS.HIGH
|
|||
|
:A -T83 HO584 high lev.free
|
|||
|
:A -A 7.7=z10+b3.HO584-rfe *(6)
|
|||
|
:A -E 7.7=z10+b3.HO584-rfe *(6)
|
|||
|
:AN -S 7.7=z10+b3.HO584-rfe *(6)
|
|||
|
:= F 202.0
|
|||
|
:***
|
|||
|
|
|||
|
Q 12.7 = A 12.7=z10+b3.HO584-anv angle valve 1O2I 563 open HO 584
|
|||
|
I 12.7 = E 12.7=z10+b3.HO584-anv angle valve 1O2I 563 open HO 584
|
|||
|
S 12.7 = S 12.7=z10+b3.HO584-anv angle valve 1O2I 563 open HO 584
|
|||
|
S 16.7 = S 16.7=z10+b3.HO584-anv angle valve 1O2I 563 closed HO 584
|
|||
|
Q 13.0 = A 13.0=z10+b3.HO584-anv angle valve 1O2I 583 open HO 584
|
|||
|
I 13.0 = E 13.0=z10+b3.HO584-anv angle valve 1O2I 583 open HO 584
|
|||
|
S 13.0 = S 13.0=z10+b3.HO584-anv angle valve 1O2I 583 open HO 584
|
|||
|
S 17.0 = S 17.0=z10+b3.HO584-anv angle valve 1O2I 583 closed HO 584
|
|||
|
I 22.7 = E 22.7=z10+b3.HO561-com cone mill request HO 561
|
|||
|
I 22.6 = E 22.6=z10+b3.HO561-ham hammer mill request HO 561
|
|||
|
S 22.6 = S 22.6=z10+b3.HO561-ham hammer mill request HO 561
|
|||
|
S 22.7 = S 22.7=z10+b3.HO561-com cone mill request HO 561
|
|||
|
F 62.2 = M 62.2 HO584 PRESS.HIGH
|
|||
|
T 83 = T83 HO584 high lev.free HO584 delay time high level indic. free
|
|||
|
Q 7.7 = A 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
I 7.7 = E 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
S 7.7 = S 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
|
|||
|
Segment 27 clos fresh air valve HO563/MI583
|
|||
|
:A -E 20.3=z10+b2.HO584-sfi *(2) Correction
|
|||
|
:AN -S 20.3=z10+b2.HO584-sfi *(2) - " -
|
|||
|
:A F 202.0
|
|||
|
:S -A 13.1=z10+b3.HO584-fav *(2)
|
|||
|
:
|
|||
|
:AN F 202.0
|
|||
|
:R -A 13.1=z10+b3.HO584-fav *(2)
|
|||
|
:***
|
|||
|
|
|||
|
I 20.3 = E 20.3=z10+b2.HO584-sfi secondary filter healthy HO 584
|
|||
|
S 20.3 = S 20.3=z10+b2.HO584-sfi secondary filter healthy HO 584
|
|||
|
Q 13.1 = A 13.1=z10+b3.HO584-fav fresh air valve closed HO 584
|
|||
|
|
|||
|
Segment 28 cone mill / rotary feeder
|
|||
|
:A -M 61.3 MAT. IN HO584
|
|||
|
:A F 200.0 cone mill sieve ok
|
|||
|
:AN -S 8.2=z10+b3.MI583-com
|
|||
|
:AN -S 8.3=z10+b3.MI583-com
|
|||
|
:AN -S 8.4=z10+b3.MI5X3-sac
|
|||
|
:AN -S 8.5=z10+b3.MI583-com
|
|||
|
:AN -S 8.6=z10+b3.MI583-com
|
|||
|
:= -A 8.2=z10+b3.MI583-com
|
|||
|
:
|
|||
|
:A -M 61.3 MAT. IN HO584
|
|||
|
:A F 200.0 cone mill sieve ok
|
|||
|
:AN -S 8.0=z10+b3.MI583-rfe
|
|||
|
:AN -S 8.3=z10+b3.MI583-com
|
|||
|
:AN -S 8.4=z10+b3.MI5X3-sac
|
|||
|
:AN -S 8.5=z10+b3.MI583-com
|
|||
|
:AN -S 8.6=z10+b3.MI583-com
|
|||
|
:= -A 8.0=z10+b3.MI583-rfe
|
|||
|
:***
|
|||
|
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 14
|
|||
|
F 61.3 = M 61.3 MAT. IN HO584
|
|||
|
S 8.2 = S 8.2=z10+b3.MI583-com cone mill on MI 583
|
|||
|
S 8.3 = S 8.3=z10+b3.MI583-com cone mill locked MI 583
|
|||
|
S 8.4 = S 8.4=z10+b3.MI5X3-sac safety circuit all healthy MI 5X3 *(6)
|
|||
|
S 8.5 = S 8.5=z10+b3.MI583-com cone mill sieve A MI 583
|
|||
|
S 8.6 = S 8.6=z10+b3.MI583-com cone mill sieve B MI 583
|
|||
|
Q 8.2 = A 8.2=z10+b3.MI583-com cone mill on MI 583
|
|||
|
S 8.0 = S 8.0=z10+b3.MI583-rfe rotary feeder on MI 583
|
|||
|
Q 8.0 = A 8.0=z10+b3.MI583-rfe rotary feeder on MI 583
|
|||
|
|
|||
|
Segment 29 delay time high level free HO584
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 13
|
|||
|
AUSG : -MW186 DW_ADDRESS
|
|||
|
:
|
|||
|
:A -E 20.4=z10+b2.HO584-hli
|
|||
|
:L -MW186 DW_ADDRESS
|
|||
|
:SD -T83 HO584 high lev.free
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T FY 180 0 =P-address
|
|||
|
:L KF +134
|
|||
|
:T FY 181
|
|||
|
:***
|
|||
|
|
|||
|
FW 186 = MW186 DW_ADDRESS
|
|||
|
I 20.4 = E 20.4=z10+b2.HO584-hli high level indicat free HO 584
|
|||
|
T 83 = T83 HO584 high lev.free HO584 delay time high level indic. free
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 30 pressure transmitter
|
|||
|
:L DW 1 calibrate convey.pressure
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:O -E 7.5=z10+b3.HO584-vac
|
|||
|
:= -M 64.0 VACUUM ACT HO584
|
|||
|
:
|
|||
|
:JU -FB118 PRESSURE TRANSMIT
|
|||
|
Name :DRUCKAUF
|
|||
|
BGRN : -MW180 PARAMETER 1
|
|||
|
OG : DW 3
|
|||
|
UG : DW 2
|
|||
|
AUSG : DW 4 relative convey. pressure
|
|||
|
FEHL : F 200.0
|
|||
|
AKTV : -M 64.0 VACUUM ACT HO584
|
|||
|
TIMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
S5S7 : KS S5
|
|||
|
:***
|
|||
|
|
|||
|
I 7.5 = E 7.5=z10+b3.HO584-vac vacuumpump on HO 584
|
|||
|
F 64.0 = M 64.0 VACUUM ACT HO584
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 118 = FB118 PRESSURE TRANSMIT hkt as
|
|||
|
|
|||
|
Segment 31 pressure high
|
|||
|
:L DW 4 actual pressure
|
|||
|
:L DW 5 min pressure
|
|||
|
:>F
|
|||
|
:R -M 62.2 HO584 PRESS.HIGH
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 15
|
|||
|
:
|
|||
|
:L DW 4 actual pressure
|
|||
|
:L DW 6 max pressure
|
|||
|
:<F
|
|||
|
:O F 200.0
|
|||
|
:S -M 62.2 HO584 PRESS.HIGH
|
|||
|
:***
|
|||
|
|
|||
|
F 62.2 = M 62.2 HO584 PRESS.HIGH
|
|||
|
|
|||
|
Segment 32 output fault conveying pressure
|
|||
|
:L DW 40
|
|||
|
:T FW 202
|
|||
|
:
|
|||
|
:L KF +10
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB108 TIMER IMITATION
|
|||
|
Name :TIMER
|
|||
|
STRT : -M 62.2 HO584 PRESS.HIGH
|
|||
|
RSET : -M 0.2 CONSTANT 0
|
|||
|
AKTI : F 203.0
|
|||
|
AUSG : -M 40.2 HO584 PRES.FAULT
|
|||
|
TTYP : KS SE
|
|||
|
SOLL : -MW180 PARAMETER 1
|
|||
|
IST : DW 8
|
|||
|
IMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
:
|
|||
|
:L FW 202
|
|||
|
:T DW 40
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 62.2 = M 62.2 HO584 PRESS.HIGH
|
|||
|
F 0.2 = M 0.2 CONSTANT 0
|
|||
|
F 40.2 = M 40.2 HO584 PRES.FAULT
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 108 = FB108 TIMER IMITATION e.g. for scale control WK al
|
|||
|
|
|||
|
Segment 33 frequ. converter release MI
|
|||
|
:A -M 61.1 MILL ACTIVE
|
|||
|
:A -A 8.2=z10+b3.MI583-com
|
|||
|
:A -E 8.2=z10+b3.MI583-com
|
|||
|
:AN -S 8.2=z10+b3.MI583-com
|
|||
|
:A -E 8.7=z10+b3.MI583-fco
|
|||
|
:AN -S 8.7=z10+b3.MI583-fco
|
|||
|
:A -A 13.1=z10+b3.HO584-fav *(2)
|
|||
|
:A -E 13.1=z10+b3.HO584-fav *(2)
|
|||
|
:AN -S 13.1=z10+b3.HO584-fav *(2)
|
|||
|
:AN -S 17.1=z10+b3.HO584-fav *(2)
|
|||
|
:L KT 005.2 *(2)*
|
|||
|
:SD -T91 MI583 delay FC mill *(2)*
|
|||
|
:
|
|||
|
:A -T91 MI583 delay FC mill *(2)*
|
|||
|
:= -A 8.7=z10+b3.MI583-fco
|
|||
|
:***
|
|||
|
|
|||
|
F 61.1 = M 61.1 MILL ACTIVE
|
|||
|
Q 8.2 = A 8.2=z10+b3.MI583-com cone mill on MI 583
|
|||
|
I 8.2 = E 8.2=z10+b3.MI583-com cone mill on MI 583
|
|||
|
S 8.2 = S 8.2=z10+b3.MI583-com cone mill on MI 583
|
|||
|
I 8.7 = E 8.7=z10+b3.MI583-fco frequ.converter MI ready MI 583
|
|||
|
S 8.7 = S 8.7=z10+b3.MI583-fco frequ.converter MI ready MI 583
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 16
|
|||
|
Q 13.1 = A 13.1=z10+b3.HO584-fav fresh air valve closed HO 584
|
|||
|
I 13.1 = E 13.1=z10+b3.HO584-fav fresh air valve closed HO584
|
|||
|
S 13.1 = S 13.1=z10+b3.HO584-fav fresh air valve closed HO 584
|
|||
|
S 17.1 = S 17.1=z10+b3.HO584-fav fresh air valve open HO 584
|
|||
|
T 91 = T91 MI583 delay FC mill MI583 delay freq.converter mill *(2)
|
|||
|
Q 8.7 = A 8.7=z10+b3.MI583-fco frequ.converter MI release MI 583
|
|||
|
|
|||
|
Segment 34 value FC mill
|
|||
|
:AN -A 8.7=z10+b3.MI583-fco
|
|||
|
:L KF +0
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:A -M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
:L KF +200 *(6)
|
|||
|
:JC =M002 *(6)
|
|||
|
:L KF +201
|
|||
|
M002 :T -MW180 PARAMETER 1 *(6)
|
|||
|
:L KF +233
|
|||
|
:T -MW182 PARAMETER 2
|
|||
|
:
|
|||
|
:JU -FB175 LOAD DW INDIR.
|
|||
|
Name :LADE DW
|
|||
|
DB : -MW180 PARAMETER 1
|
|||
|
DW : -MW182 PARAMETER 2
|
|||
|
DBDX : KS DX
|
|||
|
M001 :T DW 50
|
|||
|
:***
|
|||
|
|
|||
|
Q 8.7 = A 8.7=z10+b3.MI583-fco frequ.converter MI release MI 583
|
|||
|
F 59.7 = M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
|
|||
|
FB 175 = FB175 LOAD DW INDIR. sp
|
|||
|
|
|||
|
Segment 35 set value freq.converter MI583
|
|||
|
:L KF +134
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB251 WRIT ANALOG VALUE
|
|||
|
Name :AN-AUS
|
|||
|
APW : -MW180 PARAMETER 1
|
|||
|
OG : KG +1000000+04
|
|||
|
UG : KG +0000000+00
|
|||
|
AMAX : KF +1024
|
|||
|
AMIN : KF +0
|
|||
|
WERG : FD 192
|
|||
|
WERT : DW 50
|
|||
|
G/F : KS F
|
|||
|
IN : KS IN
|
|||
|
FORM : KS ..
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
FB 251 = FB251 WRIT ANALOG VALUE
|
|||
|
|
|||
|
Segment 36 frequ. converter release FE
|
|||
|
:A -M 61.1 MILL ACTIVE
|
|||
|
:A -A 8.7=z10+b3.MI583-fco
|
|||
|
:A -A 8.0=z10+b3.MI583-rfe
|
|||
|
:A -E 8.0=z10+b3.MI583-rfe
|
|||
|
:AN -S 8.0=z10+b3.MI583-rfe
|
|||
|
:A -E 8.1=z10+b3.MI583-fco
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 17
|
|||
|
:AN -S 8.1=z10+b3.MI583-fco
|
|||
|
:A -A 13.1=z10+b3.HO584-fav *(2)
|
|||
|
:A -E 13.1=z10+b3.HO584-fav *(2)
|
|||
|
:AN -S 13.1=z10+b3.HO584-fav *(2)
|
|||
|
:AN -S 17.1=z10+b3.HO584-fav *(2)
|
|||
|
:L KT 003.2 *(2)*
|
|||
|
:SD -T92 MI583 delay FC feed *(2)*
|
|||
|
:
|
|||
|
:A -T92 MI583 delay FC feed *(2)*
|
|||
|
:= -A 8.1=z10+b3.MI583-fco
|
|||
|
:***
|
|||
|
|
|||
|
F 61.1 = M 61.1 MILL ACTIVE
|
|||
|
Q 8.7 = A 8.7=z10+b3.MI583-fco frequ.converter MI release MI 583
|
|||
|
Q 8.0 = A 8.0=z10+b3.MI583-rfe rotary feeder on MI 583
|
|||
|
I 8.0 = E 8.0=z10+b3.MI583-rfe rotary feeder on MI 583
|
|||
|
S 8.0 = S 8.0=z10+b3.MI583-rfe rotary feeder on MI 583
|
|||
|
I 8.1 = E 8.1=z10+b3.MI583-fco frequ.converter FE ready MI 583
|
|||
|
S 8.1 = S 8.1=z10+b3.MI583-fco frequ.converter FE ready MI 583
|
|||
|
Q 13.1 = A 13.1=z10+b3.HO584-fav fresh air valve closed HO 584
|
|||
|
I 13.1 = E 13.1=z10+b3.HO584-fav fresh air valve closed HO584
|
|||
|
S 13.1 = S 13.1=z10+b3.HO584-fav fresh air valve closed HO 584
|
|||
|
S 17.1 = S 17.1=z10+b3.HO584-fav fresh air valve open HO 584
|
|||
|
T 92 = T92 MI583 delay FC feed MI583 del.freq.converter rot.feeder *(2)
|
|||
|
Q 8.1 = A 8.1=z10+b3.MI583-fco frequ.converter FE release MI 583
|
|||
|
|
|||
|
Segment 37 value FC feeder
|
|||
|
:AN -A 8.1=z10+b3.MI583-fco
|
|||
|
:L KF +0
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:A -M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
:L KF +200 *(6)
|
|||
|
:JC =M002 *(6)
|
|||
|
:L KF +201
|
|||
|
M002 :T -MW180 PARAMETER 1 *(6)
|
|||
|
:L KF +234
|
|||
|
:T -MW182 PARAMETER 2
|
|||
|
:
|
|||
|
:JU -FB175 LOAD DW INDIR.
|
|||
|
Name :LADE DW
|
|||
|
DB : -MW180 PARAMETER 1
|
|||
|
DW : -MW182 PARAMETER 2
|
|||
|
DBDX : KS DX
|
|||
|
M001 :T DW 51
|
|||
|
:***
|
|||
|
|
|||
|
Q 8.1 = A 8.1=z10+b3.MI583-fco frequ.converter FE release MI 583
|
|||
|
F 59.7 = M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
|
|||
|
FB 175 = FB175 LOAD DW INDIR. sp
|
|||
|
|
|||
|
Segment 38 set value freq.converter FE583
|
|||
|
:L KF +132
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB251 WRIT ANALOG VALUE
|
|||
|
Name :AN-AUS
|
|||
|
APW : -MW180 PARAMETER 1
|
|||
|
OG : KG +1000000+04
|
|||
|
UG : KG +0000000+00
|
|||
|
AMAX : KF +1024
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 18
|
|||
|
AMIN : KF +0
|
|||
|
WERG : FD 192
|
|||
|
WERT : DW 51
|
|||
|
G/F : KS F
|
|||
|
IN : KS IN
|
|||
|
FORM : KS ..
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
FB 251 = FB251 WRIT ANALOG VALUE
|
|||
|
|
|||
|
Segment 39 time vibrator HO563
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 17
|
|||
|
AUSG : FW 202
|
|||
|
:
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 18
|
|||
|
AUSG : FW 204
|
|||
|
:
|
|||
|
:A -M 61.2 MAT. IN HO563
|
|||
|
:A -A 13.1=z10+b3.HO584-fav *(2)
|
|||
|
:A -E 13.1=z10+b3.HO584-fav *(2)
|
|||
|
:AN -S 13.1=z10+b3.HO584-fav *(2)
|
|||
|
:AN -S 17.1=z10+b3.HO584-fav *(2)
|
|||
|
:AN -S 9.5=z10+b3.HO563-vi:
|
|||
|
:= F 200.0 release
|
|||
|
:***
|
|||
|
|
|||
|
F 61.2 = M 61.2 MAT. IN HO563
|
|||
|
Q 13.1 = A 13.1=z10+b3.HO584-fav fresh air valve closed HO 584
|
|||
|
I 13.1 = E 13.1=z10+b3.HO584-fav fresh air valve closed HO584
|
|||
|
S 13.1 = S 13.1=z10+b3.HO584-fav fresh air valve closed HO 584
|
|||
|
S 17.1 = S 17.1=z10+b3.HO584-fav fresh air valve open HO 584
|
|||
|
S 9.5 = S 9.5=z10+b3.HO563-vi: vibrator on HO 563
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 40 clock vibrator HO563
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : F 200.0 release
|
|||
|
T : -T86 HO563 cyc vibrator
|
|||
|
DWIM : FW 202
|
|||
|
DWPA : FW 204
|
|||
|
AUSG : -A 9.5=z10+b3.HO563-vi:
|
|||
|
POS : -M 0.1 CONSTANT 1
|
|||
|
DBT : -DB30 BD560 BLENDER
|
|||
|
RM : -E 9.5=z10+b3.HO563-vi:
|
|||
|
T-IN : FW 206
|
|||
|
IN : KS ..
|
|||
|
SOLL : KF +0
|
|||
|
IST : FW 208
|
|||
|
FERT : F 200.1
|
|||
|
BITL : FW 210
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB30 BD560 BLENDER
|
|||
|
:***
|
|||
|
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 19
|
|||
|
T 86 = T86 HO563 cyc vibrator HO563 cycle vibration motor
|
|||
|
Q 9.5 = A 9.5=z10+b3.HO563-vi: vibrator on HO 563
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
I 9.5 = E 9.5=z10+b3.HO563-vi: vibrator on HO 563
|
|||
|
|
|||
|
DB 30 = DB30 BD560 BLENDER
|
|||
|
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 41 Mode blender
|
|||
|
:L DW 41
|
|||
|
:L KF +0
|
|||
|
:!=F
|
|||
|
:= -M 62.6 BD560 AUTO-MODE
|
|||
|
:
|
|||
|
:L DW 41
|
|||
|
:L KF +1
|
|||
|
:!=F
|
|||
|
:= -M 62.7 BD560 MANUAL-MOD
|
|||
|
:***
|
|||
|
|
|||
|
F 62.6 = M 62.6 BD560 AUTO-MODE
|
|||
|
F 62.7 = M 62.7 BD560 MANUAL-MOD
|
|||
|
|
|||
|
Segment 42 blender start on charge
|
|||
|
:A -M 62.7 BD560 MANUAL-MOD
|
|||
|
:A -E 22.4=z10+b3.BD560-bl: button blender start
|
|||
|
:O -M 62.6 BD560 AUTO-MODE
|
|||
|
:AN -M 62.2 HO584 PRESS.HIGH
|
|||
|
:A(
|
|||
|
:A -A 9.3=z10+b3.MI563-rfe 01
|
|||
|
:A -E 9.3=z10+b3.MI563-rfe 01
|
|||
|
:O -A 8.1=z10+b3.MI583-fco 01
|
|||
|
:AN -S 13.1=z10+b3.HO584-fav 01 *(2)
|
|||
|
:AN -S 17.1=z10+b3.HO584-fav 01 *(2)
|
|||
|
:A -A 7.7=z10+b3.HO584-rfe 01 *(2)
|
|||
|
:A -E 7.7=z10+b3.HO584-rfe 01 *(2)
|
|||
|
:) 01
|
|||
|
:A -A 12.4=z10+b3.HO561-ofl
|
|||
|
:A -E 12.4=z10+b3.HO561-ofl
|
|||
|
:AN -M 59.7 RQ_MILL BY HO580
|
|||
|
:= -M 61.4 BD560-STRT CHARG
|
|||
|
: *(6)
|
|||
|
:
|
|||
|
:
|
|||
|
: *(5) u a10.0
|
|||
|
:A -A 10.1=z10+b3.BD560-fco *(5) u e10.0
|
|||
|
:A -M 61.4 BD560-STRT CHARG *(5) un s10.0
|
|||
|
:= F 200.0 *(5)
|
|||
|
:***
|
|||
|
|
|||
|
F 62.7 = M 62.7 BD560 MANUAL-MOD
|
|||
|
I 22.4 = E 22.4=z10+b3.BD560-bl: blender start BD 560
|
|||
|
F 62.6 = M 62.6 BD560 AUTO-MODE
|
|||
|
F 62.2 = M 62.2 HO584 PRESS.HIGH
|
|||
|
Q 9.3 = A 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
I 9.3 = E 9.3=z10+b3.MI563-rfe rotary feeder on MI 563
|
|||
|
Q 8.1 = A 8.1=z10+b3.MI583-fco frequ.converter FE release MI 583
|
|||
|
S 13.1 = S 13.1=z10+b3.HO584-fav fresh air valve closed HO 584
|
|||
|
S 17.1 = S 17.1=z10+b3.HO584-fav fresh air valve open HO 584
|
|||
|
Q 7.7 = A 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
I 7.7 = E 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
Q 12.4 = A 12.4=z10+b3.HO561-ofl outletflap 1O2I open HO 561
|
|||
|
I 12.4 = E 12.4=z10+b3.HO561-ofl outletflap 1O2I open HO 561
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 20
|
|||
|
F 59.7 = M 59.7 RQ_MILL BY HO580 *(6)
|
|||
|
F 61.4 = M 61.4 BD560-STRT CHARG
|
|||
|
Q 10.1 = A 10.1=z10+b3.BD560-fco frequ.converter release BD 560 *(5)
|
|||
|
|
|||
|
Segment 43 Measure blender charge time
|
|||
|
:L DW 40
|
|||
|
:T FW 202
|
|||
|
:
|
|||
|
:L KF +32767
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB 9 TIME MEASURING
|
|||
|
Name :TIMER
|
|||
|
STRT : F 200.0 measure on charge
|
|||
|
RSET : -M 61.0 RESET ALL BLTIME
|
|||
|
AKTI : F 202.0
|
|||
|
AUSG : F 202.1
|
|||
|
TTYP : KS SE
|
|||
|
SOLL : -MW180 PARAMETER 1
|
|||
|
IST : DW 30
|
|||
|
IMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 61.0 = M 61.0 RESET ALL BLTIME
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 9 = FB 9 TIME MEASURING
|
|||
|
|
|||
|
Segment 44 Measure blender charge revolut.
|
|||
|
:L KG +1701412+39
|
|||
|
:T FD 180
|
|||
|
:L KG +2500000+00
|
|||
|
:T FD 184
|
|||
|
:
|
|||
|
:JU -FB 8 COUNT PULSE
|
|||
|
Name :COUNTER
|
|||
|
STRT : F 200.0 measure on charge
|
|||
|
RSET : -M 61.0 RESET ALL BLTIME
|
|||
|
AKTI : F 203.0
|
|||
|
AUSG : F 203.1
|
|||
|
SOLL : FD 180
|
|||
|
IST : DD 42
|
|||
|
IMP : -E 21.3=z10+b3.BD560-rot
|
|||
|
H-IM : -M 63.3 H-IMP CHAR BD560
|
|||
|
EINH : FD 184
|
|||
|
:
|
|||
|
:L FW 202
|
|||
|
:T DW 40
|
|||
|
:***
|
|||
|
|
|||
|
F 61.0 = M 61.0 RESET ALL BLTIME
|
|||
|
I 21.3 = E 21.3=z10+b3.BD560-rot rotation impulse BD 560
|
|||
|
F 63.3 = M 63.3 H-IMP CHAR BD560
|
|||
|
|
|||
|
FB 8 = FB 8 COUNT PULSE
|
|||
|
|
|||
|
Segment 45 manual addition release
|
|||
|
:AN -A 10.0=z10+b3.BD560-rbl
|
|||
|
:AN -E 10.0=z10+b3.BD560-rbl
|
|||
|
:AN -S 10.0=z10+b3.BD560-rbl blender off
|
|||
|
:AN -E 7.7=z10+b3.HO584-rfe hopper rotary feeder off
|
|||
|
:= F 200.0 addition release
|
|||
|
:***
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 21
|
|||
|
Q 10.0 = A 10.0=z10+b3.BD560-rbl ribbon blender on BD 560
|
|||
|
I 10.0 = E 10.0=z10+b3.BD560-rbl ribbon blender on BD 560
|
|||
|
S 10.0 = S 10.0=z10+b3.BD560-rbl ribbon blender on BD 560
|
|||
|
I 7.7 = E 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
|
|||
|
Segment 46 lock manual addition
|
|||
|
:L =MPSI
|
|||
|
:L KF +40
|
|||
|
:>=F
|
|||
|
:A -M 61.5 LOCK ACTIVE BL
|
|||
|
:A F 200.0 addition release
|
|||
|
:O -M 62.4 BD560 OFF CHK EM
|
|||
|
:A -E 21.4=z10+b3.BD560-lid
|
|||
|
:AN -A 10.0=z10+b3.BD560-rbl
|
|||
|
:AN -E 10.0=z10+b3.BD560-rbl
|
|||
|
:AN -S 10.0=z10+b3.BD560-rbl
|
|||
|
:= F 230.0 *= A20.0 lock blender NOT exist!
|
|||
|
:***
|
|||
|
|
|||
|
F 61.5 = M 61.5 LOCK ACTIVE BL
|
|||
|
F 62.4 = M 62.4 BD560 OFF CHK EM
|
|||
|
I 21.4 = E 21.4=z10+b3.BD560-lid lid closed BD 560
|
|||
|
Q 10.0 = A 10.0=z10+b3.BD560-rbl ribbon blender on BD 560
|
|||
|
I 10.0 = E 10.0=z10+b3.BD560-rbl ribbon blender on BD 560
|
|||
|
S 10.0 = S 10.0=z10+b3.BD560-rbl ribbon blender on BD 560
|
|||
|
|
|||
|
Segment 47 check empty ?
|
|||
|
:JU -FB109 LUMINOUS PUSH-BUT
|
|||
|
Name :L-TAST
|
|||
|
EING : -E 23.2=z10+b3.BD560-chk
|
|||
|
AUSG : -M 62.4 BD560 OFF CHK EM
|
|||
|
FOLG : -M 62.5 HF BD560 OFF CHK
|
|||
|
RESE : -M 0.2 CONSTANT 0
|
|||
|
:
|
|||
|
:AN -M 62.3 BD560 CHECK EMPT
|
|||
|
:R -M 62.4 BD560 OFF CHK EM
|
|||
|
:R -M 62.5 HF BD560 OFF CHK
|
|||
|
:
|
|||
|
:O(
|
|||
|
:AN -M 62.4 BD560 OFF CHK EM 01
|
|||
|
:A -M 0.4 FLASH CLOCK FAST 01
|
|||
|
:) 01
|
|||
|
:O -M 62.4 BD560 OFF CHK EM
|
|||
|
:A -M 62.3 BD560 CHECK EMPT
|
|||
|
:O -M 4.5 GLOBAL LAMBTEST
|
|||
|
:= -A 23.2=z10+b3.BD560-chk
|
|||
|
:***
|
|||
|
|
|||
|
I 23.2 = E 23.2=z10+b3.BD560-chk check empty BD 560
|
|||
|
F 62.4 = M 62.4 BD560 OFF CHK EM
|
|||
|
F 62.5 = M 62.5 HF BD560 OFF CHK
|
|||
|
F 0.2 = M 0.2 CONSTANT 0
|
|||
|
F 62.3 = M 62.3 BD560 CHECK EMPT
|
|||
|
F 0.4 = M 0.4 FLASH CLOCK FAST
|
|||
|
F 4.5 = M 4.5 GLOBAL LAMBTEST
|
|||
|
Q 23.2 = A 23.2=z10+b3.BD560-chk check empty BD 560
|
|||
|
|
|||
|
FB 109 = FB109 LUMINOUS PUSH-BUT 06.11.92 Hkt al
|
|||
|
|
|||
|
Segment 48 manual addition permitted
|
|||
|
:A -M 61.5 LOCK ACTIVE BL
|
|||
|
:A F 200.0 addition release
|
|||
|
:= D 7.0 addition permitted
|
|||
|
:
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 22
|
|||
|
:AN -E 21.4=z10+b3.BD560-lid
|
|||
|
:AN -M 61.5 LOCK ACTIVE BL
|
|||
|
:A -M 0.4 FLASH CLOCK FAST
|
|||
|
:O(
|
|||
|
:A -M 61.5 LOCK ACTIVE BL 01
|
|||
|
:A F 200.0 01 addition release
|
|||
|
:) 01
|
|||
|
:O -M 4.5 GLOBAL LAMBTEST
|
|||
|
:= -A 22.2=z10+b3.BD560-mad
|
|||
|
:***
|
|||
|
|
|||
|
F 61.5 = M 61.5 LOCK ACTIVE BL
|
|||
|
I 21.4 = E 21.4=z10+b3.BD560-lid lid closed BD 560
|
|||
|
F 0.4 = M 0.4 FLASH CLOCK FAST
|
|||
|
F 4.5 = M 4.5 GLOBAL LAMBTEST
|
|||
|
Q 22.2 = A 22.2=z10+b3.BD560-mad manual addittion permitted BD 560
|
|||
|
|
|||
|
Segment 49 blending
|
|||
|
:L =BPSI
|
|||
|
:L KF +40
|
|||
|
:!=F
|
|||
|
:A -M 60.2 STRT BLEND BD560 blend by PLI
|
|||
|
:AN -E 7.7=z10+b3.HO584-rfe hopper feeder off
|
|||
|
:A -E 15.1=z10+b3.BD560-o2: outletflap 2 closed
|
|||
|
:A -E 10.2=z10+b3.BD560-sac *(6) <- *(2) safety circ.healthy
|
|||
|
:AN -S 7.7=z10+b3.HO584-rfe no faults feeder / flap / safety
|
|||
|
:AN -S 11.1=z10+b3.BD560-o2:
|
|||
|
:AN -S 15.1=z10+b3.BD560-o2:
|
|||
|
:AN -S 10.2=z10+b3.BD560-sac *(6) <- *(2)
|
|||
|
:= -M 61.7 BD560-STRT BLEND
|
|||
|
:
|
|||
|
: *(5) u a10.0
|
|||
|
: *(5) u e10.0
|
|||
|
: *(5) un s10.0
|
|||
|
:A -A 10.1=z10+b3.BD560-fco *(5)
|
|||
|
:A -M 61.7 BD560-STRT BLEND blending start
|
|||
|
:= F 200.0 measure on blend
|
|||
|
:***
|
|||
|
|
|||
|
F 60.2 = M 60.2 STRT BLEND BD560
|
|||
|
I 7.7 = E 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
I 15.1 = E 15.1=z10+b3.BD560-o2: outletflap 2O2I closed BD 560
|
|||
|
I 10.2 = E 10.2=z10+b3.BD560-sac safety circuit all healthy BD 560 *(6)
|
|||
|
S 7.7 = S 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
S 11.1 = S 11.1=z10+b3.BD560-o2: outletflap 2O2I open BD 560
|
|||
|
S 15.1 = S 15.1=z10+b3.BD560-o2: outletflap 2O2I closed BD 560
|
|||
|
S 10.2 = S 10.2=z10+b3.BD560-sac safety circuit all healthy BD 560 *(6)
|
|||
|
F 61.7 = M 61.7 BD560-STRT BLEND
|
|||
|
Q 10.1 = A 10.1=z10+b3.BD560-fco frequ.converter release BD 560 *(5)
|
|||
|
|
|||
|
Segment 50 Measure blender blend time
|
|||
|
:L DW 40
|
|||
|
:T FW 202
|
|||
|
:
|
|||
|
:JU -FB 9 TIME MEASURING
|
|||
|
Name :TIMER
|
|||
|
STRT : -A 10.1=z10+b3.BD560-fco measure on blend (5)*
|
|||
|
RSET : -M 61.0 RESET ALL BLTIME
|
|||
|
AKTI : F 202.2
|
|||
|
AUSG : -M 60.3 BLE.TIME OVER BL
|
|||
|
TTYP : KS SE
|
|||
|
SOLL : DW 28
|
|||
|
IST : DW 31
|
|||
|
IMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 23
|
|||
|
:***
|
|||
|
|
|||
|
Q 10.1 = A 10.1=z10+b3.BD560-fco frequ.converter release BD 560 *(5)
|
|||
|
F 61.0 = M 61.0 RESET ALL BLTIME
|
|||
|
F 60.3 = M 60.3 BLE.TIME OVER BL
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 9 = FB 9 TIME MEASURING
|
|||
|
|
|||
|
Segment 51 Measure blender blend revolut.
|
|||
|
:L KG +1701412+39
|
|||
|
:T FD 180
|
|||
|
:L KG +2500000+00
|
|||
|
:T FD 184
|
|||
|
:
|
|||
|
:JU -FB 8 COUNT PULSE
|
|||
|
Name :COUNTER
|
|||
|
STRT : F 200.0 measure on blend
|
|||
|
RSET : -M 61.0 RESET ALL BLTIME
|
|||
|
AKTI : F 203.2
|
|||
|
AUSG : F 203.3
|
|||
|
SOLL : FD 180
|
|||
|
IST : DD 44
|
|||
|
IMP : -E 21.3=z10+b3.BD560-rot
|
|||
|
H-IM : -M 63.4 H-IMP BLEN BD560
|
|||
|
EINH : FD 184
|
|||
|
:
|
|||
|
:L FW 202
|
|||
|
:T DW 40
|
|||
|
:***
|
|||
|
|
|||
|
F 61.0 = M 61.0 RESET ALL BLTIME
|
|||
|
I 21.3 = E 21.3=z10+b3.BD560-rot rotation impulse BD 560
|
|||
|
F 63.4 = M 63.4 H-IMP BLEN BD560
|
|||
|
|
|||
|
FB 8 = FB 8 COUNT PULSE
|
|||
|
|
|||
|
Segment 52 discharge active
|
|||
|
:L =DPSI
|
|||
|
:L KF +40
|
|||
|
:>=F
|
|||
|
:A(
|
|||
|
:O -M 60.4 STRT DISCH.BD560 01 discharge by PLI
|
|||
|
:O -M 62.1 STRT DINOP BD560 01 discharge_nop by PLI
|
|||
|
:) 01
|
|||
|
:= F 200.0 discharge active
|
|||
|
:
|
|||
|
:O F 200.0 discharge active
|
|||
|
:O -M 4.5 GLOBAL LAMBTEST
|
|||
|
:= -A 22.3=z10+b3.BD560-dis
|
|||
|
:***
|
|||
|
|
|||
|
F 60.4 = M 60.4 STRT DISCH.BD560
|
|||
|
F 62.1 = M 62.1 STRT DINOP BD560
|
|||
|
F 4.5 = M 4.5 GLOBAL LAMBTEST
|
|||
|
Q 22.3 = A 22.3=z10+b3.BD560-dis discharge active BD 560
|
|||
|
|
|||
|
Segment 53 enable discharge active
|
|||
|
:A -A 18.7=z10+b3.HO580-exh
|
|||
|
:A -E 21.6=z10+b3.HO580-exh
|
|||
|
:AN -S 21.6=z10+b3.HO580-exh
|
|||
|
:A -A 12.0=z10+b3.HO580-dse
|
|||
|
:A -E 12.0=z10+b3.HO580-dse
|
|||
|
:AN -E 16.0=z10+b3.HO580-dse
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 24
|
|||
|
:AN -S 12.0=z10+b3.HO580-dse
|
|||
|
:AN -S 16.0=z10+b3.HO580-dse
|
|||
|
:A -E 10.2=z10+b3.BD560-sac *(6) <- *(2)
|
|||
|
:AN -S 10.2=z10+b3.BD560-sac *(6) <- *(2)
|
|||
|
:A F 200.0 discharge active
|
|||
|
:= F 201.0 enable discharge active
|
|||
|
:***
|
|||
|
|
|||
|
Q 18.7 = A 18.7=z10+b3.HO580-exh exhaust Pfc on HO 580
|
|||
|
I 21.6 = E 21.6=z10+b3.HO580-exh exhaust Pfc on HO 580
|
|||
|
S 21.6 = S 21.6=z10+b3.HO580-exh exhaust Pfc on HO 580
|
|||
|
Q 12.0 = A 12.0=z10+b3.HO580-dse docking seal inflate HO 580
|
|||
|
I 12.0 = E 12.0=z10+b3.HO580-dse docking seal inflate HO 580
|
|||
|
I 16.0 = E 16.0=z10+b3.HO580-dse docking seal deflate HO 580
|
|||
|
S 12.0 = S 12.0=z10+b3.HO580-dse docking seal inflate HO 580
|
|||
|
S 16.0 = S 16.0=z10+b3.HO580-dse docking seal deflate HO 580
|
|||
|
I 10.2 = E 10.2=z10+b3.BD560-sac safety circuit all healthy BD 560 *(6)
|
|||
|
S 10.2 = S 10.2=z10+b3.BD560-sac safety circuit all healthy BD 560 *(6)
|
|||
|
|
|||
|
Segment 54 Release discharge to bins
|
|||
|
:JU -FB109 LUMINOUS PUSH-BUT
|
|||
|
Name :L-TAST
|
|||
|
EING : -E 23.3=z10+b3.BD560-dis
|
|||
|
AUSG : -M 60.6 REL BIN-DI.BD560
|
|||
|
FOLG : -M 60.7 HF BIN-DIS.BD560
|
|||
|
RESE : -M 0.2 CONSTANT 0
|
|||
|
:
|
|||
|
:AN F 201.0 enable discharge active
|
|||
|
:R -M 60.6 REL BIN-DI.BD560
|
|||
|
:R -M 60.7 HF BIN-DIS.BD560
|
|||
|
:
|
|||
|
:A F 201.0 enable discharge active
|
|||
|
:A -E 11.1=z10+b3.BD560-o2:
|
|||
|
:O -M 4.5 GLOBAL LAMBTEST
|
|||
|
:= -A 23.3=z10+b3.BD560-dis
|
|||
|
:***
|
|||
|
|
|||
|
I 23.3 = E 23.3=z10+b3.BD560-dis discharge open BD 560
|
|||
|
F 60.6 = M 60.6 REL BIN-DI.BD560
|
|||
|
F 60.7 = M 60.7 HF BIN-DIS.BD560
|
|||
|
F 0.2 = M 0.2 CONSTANT 0
|
|||
|
I 11.1 = E 11.1=z10+b3.BD560-o2: outletflap 2O2I open BD 560
|
|||
|
F 4.5 = M 4.5 GLOBAL LAMBTEST
|
|||
|
Q 23.3 = A 23.3=z10+b3.BD560-dis discharge open BD 560
|
|||
|
|
|||
|
FB 109 = FB109 LUMINOUS PUSH-BUT 06.11.92 Hkt al
|
|||
|
|
|||
|
Segment 55 open outletflap
|
|||
|
:O(
|
|||
|
:A -M 62.1 STRT DINOP BD560 01
|
|||
|
:A -M 60.6 REL BIN-DI.BD560 01
|
|||
|
:) 01
|
|||
|
:O(
|
|||
|
:A -M 62.7 BD560 MANUAL-MOD 01
|
|||
|
:A -M 60.6 REL BIN-DI.BD560 01
|
|||
|
:O -M 62.6 BD560 AUTO-MODE 01
|
|||
|
:A -MA15.6 CNTR.WEIGH.ACTIV 01
|
|||
|
:A -M 60.4 STRT DISCH.BD560 01
|
|||
|
:A -E 20.2=z10+b3.HO580-bin 01
|
|||
|
:AN -S 20.2=z10+b3.HO580-bin 01
|
|||
|
:) 01
|
|||
|
:A F 201.0 enable discharge active
|
|||
|
:AN -E 7.7=z10+b3.HO584-rfe
|
|||
|
:AN -S 7.7=z10+b3.HO584-rfe
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 25
|
|||
|
:= -A 11.1=z10+b3.BD560-o2:
|
|||
|
:AN -A 11.1=z10+b3.BD560-o2:
|
|||
|
:AN -E 15.1=z10+b3.BD560-o2:
|
|||
|
:= -A 15.1=z10+b3.BD560-o2:
|
|||
|
:***
|
|||
|
|
|||
|
F 62.1 = M 62.1 STRT DINOP BD560
|
|||
|
F 60.6 = M 60.6 REL BIN-DI.BD560
|
|||
|
F 62.7 = M 62.7 BD560 MANUAL-MOD
|
|||
|
F 62.6 = M 62.6 BD560 AUTO-MODE
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 60.4 = M 60.4 STRT DISCH.BD560
|
|||
|
I 20.2 = E 20.2=z10+b3.HO580-bin bin available HO 580
|
|||
|
S 20.2 = S 20.2=z10+b3.HO580-bin bin available HO 580
|
|||
|
I 7.7 = E 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
S 7.7 = S 7.7=z10+b3.HO584-rfe rotary feeder on HO 584
|
|||
|
Q 11.1 = A 11.1=z10+b3.BD560-o2: outletflap 2O2I open BD 560
|
|||
|
I 15.1 = E 15.1=z10+b3.BD560-o2: outletflap 2O2I closed BD 560
|
|||
|
Q 15.1 = A 15.1=z10+b3.BD560-o2: outletflap 2O2I closed BD 560
|
|||
|
|
|||
|
Segment 56 discharging
|
|||
|
:A -M 60.4 STRT DISCH.BD560
|
|||
|
:A -M 62.7 BD560 MANUAL-MOD
|
|||
|
:O -M 62.1 STRT DINOP BD560
|
|||
|
:A -E 22.4=z10+b3.BD560-bl: button blender start
|
|||
|
:O(
|
|||
|
:A -M 60.4 STRT DISCH.BD560 01
|
|||
|
:A -M 62.6 BD560 AUTO-MODE 01
|
|||
|
:) 01
|
|||
|
:A -A 11.1=z10+b3.BD560-o2:
|
|||
|
:A -E 11.1=z10+b3.BD560-o2:
|
|||
|
:AN -S 11.1=z10+b3.BD560-o2:
|
|||
|
:AN -S 15.1=z10+b3.BD560-o2:
|
|||
|
:= -M 62.0 BD560-STRT DISCH discharge start
|
|||
|
:
|
|||
|
: *(5) u a10.0
|
|||
|
: *(5) u e10.0
|
|||
|
: *(5) un s10.0
|
|||
|
:A -A 10.1=z10+b3.BD560-fco *(5)
|
|||
|
:A -M 62.0 BD560-STRT DISCH discharge start
|
|||
|
:= F 200.0 measure on discharge
|
|||
|
:***
|
|||
|
|
|||
|
F 60.4 = M 60.4 STRT DISCH.BD560
|
|||
|
F 62.7 = M 62.7 BD560 MANUAL-MOD
|
|||
|
F 62.1 = M 62.1 STRT DINOP BD560
|
|||
|
I 22.4 = E 22.4=z10+b3.BD560-bl: blender start BD 560
|
|||
|
F 62.6 = M 62.6 BD560 AUTO-MODE
|
|||
|
Q 11.1 = A 11.1=z10+b3.BD560-o2: outletflap 2O2I open BD 560
|
|||
|
I 11.1 = E 11.1=z10+b3.BD560-o2: outletflap 2O2I open BD 560
|
|||
|
S 11.1 = S 11.1=z10+b3.BD560-o2: outletflap 2O2I open BD 560
|
|||
|
S 15.1 = S 15.1=z10+b3.BD560-o2: outletflap 2O2I closed BD 560
|
|||
|
F 62.0 = M 62.0 BD560-STRT DISCH
|
|||
|
Q 10.1 = A 10.1=z10+b3.BD560-fco frequ.converter release BD 560 *(5)
|
|||
|
|
|||
|
Segment 57 Measure blender discharge time
|
|||
|
:L DW 40
|
|||
|
:T FW 202
|
|||
|
:
|
|||
|
:JU -FB 9 TIME MEASURING
|
|||
|
Name :TIMER
|
|||
|
STRT : F 200.0 measure on discharge
|
|||
|
RSET : -M 61.0 RESET ALL BLTIME
|
|||
|
AKTI : F 202.4
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 26
|
|||
|
AUSG : F 202.5
|
|||
|
TTYP : KS SE
|
|||
|
SOLL : DW 29
|
|||
|
IST : DW 32
|
|||
|
IMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
:
|
|||
|
:A F 202.5
|
|||
|
:S -M 60.5 DIS.TIME OVER BL
|
|||
|
:
|
|||
|
:A -M 61.0 RESET ALL BLTIME
|
|||
|
:R -M 60.5 DIS.TIME OVER BL
|
|||
|
:***
|
|||
|
|
|||
|
F 61.0 = M 61.0 RESET ALL BLTIME
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
F 60.5 = M 60.5 DIS.TIME OVER BL
|
|||
|
|
|||
|
FB 9 = FB 9 TIME MEASURING
|
|||
|
|
|||
|
Segment 58 Measure blender discharge revol.
|
|||
|
:L KG +1701412+39
|
|||
|
:T FD 180
|
|||
|
:L KG +2500000+00
|
|||
|
:T FD 184
|
|||
|
:
|
|||
|
:JU -FB 8 COUNT PULSE
|
|||
|
Name :COUNTER
|
|||
|
STRT : F 200.0 measure on discharge
|
|||
|
RSET : -M 61.0 RESET ALL BLTIME
|
|||
|
AKTI : F 203.4
|
|||
|
AUSG : F 203.5
|
|||
|
SOLL : FD 180
|
|||
|
IST : DD 46
|
|||
|
IMP : -E 21.3=z10+b3.BD560-rot
|
|||
|
H-IM : -M 63.5 H-IMP DISC BD560
|
|||
|
EINH : FD 184
|
|||
|
:
|
|||
|
:L FW 202
|
|||
|
:T DW 40
|
|||
|
:***
|
|||
|
|
|||
|
F 61.0 = M 61.0 RESET ALL BLTIME
|
|||
|
I 21.3 = E 21.3=z10+b3.BD560-rot rotation impulse BD 560
|
|||
|
F 63.5 = M 63.5 H-IMP DISC BD560
|
|||
|
|
|||
|
FB 8 = FB 8 COUNT PULSE
|
|||
|
|
|||
|
Segment 59 run/cycle blender BD560 charge ?
|
|||
|
:L DW 25
|
|||
|
:L KF +0
|
|||
|
:!=F
|
|||
|
:= -M 63.6 BD560 NO RUN CHA
|
|||
|
:
|
|||
|
:L DW 26
|
|||
|
:L KF +0
|
|||
|
:!=F
|
|||
|
:= -M 63.0 BD560 NO CYCL CH
|
|||
|
:***
|
|||
|
|
|||
|
F 63.6 = M 63.6 BD560 NO RUN CHA
|
|||
|
F 63.0 = M 63.0 BD560 NO CYCL CH
|
|||
|
|
|||
|
Segment 60 prep.time imp/pause BD560 charge
|
|||
|
:L DW 25
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 27
|
|||
|
:L KF +10
|
|||
|
:>F
|
|||
|
:O -M 63.6 BD560 NO RUN CHA
|
|||
|
:JC =M001
|
|||
|
:T DW 25
|
|||
|
M001 :
|
|||
|
:L DW 26
|
|||
|
:L KF +10
|
|||
|
:>F
|
|||
|
:O -M 63.0 BD560 NO CYCL CH
|
|||
|
:JC =M002
|
|||
|
:T DW 26
|
|||
|
M002 :***
|
|||
|
|
|||
|
F 63.6 = M 63.6 BD560 NO RUN CHA
|
|||
|
F 63.0 = M 63.0 BD560 NO CYCL CH
|
|||
|
|
|||
|
Segment 61 run/cycl blender BD560 discharge
|
|||
|
:L DW 23
|
|||
|
:L KF +0
|
|||
|
:!=F
|
|||
|
:= -M 63.7 BD560 NO RUN DIS
|
|||
|
:
|
|||
|
:L DW 24
|
|||
|
:L KF +0
|
|||
|
:!=F
|
|||
|
:= -M 63.1 BD560 NO CYCL DI
|
|||
|
:***
|
|||
|
|
|||
|
F 63.7 = M 63.7 BD560 NO RUN DIS
|
|||
|
F 63.1 = M 63.1 BD560 NO CYCL DI
|
|||
|
|
|||
|
Segment 62 prep.t imp/pause BD560 discharge
|
|||
|
:L DW 23
|
|||
|
:L KF +10
|
|||
|
:>F
|
|||
|
:O -M 63.7 BD560 NO RUN DIS
|
|||
|
:JC =M001
|
|||
|
:T DW 23
|
|||
|
M001 :
|
|||
|
:L DW 24
|
|||
|
:L KF +10
|
|||
|
:>F
|
|||
|
:O -M 63.1 BD560 NO CYCL DI
|
|||
|
:JC =M002
|
|||
|
:T DW 24
|
|||
|
M002 :***
|
|||
|
|
|||
|
F 63.7 = M 63.7 BD560 NO RUN DIS
|
|||
|
F 63.1 = M 63.1 BD560 NO CYCL DI
|
|||
|
|
|||
|
Segment 63 prepare imp/pause blender
|
|||
|
:AN -M 62.0 BD560-STRT DISCH
|
|||
|
:L DW 25
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L DW 23
|
|||
|
M001 :T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:AN -M 62.0 BD560-STRT DISCH
|
|||
|
:L DW 26
|
|||
|
:JC =M002
|
|||
|
:
|
|||
|
:L DW 24
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 28
|
|||
|
M002 :T -MW182 PARAMETER 2
|
|||
|
:***
|
|||
|
|
|||
|
F 62.0 = M 62.0 BD560-STRT DISCH
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
|
|||
|
Segment 64 prepare time clock blender
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : -MW180 PARAMETER 1
|
|||
|
AUSG : FW 202
|
|||
|
:
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : -MW182 PARAMETER 2
|
|||
|
AUSG : FW 204
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 65 release clock blender
|
|||
|
:A -M 62.6 BD560 AUTO-MODE
|
|||
|
:A -M 62.0 BD560-STRT DISCH
|
|||
|
:AN -M 62.1 STRT DINOP BD560
|
|||
|
:AN -M 63.1 BD560 NO CYCL DI
|
|||
|
:AN -M 63.7 BD560 NO RUN DIS
|
|||
|
:AN -S 10.0=z10+b3.BD560-rbl
|
|||
|
:O(
|
|||
|
:A -M 62.6 BD560 AUTO-MODE 01
|
|||
|
:A -M 61.4 BD560-STRT CHARG 01
|
|||
|
:AN -M 63.0 BD560 NO CYCL CH 01
|
|||
|
:AN -M 63.6 BD560 NO RUN CHA 01
|
|||
|
:AN -S 10.0=z10+b3.BD560-rbl 01
|
|||
|
:) 01
|
|||
|
:= F 200.0 release
|
|||
|
:***
|
|||
|
|
|||
|
F 62.6 = M 62.6 BD560 AUTO-MODE
|
|||
|
F 62.0 = M 62.0 BD560-STRT DISCH
|
|||
|
F 62.1 = M 62.1 STRT DINOP BD560
|
|||
|
F 63.1 = M 63.1 BD560 NO CYCL DI
|
|||
|
F 63.7 = M 63.7 BD560 NO RUN DIS
|
|||
|
S 10.0 = S 10.0=z10+b3.BD560-rbl ribbon blender on BD 560
|
|||
|
F 61.4 = M 61.4 BD560-STRT CHARG
|
|||
|
F 63.0 = M 63.0 BD560 NO CYCL CH
|
|||
|
F 63.6 = M 63.6 BD560 NO RUN CHA
|
|||
|
|
|||
|
Segment 66 Clock blender
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : F 200.0
|
|||
|
T : -T89 BD560 cyc blender
|
|||
|
DWIM : FW 202
|
|||
|
DWPA : FW 204
|
|||
|
AUSG : -M 61.6 BD560-CYCL DI/CH
|
|||
|
POS : -M 0.2 CONSTANT 0
|
|||
|
DBT : -DB30 BD560 BLENDER
|
|||
|
RM : -M 61.6 BD560-CYCL DI/CH
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 29
|
|||
|
T-IN : FW 206
|
|||
|
IN : KS
|
|||
|
SOLL : KF +0
|
|||
|
IST : FW 208
|
|||
|
FERT : F 200.1
|
|||
|
BITL : FW 210
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB30 BD560 BLENDER
|
|||
|
:***
|
|||
|
|
|||
|
T 89 = T89 BD560 cyc blender BD560 cycle blender
|
|||
|
F 61.6 = M 61.6 BD560-CYCL DI/CH
|
|||
|
F 0.2 = M 0.2 CONSTANT 0
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
|
|||
|
DB 30 = DB30 BD560 BLENDER
|
|||
|
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 67 Blender motor on
|
|||
|
:A -M 63.0 BD560 NO CYCL CH
|
|||
|
:AN -M 63.6 BD560 NO RUN CHA
|
|||
|
:O -M 62.7 BD560 MANUAL-MOD
|
|||
|
:A -M 61.4 BD560-STRT CHARG
|
|||
|
:O -M 61.7 BD560-STRT BLEND
|
|||
|
:O(
|
|||
|
:A -M 63.1 BD560 NO CYCL DI 01
|
|||
|
:AN -M 63.7 BD560 NO RUN DIS 01
|
|||
|
:O -M 62.7 BD560 MANUAL-MOD 01
|
|||
|
:O -M 62.1 STRT DINOP BD560 01
|
|||
|
:A -M 62.0 BD560-STRT DISCH 01
|
|||
|
:) 01
|
|||
|
:O -M 61.6 BD560-CYCL DI/CH
|
|||
|
:A -E 21.4=z10+b3.BD560-lid
|
|||
|
: *UN A20.0 lock blender NOT exist
|
|||
|
:AN -S 10.0=z10+b3.BD560-rbl
|
|||
|
:AN -M 62.4 BD560 OFF CHK EM
|
|||
|
:= F 200.0 *(5) start blender
|
|||
|
:***
|
|||
|
|
|||
|
F 63.0 = M 63.0 BD560 NO CYCL CH
|
|||
|
F 63.6 = M 63.6 BD560 NO RUN CHA
|
|||
|
F 62.7 = M 62.7 BD560 MANUAL-MOD
|
|||
|
F 61.4 = M 61.4 BD560-STRT CHARG
|
|||
|
F 61.7 = M 61.7 BD560-STRT BLEND
|
|||
|
F 63.1 = M 63.1 BD560 NO CYCL DI
|
|||
|
F 63.7 = M 63.7 BD560 NO RUN DIS
|
|||
|
F 62.1 = M 62.1 STRT DINOP BD560
|
|||
|
F 62.0 = M 62.0 BD560-STRT DISCH
|
|||
|
F 61.6 = M 61.6 BD560-CYCL DI/CH
|
|||
|
I 21.4 = E 21.4=z10+b3.BD560-lid lid closed BD 560
|
|||
|
S 10.0 = S 10.0=z10+b3.BD560-rbl ribbon blender on BD 560
|
|||
|
F 62.4 = M 62.4 BD560 OFF CHK EM
|
|||
|
|
|||
|
Segment 68 release frequ.convert.BD560 *(5)
|
|||
|
: *(6) No start blender
|
|||
|
:A -A 10.0=z10+b3.BD560-rbl *(5) Total network inserted!
|
|||
|
:A -E 10.0=z10+b3.BD560-rbl
|
|||
|
:A -E 10.1=z10+b3.BD560-fco
|
|||
|
:AN -S 10.1=z10+b3.BD560-fco
|
|||
|
:L KT 005.2
|
|||
|
:SD -T94 BD560 delay freq.co
|
|||
|
:
|
|||
|
:A -T94 BD560 delay freq.co
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 30
|
|||
|
:A F 200.0 *(6) start blender
|
|||
|
:= -A 10.1=z10+b3.BD560-fco
|
|||
|
:
|
|||
|
:AN -A 10.1=z10+b3.BD560-fco
|
|||
|
:L KF +0
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L DW 67 Automode: set speed of BD560 in%
|
|||
|
M001 :T -MW182 PARAMETER 2
|
|||
|
:***
|
|||
|
|
|||
|
Q 10.0 = A 10.0=z10+b3.BD560-rbl ribbon blender on BD 560
|
|||
|
I 10.0 = E 10.0=z10+b3.BD560-rbl ribbon blender on BD 560
|
|||
|
I 10.1 = E 10.1=z10+b3.BD560-fco frequ.converter ready BD 560 *(5)
|
|||
|
S 10.1 = S 10.1=z10+b3.BD560-fco frequ.converter ready BD 560 *(5)
|
|||
|
T 94 = T94 BD560 delay freq.co BD560 delay freq.converter *(5)
|
|||
|
Q 10.1 = A 10.1=z10+b3.BD560-fco frequ.converter release BD 560 *(5)
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
|
|||
|
Segment 69 set value freq.conv. BD560 *(5)
|
|||
|
:L KF +136 *(5) Total network inserted!
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB251 WRIT ANALOG VALUE
|
|||
|
Name :AN-AUS
|
|||
|
APW : -MW180 PARAMETER 1
|
|||
|
OG : KG +1000000+04
|
|||
|
UG : KG +0000000+00
|
|||
|
AMAX : KF +1024
|
|||
|
AMIN : KF +0
|
|||
|
WERG : FD 192
|
|||
|
WERT : -MW182 PARAMETER 2
|
|||
|
G/F : KS F
|
|||
|
IN : KS IN
|
|||
|
FORM : KS ..
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
|
|||
|
FB 251 = FB251 WRIT ANALOG VALUE
|
|||
|
|
|||
|
Segment 70 air purged seals BD560 *(5)
|
|||
|
:O -M 60.1 CHARGE ACT.BD560 *(5) Total network inserted!
|
|||
|
:O -M 61.7 BD560-STRT BLEND
|
|||
|
:O -M 66.1 BD560 STR ON DIS
|
|||
|
:= -A 20.1=z10+b3.BD560-aps
|
|||
|
:= -A 20.2=z10+b3.BD560-aps
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T FY 180 0= P-address
|
|||
|
:L KF +140
|
|||
|
:T FY 181 PW140
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T FY 182 0= P-address
|
|||
|
:L KF +142
|
|||
|
:T FY 183 PW142
|
|||
|
:***
|
|||
|
|
|||
|
F 60.1 = M 60.1 CHARGE ACT.BD560
|
|||
|
F 61.7 = M 61.7 BD560-STRT BLEND
|
|||
|
F 66.1 = M 66.1 BD560 STR ON DIS *(5)
|
|||
|
Q 20.1 = A 20.1=z10+b3.BD560-aps air purged seals 1 on BD 560 *(5)
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 31
|
|||
|
Q 20.2 = A 20.2=z10+b3.BD560-aps air purged seals 2 on BD 560 *(5)
|
|||
|
|
|||
|
Segment 71 pressure transmitter seal 1 *(5)
|
|||
|
:L DW 53 calibrate pressure seal 1
|
|||
|
:L KF +0 *(5) Total network inserted!
|
|||
|
:><F
|
|||
|
:O -A 20.1=z10+b3.BD560-aps
|
|||
|
:= -M 65.0 PRESS1 ACT BD560
|
|||
|
:
|
|||
|
:JU -FB118 PRESSURE TRANSMIT
|
|||
|
Name :DRUCKAUF
|
|||
|
BGRN : -MW180 PARAMETER 1 0= P-address, PW140
|
|||
|
OG : DW 55 pr. range max limit seal 1 BD560
|
|||
|
UG : DW 54 pr. range min limit seal 1 BD560
|
|||
|
AUSG : DW 56 relative pressure seal 1 BD560
|
|||
|
FEHL : F 200.0
|
|||
|
AKTV : -M 65.0 PRESS1 ACT BD560
|
|||
|
TIMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
S5S7 : KS S5
|
|||
|
:L DW 56 *(6) rel. pressure seal 1 BD560
|
|||
|
:L DW 54 *(6) pr.range min li.seal1 BD560
|
|||
|
:<F *(6)
|
|||
|
:JC =M001 *(6)
|
|||
|
:L DW 56 *(6) rel. pressure seal 1 BD560
|
|||
|
:L DW 55 *(6) pr.range max li.seal1 BD560
|
|||
|
:>F *(6)
|
|||
|
:JC =M001 *(6)
|
|||
|
:JU =M002 *(6)
|
|||
|
M001 :L KF -1 *(6) val.out of range: displ. -1
|
|||
|
:T DW 56 *(6) rel. pressure seal 1 BD560
|
|||
|
M002 :*** *(6)
|
|||
|
|
|||
|
Q 20.1 = A 20.1=z10+b3.BD560-aps air purged seals 1 on BD 560 *(5)
|
|||
|
F 65.0 = M 65.0 PRESS1 ACT BD560 *(5)
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 118 = FB118 PRESSURE TRANSMIT hkt as
|
|||
|
|
|||
|
Segment 72 pressure transmitter seal 2 *(5)
|
|||
|
:L DW 58 calibrate pressure seal 2
|
|||
|
:L KF +0 *(5) Total network inserted!
|
|||
|
:><F
|
|||
|
:O -A 20.2=z10+b3.BD560-aps
|
|||
|
:= -M 65.1 PRESS2 ACT BD560
|
|||
|
:
|
|||
|
:JU -FB118 PRESSURE TRANSMIT
|
|||
|
Name :DRUCKAUF
|
|||
|
BGRN : -MW182 PARAMETER 2 0= P-address, PW142
|
|||
|
OG : DW 60 pr. range max limit seal 2 BD560
|
|||
|
UG : DW 59 pr. range min limit seal 2 BD560
|
|||
|
AUSG : DW 61 relative pressure seal 2 BD560
|
|||
|
FEHL : F 200.1
|
|||
|
AKTV : -M 65.1 PRESS2 ACT BD560
|
|||
|
TIMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
S5S7 : KS S5
|
|||
|
:L DW 61 *(6) rel. pressure seal 2 BD560
|
|||
|
:L DW 59 *(6) pr.range min li.seal2 BD560
|
|||
|
:<F *(6)
|
|||
|
:JC =M001 *(6)
|
|||
|
:L DW 61 *(6) rel. pressure seal 2 BD560
|
|||
|
:L DW 60 *(6) pr.range max li.seal2 BD560
|
|||
|
:>F *(6)
|
|||
|
:JC =M001 *(6)
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 32
|
|||
|
:JU =M002 *(6)
|
|||
|
M001 :L KF -1 *(6) val.out of range: displ. -1
|
|||
|
:T DW 61 *(6) rel. pressure seal 2 BD560
|
|||
|
M002 :*** *(6)
|
|||
|
|
|||
|
Q 20.2 = A 20.2=z10+b3.BD560-aps air purged seals 2 on BD 560 *(5)
|
|||
|
F 65.1 = M 65.1 PRESS2 ACT BD560 *(5)
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 118 = FB118 PRESSURE TRANSMIT hkt as
|
|||
|
|
|||
|
Segment 73 pressure low seal 1+2 BD560 *(5)
|
|||
|
:L DW 56 actual pressure seal 1
|
|||
|
:L DW 57 min pressure seal 1
|
|||
|
:<F *(5) Total network inserted!
|
|||
|
:O F 200.0
|
|||
|
:A -A 20.1=z10+b3.BD560-aps
|
|||
|
:= -M 66.2 PRESS1 LOW BD560
|
|||
|
:
|
|||
|
:L DW 61 actual pressure seal 2
|
|||
|
:L DW 62 min pressure seal 2
|
|||
|
:<F
|
|||
|
:O F 200.1
|
|||
|
:A -A 20.2=z10+b3.BD560-aps
|
|||
|
:= -M 66.3 PRESS2 LOW BD560
|
|||
|
:***
|
|||
|
|
|||
|
Q 20.1 = A 20.1=z10+b3.BD560-aps air purged seals 1 on BD 560 *(5)
|
|||
|
F 66.2 = M 66.2 PRESS1 LOW BD560 *(5)
|
|||
|
Q 20.2 = A 20.2=z10+b3.BD560-aps air purged seals 2 on BD 560 *(5)
|
|||
|
F 66.3 = M 66.3 PRESS2 LOW BD560 *(5)
|
|||
|
|
|||
|
Segment 74 output fault pressure seal1 *(5)
|
|||
|
:L DW 40 *(5) Total network inserted!
|
|||
|
:T FW 202
|
|||
|
:
|
|||
|
:L KF +5
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB108 TIMER IMITATION
|
|||
|
Name :TIMER
|
|||
|
STRT : -M 66.2 PRESS1 LOW BD560
|
|||
|
RSET : -M 0.2 CONSTANT 0
|
|||
|
AKTI : F 203.1
|
|||
|
AUSG : -M 40.3 BD560 PR.F SEAL1
|
|||
|
TTYP : KS SE
|
|||
|
SOLL : -MW180 PARAMETER 1
|
|||
|
IST : DW 38
|
|||
|
IMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 66.2 = M 66.2 PRESS1 LOW BD560 *(5)
|
|||
|
F 0.2 = M 0.2 CONSTANT 0
|
|||
|
F 40.3 = M 40.3 BD560 PR.F SEAL1
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 108 = FB108 TIMER IMITATION e.g. for scale control WK al
|
|||
|
|
|||
|
Segment 75 output fault pressure seal2 *(5)
|
|||
|
:JU -FB108 TIMER IMITATION *(5) Total network inserted!
|
|||
|
Name :TIMER
|
|||
|
STRT : -M 66.3 PRESS2 LOW BD560
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 33
|
|||
|
RSET : -M 0.2 CONSTANT 0
|
|||
|
AKTI : F 203.2
|
|||
|
AUSG : -M 40.4 BD560 PR.F SEAL2
|
|||
|
TTYP : KS SE
|
|||
|
SOLL : -MW180 PARAMETER 1
|
|||
|
IST : DW 39
|
|||
|
IMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
:
|
|||
|
:L FW 202
|
|||
|
:T DW 40
|
|||
|
:***
|
|||
|
|
|||
|
F 66.3 = M 66.3 PRESS2 LOW BD560 *(5)
|
|||
|
F 0.2 = M 0.2 CONSTANT 0
|
|||
|
F 40.4 = M 40.4 BD560 PR.F SEAL2
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 108 = FB108 TIMER IMITATION e.g. for scale control WK al
|
|||
|
|
|||
|
Segment 76 seals ok BD560 *(5)
|
|||
|
:JU -FB106 TRANSFER KF->KT *(6)
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 27
|
|||
|
AUSG : FW 204
|
|||
|
:
|
|||
|
:A -A 20.1=z10+b3.BD560-aps *(5) Total network inserted!
|
|||
|
:A -A 20.2=z10+b3.BD560-aps
|
|||
|
:A -E 21.5=z10+b3.BD560-flm
|
|||
|
:AN -S 21.5=z10+b3.BD560-flm
|
|||
|
:A -E 21.7=z10+b3.BD560-flm
|
|||
|
:AN -S 21.7=z10+b3.BD560-flm
|
|||
|
:AN -M 66.2 PRESS1 LOW BD560
|
|||
|
:AN -S 2.3 PRES1 FAULT BD560 *(6)
|
|||
|
:AN -M 66.3 PRESS2 LOW BD560
|
|||
|
:AN -S 2.4 PRES2 FAULT BD560 *(6)
|
|||
|
:L FW 204 *(6)
|
|||
|
:SD -T93 BD560 ctrl-tim seal
|
|||
|
:
|
|||
|
:A -T93 BD560 ctrl-tim seal
|
|||
|
:S -M 66.0 BD560 SEALS OK
|
|||
|
:
|
|||
|
:AN -A 20.1=z10+b3.BD560-aps
|
|||
|
:AN -A 20.2=z10+b3.BD560-aps
|
|||
|
:R -M 66.0 BD560 SEALS OK
|
|||
|
:***
|
|||
|
|
|||
|
Q 20.1 = A 20.1=z10+b3.BD560-aps air purged seals 1 on BD 560 *(5)
|
|||
|
Q 20.2 = A 20.2=z10+b3.BD560-aps air purged seals 2 on BD 560 *(5)
|
|||
|
I 21.5 = E 21.5=z10+b3.BD560-flm flowmeter 1 healthy BD 560 *(5)
|
|||
|
S 21.5 = S 21.5=z10+b3.BD560-flm flowmeter 1 healthy BD560 *(5)
|
|||
|
I 21.7 = E 21.7=z10+b3.BD560-flm flowmeter 2 healthy BD 560 *(5)
|
|||
|
S 21.7 = S 21.7=z10+b3.BD560-flm flowmeter 2 healthy BD560 *(5)
|
|||
|
F 66.2 = M 66.2 PRESS1 LOW BD560 *(5)
|
|||
|
S 2.3 = S 2.3 PRES1 FAULT BD560 *(6)
|
|||
|
F 66.3 = M 66.3 PRESS2 LOW BD560 *(5)
|
|||
|
S 2.4 = S 2.4 PRES2 FAULT BD560 *(6)
|
|||
|
T 93 = T93 BD560 ctrl-tim seal BD560 control time seals ok *(5)
|
|||
|
F 66.0 = M 66.0 BD560 SEALS OK *(5)
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 77 motor contactor BD560 *(5)
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 34
|
|||
|
:A -A 12.7=z10+b3.HO584-anv *(5) Total network inserted!
|
|||
|
:A -E 12.7=z10+b3.HO584-anv
|
|||
|
:AN -S 12.7=z10+b3.HO584-anv
|
|||
|
:AN -S 16.7=z10+b3.HO584-anv
|
|||
|
:O
|
|||
|
:A -A 13.0=z10+b3.HO584-anv
|
|||
|
:A -E 13.0=z10+b3.HO584-anv
|
|||
|
:AN -S 13.0=z10+b3.HO584-anv
|
|||
|
:AN -S 17.0=z10+b3.HO584-anv
|
|||
|
:O -M 66.1 BD560 STR ON DIS
|
|||
|
:O -M 61.7 BD560-STRT BLEND
|
|||
|
:A -M 66.0 BD560 SEALS OK
|
|||
|
:L KT 005.2
|
|||
|
:SF -T95 BD560 OFF-delay mot
|
|||
|
:***
|
|||
|
|
|||
|
Q 12.7 = A 12.7=z10+b3.HO584-anv angle valve 1O2I 563 open HO 584
|
|||
|
I 12.7 = E 12.7=z10+b3.HO584-anv angle valve 1O2I 563 open HO 584
|
|||
|
S 12.7 = S 12.7=z10+b3.HO584-anv angle valve 1O2I 563 open HO 584
|
|||
|
S 16.7 = S 16.7=z10+b3.HO584-anv angle valve 1O2I 563 closed HO 584
|
|||
|
Q 13.0 = A 13.0=z10+b3.HO584-anv angle valve 1O2I 583 open HO 584
|
|||
|
I 13.0 = E 13.0=z10+b3.HO584-anv angle valve 1O2I 583 open HO 584
|
|||
|
S 13.0 = S 13.0=z10+b3.HO584-anv angle valve 1O2I 583 open HO 584
|
|||
|
S 17.0 = S 17.0=z10+b3.HO584-anv angle valve 1O2I 583 closed HO 584
|
|||
|
F 66.1 = M 66.1 BD560 STR ON DIS *(5)
|
|||
|
F 61.7 = M 61.7 BD560-STRT BLEND
|
|||
|
F 66.0 = M 66.0 BD560 SEALS OK *(5)
|
|||
|
T 95 = T95 BD560 OFF-delay mot BD560 OFF-delay motor contactor *(5)
|
|||
|
|
|||
|
Segment 78 motor contactor BD560 *(5)
|
|||
|
:A -T95 BD560 OFF-delay mot *(5) Total network inserted!
|
|||
|
:A -E 10.2=z10+b3.BD560-sac *(6)
|
|||
|
:AN -S 10.2=z10+b3.BD560-sac *(6)
|
|||
|
:AN -S 10.0=z10+b3.BD560-rbl
|
|||
|
:A -E 21.4=z10+b3.BD560-lid
|
|||
|
:AN -M 62.4 BD560 OFF CHK EM
|
|||
|
:= -A 10.0=z10+b3.BD560-rbl
|
|||
|
:***
|
|||
|
|
|||
|
T 95 = T95 BD560 OFF-delay mot BD560 OFF-delay motor contactor *(5)
|
|||
|
I 10.2 = E 10.2=z10+b3.BD560-sac safety circuit all healthy BD 560 *(6)
|
|||
|
S 10.2 = S 10.2=z10+b3.BD560-sac safety circuit all healthy BD 560 *(6)
|
|||
|
S 10.0 = S 10.0=z10+b3.BD560-rbl ribbon blender on BD 560
|
|||
|
I 21.4 = E 21.4=z10+b3.BD560-lid lid closed BD 560
|
|||
|
F 62.4 = M 62.4 BD560 OFF CHK EM
|
|||
|
Q 10.0 = A 10.0=z10+b3.BD560-rbl ribbon blender on BD 560
|
|||
|
|
|||
|
Segment 79 actual val. freq.conv.MI583 *(5)
|
|||
|
:L KF +0 *(5) Total network inserted!
|
|||
|
:T FY 180 0= P-address
|
|||
|
:L KF +130
|
|||
|
:T FY 181
|
|||
|
:L KF +1500 *(6)
|
|||
|
:T -MW182 PARAMETER 2 Max= 1500
|
|||
|
:L KF +0
|
|||
|
:T -MW184 PARAMETER 3 Min= 0
|
|||
|
:
|
|||
|
:JU -FB118 PRESSURE TRANSMIT
|
|||
|
Name :DRUCKAUF
|
|||
|
BGRN : -MW180 PARAMETER 1
|
|||
|
OG : -MW182 PARAMETER 2
|
|||
|
UG : -MW184 PARAMETER 3
|
|||
|
AUSG : DW 63 act.speed cone mill MI583 in rpm
|
|||
|
FEHL : F 200.0
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 35
|
|||
|
AKTV : -M 0.1 CONSTANT 1
|
|||
|
TIMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
S5S7 : KS S5
|
|||
|
:***
|
|||
|
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 118 = FB118 PRESSURE TRANSMIT hkt as
|
|||
|
|
|||
|
Segment 80 value out of range MI583 *(5)
|
|||
|
:L DW 63 act.speed cone mill MI583 in rpm
|
|||
|
:L -MW184 PARAMETER 3 Min speed cone mill MI583 in rpm
|
|||
|
:<F *(5) Total network inserted !
|
|||
|
:JC =M001
|
|||
|
:L DW 63 act.speed cone mill MI583 in rpm
|
|||
|
:L -MW182 PARAMETER 2 Max speed cone mill MI583 in rpm
|
|||
|
:>F
|
|||
|
:JC =M001
|
|||
|
:JU =M002
|
|||
|
M001 :L KF -1 value out of range: displ.-1 rpm
|
|||
|
:T DW 63 act.speed cone mill MI583 in rpm
|
|||
|
M002 :***
|
|||
|
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
|
|||
|
Segment 81 speed out of tol.range MI583*(5)
|
|||
|
:L DW 71 ctrl-speed con.mill MI583 in rpm
|
|||
|
:L DW 64 speed tol.cone mill MI583 in rpm
|
|||
|
:-F
|
|||
|
:L DW 63 act.speed cone mill MI583 in rpm
|
|||
|
:>F act speed < set speed - tol
|
|||
|
:= F 201.0
|
|||
|
: *(5) Total network inserted
|
|||
|
:L DW 71 ctrl-speed con.mill MI583 in rpm
|
|||
|
:L DW 64 speed tol.cone mill MI583 in rpm
|
|||
|
:+F
|
|||
|
:L DW 63 act.speed cone mill MI583 in rpm
|
|||
|
:<F act speed > set speed + tol
|
|||
|
:O F 201.0 act speed < set speed - tol
|
|||
|
:O F 200.0
|
|||
|
:A -A 8.7=z10+b3.MI583-fco
|
|||
|
:L KT 080.1
|
|||
|
:SD T 202
|
|||
|
:A T 202
|
|||
|
:= -M 66.4 SPEED NOK MI583
|
|||
|
:***
|
|||
|
|
|||
|
Q 8.7 = A 8.7=z10+b3.MI583-fco frequ.converter MI release MI 583
|
|||
|
F 66.4 = M 66.4 SPEED NOK MI583 *(5)
|
|||
|
|
|||
|
Segment 82 actual val. freq.conv.BD560 *(5)
|
|||
|
:L KF +0 *(5) Total network inserted!
|
|||
|
:T FY 180 0= P-address
|
|||
|
:L KF +136
|
|||
|
:T FY 181
|
|||
|
:
|
|||
|
:JU -FB118 PRESSURE TRANSMIT
|
|||
|
Name :DRUCKAUF
|
|||
|
BGRN : -MW180 PARAMETER 1
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 36
|
|||
|
OG : DW 70 Max speed blender BD560 in rpm
|
|||
|
UG : DW 69 Min speed blender BD560 in rpm
|
|||
|
AUSG : DW 65 act. speed blender BD560 in rpm
|
|||
|
FEHL : F 200.0
|
|||
|
AKTV : -M 0.1 CONSTANT 1
|
|||
|
TIMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
S5S7 : KS S5
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 118 = FB118 PRESSURE TRANSMIT hkt as
|
|||
|
|
|||
|
Segment 83 value out of range BD560 *(5)
|
|||
|
:L DW 65 act. speed blender BD560 in rpm
|
|||
|
:L DW 69 Min speed blender BD560 in rpm
|
|||
|
:<F *(5) Total network inserted !
|
|||
|
:JC =M001
|
|||
|
:L DW 65 act. speed blender BD560 in rpm
|
|||
|
:L DW 70 Max speed blender BD560 in rpm
|
|||
|
:>F
|
|||
|
:JC =M001
|
|||
|
:JU =M002
|
|||
|
M001 :L KF -1 value out of range: displ.-1 rpm
|
|||
|
:T DW 65 act. speed blender BD560 in rpm
|
|||
|
M002 :***
|
|||
|
|
|||
|
|
|||
|
Segment 84 speed out of tol.range BD560*(5)
|
|||
|
:L DW 68 ctrl-speed blender BD560 in rpm
|
|||
|
:L DW 66 speed tol. blender BD560 in rpm
|
|||
|
:-F
|
|||
|
:L DW 65 act. speed blender BD560 in rpm
|
|||
|
:>F act speed < set speed - tol
|
|||
|
:= F 201.0
|
|||
|
: *(5) Total network inserted
|
|||
|
:L DW 68 ctrl-speed blender BD560 in rpm
|
|||
|
:L DW 66 speed tol. blender BD560 in rpm
|
|||
|
:+F
|
|||
|
:L DW 65 act. speed blender BD560 in rpm
|
|||
|
:<F act speed > set speed + tol
|
|||
|
:O F 201.0 act speed < set speed - tol
|
|||
|
:O F 200.0
|
|||
|
:A -A 10.1=z10+b3.BD560-fco
|
|||
|
:L KT 080.1
|
|||
|
:SD T 201
|
|||
|
:A T 201
|
|||
|
:= -M 66.5 SPEED NOK BD560
|
|||
|
:***
|
|||
|
|
|||
|
Q 10.1 = A 10.1=z10+b3.BD560-fco frequ.converter release BD 560 *(5)
|
|||
|
F 66.5 = M 66.5 SPEED NOK BD560 *(5)
|
|||
|
|
|||
|
Segment 85 output fault MI speed MI583 *(5)
|
|||
|
:L DW 40 *(5) Total network inserted!
|
|||
|
:T FW 202
|
|||
|
:
|
|||
|
:L KF +5
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB108 TIMER IMITATION
|
|||
|
Name :TIMER
|
|||
|
FB 30 -FB30 BLENDER BD560 C:ZONE10ST.S5D LEN=1688
|
|||
|
Page 37
|
|||
|
STRT : -M 66.4 SPEED NOK MI583
|
|||
|
RSET : -M 0.2 CONSTANT 0
|
|||
|
AKTI : F 203.3
|
|||
|
AUSG : -M 40.5 MI583 SPEED FAUL
|
|||
|
TTYP : KS SE
|
|||
|
SOLL : -MW180 PARAMETER 1
|
|||
|
IST : DW 33
|
|||
|
IMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 66.4 = M 66.4 SPEED NOK MI583 *(5)
|
|||
|
F 0.2 = M 0.2 CONSTANT 0
|
|||
|
F 40.5 = M 40.5 MI583 SPEED FAUL
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 108 = FB108 TIMER IMITATION e.g. for scale control WK al
|
|||
|
|
|||
|
Segment 86 output fault speed BD560 *(5)
|
|||
|
:JU -FB108 TIMER IMITATION *(5) Total network inserted!
|
|||
|
Name :TIMER
|
|||
|
STRT : -M 66.5 SPEED NOK BD560
|
|||
|
RSET : -M 0.2 CONSTANT 0
|
|||
|
AKTI : F 203.4
|
|||
|
AUSG : -M 40.6 BD560 SPEED FAUL
|
|||
|
TTYP : KS SE
|
|||
|
SOLL : -MW180 PARAMETER 1
|
|||
|
IST : DW 34
|
|||
|
IMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
:
|
|||
|
:L FW 202
|
|||
|
:T DW 40
|
|||
|
:BE
|
|||
|
|
|||
|
F 66.5 = M 66.5 SPEED NOK BD560 *(5)
|
|||
|
F 0.2 = M 0.2 CONSTANT 0
|
|||
|
F 40.6 = M 40.6 BD560 SPEED FAUL
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 108 = FB108 TIMER IMITATION e.g. for scale control WK al
|
|||
|
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
******************************************************************************
|
|||
|
|
|||
|
DESCRIPTION :
|
|||
|
|
|||
|
This block handels the control weighing from dryer to scale HO560
|
|||
|
and the discharge of this scale to the hammer mill.
|
|||
|
|
|||
|
|
|||
|
|
|||
|
******************************************************************************
|
|||
|
|
|||
|
|
|||
|
PARAMETER :
|
|||
|
|
|||
|
|
|||
|
LINR : line number
|
|||
|
WANR : scale number
|
|||
|
WZNR : scale count number ( to calculate the data blocks )
|
|||
|
T1 : Timer 1 ( reserve )
|
|||
|
T2 : Timer 2 ( time until conveying pressure built up )
|
|||
|
T3 : Timer 3 ( cycle purged air filter )
|
|||
|
T4 : Timer 4 ( reserve )
|
|||
|
T5 : Timer 5 ( cycle vibration motor )
|
|||
|
T6 : Timer 6 ( reserve )
|
|||
|
T7 : Timer 7 ( reserve )
|
|||
|
T8 : Timer 8 ( TTOL FB92 )
|
|||
|
T9 : Timer 9 ( TFIN FB92 )
|
|||
|
T10 : Timer 10 ( )
|
|||
|
AF/J : lifting funct. J/N ( scale discharge with lifting function is
|
|||
|
selected , if this parameter is set to J )
|
|||
|
PWDT : analog input pressure transmiter
|
|||
|
PWFU : analog output frequency converter
|
|||
|
CPSI : charge phase step index
|
|||
|
ECSI : end of charge step
|
|||
|
DPSI : discharge phase step index
|
|||
|
EDSI : end of discharge step
|
|||
|
EMPY : empty check ( MIN<x<MAX )
|
|||
|
|
|||
|
********************************************************************************
|
|||
|
|
|||
|
INTERNAL USED BLOCKS :
|
|||
|
|
|||
|
FB 190 Scale module
|
|||
|
FB 91 Occupy silo
|
|||
|
FB 106 Transfer KF->KT
|
|||
|
FB 90 Check multiport valve
|
|||
|
FB 108 Timer imitation
|
|||
|
FB 250 Read analog value
|
|||
|
FB 6 Pressure transmiter
|
|||
|
FB 251 Write analog value
|
|||
|
FB 92 Control weighing
|
|||
|
FB 113 Clock generator
|
|||
|
|
|||
|
*******************************************************************************
|
|||
|
|
|||
|
|
|||
|
Name :WAAGE
|
|||
|
Decl :LINR I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :WANR I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :WZNR I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T1 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T2 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 2
|
|||
|
Decl :T3 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T4 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T5 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T6 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T7 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T8 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T9 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T10 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :AF/J I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KS
|
|||
|
Decl :PWDT I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :PWFU I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :CPSI I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :ECSI I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :DPSI I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :EDSI I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :EMPY I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2 calculate DB-addresses
|
|||
|
:LW =LINR
|
|||
|
:SLW 3 line no.
|
|||
|
:LW =LINR multiplyed 10
|
|||
|
:SLW 1
|
|||
|
:+F
|
|||
|
:T -MW 32 ADDR.LINE_DB = address line-DB
|
|||
|
:
|
|||
|
:LW =WANR line-DB
|
|||
|
:+F + scale no.
|
|||
|
:T -MW 34 ADDR.SCALE_DB = address scale-DB
|
|||
|
:
|
|||
|
:LW =WZNR scale count no.
|
|||
|
:L KF +164 + 164
|
|||
|
:+F = Address DB dosing addresses
|
|||
|
:T -MW 38 ADDR.DOS_ADR_DB
|
|||
|
:***
|
|||
|
|
|||
|
FW 32 = MW 32 ADDR.LINE_DB
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
FW 38 = MW 38 ADDR.DOS_ADR_DB
|
|||
|
|
|||
|
Segment 3 store scale count number
|
|||
|
:DO -MW 34 ADDR.SCALE_DB
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:
|
|||
|
:LW =WZNR
|
|||
|
:T DW 1 hand over scale count number
|
|||
|
:
|
|||
|
:L -MW 34 ADDR.SCALE_DB
|
|||
|
:T DW 4 hand over number working-DB
|
|||
|
:
|
|||
|
:L -MW 38 ADDR.DOS_ADR_DB
|
|||
|
:T DW 5
|
|||
|
:***
|
|||
|
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
FW 38 = MW 38 ADDR.DOS_ADR_DB
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 4 load status of weighing
|
|||
|
:L DW 6
|
|||
|
:T -MW 10 I-CONTROLBITs interface to scale module
|
|||
|
:L DW 7
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 3
|
|||
|
:T -MW 12 I-CONTROLBITs
|
|||
|
:L DW 52
|
|||
|
:T -MW 14 O-CONTROLBITs
|
|||
|
:L DW 53
|
|||
|
:T -MW 16 O-CONTROLBITs
|
|||
|
: --------------------------------
|
|||
|
:L DW 114 internal variable weighing
|
|||
|
:T -MW18 STATUS FLAGS
|
|||
|
: --------------------------------
|
|||
|
:L DW 115 outputs scale
|
|||
|
:T -MW24 IND. OUTPUTS SCALE
|
|||
|
:L DW 117
|
|||
|
:T -MW28 IND. OUTPUTS WAY
|
|||
|
: --------------------------------
|
|||
|
:L DR 119
|
|||
|
:T -MB90 SIGNAL DISPLAY
|
|||
|
:***
|
|||
|
|
|||
|
FW 10 = MW 10 I-CONTROLBITs plc scale EST 1
|
|||
|
FW 12 = MW 12 I-CONTROLBITs plc scale EST 2
|
|||
|
FW 14 = MW 14 O-CONTROLBITs plc scale AST 1
|
|||
|
FW 16 = MW 16 O-CONTROLBITs plc scale AST 2
|
|||
|
FW 18 = MW18 STATUS FLAGS SCALE STATUS
|
|||
|
FW 24 = MW24 IND. OUTPUTS SCALE
|
|||
|
FW 28 = MW28 IND. OUTPUTS WAY
|
|||
|
FY 90 = MB90 SIGNAL DISPLAY SCALE SIGNAL DISPLAY
|
|||
|
|
|||
|
Segment 5 MODE to scale module
|
|||
|
:A -M 0.3 1 SEC. IMPULSE
|
|||
|
:= -ME12.0 1-SEC-IMPULSE
|
|||
|
:
|
|||
|
:AN -M 4.0 GLOBAL AUTO-MODE
|
|||
|
:AN -M 4.1 GLOB. MANUAL-MODE
|
|||
|
:O -M 4.2 GLOB.SERVICE-MODE
|
|||
|
:= -ME12.1 PLC-MODE/PC-MODE
|
|||
|
:***
|
|||
|
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
F 12.0 = ME12.0 1-SEC-IMPULSE plc scale EST 2
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
F 4.2 = M 4.2 GLOB.SERVICE-MODE
|
|||
|
F 12.1 = ME12.1 PLC-MODE/PC-MODE plc scale EST 2 (1=PLC-MODE / 0=PC-MODE)
|
|||
|
|
|||
|
Segment 6 communication scale module
|
|||
|
:JU -FB190 SCALE CONTROL
|
|||
|
Name :WAAGE
|
|||
|
W-NR : DW 1
|
|||
|
EST1 : -MW 10 I-CONTROLBITs
|
|||
|
EST2 : -MW 12 I-CONTROLBITs
|
|||
|
AST1 : -MW 14 O-CONTROLBITs
|
|||
|
AST2 : -MW 16 O-CONTROLBITs
|
|||
|
ANDB : -MW 34 ADDR.SCALE_DB
|
|||
|
DBDX : KS DB
|
|||
|
:***
|
|||
|
|
|||
|
FW 10 = MW 10 I-CONTROLBITs plc scale EST 1
|
|||
|
FW 12 = MW 12 I-CONTROLBITs plc scale EST 2
|
|||
|
FW 14 = MW 14 O-CONTROLBITs plc scale AST 1
|
|||
|
FW 16 = MW 16 O-CONTROLBITs plc scale AST 2
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
|
|||
|
FB 190 = FB190 SCALE CONTROL plc scale
|
|||
|
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 4
|
|||
|
Segment 7 got silo data
|
|||
|
:A -MA16.2 LOAD SILO DATA
|
|||
|
:= -ME10.4 GOT SILO DATA
|
|||
|
:***
|
|||
|
|
|||
|
F 16.2 = MA16.2 LOAD SILO DATA plc scale AST 2
|
|||
|
F 10.4 = ME10.4 GOT SILO DATA plc scale EST 1
|
|||
|
|
|||
|
Segment 8 silo_no. ok
|
|||
|
:L DW 50
|
|||
|
:L KF +1 silo_no. 1,2 ok
|
|||
|
:!=F
|
|||
|
:= F 212.0 silo 1
|
|||
|
:
|
|||
|
:O(
|
|||
|
:L DW 50 01
|
|||
|
:L KF +2 01
|
|||
|
:!=F 01
|
|||
|
:) 01
|
|||
|
:O F 212.0 silo 1
|
|||
|
:= -M 18.0 SILO_NR_OK
|
|||
|
:***
|
|||
|
|
|||
|
F 18.0 = M 18.0 SILO_NR_OK
|
|||
|
|
|||
|
Segment 9 reserve silo with actual scale
|
|||
|
:L KF +0
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB91 OCCUPY_SILO global
|
|||
|
Name :SILO-BEL
|
|||
|
SINR : -MW180 PARAMETER 1
|
|||
|
WADB : -MW 34 ADDR.SCALE_DB working DB
|
|||
|
DOSI : -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
BELG : -M 19.3 LINE_OCCUPIED_OK global occupied
|
|||
|
SIOK : -M 18.0 SILO_NR_OK
|
|||
|
OFFS : KF +30
|
|||
|
SIAW : -MW20 IND. OUTPUTS Silo
|
|||
|
SIEW : -MW22 IND. INPUTs Silo
|
|||
|
:
|
|||
|
:A -M 19.3 LINE_OCCUPIED_OK
|
|||
|
:= -M 18.3 SILO_OCCUPIED_OK
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 19.3 = M 19.3 LINE_OCCUPIED_OK
|
|||
|
F 18.0 = M 18.0 SILO_NR_OK
|
|||
|
FW 20 = MW20 IND. OUTPUTS Silo
|
|||
|
FW 22 = MW22 IND. INPUTs Silo
|
|||
|
F 18.3 = M 18.3 SILO_OCCUPIED_OK
|
|||
|
|
|||
|
FB 91 = FB91 OCCUPY_SILO
|
|||
|
|
|||
|
Segment 10 start vacuum pump
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2 convert heel time
|
|||
|
EING : DW 150
|
|||
|
AUSG : FW 202
|
|||
|
: --------------------------------
|
|||
|
:LW =T1
|
|||
|
:T FW 200
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 5
|
|||
|
:
|
|||
|
:A -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:A -M 18.0 SILO_NR_OK
|
|||
|
:L FW 202 heel time vacuum pump
|
|||
|
:DO FW 200
|
|||
|
:SF -T0 IND.ADDRES.(DUMMY)
|
|||
|
:
|
|||
|
:DO FW 200
|
|||
|
:A -T0 IND.ADDRES.(DUMMY)
|
|||
|
:= -MA24.0 VACUUMPUMP ON
|
|||
|
:***
|
|||
|
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 18.0 = M 18.0 SILO_NR_OK
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
F 24.0 = MA24.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 11 unload valve
|
|||
|
:A -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:A -MA24.0 VACUUMPUMP ON
|
|||
|
:A -ME26.0 VACUUMPUMP ON
|
|||
|
:A -ME27.5 OUTLETFL. CLOSED
|
|||
|
:= F 200.0
|
|||
|
:
|
|||
|
:A F 200.0
|
|||
|
:A -ME27.7 SECUNDARY FIL.OK
|
|||
|
:S -MA24.2 UNLOAD VALVE CON
|
|||
|
:
|
|||
|
:AN F 200.0
|
|||
|
:R -MA24.2 UNLOAD VALVE CON
|
|||
|
:***
|
|||
|
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 24.0 = MA24.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
F 26.0 = ME26.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
F 27.5 = ME27.5 OUTLETFL. CLOSED
|
|||
|
F 27.7 = ME27.7 SECUNDARY FIL.OK
|
|||
|
F 24.2 = MA24.2 UNLOAD VALVE CON
|
|||
|
|
|||
|
Segment 12 Component valve
|
|||
|
:L =CPSI
|
|||
|
:L KF +60 Step 60: cleaning
|
|||
|
:!=F
|
|||
|
:O F 212.0 silo 1
|
|||
|
:A -MA24.2 UNLOAD VALVE CON
|
|||
|
:A -ME26.2 UNLOAD VALVE CON
|
|||
|
:= -MA28.0 COMPONENT VAL 1
|
|||
|
:
|
|||
|
:O(
|
|||
|
:A -MA28.0 COMPONENT VAL 1 01
|
|||
|
:A -ME30.0 COMPV_1 CL/pos.1 01
|
|||
|
:AN -ME31.0 COMPV_1 pos. 2 01
|
|||
|
:A F 212.0 01 silo 1
|
|||
|
:) 01
|
|||
|
:O(
|
|||
|
:A -ME31.0 COMPV_1 pos. 2 01
|
|||
|
:AN F 212.0 01 silo 1
|
|||
|
:) 01
|
|||
|
:= F 200.0
|
|||
|
:***
|
|||
|
|
|||
|
F 24.2 = MA24.2 UNLOAD VALVE CON
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 6
|
|||
|
F 26.2 = ME26.2 UNLOAD VALVE CON
|
|||
|
F 28.0 = MA28.0 COMPONENT VAL 1
|
|||
|
F 30.0 = ME30.0 COMPV_1 CL/pos.1
|
|||
|
F 31.0 = ME31.0 COMPV_1 pos. 2
|
|||
|
|
|||
|
Segment 13 conveying pressure built up
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 151
|
|||
|
AUSG : FW 204
|
|||
|
: --------------------------------
|
|||
|
:LW =T2
|
|||
|
:T FW 202
|
|||
|
:
|
|||
|
:A -MA24.2 UNLOAD VALVE CON
|
|||
|
:A -ME26.2 UNLOAD VALVE CON
|
|||
|
:AN -ME27.2 UNLOAD V. RUN TH
|
|||
|
:A F 200.0
|
|||
|
:L FW 204 time until conveying pressure
|
|||
|
:DO FW 202 built up
|
|||
|
:SD -T0 IND.ADDRES.(DUMMY)
|
|||
|
:DO FW 202
|
|||
|
:A -T0 IND.ADDRES.(DUMMY)
|
|||
|
:= -M 18.2 PRESSUR_BUILD_UP
|
|||
|
:***
|
|||
|
|
|||
|
F 24.2 = MA24.2 UNLOAD VALVE CON
|
|||
|
F 26.2 = ME26.2 UNLOAD VALVE CON
|
|||
|
F 27.2 = ME27.2 UNLOAD V. RUN TH
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
F 18.2 = M 18.2 PRESSUR_BUILD_UP
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 14 release dosing to scale module
|
|||
|
:L DW 50 silo_no
|
|||
|
:L KF +1
|
|||
|
:!=F
|
|||
|
:= F 200.0 wand
|
|||
|
:
|
|||
|
:O(
|
|||
|
:A -MA20.1 DOSING UNIT ON 01
|
|||
|
:A -ME22.1 DOSING UNIT ON 01
|
|||
|
:AN F 200.0 01 wand
|
|||
|
:) 01
|
|||
|
:O F 200.0 wand
|
|||
|
:A -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:A -M 18.2 PRESSUR_BUILD_UP
|
|||
|
:A -M 18.0 SILO_NR_OK
|
|||
|
:= -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:***
|
|||
|
|
|||
|
F 20.1 = MA20.1 DOSING UNIT ON
|
|||
|
F 22.1 = ME22.1 DOSING UNIT ON
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 18.2 = M 18.2 PRESSUR_BUILD_UP
|
|||
|
F 18.0 = M 18.0 SILO_NR_OK
|
|||
|
F 11.2 = ME11.2 DOS.REL.CNTR/MAN plc scale EST 1
|
|||
|
|
|||
|
Segment 15 read pressure
|
|||
|
:L KF +0
|
|||
|
:T FY 180 0 =P-address
|
|||
|
:LW =PWDT
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 7
|
|||
|
:T FY 181
|
|||
|
:
|
|||
|
:JU -FB118 PRESSURE TRANSMIT
|
|||
|
Name :DRUCKAUF
|
|||
|
BGRN : -MW180 PARAMETER 1
|
|||
|
OG : DW 123
|
|||
|
UG : DW 122
|
|||
|
AUSG : DW 124 relative convey. pressure
|
|||
|
FEHL : F 200.0
|
|||
|
AKTV : -ME31.4 VACUUM ACTIV
|
|||
|
TIMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
S5S7 : KS S5
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 31.4 = ME31.4 VACUUM ACTIV
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 118 = FB118 PRESSURE TRANSMIT hkt as
|
|||
|
|
|||
|
Segment 16 pressure high
|
|||
|
:L DW 124 actual pressure
|
|||
|
:L DW 125 min pressure
|
|||
|
:>F
|
|||
|
:R -M 18.4 PRESSURE_HIGH
|
|||
|
:
|
|||
|
:L DW 124 actual pressure
|
|||
|
:L DW 126 max pressure
|
|||
|
:<F
|
|||
|
:O F 200.0
|
|||
|
:S -M 18.4 PRESSURE_HIGH
|
|||
|
:***
|
|||
|
|
|||
|
F 18.4 = M 18.4 PRESSURE_HIGH
|
|||
|
|
|||
|
Segment 17 delay time fault convey.pressure
|
|||
|
:L KF +10
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
Segment 18 output fault conveying pressure
|
|||
|
:L DW 170
|
|||
|
:T FW 202
|
|||
|
:
|
|||
|
:JU -FB108 TIMER IMITATION
|
|||
|
Name :TIMER
|
|||
|
STRT : -M 18.4 PRESSURE_HIGH
|
|||
|
RSET : -M 0.2 CONSTANT 0
|
|||
|
AKTI : F 202.0
|
|||
|
AUSG : -M 18.6 PRESSURE_FAULT
|
|||
|
TTYP : KS SE
|
|||
|
SOLL : -MW180 PARAMETER 1
|
|||
|
IST : DW 172
|
|||
|
IMP : -M 0.3 1 SEC. IMPULSE
|
|||
|
:
|
|||
|
:L FW 202
|
|||
|
:T DW 170
|
|||
|
:***
|
|||
|
|
|||
|
F 18.4 = M 18.4 PRESSURE_HIGH
|
|||
|
F 0.2 = M 0.2 CONSTANT 0
|
|||
|
F 18.6 = M 18.6 PRESSURE_FAULT
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 8
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
FB 108 = FB108 TIMER IMITATION e.g. for scale control WK al
|
|||
|
|
|||
|
Segment 19 release dosing silo
|
|||
|
:O -MA15.7 CNTR.WEI.DOS.ACT
|
|||
|
:O -MA17.1 HEAL/E.SUCK. ACT
|
|||
|
:A(
|
|||
|
:L DW 50 01 silo_no
|
|||
|
:L KF +1 01
|
|||
|
:><F 01 not wand selected
|
|||
|
:) 01
|
|||
|
:AN -M 18.4 PRESSURE_HIGH
|
|||
|
:A -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:= -M 18.5 DOS_REL_SILO
|
|||
|
:
|
|||
|
:AN -MA20.2 FREQ.CONV. REL.
|
|||
|
:L KF +0
|
|||
|
:JC =M001
|
|||
|
:AN -M 19.1 CONTROL FINE
|
|||
|
:L DW 56 coarse
|
|||
|
:JC =M001
|
|||
|
:L DW 57 fine
|
|||
|
M001 :T DW 146 speed of dosing screw to silo
|
|||
|
:***
|
|||
|
|
|||
|
F 15.7 = MA15.7 CNTR.WEI.DOS.ACT plc scale AST 1
|
|||
|
F 17.1 = MA17.1 HEAL/E.SUCK. ACT plc scale AST 2
|
|||
|
F 18.4 = M 18.4 PRESSURE_HIGH
|
|||
|
F 11.2 = ME11.2 DOS.REL.CNTR/MAN plc scale EST 1
|
|||
|
F 18.5 = M 18.5 DOS_REL_SILO
|
|||
|
F 20.2 = MA20.2 FREQ.CONV. REL. *** not used
|
|||
|
F 19.1 = M 19.1 CONTROL FINE
|
|||
|
|
|||
|
Segment 20 rel. convey. silo (outlet flap)
|
|||
|
:A -MA15.7 CNTR.WEI.DOS.ACT
|
|||
|
:AN -M 18.4 PRESSURE_HIGH
|
|||
|
:A -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:= -M 19.5 CONVEY_REL_SILO
|
|||
|
:
|
|||
|
:A -M 19.5 CONVEY_REL_SILO
|
|||
|
:= -ME11.4 DOS.UNIT RUN.POS
|
|||
|
:***
|
|||
|
|
|||
|
F 15.7 = MA15.7 CNTR.WEI.DOS.ACT plc scale AST 1
|
|||
|
F 18.4 = M 18.4 PRESSURE_HIGH
|
|||
|
F 11.2 = ME11.2 DOS.REL.CNTR/MAN plc scale EST 1
|
|||
|
F 19.5 = M 19.5 CONVEY_REL_SILO
|
|||
|
F 11.4 = ME11.4 DOS.UNIT RUN.POS plc scale EST 1
|
|||
|
|
|||
|
Segment 21 check tolerance
|
|||
|
:LW =T8
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:LW =T9
|
|||
|
:T -MW182 PARAMETER 2
|
|||
|
:
|
|||
|
:JU -FB92 CONTROL_WEIGHING
|
|||
|
Name :CTR-WEIG
|
|||
|
WZNR : DW 1
|
|||
|
TOLE : DD 110
|
|||
|
TTOL : -MW180 PARAMETER 1
|
|||
|
EOCW : -M 19.2 CTRL-WEI IN TOLE
|
|||
|
TFIN : -MW182 PARAMETER 2
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 9
|
|||
|
CTRF : -M 19.1 CONTROL FINE
|
|||
|
DOSI : -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
DFIN : -ME31.3 REL CTRL-FINE
|
|||
|
:
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 19.2 = M 19.2 CTRL-WEI IN TOLE
|
|||
|
F 19.1 = M 19.1 CONTROL FINE
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 31.3 = ME31.3 REL CTRL-FINE
|
|||
|
|
|||
|
FB 92 = FB92 CONTROL_WEIGHING
|
|||
|
|
|||
|
Segment 22 receipt control weighing
|
|||
|
: *unm19.1
|
|||
|
:A -MA21.5 >SILO EMPTY
|
|||
|
:A -M 19.2 CTRL-WEI IN TOLE
|
|||
|
:= =ECSI
|
|||
|
:
|
|||
|
:A -M 19.2 CTRL-WEI IN TOLE u=ecsi // ???
|
|||
|
:A(
|
|||
|
:L =CPSI 01
|
|||
|
:L KF +90 01 Step 90: stop charge
|
|||
|
:>=F 01
|
|||
|
:) 01
|
|||
|
:A -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:S -ME10.2 RECPT.CNTR.WEIGH
|
|||
|
:
|
|||
|
:AN -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:R -ME10.2 RECPT.CNTR.WEIGH
|
|||
|
:***
|
|||
|
|
|||
|
F 21.5 = MA21.5 >SILO EMPTY
|
|||
|
F 19.2 = M 19.2 CTRL-WEI IN TOLE
|
|||
|
F 11.2 = ME11.2 DOS.REL.CNTR/MAN plc scale EST 1
|
|||
|
F 10.2 = ME10.2 RECPT.CNTR.WEIGH plc scale EST 1
|
|||
|
|
|||
|
Segment 23 rel. cleaning filter
|
|||
|
:O(
|
|||
|
:A -MA24.5 OUTLETFLAP OPEN 01
|
|||
|
:A -ME26.5 OUTLETFLAP OPEN 01
|
|||
|
:AN -ME27.5 OUTLETFL. CLOSED 01
|
|||
|
:AN -MA17.3 STRT.DISCH.HELP 01
|
|||
|
:AN -MA16.6 FIN.DISCHARG.FIN 01
|
|||
|
:AN -MA16.7 INT.DISCHARG.FIN 01
|
|||
|
:) 01
|
|||
|
:O -ME11.4 DOS.UNIT RUN.POS
|
|||
|
:= F 200.0
|
|||
|
:***
|
|||
|
|
|||
|
F 24.5 = MA24.5 OUTLETFLAP OPEN
|
|||
|
F 26.5 = ME26.5 OUTLETFLAP OPEN
|
|||
|
F 27.5 = ME27.5 OUTLETFL. CLOSED
|
|||
|
F 17.3 = MA17.3 STRT.DISCH.HELP plc scale AST 2
|
|||
|
F 16.6 = MA16.6 FIN.DISCHARG.FIN plc scale AST 2
|
|||
|
F 16.7 = MA16.7 INT.DISCHARG.FIN plc scale AST 2
|
|||
|
F 11.4 = ME11.4 DOS.UNIT RUN.POS plc scale EST 1
|
|||
|
|
|||
|
Segment 24 timer no. cycle filter
|
|||
|
:L DW 152
|
|||
|
:T -MW182 PARAMETER 2
|
|||
|
:
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 10
|
|||
|
:L DW 153
|
|||
|
:T -MW184 PARAMETER 3
|
|||
|
:
|
|||
|
:A -ME11.4 DOS.UNIT RUN.POS
|
|||
|
:JC =M001 --------------------------------
|
|||
|
:
|
|||
|
:L DW 156
|
|||
|
:T -MW182 PARAMETER 2
|
|||
|
:
|
|||
|
:L DW 157
|
|||
|
:T -MW184 PARAMETER 3
|
|||
|
M001 :***
|
|||
|
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
F 11.4 = ME11.4 DOS.UNIT RUN.POS plc scale EST 1
|
|||
|
|
|||
|
Segment 25 time cycle filter cleaning
|
|||
|
:LW =T3
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +1 convert impulse time
|
|||
|
EING : -MW182 PARAMETER 2
|
|||
|
AUSG : FW 202
|
|||
|
: --------------------------------
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2 convert break time
|
|||
|
EING : -MW184 PARAMETER 3
|
|||
|
AUSG : FW 204
|
|||
|
: --------------------------------
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 26 cycle purged air filter cleaning
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : F 200.0
|
|||
|
T : -T0 IND.ADDRES.(DUMMY)
|
|||
|
DWIM : FW 202
|
|||
|
DWPA : FW 204
|
|||
|
AUSG : -M 19.0 FILTER ACTIV
|
|||
|
POS : -M 0.1 CONSTANT 1
|
|||
|
DBT : -DB31 HO561 SCALE3:DR540
|
|||
|
RM : -M 19.0 FILTER ACTIV
|
|||
|
T-IN : -MW180 PARAMETER 1
|
|||
|
IN : KS IN
|
|||
|
SOLL : KF +3
|
|||
|
IST : DW 147
|
|||
|
FERT : F 200.1
|
|||
|
BITL : DW 148
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB31 HO561 SCALE3:DR540
|
|||
|
:***
|
|||
|
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
F 19.0 = M 19.0 FILTER ACTIV
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 11
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
DB 31 = DB31 HO561 SCALE3:DR540 HO561 area 3 scale 3: from dryer
|
|||
|
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 27 filter 1-3 on
|
|||
|
:A -M 19.0 FILTER ACTIV
|
|||
|
:A D 148.0
|
|||
|
:= -MA25.2 FILTER 1 ON
|
|||
|
:
|
|||
|
:A -M 19.0 FILTER ACTIV
|
|||
|
:A D 148.1
|
|||
|
:= -MA25.3 FILTER 2 ON
|
|||
|
:
|
|||
|
:A -M 19.0 FILTER ACTIV
|
|||
|
:A D 148.2
|
|||
|
:= -MA25.4 FILTER 3 ON
|
|||
|
:***
|
|||
|
|
|||
|
F 19.0 = M 19.0 FILTER ACTIV
|
|||
|
F 25.2 = MA25.2 FILTER 1 ON
|
|||
|
F 25.3 = MA25.3 FILTER 2 ON
|
|||
|
F 25.4 = MA25.4 FILTER 3 ON
|
|||
|
|
|||
|
Segment 28 ackn. register request
|
|||
|
:A -MA17.5 REGISTR.REQUEST
|
|||
|
:= -ME13.5 REL.FOR REGISTR.
|
|||
|
:S D 112.1 *(4) hf registration
|
|||
|
:***
|
|||
|
|
|||
|
F 17.5 = MA17.5 REGISTR.REQUEST plc scale AST 2
|
|||
|
F 13.5 = ME13.5 REL.FOR REGISTR. plc scale EST 2
|
|||
|
|
|||
|
Segment 29 max. empty level
|
|||
|
:L DD 106 max. empty weight
|
|||
|
:T FD 190
|
|||
|
:
|
|||
|
:L DW 1 scale number
|
|||
|
:L KF +100
|
|||
|
:+F
|
|||
|
:T FW 200
|
|||
|
:
|
|||
|
:DO FW 200
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:
|
|||
|
:L DD 38 scale empty level
|
|||
|
:L FD 190
|
|||
|
:>=G
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 38 scale empty level
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 30 load gross/ registrated weight
|
|||
|
:L DD 198 gross weight
|
|||
|
:T FD 190 gross weight scale
|
|||
|
:
|
|||
|
:L DD 195 registrated weight
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 12
|
|||
|
:T FD 200 registrated weight scale
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 31 empty check
|
|||
|
:DO -MW 34 ADDR.SCALE_DB
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:
|
|||
|
:L DD 106 max. empty weight
|
|||
|
:L FD 190
|
|||
|
:>=G
|
|||
|
:A(
|
|||
|
:L DD 108 01 min. empty weight
|
|||
|
:L FD 190 01
|
|||
|
:<=G 01
|
|||
|
:) 01
|
|||
|
:= =EMPY
|
|||
|
:***
|
|||
|
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 32 start weight / reg.weight fillin
|
|||
|
:O -MA17.0 TARNG/CALMNG ACT
|
|||
|
:O D 112.0 hf taring act
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 132 start weight filling
|
|||
|
M001 :
|
|||
|
:A -MA17.0 TARNG/CALMNG ACT
|
|||
|
:S D 112.0 hf taring act
|
|||
|
:
|
|||
|
:AN -ME13.5 REL.FOR REGISTR. *** NO EFFECT DURING TEST
|
|||
|
:JC =M002 ***
|
|||
|
: ***
|
|||
|
:L FD 190 ***
|
|||
|
:T DD 134 *** end weight filling
|
|||
|
M002 : ***
|
|||
|
:L FD 200
|
|||
|
:T DD 130 registrated weight filling
|
|||
|
: }}} TEST {{{
|
|||
|
:L DD 132 start weight filling
|
|||
|
:L DD 130 registrated weight filling
|
|||
|
:+G
|
|||
|
:T DD 134 end weight filling
|
|||
|
:***
|
|||
|
|
|||
|
F 17.0 = MA17.0 TARNG/CALMNG ACT plc scale AST 2
|
|||
|
F 13.5 = ME13.5 REL.FOR REGISTR. plc scale EST 2
|
|||
|
|
|||
|
Segment 33
|
|||
|
: from this network on starts
|
|||
|
: the discharging of the scale
|
|||
|
:
|
|||
|
:L DD 130 *(4) registrated weight
|
|||
|
:L KG +0000000+00 *(4)
|
|||
|
:><G *(4)
|
|||
|
:= D 112.2 *(4) hf registrated weight
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 34 open outletflap
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 13
|
|||
|
:A -MA16.4 DISCHARGE
|
|||
|
:AN -MA24.2 UNLOAD VALVE CON
|
|||
|
:AN -ME26.2 UNLOAD VALVE CON
|
|||
|
:A -ME27.2 UNLOAD V. RUN TH
|
|||
|
:= -ME10.0 RELEASE DISCHARG
|
|||
|
:
|
|||
|
:A -ME10.0 RELEASE DISCHARG
|
|||
|
:A -ME31.7 SCALE_DISCH REL.
|
|||
|
:= -MA24.5 OUTLETFLAP OPEN
|
|||
|
:
|
|||
|
:A -MA24.5 OUTLETFLAP OPEN
|
|||
|
:A -ME26.5 OUTLETFLAP OPEN
|
|||
|
:AN -ME27.5 OUTLETFL. CLOSED
|
|||
|
:= -MA29.7 SCALE_DISCH ON
|
|||
|
:***
|
|||
|
|
|||
|
F 16.4 = MA16.4 DISCHARGE plc scale AST 2
|
|||
|
F 24.2 = MA24.2 UNLOAD VALVE CON
|
|||
|
F 26.2 = ME26.2 UNLOAD VALVE CON
|
|||
|
F 27.2 = ME27.2 UNLOAD V. RUN TH
|
|||
|
F 10.0 = ME10.0 RELEASE DISCHARG plc scale EST 1
|
|||
|
F 31.7 = ME31.7 SCALE_DISCH REL.
|
|||
|
F 24.5 = MA24.5 OUTLETFLAP OPEN
|
|||
|
F 26.5 = ME26.5 OUTLETFLAP OPEN
|
|||
|
F 27.5 = ME27.5 OUTLETFL. CLOSED
|
|||
|
F 29.7 = MA29.7 SCALE_DISCH ON
|
|||
|
|
|||
|
Segment 35 time vibration motor
|
|||
|
:LW =T5
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2 convert impulse time
|
|||
|
EING : DW 154
|
|||
|
AUSG : FW 202
|
|||
|
: --------------------------------
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2 convert break time
|
|||
|
EING : DW 155
|
|||
|
AUSG : FW 204
|
|||
|
: --------------------------------
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 36 cycle vibration motor
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : -MA29.7 SCALE_DISCH ON
|
|||
|
T : -T0 IND.ADDRES.(DUMMY)
|
|||
|
DWIM : FW 202
|
|||
|
DWPA : FW 204
|
|||
|
AUSG : -MA24.1 VIBRATOR ON
|
|||
|
POS : -M 0.1 CONSTANT 1
|
|||
|
DBT : -DB31 HO561 SCALE3:DR540
|
|||
|
RM : -ME26.1 VIBRATOR ON
|
|||
|
T-IN : -MW180 PARAMETER 1
|
|||
|
IN : KS IN
|
|||
|
SOLL : KF +0
|
|||
|
IST : FW 206
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 14
|
|||
|
FERT : F 200.1
|
|||
|
BITL : FW 208
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB31 HO561 SCALE3:DR540
|
|||
|
:***
|
|||
|
|
|||
|
F 29.7 = MA29.7 SCALE_DISCH ON
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
F 24.1 = MA24.1 VIBRATOR ON
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 26.1 = ME26.1 VIBRATOR ON
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
|
|||
|
DB 31 = DB31 HO561 SCALE3:DR540 HO561 area 3 scale 3: from dryer
|
|||
|
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 37 got weight value to scale module
|
|||
|
:A -MA16.6 FIN.DISCHARG.FIN
|
|||
|
:= =EDSI
|
|||
|
:
|
|||
|
:O( *(6)
|
|||
|
:L =DPSI 01
|
|||
|
:L KF +90 01 Step 90: stop discharge
|
|||
|
:>=F 01
|
|||
|
:) 01
|
|||
|
:ON -ME31.6 PLI_DISCHARG.RUN *(6)
|
|||
|
:A =EDSI
|
|||
|
:= -ME10.1 SCALE DISCHARGED
|
|||
|
:
|
|||
|
:A -MA16.3 TAKEOV.WEIGHT VA
|
|||
|
:= -ME10.5 GOT WEIGHT VALUE
|
|||
|
:
|
|||
|
:AN -ME10.1 SCALE DISCHARGED
|
|||
|
:JC =M001
|
|||
|
:L KF +0
|
|||
|
:T DW 50 delete silo no.
|
|||
|
:T DW 51 delete consumer no.
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 16.6 = MA16.6 FIN.DISCHARG.FIN plc scale AST 2
|
|||
|
F 31.6 = ME31.6 PLI_DISCHARG.RUN *(6)
|
|||
|
F 10.1 = ME10.1 SCALE DISCHARGED plc scale EST 1
|
|||
|
F 16.3 = MA16.3 TAKEOV.WEIGHT VA plc scale AST 2
|
|||
|
F 10.5 = ME10.5 GOT WEIGHT VALUE plc scale EST 1
|
|||
|
|
|||
|
Segment 38 start weight / end weight discha
|
|||
|
:ON -MA24.5 OUTLETFLAP OPEN
|
|||
|
:ON -MA16.5 FINAL DISCHARGE
|
|||
|
:AN D 112.1 *(4) hf registration by CHARGE
|
|||
|
:JC =M001
|
|||
|
:ON D 112.2 *(4) hf registrated weight
|
|||
|
:O -M 19.4 GOT_DIS_STRT WEI
|
|||
|
:JC =M001
|
|||
|
: *(4)
|
|||
|
:A D 112.1 *(4) hf registration by CHARGE
|
|||
|
:L DD 134 *(4) end weight filling
|
|||
|
:JC =M002 *(4)
|
|||
|
:L FD 190
|
|||
|
M002 :T DD 138 *(4)MARK start weight discharge
|
|||
|
:A -M 0.1 CONSTANT 1
|
|||
|
:S -M 19.4 GOT_DIS_STRT WEI
|
|||
|
M001 :
|
|||
|
:AN -ME10.1 SCALE DISCHARGED
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 15
|
|||
|
:JC =M003
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 140 end weight discharge
|
|||
|
M003 :
|
|||
|
:A -ME10.5 GOT WEIGHT VALUE
|
|||
|
:R -M 19.4 GOT_DIS_STRT WEI
|
|||
|
: *(4)
|
|||
|
:A -M 19.4 GOT_DIS_STRT WEI *(4)
|
|||
|
:R D 112.1 *(4) hf registration
|
|||
|
:***
|
|||
|
|
|||
|
F 24.5 = MA24.5 OUTLETFLAP OPEN
|
|||
|
F 16.5 = MA16.5 FINAL DISCHARGE plc scale AST 2
|
|||
|
F 19.4 = M 19.4 GOT_DIS_STRT WEI
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 10.1 = ME10.1 SCALE DISCHARGED plc scale EST 1
|
|||
|
F 10.5 = ME10.5 GOT WEIGHT VALUE plc scale EST 1
|
|||
|
|
|||
|
Segment 39 discharged weight
|
|||
|
: ldd142 discharged weight
|
|||
|
:L DD 138 weight at start
|
|||
|
:L DD 140 weight at end
|
|||
|
:-G
|
|||
|
:T DD 136 prepare for block transfer
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 40 delete report charge
|
|||
|
:L =CPSI
|
|||
|
:L KF +40
|
|||
|
:>=F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KG +0000000+00 erase
|
|||
|
:T DD 130 registrated weight
|
|||
|
:T DD 132 start weight charge
|
|||
|
:T DD 134 end weight charge
|
|||
|
:T DD 112 status
|
|||
|
:
|
|||
|
:A -M 0.1 CONSTANT 1
|
|||
|
:R D 112.0 hf taring act
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
|
|||
|
Segment 41 delete report discharge
|
|||
|
:L =DPSI
|
|||
|
:L KF +40
|
|||
|
:>=F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KG +0000000+00 erase
|
|||
|
:T DD 136 discharged weight
|
|||
|
: *(4)
|
|||
|
:T DD 140 end weight discharge
|
|||
|
:T DD 142 Discharged weight
|
|||
|
:
|
|||
|
:A -M 19.4 GOT_DIS_STRT WEI *(4)
|
|||
|
:JC =M001 *(4)
|
|||
|
: *(4)
|
|||
|
:L KG +0000000+00 *(4)
|
|||
|
:T DD 138 *(4) start weight discharge
|
|||
|
M001 :***
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 16
|
|||
|
F 19.4 = M 19.4 GOT_DIS_STRT WEI
|
|||
|
|
|||
|
Segment 42 signal display
|
|||
|
:A -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:AN -M 19.1 CONTROL FINE
|
|||
|
:O -MA14.0 NEGATIVE COURSE
|
|||
|
:O -MA15.0 POSITIVE COURSE
|
|||
|
:= -M 90.0 COARSE_SPEED
|
|||
|
:
|
|||
|
:O -M 19.1 CONTROL FINE
|
|||
|
:O -MA14.1 NEGATIVE FINE
|
|||
|
:O -MA15.1 POSITIVE FINE
|
|||
|
:= -M 90.1 FINE_SPEED
|
|||
|
:
|
|||
|
:O -MA14.2 NEGATIVE EX-FINE
|
|||
|
:O -MA15.2 POSITIVE EX-FINE
|
|||
|
:= -M 90.2 EXTRAFINE_SPEED
|
|||
|
:
|
|||
|
:O -MA14.4 NEG.COMPO.ACTIVE
|
|||
|
:O -MA15.4 POS.COMPO.ACTIVE
|
|||
|
:O -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:S D 112.7 display registrated weight
|
|||
|
:A -MA16.4 DISCHARGE
|
|||
|
:R D 112.7 display registrated weight
|
|||
|
:***
|
|||
|
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 19.1 = M 19.1 CONTROL FINE
|
|||
|
F 14.0 = MA14.0 NEGATIVE COURSE plc scale AST 1
|
|||
|
F 15.0 = MA15.0 POSITIVE COURSE plc scale AST 1
|
|||
|
F 90.0 = M 90.0 COARSE_SPEED
|
|||
|
F 14.1 = MA14.1 NEGATIVE FINE plc scale AST 1
|
|||
|
F 15.1 = MA15.1 POSITIVE FINE plc scale AST 1
|
|||
|
F 90.1 = M 90.1 FINE_SPEED
|
|||
|
F 14.2 = MA14.2 NEGATIVE EX-FINE plc scale AST 1
|
|||
|
F 15.2 = MA15.2 POSITIVE EX-FINE plc scale AST 1
|
|||
|
F 90.2 = M 90.2 EXTRAFINE_SPEED
|
|||
|
F 14.4 = MA14.4 NEG.COMPO.ACTIVE plc scale AST 1
|
|||
|
F 15.4 = MA15.4 POS.COMPO.ACTIVE plc scale AST 1
|
|||
|
F 16.4 = MA16.4 DISCHARGE plc scale AST 2
|
|||
|
|
|||
|
Segment 43 store status of weighing
|
|||
|
:L -MW 10 I-CONTROLBITs
|
|||
|
:T DW 6
|
|||
|
:L -MW 12 I-CONTROLBITs interface to scale module
|
|||
|
:T DW 7
|
|||
|
:L -MW 14 O-CONTROLBITs
|
|||
|
:T DW 52
|
|||
|
:L -MW 16 O-CONTROLBITs
|
|||
|
:T DW 53
|
|||
|
: --------------------------------
|
|||
|
:L -MW24 IND. OUTPUTS SCALE outputs / inputs
|
|||
|
:T DW 115
|
|||
|
:L -MW26 IND. INPUTS SCALE
|
|||
|
:T DW 116
|
|||
|
:L -MW28 IND. OUTPUTS WAY
|
|||
|
:T DW 117
|
|||
|
:L -MW30 IND. INPUTS WAY
|
|||
|
:T DW 118
|
|||
|
: --------------------------------
|
|||
|
:***
|
|||
|
|
|||
|
FW 10 = MW 10 I-CONTROLBITs plc scale EST 1
|
|||
|
FW 12 = MW 12 I-CONTROLBITs plc scale EST 2
|
|||
|
FB 31 -FB31 HO561 SCALE3:DR540 C:ZONE10ST.S5D LEN=738
|
|||
|
Page 17
|
|||
|
FW 14 = MW 14 O-CONTROLBITs plc scale AST 1
|
|||
|
FW 16 = MW 16 O-CONTROLBITs plc scale AST 2
|
|||
|
FW 24 = MW24 IND. OUTPUTS SCALE
|
|||
|
FW 26 = MW26 IND. INPUTS SCALE
|
|||
|
FW 28 = MW28 IND. OUTPUTS WAY
|
|||
|
FW 30 = MW30 IND. INPUTS WAY
|
|||
|
|
|||
|
Segment 44 store status of weighing
|
|||
|
:L -MW18 STATUS FLAGS internal variable weighing
|
|||
|
:T DW 114
|
|||
|
: --------------------------------
|
|||
|
:L -MB90 SIGNAL DISPLAY signal display
|
|||
|
:T DR 119
|
|||
|
:BE
|
|||
|
|
|||
|
FW 18 = MW18 STATUS FLAGS SCALE STATUS
|
|||
|
FY 90 = MB90 SIGNAL DISPLAY SCALE SIGNAL DISPLAY
|
|||
|
|
|||
|
FB 41 -FB41 HO580 SCALE4:BD560 C:ZONE10ST.S5D LEN=421
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
******************************************************************************
|
|||
|
|
|||
|
DESCRIPTION :
|
|||
|
|
|||
|
This block handles the control weighing from dryer via cone mill container
|
|||
|
scale HO580.
|
|||
|
|
|||
|
|
|||
|
|
|||
|
******************************************************************************
|
|||
|
|
|||
|
PARAMETER :
|
|||
|
|
|||
|
LINR : line number
|
|||
|
WANR : scale number
|
|||
|
WZNR : scale count number ( to calculate to datablock )
|
|||
|
T1 : timer 1 ( TTOL FB92 )
|
|||
|
T2 : timer 2 ( TFIN FB92 )
|
|||
|
T3 : timer 3 ( delay registration )
|
|||
|
CPSI : charge phase step index
|
|||
|
ECSI : end of charge step
|
|||
|
DPSI : discharge phase step index
|
|||
|
EDSI : end of discharge step
|
|||
|
EMPY : empty check ( MIN<x<MAX )
|
|||
|
|
|||
|
*******************************************************************************
|
|||
|
|
|||
|
INTERNAL USED BLOCKS :
|
|||
|
|
|||
|
FB 190 Scale module
|
|||
|
FB 92 Control weighing
|
|||
|
|
|||
|
*******************************************************************************
|
|||
|
|
|||
|
Name :WAAGE
|
|||
|
Decl :LINR I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :WANR I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :WZNR I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T1 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T2 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :T3 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :CPSI I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :ECSI I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :DPSI I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :EMPY I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2
|
|||
|
:LW =LINR
|
|||
|
:SLW 3
|
|||
|
:LW =LINR
|
|||
|
:SLW 1
|
|||
|
:+F
|
|||
|
:T -MW 32 ADDR.LINE_DB
|
|||
|
:
|
|||
|
:LW =WANR
|
|||
|
:+F
|
|||
|
:T -MW 34 ADDR.SCALE_DB
|
|||
|
:
|
|||
|
:LW =WZNR
|
|||
|
:L KF +164
|
|||
|
FB 41 -FB41 HO580 SCALE4:BD560 C:ZONE10ST.S5D LEN=421
|
|||
|
Page 2
|
|||
|
:+F
|
|||
|
:T -MW 38 ADDR.DOS_ADR_DB
|
|||
|
:***
|
|||
|
|
|||
|
FW 32 = MW 32 ADDR.LINE_DB
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
FW 38 = MW 38 ADDR.DOS_ADR_DB
|
|||
|
|
|||
|
Segment 3
|
|||
|
:DO -MW 34 ADDR.SCALE_DB
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:
|
|||
|
:LW =WZNR
|
|||
|
:T DW 1
|
|||
|
:
|
|||
|
:L -MW 34 ADDR.SCALE_DB
|
|||
|
:T DW 4
|
|||
|
:
|
|||
|
:L -MW 38 ADDR.DOS_ADR_DB
|
|||
|
:T DW 5
|
|||
|
:***
|
|||
|
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
FW 38 = MW 38 ADDR.DOS_ADR_DB
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 4
|
|||
|
:L DW 6
|
|||
|
:T -MW 10 I-CONTROLBITs
|
|||
|
:L DW 7
|
|||
|
:T -MW 12 I-CONTROLBITs
|
|||
|
:L DW 52
|
|||
|
:T -MW 14 O-CONTROLBITs
|
|||
|
:L DW 53
|
|||
|
:T -MW 16 O-CONTROLBITs
|
|||
|
:
|
|||
|
:L DW 114
|
|||
|
:T -MW18 STATUS FLAGS
|
|||
|
:
|
|||
|
:L DW 115
|
|||
|
:T -MW24 IND. OUTPUTS SCALE
|
|||
|
:L DW 117
|
|||
|
:T -MW28 IND. OUTPUTS WAY
|
|||
|
:
|
|||
|
:L DR 119
|
|||
|
:T -MB90 SIGNAL DISPLAY
|
|||
|
:***
|
|||
|
|
|||
|
FW 10 = MW 10 I-CONTROLBITs plc scale EST 1
|
|||
|
FW 12 = MW 12 I-CONTROLBITs plc scale EST 2
|
|||
|
FW 14 = MW 14 O-CONTROLBITs plc scale AST 1
|
|||
|
FW 16 = MW 16 O-CONTROLBITs plc scale AST 2
|
|||
|
FW 18 = MW18 STATUS FLAGS SCALE STATUS
|
|||
|
FW 24 = MW24 IND. OUTPUTS SCALE
|
|||
|
FW 28 = MW28 IND. OUTPUTS WAY
|
|||
|
FY 90 = MB90 SIGNAL DISPLAY SCALE SIGNAL DISPLAY
|
|||
|
|
|||
|
Segment 5
|
|||
|
:A -M 0.3 1 SEC. IMPULSE
|
|||
|
:= -ME12.0 1-SEC-IMPULSE
|
|||
|
:
|
|||
|
:AN -M 4.0 GLOBAL AUTO-MODE
|
|||
|
:AN -M 4.1 GLOB. MANUAL-MODE
|
|||
|
FB 41 -FB41 HO580 SCALE4:BD560 C:ZONE10ST.S5D LEN=421
|
|||
|
Page 3
|
|||
|
:O -M 4.2 GLOB.SERVICE-MODE
|
|||
|
:O F 99.7
|
|||
|
:= -ME12.1 PLC-MODE/PC-MODE
|
|||
|
:***
|
|||
|
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
F 12.0 = ME12.0 1-SEC-IMPULSE plc scale EST 2
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
F 4.2 = M 4.2 GLOB.SERVICE-MODE
|
|||
|
F 12.1 = ME12.1 PLC-MODE/PC-MODE plc scale EST 2 (1=PLC-MODE / 0=PC-MODE)
|
|||
|
|
|||
|
Segment 6
|
|||
|
:JU -FB190 SCALE CONTROL
|
|||
|
Name :WAAGE
|
|||
|
W-NR : DW 1
|
|||
|
EST1 : -MW 10 I-CONTROLBITs
|
|||
|
EST2 : -MW 12 I-CONTROLBITs
|
|||
|
AST1 : -MW 14 O-CONTROLBITs
|
|||
|
AST2 : -MW 16 O-CONTROLBITs
|
|||
|
ANDB : -MW 34 ADDR.SCALE_DB
|
|||
|
DBDX : KS DB
|
|||
|
:***
|
|||
|
|
|||
|
FW 10 = MW 10 I-CONTROLBITs plc scale EST 1
|
|||
|
FW 12 = MW 12 I-CONTROLBITs plc scale EST 2
|
|||
|
FW 14 = MW 14 O-CONTROLBITs plc scale AST 1
|
|||
|
FW 16 = MW 16 O-CONTROLBITs plc scale AST 2
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
|
|||
|
FB 190 = FB190 SCALE CONTROL plc scale
|
|||
|
|
|||
|
Segment 7
|
|||
|
:A -MA16.2 LOAD SILO DATA
|
|||
|
:= -ME10.4 GOT SILO DATA
|
|||
|
:***
|
|||
|
|
|||
|
F 16.2 = MA16.2 LOAD SILO DATA plc scale AST 2
|
|||
|
F 10.4 = ME10.4 GOT SILO DATA plc scale EST 1
|
|||
|
|
|||
|
Segment 8
|
|||
|
:L DW 50
|
|||
|
:L KF +1
|
|||
|
:>=F
|
|||
|
:A(
|
|||
|
:L DW 50 01
|
|||
|
:L KF +5 01
|
|||
|
:<=F 01
|
|||
|
:) 01
|
|||
|
:= -M 18.0 SILO_NR_OK
|
|||
|
:***
|
|||
|
|
|||
|
F 18.0 = M 18.0 SILO_NR_OK
|
|||
|
|
|||
|
Segment 9
|
|||
|
:O -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:O -MA15.4 POS.COMPO.ACTIVE
|
|||
|
:= F 210.0
|
|||
|
:
|
|||
|
:JU -FB91 OCCUPY_SILO
|
|||
|
Name :SILO-BEL
|
|||
|
SINR : DW 50
|
|||
|
WADB : -MW 34 ADDR.SCALE_DB
|
|||
|
DOSI : F 210.0
|
|||
|
FB 41 -FB41 HO580 SCALE4:BD560 C:ZONE10ST.S5D LEN=421
|
|||
|
Page 4
|
|||
|
BELG : -M 18.3 SILO_OCCUPIED_OK
|
|||
|
SIOK : -M 18.0 SILO_NR_OK
|
|||
|
OFFS : KF +40
|
|||
|
SIAW : -MW20 IND. OUTPUTS Silo
|
|||
|
SIEW : -MW22 IND. INPUTs Silo
|
|||
|
:***
|
|||
|
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 15.4 = MA15.4 POS.COMPO.ACTIVE plc scale AST 1
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
F 18.3 = M 18.3 SILO_OCCUPIED_OK
|
|||
|
F 18.0 = M 18.0 SILO_NR_OK
|
|||
|
FW 20 = MW20 IND. OUTPUTS Silo
|
|||
|
FW 22 = MW22 IND. INPUTs Silo
|
|||
|
|
|||
|
FB 91 = FB91 OCCUPY_SILO
|
|||
|
|
|||
|
Segment 10
|
|||
|
:O -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:O -MA15.4 POS.COMPO.ACTIVE
|
|||
|
:= -MA24.0 VACUUMPUMP ON
|
|||
|
:***
|
|||
|
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 15.4 = MA15.4 POS.COMPO.ACTIVE plc scale AST 1
|
|||
|
F 24.0 = MA24.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
|
|||
|
Segment 11
|
|||
|
:A -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:A -M 18.0 SILO_NR_OK
|
|||
|
:A -MA24.0 VACUUMPUMP ON
|
|||
|
:A -ME26.0 VACUUMPUMP ON
|
|||
|
:A -ME26.7 CONTAINER OK
|
|||
|
:= -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:
|
|||
|
:A -MA15.4 POS.COMPO.ACTIVE
|
|||
|
:A -M 18.0 SILO_NR_OK
|
|||
|
:A -MA24.0 VACUUMPUMP ON
|
|||
|
:A -ME26.0 VACUUMPUMP ON
|
|||
|
:A -ME26.7 CONTAINER OK
|
|||
|
:= -ME11.0 DOSIN.REL.POSITV
|
|||
|
:***
|
|||
|
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 18.0 = M 18.0 SILO_NR_OK
|
|||
|
F 24.0 = MA24.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
F 26.0 = ME26.0 VACUUMPUMP ON (for HO580: Exhaust)
|
|||
|
F 26.7 = ME26.7 CONTAINER OK
|
|||
|
F 11.2 = ME11.2 DOS.REL.CNTR/MAN plc scale EST 1
|
|||
|
F 15.4 = MA15.4 POS.COMPO.ACTIVE plc scale AST 1
|
|||
|
F 11.0 = ME11.0 DOSIN.REL.POSITV plc scale EST 1
|
|||
|
|
|||
|
Segment 12
|
|||
|
|
|||
|
:LW =T1
|
|||
|
:T -MW180 PARAMETER 1
|
|||
|
:LW =T2
|
|||
|
:T -MW182 PARAMETER 2
|
|||
|
:
|
|||
|
:JU -FB92 CONTROL_WEIGHING
|
|||
|
Name :CTR-WEIG
|
|||
|
WZNR : DW 1
|
|||
|
TOLE : DD 110
|
|||
|
TTOL : -MW180 PARAMETER 1
|
|||
|
FB 41 -FB41 HO580 SCALE4:BD560 C:ZONE10ST.S5D LEN=421
|
|||
|
Page 5
|
|||
|
EOCW : -M 19.2 CTRL-WEI IN TOLE
|
|||
|
TFIN : -MW182 PARAMETER 2
|
|||
|
CTRF : -M 19.1 CONTROL FINE
|
|||
|
DOSI : -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
DFIN : -ME31.3 REL CTRL-FINE
|
|||
|
:
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 19.2 = M 19.2 CTRL-WEI IN TOLE
|
|||
|
F 19.1 = M 19.1 CONTROL FINE
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 31.3 = ME31.3 REL CTRL-FINE
|
|||
|
|
|||
|
FB 92 = FB92 CONTROL_WEIGHING
|
|||
|
|
|||
|
Segment 13
|
|||
|
:A -MA15.7 CNTR.WEI.DOS.ACT
|
|||
|
:A -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:A -ME27.0 DOCKING DEV DOWN
|
|||
|
:= -ME11.4 DOS.UNIT RUN.POS
|
|||
|
:
|
|||
|
:O -MA15.7 CNTR.WEI.DOS.ACT
|
|||
|
:O -MA17.1 HEAL/E.SUCK. ACT
|
|||
|
:O -MA15.5 POS.DOS. ACTIVE
|
|||
|
:= -MA24.6 ENABLE DOCKING D
|
|||
|
:***
|
|||
|
|
|||
|
F 15.7 = MA15.7 CNTR.WEI.DOS.ACT plc scale AST 1
|
|||
|
F 11.2 = ME11.2 DOS.REL.CNTR/MAN plc scale EST 1
|
|||
|
F 27.0 = ME27.0 DOCKING DEV DOWN
|
|||
|
F 11.4 = ME11.4 DOS.UNIT RUN.POS plc scale EST 1
|
|||
|
F 17.1 = MA17.1 HEAL/E.SUCK. ACT plc scale AST 2
|
|||
|
F 15.5 = MA15.5 POS.DOS. ACTIVE plc scale AST 1
|
|||
|
F 24.6 = MA24.6 ENABLE DOCKING D
|
|||
|
|
|||
|
Segment 14
|
|||
|
:A -ME27.6 SILO EMPTY
|
|||
|
:A -M 19.2 CTRL-WEI IN TOLE
|
|||
|
:O
|
|||
|
:A -MA15.4 POS.COMPO.ACTIVE
|
|||
|
:A -MA17.5 REGISTR.REQUEST
|
|||
|
:= =ECSI
|
|||
|
:
|
|||
|
:A -ME27.6 SILO EMPTY
|
|||
|
:A(
|
|||
|
:L =CPSI 01
|
|||
|
:L KF +90 01
|
|||
|
:>=F 01
|
|||
|
:) 01
|
|||
|
:A -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:S -ME10.2 RECPT.CNTR.WEIGH
|
|||
|
:
|
|||
|
:AN -ME11.2 DOS.REL.CNTR/MAN
|
|||
|
:R -ME10.2 RECPT.CNTR.WEIGH
|
|||
|
:***
|
|||
|
|
|||
|
F 27.6 = ME27.6 SILO EMPTY (6)* name changed
|
|||
|
F 19.2 = M 19.2 CTRL-WEI IN TOLE
|
|||
|
F 15.4 = MA15.4 POS.COMPO.ACTIVE plc scale AST 1
|
|||
|
F 17.5 = MA17.5 REGISTR.REQUEST plc scale AST 2
|
|||
|
F 11.2 = ME11.2 DOS.REL.CNTR/MAN plc scale EST 1
|
|||
|
F 10.2 = ME10.2 RECPT.CNTR.WEIGH plc scale EST 1
|
|||
|
FB 41 -FB41 HO580 SCALE4:BD560 C:ZONE10ST.S5D LEN=421
|
|||
|
Page 6
|
|||
|
Segment 15
|
|||
|
:JU -FB106 TRANSFER KF->KT
|
|||
|
Name :KF->KT
|
|||
|
EINH : KF +2
|
|||
|
EING : DW 150
|
|||
|
AUSG : FW 202
|
|||
|
:
|
|||
|
:LW =T3
|
|||
|
:T FW 200
|
|||
|
:
|
|||
|
:A -MA17.5 REGISTR.REQUEST
|
|||
|
:A -ME26.6 DOCKING DEVIC UP
|
|||
|
:L FW 202
|
|||
|
:DO FW 200
|
|||
|
:SD -T0 IND.ADDRES.(DUMMY)
|
|||
|
:
|
|||
|
:DO FW 200
|
|||
|
:A -T0 IND.ADDRES.(DUMMY)
|
|||
|
:= -ME13.5 REL.FOR REGISTR.
|
|||
|
:***
|
|||
|
|
|||
|
F 17.5 = MA17.5 REGISTR.REQUEST plc scale AST 2
|
|||
|
F 26.6 = ME26.6 DOCKING DEVIC UP
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
F 13.5 = ME13.5 REL.FOR REGISTR. plc scale EST 2
|
|||
|
|
|||
|
FB 106 = FB106 TRANSFER KF->KT
|
|||
|
|
|||
|
Segment 16
|
|||
|
:A -MA17.5 REGISTR.REQUEST
|
|||
|
:S -MA25.7 REGISTRATION ACT
|
|||
|
:
|
|||
|
:AN -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:AN -MA15.4 POS.COMPO.ACTIVE
|
|||
|
:R -MA25.7 REGISTRATION ACT
|
|||
|
:***
|
|||
|
|
|||
|
F 17.5 = MA17.5 REGISTR.REQUEST plc scale AST 2
|
|||
|
F 25.7 = MA25.7 REGISTRATION ACT
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 15.4 = MA15.4 POS.COMPO.ACTIVE plc scale AST 1
|
|||
|
|
|||
|
Segment 17
|
|||
|
:L DD 106
|
|||
|
:T FD 190
|
|||
|
:
|
|||
|
:L DW 1
|
|||
|
:L KF +100
|
|||
|
:+F
|
|||
|
:T FW 200
|
|||
|
:
|
|||
|
:DO FW 200
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:
|
|||
|
:L DD 38
|
|||
|
:L FD 190
|
|||
|
:>=G
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 38
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
FB 41 -FB41 HO580 SCALE4:BD560 C:ZONE10ST.S5D LEN=421
|
|||
|
Page 7
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 18
|
|||
|
:L DD 198
|
|||
|
:T FD 190
|
|||
|
:
|
|||
|
:L DD 195
|
|||
|
:T FD 200
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 19
|
|||
|
:DO -MW 34 ADDR.SCALE_DB
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:
|
|||
|
:L DD 106
|
|||
|
:L FD 190
|
|||
|
:>=G
|
|||
|
:A(
|
|||
|
:L DD 108 01
|
|||
|
:L FD 190 01
|
|||
|
:<=G 01
|
|||
|
:) 01
|
|||
|
:= =EMPY
|
|||
|
:***
|
|||
|
|
|||
|
FW 34 = MW 34 ADDR.SCALE_DB
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 20
|
|||
|
:O -MA17.0 TARNG/CALMNG ACT
|
|||
|
:O D 112.0
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 132
|
|||
|
M001 :
|
|||
|
:A -MA17.0 TARNG/CALMNG ACT
|
|||
|
:S D 112.0
|
|||
|
:
|
|||
|
:AN -ME13.5 REL.FOR REGISTR.
|
|||
|
:JC =M002
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 134
|
|||
|
M002 :
|
|||
|
:L FD 200
|
|||
|
:T DD 130
|
|||
|
:
|
|||
|
:L DD 132
|
|||
|
:L DD 130
|
|||
|
:+G
|
|||
|
:T DD 134
|
|||
|
:***
|
|||
|
|
|||
|
F 17.0 = MA17.0 TARNG/CALMNG ACT plc scale AST 2
|
|||
|
F 13.5 = ME13.5 REL.FOR REGISTR. plc scale EST 2
|
|||
|
|
|||
|
Segment 21
|
|||
|
:
|
|||
|
:
|
|||
|
:
|
|||
|
:***
|
|||
|
FB 41 -FB41 HO580 SCALE4:BD560 C:ZONE10ST.S5D LEN=421
|
|||
|
Page 8
|
|||
|
Segment 22
|
|||
|
:A -MA16.4 DISCHARGE
|
|||
|
:AN -ME26.7 CONTAINER OK
|
|||
|
:= -ME10.0 RELEASE DISCHARG
|
|||
|
:
|
|||
|
:A -MA16.3 TAKEOV.WEIGHT VA
|
|||
|
:= -ME10.5 GOT WEIGHT VALUE
|
|||
|
:
|
|||
|
:O -MA16.6 FIN.DISCHARG.FIN
|
|||
|
:O -MA16.7 INT.DISCHARG.FIN
|
|||
|
:= -ME10.1 SCALE DISCHARGED
|
|||
|
:
|
|||
|
:AN -ME10.1 SCALE DISCHARGED
|
|||
|
:JC =M001
|
|||
|
:L KF +0
|
|||
|
:T DW 50
|
|||
|
:T DW 51
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 16.4 = MA16.4 DISCHARGE plc scale AST 2
|
|||
|
F 26.7 = ME26.7 CONTAINER OK
|
|||
|
F 10.0 = ME10.0 RELEASE DISCHARG plc scale EST 1
|
|||
|
F 16.3 = MA16.3 TAKEOV.WEIGHT VA plc scale AST 2
|
|||
|
F 10.5 = ME10.5 GOT WEIGHT VALUE plc scale EST 1
|
|||
|
F 16.6 = MA16.6 FIN.DISCHARG.FIN plc scale AST 2
|
|||
|
F 16.7 = MA16.7 INT.DISCHARG.FIN plc scale AST 2
|
|||
|
F 10.1 = ME10.1 SCALE DISCHARGED plc scale EST 1
|
|||
|
|
|||
|
Segment 23
|
|||
|
:ON -ME10.0 RELEASE DISCHARG
|
|||
|
:ON -MA16.5 FINAL DISCHARGE
|
|||
|
:JC =M001
|
|||
|
:A -M 19.4 GOT_DIS_STRT WEI
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 138
|
|||
|
:A -M 0.1 CONSTANT 1
|
|||
|
:S -M 19.4 GOT_DIS_STRT WEI
|
|||
|
M001 :
|
|||
|
:AN -ME10.1 SCALE DISCHARGED
|
|||
|
:JC =M002
|
|||
|
:
|
|||
|
:L FD 190
|
|||
|
:T DD 140
|
|||
|
M002 :
|
|||
|
:A -ME10.5 GOT WEIGHT VALUE
|
|||
|
:R -M 19.4 GOT_DIS_STRT WEI
|
|||
|
:***
|
|||
|
|
|||
|
F 10.0 = ME10.0 RELEASE DISCHARG plc scale EST 1
|
|||
|
F 16.5 = MA16.5 FINAL DISCHARGE plc scale AST 2
|
|||
|
F 19.4 = M 19.4 GOT_DIS_STRT WEI
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 10.1 = ME10.1 SCALE DISCHARGED plc scale EST 1
|
|||
|
F 10.5 = ME10.5 GOT WEIGHT VALUE plc scale EST 1
|
|||
|
|
|||
|
Segment 24
|
|||
|
:L DD 142
|
|||
|
:T DD 136
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 41 -FB41 HO580 SCALE4:BD560 C:ZONE10ST.S5D LEN=421
|
|||
|
Page 9
|
|||
|
Segment 25
|
|||
|
:L =CPSI
|
|||
|
:L KF +40
|
|||
|
:>=F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KG +0000000+00
|
|||
|
:T DD 130
|
|||
|
:T DD 132
|
|||
|
:T DD 134
|
|||
|
:
|
|||
|
:A -M 0.1 CONSTANT 1
|
|||
|
:R D 112.0
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
|
|||
|
Segment 26
|
|||
|
:L =DPSI
|
|||
|
:L KF +40
|
|||
|
:>=F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KG +0000000+00
|
|||
|
:T DD 136
|
|||
|
:T DD 138
|
|||
|
:T DD 140
|
|||
|
:T DD 142
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 27
|
|||
|
:A -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:AN -M 19.1 CONTROL FINE
|
|||
|
:O -MA14.0 NEGATIVE COURSE
|
|||
|
:O -MA15.0 POSITIVE COURSE
|
|||
|
:= -M 90.0 COARSE_SPEED
|
|||
|
:
|
|||
|
:O -M 19.1 CONTROL FINE
|
|||
|
:O -MA14.1 NEGATIVE FINE
|
|||
|
:O -MA15.1 POSITIVE FINE
|
|||
|
:= -M 90.1 FINE_SPEED
|
|||
|
:
|
|||
|
:O -MA14.2 NEGATIVE EX-FINE
|
|||
|
:O -MA15.2 POSITIVE EX-FINE
|
|||
|
:= -M 90.2 EXTRAFINE_SPEED
|
|||
|
:
|
|||
|
:O -MA14.4 NEG.COMPO.ACTIVE
|
|||
|
:O -MA15.4 POS.COMPO.ACTIVE
|
|||
|
:O -MA15.6 CNTR.WEIGH.ACTIV
|
|||
|
:S D 112.7
|
|||
|
:A -MA16.4 DISCHARGE
|
|||
|
:R D 112.7
|
|||
|
:***
|
|||
|
|
|||
|
F 15.6 = MA15.6 CNTR.WEIGH.ACTIV plc scale AST 1
|
|||
|
F 19.1 = M 19.1 CONTROL FINE
|
|||
|
F 14.0 = MA14.0 NEGATIVE COURSE plc scale AST 1
|
|||
|
F 15.0 = MA15.0 POSITIVE COURSE plc scale AST 1
|
|||
|
F 90.0 = M 90.0 COARSE_SPEED
|
|||
|
F 14.1 = MA14.1 NEGATIVE FINE plc scale AST 1
|
|||
|
F 15.1 = MA15.1 POSITIVE FINE plc scale AST 1
|
|||
|
F 90.1 = M 90.1 FINE_SPEED
|
|||
|
F 14.2 = MA14.2 NEGATIVE EX-FINE plc scale AST 1
|
|||
|
FB 41 -FB41 HO580 SCALE4:BD560 C:ZONE10ST.S5D LEN=421
|
|||
|
Page 10
|
|||
|
F 15.2 = MA15.2 POSITIVE EX-FINE plc scale AST 1
|
|||
|
F 90.2 = M 90.2 EXTRAFINE_SPEED
|
|||
|
F 14.4 = MA14.4 NEG.COMPO.ACTIVE plc scale AST 1
|
|||
|
F 15.4 = MA15.4 POS.COMPO.ACTIVE plc scale AST 1
|
|||
|
F 16.4 = MA16.4 DISCHARGE plc scale AST 2
|
|||
|
|
|||
|
Segment 28
|
|||
|
|
|||
|
:L -MW 10 I-CONTROLBITs
|
|||
|
:T DW 6
|
|||
|
:L -MW 12 I-CONTROLBITs
|
|||
|
:T DW 7
|
|||
|
:L -MW 14 O-CONTROLBITs
|
|||
|
:T DW 52
|
|||
|
:L -MW 16 O-CONTROLBITs
|
|||
|
:T DW 53
|
|||
|
:
|
|||
|
:L -MW24 IND. OUTPUTS SCALE
|
|||
|
:T DW 115
|
|||
|
:L -MW26 IND. INPUTS SCALE
|
|||
|
:T DW 116
|
|||
|
:L -MW30 IND. INPUTS WAY
|
|||
|
:T FW 117
|
|||
|
:L -MW30 IND. INPUTS WAY
|
|||
|
:T DW 118
|
|||
|
:
|
|||
|
:***
|
|||
|
|
|||
|
FW 10 = MW 10 I-CONTROLBITs plc scale EST 1
|
|||
|
FW 12 = MW 12 I-CONTROLBITs plc scale EST 2
|
|||
|
FW 14 = MW 14 O-CONTROLBITs plc scale AST 1
|
|||
|
FW 16 = MW 16 O-CONTROLBITs plc scale AST 2
|
|||
|
FW 24 = MW24 IND. OUTPUTS SCALE
|
|||
|
FW 26 = MW26 IND. INPUTS SCALE
|
|||
|
FW 30 = MW30 IND. INPUTS WAY
|
|||
|
|
|||
|
Segment 29
|
|||
|
|
|||
|
:L -MW18 STATUS FLAGS
|
|||
|
:T DW 114
|
|||
|
:
|
|||
|
:L -MB90 SIGNAL DISPLAY
|
|||
|
:T DR 119
|
|||
|
:BE
|
|||
|
|
|||
|
FW 18 = MW18 STATUS FLAGS SCALE STATUS
|
|||
|
FY 90 = MB90 SIGNAL DISPLAY SCALE SIGNAL DISPLAY
|
|||
|
|
|||
|
FB 90 -FB90 CHK_MULTIPORT_VALV C:ZONE10ST.S5D LEN=60
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
******************************************************************************
|
|||
|
BESCHREIBUNG :
|
|||
|
|
|||
|
Dieser Baustein dient zum ueberpruefen einer Ventilweiche
|
|||
|
Bei den angesteuerten Quetschventil muss die Zumeldung '0' sein
|
|||
|
Bei den nicht angesteuerten Quetschventilen muss die Zumeldung '1' sein
|
|||
|
|
|||
|
|
|||
|
******************************************************************************
|
|||
|
PARAMETER :
|
|||
|
|
|||
|
AWQV : Ausgangswort fuer Quetschventile ( Ansteuerung )
|
|||
|
EWQV : Eingangswort fuer Quetschventile ( Zumeldungen )
|
|||
|
FILT : Filter fuer Quetschventile
|
|||
|
TUMS : Timer Umschaltzeit
|
|||
|
QVOK : Quetschventile alle ok
|
|||
|
ANGE : Quetschventil angesteuert ( wenn 1 Ventil angesteuert )
|
|||
|
|
|||
|
******************************************************************************
|
|||
|
Name :CHECK-QV
|
|||
|
Decl :AWQV I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :EWQV I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :FILT I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KM
|
|||
|
Decl :TUMS I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :QVOK I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :ANGE I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2 QV ueberpruefen
|
|||
|
:L =TUMS Timer_NR fuer indirekte
|
|||
|
:T FW 204 Bearbeitung abspeichern
|
|||
|
:
|
|||
|
:L =AWQV
|
|||
|
:LW =FILT
|
|||
|
:AW
|
|||
|
:T FW 200
|
|||
|
:
|
|||
|
:L =EWQV
|
|||
|
:CFW
|
|||
|
:LW =FILT
|
|||
|
:AW
|
|||
|
:T FW 202
|
|||
|
:
|
|||
|
:L FW 200
|
|||
|
:L FW 202
|
|||
|
:!=F
|
|||
|
:L KT 005.2
|
|||
|
:DO FW 204
|
|||
|
:SD -T0 IND.ADDRES.(DUMMY) Umschaltzeit ausblenden
|
|||
|
:DO FW 204
|
|||
|
:A -T0 IND.ADDRES.(DUMMY)
|
|||
|
:= =QVOK
|
|||
|
:***
|
|||
|
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
|
|||
|
Segment 3 Quetschventil angesteuert
|
|||
|
:L FW 200
|
|||
|
:L KM 00000000 00000000
|
|||
|
:><F
|
|||
|
:= =ANGE
|
|||
|
FB 90 -FB90 CHK_MULTIPORT_VALV C:ZONE10ST.S5D LEN=60
|
|||
|
Page 2
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 91 -FB91 OCCUPY_SILO C:ZONE10ST.S5D LEN=78
|
|||
|
Page 1
|
|||
|
Segment 1 Kopplung Silo <-> Waage
|
|||
|
|
|||
|
******************************************************************************
|
|||
|
BESCHREIBUNG :
|
|||
|
|
|||
|
Mit der Dosieranforderung der akt_Waage ueberprueft dieser Baustein
|
|||
|
anhand der akt_Silo_Nr , ob das entsprechende Silo von einer anderen
|
|||
|
Waage belegt ist.
|
|||
|
Wenn das Silo nicht belegt ist ,wird dieses Silo mit der akt_Waage
|
|||
|
belegt.
|
|||
|
Sobald die Dosierung aus diesem Silo abeschlossen ist , wird
|
|||
|
die Belegung dieses Silos wieder geloescht.
|
|||
|
|
|||
|
|
|||
|
******************************************************************************
|
|||
|
PARAMETER :
|
|||
|
|
|||
|
SIN1 : Silonummer von Waage
|
|||
|
SIN2 : Uebernommene Silonummer
|
|||
|
WZNR : Wagenzaehlnummer
|
|||
|
DOSI : Dosieranforderung an Silo
|
|||
|
BELG : Rueckmeldung Silo mit aktueller Waage belegt
|
|||
|
NROK : Silonummer OK
|
|||
|
OFFS : Offset zur Silonummer
|
|||
|
|
|||
|
|
|||
|
******************************************************************************
|
|||
|
Name :SILO-BEL
|
|||
|
Decl :SINR I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :WADB I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :DOSI I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :BELG I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :SIOK I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :OFFS I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :SIAW I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :SIEW I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2 Silo belgt zyklisch loeschen
|
|||
|
:A =BELG
|
|||
|
:RB =BELG
|
|||
|
:
|
|||
|
:L KM 00000000 00000000
|
|||
|
:T =SIAW
|
|||
|
:T =SIEW
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 3 Silo mit akt_Waage belegen
|
|||
|
:AN =SIOK
|
|||
|
:JC =M001
|
|||
|
:L =SINR
|
|||
|
:LW =OFFS
|
|||
|
:+F
|
|||
|
:T FW 200
|
|||
|
:DO FW 200 Objekt_DX von Silo oeffnen
|
|||
|
:CX -DX 0 SYSTEM PARAMETER Silobelegung
|
|||
|
: --------------------------------
|
|||
|
:L KF +0 Silo belegt ?
|
|||
|
:L DW 0
|
|||
|
:!=F
|
|||
|
:JC =M002 Wenn Silo nicht belegt !
|
|||
|
:L =WADB Silo mit akt_Waage belegt ?
|
|||
|
FB 91 -FB91 OCCUPY_SILO C:ZONE10ST.S5D LEN=78
|
|||
|
Page 2
|
|||
|
:><F
|
|||
|
:JC =M003
|
|||
|
M002 :AN =DOSI Wenn keine Doieranforderung von
|
|||
|
:JC =M004 der Waage ansteht wird die Silo
|
|||
|
: belegung geloescht
|
|||
|
: --------------------------------
|
|||
|
:L =WADB akt_Silo mit akt_Waage belegen
|
|||
|
:T DW 0
|
|||
|
:AN =BELG
|
|||
|
:= =BELG
|
|||
|
:JU =M003
|
|||
|
M004 :L KF +0
|
|||
|
:T DW 0
|
|||
|
M003 :L DW 1
|
|||
|
:T =SIAW
|
|||
|
:L DW 2
|
|||
|
:T =SIEW
|
|||
|
M001 :BE
|
|||
|
|
|||
|
|
|||
|
DX 0 = DX 0 SYSTEM PARAMETER
|
|||
|
|
|||
|
FB 92 -FB92 CONTROL_WEIGHING C:ZONE10ST.S5D LEN=122
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
Name :CTR-WEIG
|
|||
|
Decl :WZNR I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :TOLE I/Q/D/B/T/C: I BI/BY/W/D: D
|
|||
|
Decl :TTOL I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :EOCW I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :TFIN I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :CTRF I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :DOSI I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :DFIN I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
|
|||
|
:L =TTOL
|
|||
|
:T FW 202
|
|||
|
:L =TFIN
|
|||
|
:T FW 204
|
|||
|
:L =TOLE
|
|||
|
:T FD 206
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 2
|
|||
|
:L =WZNR
|
|||
|
:L KF +100
|
|||
|
:+F
|
|||
|
:T FW 200
|
|||
|
:DO FW 200
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 3
|
|||
|
:O(
|
|||
|
:L DD 225 01 fine value
|
|||
|
:L KG +0000000+00 01
|
|||
|
:!=G 01
|
|||
|
:) 01
|
|||
|
:ON =DFIN
|
|||
|
:= F 201.0 no fine feeding
|
|||
|
:
|
|||
|
: *o(
|
|||
|
: *u =ctrf
|
|||
|
: *un m201.0
|
|||
|
: *)
|
|||
|
: *o m201.0 no fine feeding
|
|||
|
:A(
|
|||
|
:L FD 206 01 tolerated range
|
|||
|
:GFD 01
|
|||
|
:L KF +0 01
|
|||
|
:!=F 01
|
|||
|
:) 01
|
|||
|
:A =DOSI
|
|||
|
:= F 200.0 no tol.check
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 4
|
|||
|
:L DD 208 set weight
|
|||
|
:L FD 206 tolerated range
|
|||
|
:-G
|
|||
|
:L DD 200 actual total net weight
|
|||
|
:<G set wght - tol < act wght
|
|||
|
: *U(
|
|||
|
FB 92 -FB92 CONTROL_WEIGHING C:ZONE10ST.S5D LEN=122
|
|||
|
Page 2
|
|||
|
: *L dd208 set weight
|
|||
|
: *L dd206 tolerated range
|
|||
|
: *+G
|
|||
|
: *L dd200 actual total net weight
|
|||
|
: *>G set wght + tol > act wght
|
|||
|
: *) set -tol <act wght< set + tol
|
|||
|
:A =DOSI
|
|||
|
:L KT 003.2
|
|||
|
:DO FW 202
|
|||
|
:SD -T0 IND.ADDRES.(DUMMY)
|
|||
|
:DO FW 202
|
|||
|
:O -T0 IND.ADDRES.(DUMMY)
|
|||
|
:O F 200.0 no tol.check
|
|||
|
:S =EOCW
|
|||
|
:AN =DOSI
|
|||
|
:RB =EOCW
|
|||
|
:***
|
|||
|
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
|
|||
|
Segment 5
|
|||
|
:L DD 208 set weight
|
|||
|
:L DD 221 heel
|
|||
|
:-G
|
|||
|
:L DD 225 fine value
|
|||
|
:-G
|
|||
|
:L DD 200 actual total net weight
|
|||
|
:<G set wght- heel- fine < act wght
|
|||
|
:A(
|
|||
|
:L DD 225 01 fine value
|
|||
|
:L KG +0000000+00 01
|
|||
|
:>G 01
|
|||
|
:) 01
|
|||
|
:L KT 002.2
|
|||
|
:DO FW 204
|
|||
|
:SD -T0 IND.ADDRES.(DUMMY)
|
|||
|
:DO FW 204
|
|||
|
:A -T0 IND.ADDRES.(DUMMY)
|
|||
|
:A =DOSI
|
|||
|
:A =DFIN
|
|||
|
:= =CTRF
|
|||
|
:BE
|
|||
|
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
|
|||
|
FB 100 -FB100 COLLECTIVE FAULT C:ZONE10ST.S5D LEN=295
|
|||
|
Page 1
|
|||
|
Segment 1 Fehlererstwertmeldung
|
|||
|
|
|||
|
FB 99 Sammelstoerung und Fehler-Erstwertmeldung
|
|||
|
===============================================================================
|
|||
|
ERSTELLT : 17.11.92 HERKERT
|
|||
|
|
|||
|
AENDERUNGEN DATUM BEARBEITER
|
|||
|
-------------------------------------------------------------------------------
|
|||
|
Erweiterung fuer sequenziellen Ausdruck der Stoerungen 19.11.93 URBAN
|
|||
|
ueber Suetron BT20 Terminal
|
|||
|
-------------------------------------------------------------------------------
|
|||
|
Meldung einer Aenderung im Datenbaustein an Leitsystem:
|
|||
|
1. Aenderung an Leitsystem melden
|
|||
|
2. Leitsystem quittiert
|
|||
|
3. Leitsystem holt Stoerungen ab 13.12.93 Herkert
|
|||
|
===============================================================================
|
|||
|
SYMBOLIKDATEI :
|
|||
|
|
|||
|
BAUSTEINPARAMETER :
|
|||
|
-------------------
|
|||
|
# SAST: Sammelstoerung
|
|||
|
# QUIT: Quittierung Erstwertmeldung
|
|||
|
# ANFW: Anfangswort im Stoerdatenbaustein
|
|||
|
# ENDW: Endwort im Stoerdatenbaustein
|
|||
|
# DB1 : Stoer - DB
|
|||
|
# DB2 : Arbeits-DB erforderliche Laenge: 255 Datenworte
|
|||
|
# BER : AnlagenBereich ( Nummer eines Bereiches im Stoerdatenbaustein )
|
|||
|
# ERST: Erstwertmeldung
|
|||
|
# AUTQ: 1 = automatisch Quittierung durch das Programm selbst
|
|||
|
0 = Fehlerquittierung durch ein Leitsystem
|
|||
|
# T-NR: Suetron BT20 Terminal Nummer
|
|||
|
# AEND: Es wurde eine Aenderung im Stoerungsbild festgestellt
|
|||
|
(Stoerung gekommen oder gegangen)
|
|||
|
Meldung an Leitsystem
|
|||
|
^ QAEN: Quittierung der Aenderung vom Leitsystem
|
|||
|
# TOFF: Terminal-Offset (230) hkt (17.04.96)
|
|||
|
|
|||
|
|
|||
|
LOKALE VARIABLEN :
|
|||
|
------------------
|
|||
|
MW 200 :
|
|||
|
MW 202 :
|
|||
|
MW 242 :
|
|||
|
MW 244 :
|
|||
|
MW 246 :
|
|||
|
MW 248 :
|
|||
|
MW 252 :
|
|||
|
|
|||
|
|
|||
|
FUNKTION :
|
|||
|
----------
|
|||
|
Aufbau Stoerdatenbaustein #DB1
|
|||
|
===============================
|
|||
|
DW 0 - 63 : Stoerungen an Leitsystem
|
|||
|
DW 64 - 127 : Diskrepanzen zwischen E und A
|
|||
|
DW 128 - 191 : Erstwertmeldung
|
|||
|
DW 192 - 255 : Fehlerquittung von Leitsystem fuer jedes einzelne Bit
|
|||
|
|
|||
|
Aufbau Hilfsdatenbaustein #DB2:
|
|||
|
================================
|
|||
|
DW 0 Zeiger auf Stoer-DW 0-63 Bereich 0 fuer Stoerauswertung
|
|||
|
DW 1 Statusbitleiste 0 fuer Stoerauswertung
|
|||
|
|
|||
|
DW 2 Zeiger auf Stoer-DW 0-63 Bereich 1 fuer Stoerauswertung
|
|||
|
FB 100 -FB100 COLLECTIVE FAULT C:ZONE10ST.S5D LEN=295
|
|||
|
Page 2
|
|||
|
DW 3 Statusbitleiste 1 fuer Stoerauswertung
|
|||
|
..
|
|||
|
..
|
|||
|
DW 127 Statusbitleiste Bereich 64 fuer Stoerauswertung
|
|||
|
|
|||
|
DW 128 Zeiger auf Stoer-DW 0-63 Bereich 0 fuer Stoerausdruck auf BT20
|
|||
|
DW 129 Statusbitleiste 0 fuer Stoerausdruck auf BT20
|
|||
|
|
|||
|
DW 130 Zeiger auf Stoer-DW 0-63 Bereich 1 fuer Stoerausdruck auf BT20
|
|||
|
DW 131 Statusbitleiste 1 fuer Stoerausdruck auf BT20
|
|||
|
..
|
|||
|
..
|
|||
|
DW 255 Statusbitleiste 64 fuer Stoerausdruck auf BT20
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Ist die Anlage in verschiedene Stoerbereiche aufgeteilt muss im Parameter #BER
|
|||
|
die Bereichsnummer eingetragen werden.
|
|||
|
|
|||
|
Ueber ANFW und ENDW wird ein Bereich im Stoerdatenbaustein angegeben,
|
|||
|
der ueberwacht werden soll. Tritt eine neue Stoerung auf wird #ERST = '1'.
|
|||
|
Die Erstwertmeldung kann ueber die Quittierung #QUIT quittiert werden.
|
|||
|
|
|||
|
Solange in dem zu ueberwachenden Bereich eine Stoerung vorhanden ist,
|
|||
|
ist #SAST = '1'
|
|||
|
|
|||
|
Werden die Stoerungen nicht ueber ein Leitsystem (z.B. PC, BT20) quittiert, so
|
|||
|
quittiert sich jede Stoerung selbst, wenn #AUTQ = '1' ist
|
|||
|
|
|||
|
Mit #T-NR muss die Nummer des BT20 Terminals angegeben werden ueber das die
|
|||
|
Fehler gedruckt werden sollen. Wenn Ausgedruckt werden soll muss #AUTQ='0'
|
|||
|
sein und beim Aufruf des FB101 darf ebenfalls keine automatische Quittierung
|
|||
|
eingestellt sein
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Name :FE-ERSTW
|
|||
|
Decl :SAST I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :QUIT I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :ANFW I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :ENDW I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :DB1 I/Q/D/B/T/C: B
|
|||
|
Decl :DB2 I/Q/D/B/T/C: B
|
|||
|
Decl :BER I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :ERST I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :AUTQ I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :T-NR I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :AEND I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :QAEN I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :TOFF I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
|
|||
|
:A =QUIT
|
|||
|
:RB =ERST
|
|||
|
:
|
|||
|
:A =QAEN
|
|||
|
:RB =AEND
|
|||
|
:
|
|||
|
:L KF +63 Fehlerauswertung nicht freigeg.
|
|||
|
:LW =BER 63 = Maximale Bereichsnummer
|
|||
|
:<F Nummer des Anlagenbereiches
|
|||
|
:BEC
|
|||
|
:SLW 1
|
|||
|
:T FW 200 Bereich * 2
|
|||
|
:I 1
|
|||
|
FB 100 -FB100 COLLECTIVE FAULT C:ZONE10ST.S5D LEN=295
|
|||
|
Page 3
|
|||
|
:T FW 202
|
|||
|
:
|
|||
|
:DO =DB2
|
|||
|
:DO FW 200 DB2 = Arbeits DB Sammelstoerung
|
|||
|
:L DW 0
|
|||
|
:T FW 242
|
|||
|
: MW242 = Zeiger DW 0 - DW 63
|
|||
|
:DO FW 202
|
|||
|
:L DW 0
|
|||
|
:T FW 246 MW246 = Statusbitleiste
|
|||
|
: M246.0 = Stoerung Vorhanden
|
|||
|
:DO =DB1
|
|||
|
: DB1 = Stoerdatenbaustein
|
|||
|
:LW =ENDW
|
|||
|
:L FW 242 Bereichsende erreicht ?
|
|||
|
:I 1 MW242 = Zeiger im Bereich
|
|||
|
:>=F
|
|||
|
:JC =M001
|
|||
|
:L FW 246
|
|||
|
:A F 246.0
|
|||
|
:= =SAST M246.0 = Stoerung im Bereich
|
|||
|
:A F 246.0 Bereichssammelstoerung ausgeben
|
|||
|
:R F 246.0 Stoerungsbit fuer naechsten
|
|||
|
: Durchlauf ruecksetzen
|
|||
|
:
|
|||
|
:A F 246.2 Aenderung festgestellt
|
|||
|
:AN =AEND
|
|||
|
:AN =QAEN
|
|||
|
:S =AEND
|
|||
|
:R F 246.2
|
|||
|
:
|
|||
|
:
|
|||
|
:LW =ANFW
|
|||
|
M001 :T FW 242 Zeiger auf Bereichsanfang setzen
|
|||
|
:I 128 MW242 = Zeiger auf Stoerungen
|
|||
|
:T FW 244
|
|||
|
:I 64
|
|||
|
:T FW 248
|
|||
|
:
|
|||
|
:DO FW 244
|
|||
|
:L DW 0 MW244=Zeiger auf Erstwertmeldung
|
|||
|
: alte Stoerungen laden
|
|||
|
:DO FW 242
|
|||
|
:L DW 0 MW242=Zeiger auf Stoerungen
|
|||
|
:T FW 250 neue Stoerungen laden
|
|||
|
:
|
|||
|
:DO FW 244
|
|||
|
:T DW 0
|
|||
|
:TAK neue Stoer.->Erstwertspeicher
|
|||
|
:XOW
|
|||
|
:T FW 252 MW252 = Diskrepanz Alt/Neu
|
|||
|
:AW Diskrepanz zwischen alt u. neu
|
|||
|
:L KF +0
|
|||
|
:><F und neu = 1 dann Erstwertmeldung
|
|||
|
:S =ERST
|
|||
|
:L FW 252
|
|||
|
:><F
|
|||
|
:S F 246.2 M 246.2 = Aenderung aufgetreten
|
|||
|
:
|
|||
|
:A =QUIT
|
|||
|
:AN F 246.1
|
|||
|
:RB =ERST mit der positiven Flanke der
|
|||
|
:A =QUIT Quittiertaste wird die
|
|||
|
:= F 246.1 Erstwertmeldung zurueckgesetzt
|
|||
|
FB 100 -FB100 COLLECTIVE FAULT C:ZONE10ST.S5D LEN=295
|
|||
|
Page 4
|
|||
|
:
|
|||
|
:L FW 250
|
|||
|
:L KF +0
|
|||
|
:><F aktuelles Stoerdatenwort
|
|||
|
:S F 246.0
|
|||
|
:S =SAST Stoerung vorhanden ?
|
|||
|
: M 246.0 = im Anlagenbereich
|
|||
|
:DO =DB2 ist eine Stoerung vorhanden
|
|||
|
:L FW 242
|
|||
|
:DO FW 200
|
|||
|
:T DW 0 Zeiger auf Stoerungen im
|
|||
|
:
|
|||
|
: zweiten DB sichern
|
|||
|
:L FW 246
|
|||
|
:DO FW 202
|
|||
|
:T DW 0 MW246 = Statuswort
|
|||
|
:
|
|||
|
:AN =SAST Statuswort sichern
|
|||
|
:RB =ERST
|
|||
|
:*** wenn kein Fehler mehr vorhanden
|
|||
|
|
|||
|
|
|||
|
Segment 2 Stoerungsblock in Quittungsblock
|
|||
|
:AN =AUTQ wenn keine Quittung vom PLS
|
|||
|
:JC =M001 dann automatische Quittung
|
|||
|
:DO =DB1
|
|||
|
:DO FW 242 MW242 = Zeiger auf DW 0-63
|
|||
|
:L DW 0 Stoerungen laden
|
|||
|
:
|
|||
|
:DO FW 248 MW248 = Zeiger auf DW192-255
|
|||
|
:T DW 0 Stoerung -> Quittung
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 3 STOERUNGEN DRUCKEN UEBER BT20
|
|||
|
:LW =T-NR WENN KEINE TERMINAL NUMMER
|
|||
|
:L KF +0 EINGETRAGEN IST
|
|||
|
:!=F
|
|||
|
:BEC -> REST NICHT BEARBEITEN
|
|||
|
:
|
|||
|
:LW =TOFF OFFSET FUER DATENBAUSTEIN BT20
|
|||
|
:LW =T-NR TERMINAL NUMMER
|
|||
|
:+F
|
|||
|
:T FW 204
|
|||
|
:DO FW 204
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:L DW 2 SEQUENTIELLER MELDEBEREICH ZU BT
|
|||
|
:L KF +0 WENN MELDUNG NICHT QUITTIERT
|
|||
|
:><F
|
|||
|
:BEC -> REST NICHT BEARBEITEN
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 4 MERKER VORBELEGEN
|
|||
|
:LW =BER
|
|||
|
:SLW 1 BEREICH * 2
|
|||
|
:L KF +128 OFFSET +128
|
|||
|
:+F
|
|||
|
:T FW 200 ZEIGER AUF AKTUELLEN BEREICH DW1
|
|||
|
:I 1
|
|||
|
:T FW 202 ZEIGER AUF AKTUELLEN BEREICH DW2
|
|||
|
FB 100 -FB100 COLLECTIVE FAULT C:ZONE10ST.S5D LEN=295
|
|||
|
Page 5
|
|||
|
:
|
|||
|
:DO =DB2 ARBEITS DB SAMMELSTOERUNG
|
|||
|
:DO FW 200
|
|||
|
:L DW 0
|
|||
|
:T FW 242 AKTUELLES DATENWORT
|
|||
|
:DO FW 202
|
|||
|
:L DR 0
|
|||
|
:T FW 244 AKTUELLES DATENBIT
|
|||
|
:DO FW 202
|
|||
|
:L DL 0
|
|||
|
:T FY 246 AKTUELLER STATUS
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 5
|
|||
|
|
|||
|
:DO =DB1 STOERDATENBAUSTEIN
|
|||
|
:
|
|||
|
:L FW 244 WENN AKTUELLER FEHLER NULL
|
|||
|
:L KF +16 DANN MIT 1 VORBELEGEN
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:L KF +0
|
|||
|
:T FW 244
|
|||
|
:
|
|||
|
:L FW 242 ZEIGER AUF NAECHSTES DATENWORT
|
|||
|
:I 1 SETZEN
|
|||
|
:T FW 242
|
|||
|
:LW =ENDW
|
|||
|
:<=F
|
|||
|
:JC =M001
|
|||
|
:LW =ANFW ZEIGER AUF ERSTES DATENWORT
|
|||
|
:T FW 242 SETZEN
|
|||
|
M001 :L KM 00000000 00000001
|
|||
|
:DO FW 244
|
|||
|
:SLW 0 AKTUELLES BIT
|
|||
|
:DO FW 242 ZEIGER AUF AKT.FEHLERWORT
|
|||
|
:L DW 0 AKTUELLES FEHLERWORT
|
|||
|
:AW
|
|||
|
:L KF +0
|
|||
|
:!=F KEIN FEHLER VORHANDEN
|
|||
|
:JC =M002 -> NAECHSTES BIT
|
|||
|
:
|
|||
|
:L FW 242 AKT. FEHLERWORT
|
|||
|
:L KF +192 OFFSET AUF DATENWORT 192
|
|||
|
:+F
|
|||
|
:T FW 248 AKT. FEHLERWORT QUITTIERUNG
|
|||
|
:L KM 00000000 00000001
|
|||
|
:DO FW 244
|
|||
|
:SLW 0
|
|||
|
:DO FW 248
|
|||
|
:L DW 0 FEHLER QUITTIERUNG
|
|||
|
:AW
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:JC =M002 FEHLER SCHON QUITTIERT/GEDRUCKT
|
|||
|
:
|
|||
|
:AN F 246.0 FEHLER NOCH NICHT GESENDET
|
|||
|
:JC =M003
|
|||
|
:L KM 00000000 00000001
|
|||
|
:DO FW 244
|
|||
|
:SLW 0 AKTUELLER FEHLER
|
|||
|
:DO FW 248
|
|||
|
:L DW 0 AKTUELLE FEHLERQUITTIERUNG
|
|||
|
FB 100 -FB100 COLLECTIVE FAULT C:ZONE10ST.S5D LEN=295
|
|||
|
Page 6
|
|||
|
:OW
|
|||
|
:DO FW 248
|
|||
|
:T DW 0 AKTUELLE FEHLERQUITT. SPEICHERN
|
|||
|
:
|
|||
|
:A F 246.0 FEHLER GESENDET ZURUECKSETZEN
|
|||
|
:R F 246.0
|
|||
|
:JU =M002
|
|||
|
:
|
|||
|
M003 :LW =TOFF OFFSET FUER DATENBAUSTEIN BT20
|
|||
|
:LW =T-NR TERMINAL NUMMER
|
|||
|
:+F
|
|||
|
:T FW 204 AKTUELLER TERMINAL ARBEITS DB
|
|||
|
:DO FW 204
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY) DB LADEN
|
|||
|
:
|
|||
|
:L FW 242
|
|||
|
:SLW 4 * 16
|
|||
|
:L FW 244
|
|||
|
:+F
|
|||
|
:I 1
|
|||
|
:T DW 2 FEHLERNUMMER SCHREIBEN
|
|||
|
:
|
|||
|
:AN F 246.0
|
|||
|
:S F 246.0 FEHLER GESENDET
|
|||
|
:JU =M004
|
|||
|
:
|
|||
|
M002 :DO =DB2
|
|||
|
:L FW 242 AKTUELLES DATENWORT
|
|||
|
:DO FW 200
|
|||
|
:T DW 0
|
|||
|
:
|
|||
|
:L FW 244 AKTUELLES DATENBIT
|
|||
|
:I 1
|
|||
|
:T FW 244
|
|||
|
:DO FW 202
|
|||
|
:T DR 0
|
|||
|
:
|
|||
|
M004 :DO =DB2
|
|||
|
:L FY 246 AKTUELLER STATUS
|
|||
|
:DO FW 202
|
|||
|
:T DL 0
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
FB 101 -FB101 FAULT RW/KL/MO/Q C:ZONE10ST.S5D LEN=457
|
|||
|
Page 1
|
|||
|
Segment 1 Stoerauswertung RW/KL/MO/QV/BI
|
|||
|
|
|||
|
FB 101 STOERAUSWERTUNG STAND : 26.08.97
|
|||
|
===============================================================================
|
|||
|
***** CPU : ALLE CPU'S *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : XX.XX.XX WEGERT
|
|||
|
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG :
|
|||
|
|
|||
|
NR. DATUM AENDERUNG BEARBEITER
|
|||
|
-------------------------------------------------------------------------------
|
|||
|
01 01.11.92 ERWEITERUNG DER FUNKTION DURCH FEHLERQUITTUNG HKT
|
|||
|
VOM LEITSYSTEM
|
|||
|
02 01.07.93 PARAMETRIERBARKEIT VERSCHIEDENER HKT
|
|||
|
TYPEN ( RW,KL, ETC.)
|
|||
|
03 14.10.93 ERWEITERUNG TYP FU, BN HKT
|
|||
|
04 13.11.96 N14 (1) UR
|
|||
|
05 25.04.97 ERWEITERUNG TYP DV SRA
|
|||
|
06 26.08.97 ERWEITERUNG DER STOERMELDUNG SRA
|
|||
|
===============================================================================
|
|||
|
SYMBOLIKDATEI : FB101@Z0.SEQ
|
|||
|
=============================
|
|||
|
|
|||
|
PARAMETER:
|
|||
|
==========
|
|||
|
1. TYP : KC RW = Rohrweiche
|
|||
|
KC KL = Klappe
|
|||
|
KC MO = Motor
|
|||
|
KC QV = Quetschventil
|
|||
|
KC BI = Bitleiste, die nur durchgereicht wird
|
|||
|
KC BN = Bitleist negativ HKT 14.10.93
|
|||
|
KC FU = Frequenzumformer WT 22.09.93
|
|||
|
KC IV = Impulsventil
|
|||
|
KC DV = Dosierventil (A grob/fein, E auf/zu) SRA 25.04.97
|
|||
|
|
|||
|
2. IMP : ZEITIMPULS _________-________________-____________
|
|||
|
1 ZYKLUS LANG 'HIGH'
|
|||
|
|
|||
|
3. AW1 : AUSGANGSWORT 1
|
|||
|
4. AW2 : AUSGANGSWORT 2
|
|||
|
5. EW1 : EINGANGSWORT 1 = positive Rueckmeldung
|
|||
|
6. EW2 : EINGANGSWORT 2 = negative Rueckmeldung
|
|||
|
7. FILT : FILTER
|
|||
|
8. DW1 : STOERDATENWORT 1
|
|||
|
9. DW2 : STOERDATENWORT 2
|
|||
|
10. FRG : FREIGABE
|
|||
|
11. QUIT : BITMUSTER KM 1 = quittiert sich selbst
|
|||
|
0 = Stoerung wird extern ( z.B. PC) quittiert
|
|||
|
12. ANZ : ANZAHL DER STOERMELDUNGEN
|
|||
|
13. STDB : STOERMELDE-DB
|
|||
|
14. SAST : SAMMELSTOERUNG
|
|||
|
15. AEND : AENDERUNG (NEUE STOERUNG)
|
|||
|
|
|||
|
ANZ = 1 ANZ = 2
|
|||
|
TYP AW1 AW2 EW1 EW2 DW1 DW1 DW2
|
|||
|
----------------------------------------------------------------------------
|
|||
|
RW Y1_A Y2_B S1_A S2_B DW1 DW1_A DW2_B
|
|||
|
KL Y1_auf - S_auf S_zu DW1 DW_n.auf DW_n.zu
|
|||
|
MO M1 - K1 - DW1 DW1 -
|
|||
|
QV Y1_auf - - S_zu DW1 DW_n.auf DW_n.zu
|
|||
|
FB 101 -FB101 FAULT RW/KL/MO/Q C:ZONE10ST.S5D LEN=457
|
|||
|
Page 2
|
|||
|
BI Bitleiste - DW1
|
|||
|
BN Bitleist neg. DW1
|
|||
|
FU Freigabe - Betrieb - DW1
|
|||
|
IV Impulsventil - Rueckmeld -
|
|||
|
DV Y1_grob Y2_fein S1_auf S2_zu DW1 DW_n.auf DW_n.zu
|
|||
|
|
|||
|
|
|||
|
AUFBAU DES STOERDATENBAUSTEINS:
|
|||
|
|
|||
|
BLOCK 1 : STOERUNGEN AN LEITSYSTEM
|
|||
|
BLOCK 2 : DISKREPANZEN ZWISCHEN E UND A
|
|||
|
BLOCK 3 : ERSTWERTMELDUNG
|
|||
|
BLOCK 4 : FEHLERQUITTUNG von Leitsystem fuer jedes einzelne Bit
|
|||
|
|
|||
|
|
|||
|
Beispiel fuer Signalverlauf:
|
|||
|
============================
|
|||
|
|
|||
|
Ausgang ___-------------------_______________________________________
|
|||
|
Eingang __________-------------------------------------______________
|
|||
|
A xor E ___-------____________-------------------------______________
|
|||
|
Imp _______-________-________-________-________-________-________
|
|||
|
Zw.speich._______---_______________----------------------______________
|
|||
|
Stoerung __________________________________-------------______________
|
|||
|
Quittung ___________________________________________----______________
|
|||
|
|
|||
|
|
|||
|
|
|||
|
FUNKTION DES BAUSTEINS:
|
|||
|
=======================
|
|||
|
|
|||
|
1. ZYKLISCHER VERGLEICH VON AUSGANGSWORT UND EINGANGSWORT
|
|||
|
UND ABSPEICHERN DER DISKREPANZ IN BLOCK 2
|
|||
|
|
|||
|
2. BILDUNG DER STOERUNGEN AUS AKTUELLER UND LETZTER DISKREPANZ
|
|||
|
|
|||
|
3. RUECKSETZEN DER STOERUNGEN, WENN KEINE DISKREPANZ ZWISCHEN E UND A
|
|||
|
UND EINE QUITTUNG VORLIEGT
|
|||
|
|
|||
|
|
|||
|
VERWENDETE MERKER:
|
|||
|
==================
|
|||
|
SIEHE SYMBOLIK
|
|||
|
|
|||
|
Name :STOERUNG
|
|||
|
Decl :TYP I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KS
|
|||
|
Decl :IMP I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :AW1 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :AW2 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :EW1 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :EW2 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :FILT I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KM
|
|||
|
Decl :DW1 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :DW2 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :FRG I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :QUIT I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KM
|
|||
|
Decl :ANZ I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :STDB I/Q/D/B/T/C: B
|
|||
|
Decl :SAST I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :AEND I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
|
|||
|
:L KH 0000
|
|||
|
:T FW 250 MW250 = Diskrepanz AW1
|
|||
|
:T FW 252 MW252 = Diskrepanz AW2
|
|||
|
FB 101 -FB101 FAULT RW/KL/MO/Q C:ZONE10ST.S5D LEN=457
|
|||
|
Page 3
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 2 Rohrweiche 2A / 2E
|
|||
|
|
|||
|
|
|||
|
:LW =TYP
|
|||
|
:L KS RW
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1 U A1
|
|||
|
:L =EW1 UN E1
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:L FW 250 MW250 = Diskrepanz AW1
|
|||
|
:OW
|
|||
|
:T FW 250
|
|||
|
:
|
|||
|
:L =AW2 U A2
|
|||
|
:L =EW2 UN E2
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:L FW 252 MW252 = Diskrepanz AW2
|
|||
|
:OW
|
|||
|
:T FW 252
|
|||
|
:
|
|||
|
:L =EW1 UN E1
|
|||
|
:CFW UN E2
|
|||
|
:L =EW2
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:L FW 250
|
|||
|
:OW
|
|||
|
:T FW 250
|
|||
|
:
|
|||
|
:L =EW1 U E1
|
|||
|
:L =EW2 U E2
|
|||
|
:AW
|
|||
|
:L FW 250
|
|||
|
:OW
|
|||
|
:T FW 250
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 3 Impulsventil
|
|||
|
:LW =TYP
|
|||
|
:L KS IV
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1 U A1
|
|||
|
:L =EW1 UN E1
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:T FW 250 MW250 = Diskrepanz
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 4 KLAPPE 1A / 2E
|
|||
|
|
|||
|
:LW =TYP
|
|||
|
FB 101 -FB101 FAULT RW/KL/MO/Q C:ZONE10ST.S5D LEN=457
|
|||
|
Page 4
|
|||
|
:L KS KL
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1
|
|||
|
:L =EW1
|
|||
|
:XOW
|
|||
|
:L FW 250
|
|||
|
:OW
|
|||
|
:T FW 250 KLappe geht nicht auf
|
|||
|
:
|
|||
|
:L =AW1
|
|||
|
:L =EW2
|
|||
|
:CFW
|
|||
|
:XOW
|
|||
|
:L FW 252
|
|||
|
:OW
|
|||
|
:T FW 252 Klappe geht nicht zu
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 5 MOTOR 1A / 1E
|
|||
|
:LW =TYP
|
|||
|
:L KS MO
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1 U A
|
|||
|
:L =EW1 UN E
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:L FW 250 Motor laeuft nicht an
|
|||
|
:OW
|
|||
|
:T FW 250
|
|||
|
:
|
|||
|
:L =AW1 UN A
|
|||
|
:CFW U E
|
|||
|
:L =EW1
|
|||
|
:AW
|
|||
|
:L FW 252
|
|||
|
:OW
|
|||
|
:T FW 252 Motor geht nicht aus
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 6 QUETSCHVENTIL 1 A / 1 E
|
|||
|
:LW =TYP
|
|||
|
:L KS QV
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1 U A auf
|
|||
|
:L =EW2 U E zu
|
|||
|
:AW
|
|||
|
:L FW 250
|
|||
|
:OW
|
|||
|
:T FW 250 Ventil geht nicht auf
|
|||
|
:
|
|||
|
:L =AW1 UN A auf
|
|||
|
:CFW
|
|||
|
:L =EW2 UN E zu
|
|||
|
:CFW
|
|||
|
FB 101 -FB101 FAULT RW/KL/MO/Q C:ZONE10ST.S5D LEN=457
|
|||
|
Page 5
|
|||
|
:AW
|
|||
|
:L FW 252
|
|||
|
:OW
|
|||
|
:T FW 252 Ventil geht nicht zu
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 7 FREQUENZUMFORMER
|
|||
|
|
|||
|
:LW =TYP 14.10.93 HKT
|
|||
|
:L KS FU
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1 U A Ansteuerung
|
|||
|
:L =EW1 UN E Betrieb
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:T FW 250 Keine Rueckmeldung bei
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 8 DOSIERVENTIL 2 A / 2 E
|
|||
|
|
|||
|
26.08.97 SRA - (1) ERWEITERUNG DER STOERMELDUNG
|
|||
|
|
|||
|
:LW =TYP 14.10.93 HKT
|
|||
|
:L KS DV
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1 U A grob
|
|||
|
:L =EW1 UN E auf
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:L FW 250
|
|||
|
:OW
|
|||
|
:T FW 250 Ventil geht nicht auf
|
|||
|
:
|
|||
|
:L =AW1 UN A grob
|
|||
|
:CFW
|
|||
|
:L =AW2 UN A fein
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:L =EW2 UN E zu
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:L FW 252
|
|||
|
:OW
|
|||
|
:T FW 252 Ventil geht nicht zu
|
|||
|
:
|
|||
|
:L =AW1 UN A grob (1)
|
|||
|
:CFW (1)
|
|||
|
:L =AW2 UN A fein (1)
|
|||
|
:CFW (1)
|
|||
|
:AW (1)
|
|||
|
:L =EW1 U E auf (1)
|
|||
|
:AW (1)
|
|||
|
:L FW 252 (1)
|
|||
|
:OW (1)
|
|||
|
:T FW 252 Ventil offen (1)
|
|||
|
M001 :***
|
|||
|
FB 101 -FB101 FAULT RW/KL/MO/Q C:ZONE10ST.S5D LEN=457
|
|||
|
Page 6
|
|||
|
Segment 9 STOERUNGS-BITLEISTE
|
|||
|
:LW =TYP
|
|||
|
:L KS BI
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1 #AW1 = Stoerbitleiste
|
|||
|
:T FW 250 MW250 = Diskrepanz AW1
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 10 STOERUNG NEGATIVE BITLEISTE
|
|||
|
:LW =TYP 14.10.93 HKT
|
|||
|
:L KS BN
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1
|
|||
|
:CFW
|
|||
|
:T FW 250 MW250 = Diskrepanz AW1
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 11 STOERAUSWERTUNG RW/KL/MO/QV
|
|||
|
:LW =DW1 #S-DW
|
|||
|
:T FW 230 MW230 ZEIGER AUF STOERDATENWORT
|
|||
|
:L KF +64 #OFFS ab DW 64 Zwischenspeicher
|
|||
|
:+F
|
|||
|
:T FW 232 MW232 ZEIG. ZWISCHENSPEICHER
|
|||
|
:
|
|||
|
:L FW 230
|
|||
|
:L KF +192 ab DW 192 Quittierung v. PC
|
|||
|
:+F
|
|||
|
:T FW 234 MW234 ZEIGER AUF QUITTIERUNG
|
|||
|
:
|
|||
|
:LW =ANZ 2 STOERMELDUNGEN JE ELEMENT ?
|
|||
|
:L KF +2
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:LW =DW2
|
|||
|
:T FW 240 MW240 ZEIGER AUF STOER-DW2
|
|||
|
:L KF +64
|
|||
|
:+F
|
|||
|
:T FW 242 MW242 ZEIGER AUF ZWISCHENSP.2
|
|||
|
:
|
|||
|
:L FW 240
|
|||
|
:L KF +192
|
|||
|
:+F
|
|||
|
:T FW 244 MW244 ZEIGER AUF QUITTUNG 2
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 12 STOER-DB
|
|||
|
:DO =STDB
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 13 STOERUNGSQUITTIERUNG
|
|||
|
:DO FW 230 MW230 = ZEIGER AUF STOER-DW
|
|||
|
:L DW 0
|
|||
|
FB 101 -FB101 FAULT RW/KL/MO/Q C:ZONE10ST.S5D LEN=457
|
|||
|
Page 7
|
|||
|
:LW =QUIT #QUIT
|
|||
|
:AW
|
|||
|
:T FW 236 MW236 = ZWISCHENSPEICHER
|
|||
|
:
|
|||
|
:DO FW 230 MW230 = ZEIGER AUF STOER-DW
|
|||
|
:L DW 0
|
|||
|
:DO FW 234 MW234 = ZEIGER AUF QUITTIERUNG
|
|||
|
:L DW 0
|
|||
|
:AW
|
|||
|
:L FW 236 MW236 = ZWISCHENSPEICHER
|
|||
|
:OW
|
|||
|
:DO FW 234 MW234 = ZEIGER AUF QUITTIERUNG
|
|||
|
:T DW 0
|
|||
|
:
|
|||
|
:LW =ANZ QUITTIERUNG #DW2
|
|||
|
:L KF +2
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:DO FW 240
|
|||
|
:L DW 0
|
|||
|
:LW =QUIT
|
|||
|
:AW
|
|||
|
:T FW 246
|
|||
|
:
|
|||
|
:DO FW 240
|
|||
|
:L DW 0
|
|||
|
:DO FW 244
|
|||
|
:L DW 0
|
|||
|
:AW
|
|||
|
:L FW 246
|
|||
|
:OW
|
|||
|
:DO FW 244
|
|||
|
:T DW 0
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 14 NUR EINE STOERUNG ANZEIGEN
|
|||
|
:LW =ANZ
|
|||
|
:L KF +1
|
|||
|
:>F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L FW 250
|
|||
|
:L FW 252
|
|||
|
:OW
|
|||
|
:T FW 250
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 15 STOERAUSWERTUNG
|
|||
|
|
|||
|
13.11.96 UR - (1) STOERUNGS AENDERUNG (#AEND) WIRD NUR BEI AENDERUNG
|
|||
|
GESETZT. FUNKTION VORHER FALSCH
|
|||
|
|
|||
|
|
|||
|
:A F 236.0 M236.0: 2.STOERW. N. BEARBEITET
|
|||
|
:R F 236.0
|
|||
|
:
|
|||
|
M005 :
|
|||
|
:LW =FILT FILTER
|
|||
|
:L FW 250 MW250 = NEUE DISKREPANZ
|
|||
|
FB 101 -FB101 FAULT RW/KL/MO/Q C:ZONE10ST.S5D LEN=457
|
|||
|
Page 8
|
|||
|
:AW
|
|||
|
:T FW 250 MW250 = NEUE DISKREPANZ
|
|||
|
:
|
|||
|
:AN =FRG #FRG
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:AN =IMP #IMP _____-______________-_____
|
|||
|
:JC =M002
|
|||
|
: Stoerung bilden:
|
|||
|
:DO FW 232 MW232 = ZEIG. ALTE DISKREPANZ
|
|||
|
:L DW 0
|
|||
|
:LW =FILT Filter -> Bits ausserhalb des
|
|||
|
:CFW Filters bleiben erhalten
|
|||
|
:AW
|
|||
|
:L FW 250 MW250 = NEUE DISKREPANZ
|
|||
|
:OW
|
|||
|
: ALTE DISKREPANZ LADEN
|
|||
|
:DO FW 232 MW232 = ZEIG. ALTE DISKREPANZ
|
|||
|
:L DW 0
|
|||
|
:TAK
|
|||
|
:DO FW 232 MW232 = ZEIG. ALTE DISKREPANZ
|
|||
|
:T DW 0 NEUE DISKREPANZ SPEICHERN
|
|||
|
:AW ALTE U. NEUE DISKREPANZ = STOER.
|
|||
|
:
|
|||
|
:LW =FILT
|
|||
|
:AW
|
|||
|
:
|
|||
|
:DO FW 230 MW230 = ZEIGER AUF STOERDW
|
|||
|
:L DW 0
|
|||
|
:T FW 238 MW238 = ZWISCHENSPEICHER (1)
|
|||
|
:OW
|
|||
|
:DO FW 230 MW230 = ZEIGER AUF STOERDATENWOR
|
|||
|
:T DW 0 STOERUNG SETZEN
|
|||
|
:L FW 238 MW238 = ZWISCHENSPEICHER (1)
|
|||
|
:><F (1)
|
|||
|
:S =AEND AENDERUNG STOERUNG SETZEN (1)
|
|||
|
:
|
|||
|
:JU =M003
|
|||
|
M002 :
|
|||
|
:DO FW 230
|
|||
|
:L DW 0
|
|||
|
:LW =FILT
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:T FW 254 MW254=Stoer.ausserhalb Filter
|
|||
|
:
|
|||
|
:DO FW 232 MW232 = ZEIG. ALTE DISKREPANZ
|
|||
|
:L DW 0
|
|||
|
:LW =FILT
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:L FW 250 MW250 = Diskrepanz
|
|||
|
:OW
|
|||
|
:DO FW 232 MW232 = ZEIG. ALTE DISKREPANZ
|
|||
|
:L DW 0
|
|||
|
:AW
|
|||
|
:DO FW 232 MW232 = ZEIG. ALTE DISKREPANZ
|
|||
|
:T DW 0
|
|||
|
:
|
|||
|
:DO FW 234 MW234 = Quittung PLS
|
|||
|
:L DW 0
|
|||
|
:TAK
|
|||
|
:XOW
|
|||
|
:AW
|
|||
|
FB 101 -FB101 FAULT RW/KL/MO/Q C:ZONE10ST.S5D LEN=457
|
|||
|
Page 9
|
|||
|
:
|
|||
|
:DO FW 230 MW230 = Stoerungen
|
|||
|
:L DW 0
|
|||
|
:TAK
|
|||
|
:XOW MW254=Stoer.ausserh.Filter
|
|||
|
:AW
|
|||
|
:L FW 254
|
|||
|
:OW
|
|||
|
:DO FW 230
|
|||
|
:T DW 0 MW230=ZEIGER AUF STOERUNGEN
|
|||
|
:
|
|||
|
:JU =M003
|
|||
|
M001 :L KF +0
|
|||
|
:DO FW 232
|
|||
|
:T DW 0 MW232 = Zeiger Zwischenspeicher
|
|||
|
M003 :
|
|||
|
:LW =ANZ
|
|||
|
:L KF +2
|
|||
|
:<F
|
|||
|
:O F 236.0 M236.0=ZWEITES STOERWORT FERTIG
|
|||
|
:JC =M004
|
|||
|
: ZEIGER FUER ZWEITES STOERWORT
|
|||
|
:L FW 252 MW252 = ZWEITE DISKREPANZ
|
|||
|
:T FW 250 MW250 = ERSTE DISKREPANZ
|
|||
|
:
|
|||
|
:L FW 240 MW240 = Stoerdatenwort
|
|||
|
:T FW 230 MW230 = Stoerdatenwort
|
|||
|
:
|
|||
|
:L FW 242
|
|||
|
:T FW 232 Zeiger auf Zwischenspeicher
|
|||
|
:
|
|||
|
:L FW 244
|
|||
|
:T FW 234
|
|||
|
:AN F 236.0
|
|||
|
:S F 236.0
|
|||
|
:JU =M005
|
|||
|
:
|
|||
|
M004 :***
|
|||
|
|
|||
|
|
|||
|
Segment 16 Sammelstoerung
|
|||
|
|
|||
|
|
|||
|
:DO FW 230 MW230 = Stoerungen
|
|||
|
:L DW 0
|
|||
|
:LW =FILT
|
|||
|
:AW
|
|||
|
:L KM 00000000 00000000
|
|||
|
:><F
|
|||
|
:S =SAST
|
|||
|
:
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 102 -FB102 FAULT INDIREKT C:ZONE10ST.S5D LEN=401
|
|||
|
Page 1
|
|||
|
Segment 1 Stoerauswertung RW/KL/MO/QV/BI
|
|||
|
|
|||
|
--------------------------------------------------------------------------
|
|||
|
Datum:
|
|||
|
erstellt: Wegert
|
|||
|
|
|||
|
Aenderungen:
|
|||
|
|
|||
|
Erweiterung der Funktion durch Herkert 1.11.92
|
|||
|
Fehlerquittung vom Leitsystem
|
|||
|
|
|||
|
Parametrierbarkeit verschiedener Herkert 01.07.93
|
|||
|
Typen ( RW,KL, etc.)
|
|||
|
|
|||
|
Erweiterung
|
|||
|
Typ : FU, BN Herkert 14.10.93
|
|||
|
--------------------------------------------------------------------------
|
|||
|
PARAMETER:
|
|||
|
==========
|
|||
|
|
|||
|
1. TYP : KC RW = Rohrweiche
|
|||
|
KC KL = Klappe
|
|||
|
KC MO = Motor
|
|||
|
KC QV = Quetschventil
|
|||
|
KC BI = Bitleiste, die nur durchgereicht wird
|
|||
|
KC BN = Bitleist negativ HKT 14.10.93
|
|||
|
KC FU = Frequenzumformer WT 22.09.93
|
|||
|
|
|||
|
2. IMP : ZEITIMPULS _________-________________-____________
|
|||
|
1 ZYKLUS LANG 'HIGH'
|
|||
|
|
|||
|
3. AW1 : AUSGANGSWORT 1
|
|||
|
4. AW2 : Ausgangswort 2
|
|||
|
5. EW1 : EINGANGSWORT 1 = positive Rueckmeldung
|
|||
|
6. EW2 : Eingangswort 2 = negative Rueckmeldung
|
|||
|
7. FILT : FILTER
|
|||
|
8. DW1 : Stoerdatenwort 1
|
|||
|
9. DW2 : Stoerdatenwort 2
|
|||
|
10. FRG : FREIGABE
|
|||
|
11. Quit : Bitmuster KM 1 = quittiert sich selbst
|
|||
|
0 = Stoerung wird extern ( z.B. PC) quittiert
|
|||
|
12. ANZ : Anzahl der Stoermeldungen
|
|||
|
13. STDB : Stoermelde-DB
|
|||
|
|
|||
|
|
|||
|
ANZ = 1 ANZ = 2
|
|||
|
TYP AW1 AW2 EW1 EW2 DW1 DW1 DW2
|
|||
|
----------------------------------------------------------------------------
|
|||
|
RW Y1_A Y2_B S1_A S2_B DW1 DW1_A DW2_B
|
|||
|
KL Y1_auf - S_auf S_zu DW1 DW_n.auf DW_n.zu
|
|||
|
MO M1 - K1 - DW1 DW1 -
|
|||
|
QV Y1_auf - - S_zu DW1 DW_n.auf DW_n.zu
|
|||
|
BI Bitleiste - DW1
|
|||
|
BN Bitleist neg. DW1
|
|||
|
FU Freigabe - Betrieb - DW1
|
|||
|
IV Impulsventil - Rueckmeld -
|
|||
|
|
|||
|
|
|||
|
AUFBAU DES STOERDATENBAUSTEINS:
|
|||
|
|
|||
|
BLOCK 1 : STOERUNGEN AN LEITSYSTEM
|
|||
|
BLOCK 2 : DISKREPANZEN ZWISCHEN E UND A
|
|||
|
BLOCK 3 : ERSTWERTMELDUNG
|
|||
|
BLOCK 4 : FEHLERQUITTUNG von Leitsystem fuer jedes einzelne Bit
|
|||
|
FB 102 -FB102 FAULT INDIREKT C:ZONE10ST.S5D LEN=401
|
|||
|
Page 2
|
|||
|
|
|||
|
|
|||
|
Beispiel fuer Signalverlauf:
|
|||
|
============================
|
|||
|
|
|||
|
Ausgang ___-------------------_______________________________________
|
|||
|
Eingang __________-------------------------------------______________
|
|||
|
A xor E ___-------____________-------------------------______________
|
|||
|
Imp _______-________-________-________-________-________-________
|
|||
|
Zw.speich._______---_______________----------------------______________
|
|||
|
Stoerung __________________________________-------------______________
|
|||
|
Quittung ___________________________________________----______________
|
|||
|
|
|||
|
|
|||
|
|
|||
|
FUNKTION DES BAUSTEINS:
|
|||
|
=======================
|
|||
|
|
|||
|
1. ZYKLISCHER VERGLEICH VON AUSGANGSWORT UND EINGANGSWORT
|
|||
|
UND ABSPEICHERN DER DISKREPANZ IN BLOCK 2
|
|||
|
|
|||
|
2. BILDUNG DER STOERUNGEN AUS AKTUELLER UND LETZTER DISKREPANZ
|
|||
|
|
|||
|
3. RUECKSETZEN DER STOERUNGEN, WENN KEINE DISKREPANZ ZWISCHEN E UND A
|
|||
|
UND EINE QUITTUNG VORLIEGT
|
|||
|
|
|||
|
|
|||
|
Merkerworte:
|
|||
|
============
|
|||
|
|
|||
|
#AW1 #AW2
|
|||
|
MW230 MW240 Zeiger auf Stoerdatenwort
|
|||
|
MW232 MW242 Zeiger auf Zwischenspeicher
|
|||
|
MW234 MW244 Zeiger auf Quittung
|
|||
|
|
|||
|
MW250 Diskrepanz AW1
|
|||
|
MW252 Diskrepanz AW2
|
|||
|
|
|||
|
|
|||
|
Name :STOERUNG
|
|||
|
Decl :TYP I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KS
|
|||
|
Decl :IMP I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :AW1 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :AW2 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :EW1 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :EW2 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :FILT I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KM
|
|||
|
Decl :DW1 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :DW2 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :FRG I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :QUIT I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KM
|
|||
|
Decl :ANZ I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :STDB I/Q/D/B/T/C: B
|
|||
|
|
|||
|
:L KH 0000
|
|||
|
:T FW 250 MW250 = Diskrepanz AW1
|
|||
|
:T FW 252 MW252 = Diskrepanz AW2
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 2 Rohrweiche 2A / 2E
|
|||
|
|
|||
|
|
|||
|
:LW =TYP
|
|||
|
FB 102 -FB102 FAULT INDIREKT C:ZONE10ST.S5D LEN=401
|
|||
|
Page 3
|
|||
|
:L KS RW
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1 U A1
|
|||
|
:L =EW1 UN E1
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:L FW 250 MW250 = Diskrepanz AW1
|
|||
|
:OW
|
|||
|
:T FW 250
|
|||
|
:
|
|||
|
:L =AW2 U A2
|
|||
|
:L =EW2 UN E2
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:L FW 252 MW252 = Diskrepanz AW2
|
|||
|
:OW
|
|||
|
:T FW 252
|
|||
|
:
|
|||
|
:L =EW1 UN E1
|
|||
|
:CFW UN E2
|
|||
|
:L =EW2
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:L FW 250
|
|||
|
:OW
|
|||
|
:T FW 250
|
|||
|
:
|
|||
|
:L =EW1 U E1
|
|||
|
:L =EW2 U E2
|
|||
|
:AW
|
|||
|
:L FW 250
|
|||
|
:OW
|
|||
|
:T FW 250
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 3 Impulsventil
|
|||
|
:LW =TYP
|
|||
|
:L KS IV
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1 U A1
|
|||
|
:L =EW1 UN E1
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:T FW 250 MW250 = Diskrepanz
|
|||
|
:
|
|||
|
M001 :
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 4 KLAPPE 1A / 2E
|
|||
|
|
|||
|
:LW =TYP
|
|||
|
:L KS KL
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1
|
|||
|
:L =EW1
|
|||
|
FB 102 -FB102 FAULT INDIREKT C:ZONE10ST.S5D LEN=401
|
|||
|
Page 4
|
|||
|
:XOW
|
|||
|
:L FW 250
|
|||
|
:OW
|
|||
|
:T FW 250 KLappe geht nicht auf
|
|||
|
:
|
|||
|
:L =AW1
|
|||
|
:L =EW2
|
|||
|
:CFW
|
|||
|
:XOW
|
|||
|
:L FW 252
|
|||
|
:OW
|
|||
|
:T FW 252 Klappe geht nicht zu
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 5 MOTOR 1A / 1E
|
|||
|
:LW =TYP
|
|||
|
:L KS MO
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1 U A
|
|||
|
:L =EW1 UN E
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:L FW 250 Motor laeuft nicht an
|
|||
|
:OW
|
|||
|
:T FW 250
|
|||
|
:
|
|||
|
:L =AW1 UN A
|
|||
|
:CFW U E
|
|||
|
:L =EW1
|
|||
|
:AW
|
|||
|
:L FW 252
|
|||
|
:OW
|
|||
|
:T FW 252 Motor geht nicht aus
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 6 QUETSCHVENTIL 1 A / 1 E
|
|||
|
:LW =TYP
|
|||
|
:L KS QV
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1 U A auf
|
|||
|
:L =EW2 U E zu
|
|||
|
:AW
|
|||
|
:L FW 250
|
|||
|
:OW
|
|||
|
:T FW 250 Ventil geht nicht auf
|
|||
|
:
|
|||
|
:L =AW1 UN A auf
|
|||
|
:CFW
|
|||
|
:L =EW2 UN E zu
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:L FW 252
|
|||
|
:OW
|
|||
|
:T FW 252 Ventil geht nicht zu
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
FB 102 -FB102 FAULT INDIREKT C:ZONE10ST.S5D LEN=401
|
|||
|
Page 5
|
|||
|
Segment 7 Frequenzumformer
|
|||
|
|
|||
|
:LW =TYP 14.10.93 HKT
|
|||
|
:L KS FU
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1 U A Ansteuerung
|
|||
|
:L =EW1 UN E Betrieb
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:T FW 250 Keine Rueckmeldung bei
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 8 STOERUNGS-BITLEISTE
|
|||
|
:LW =TYP
|
|||
|
:L KS BI
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1 #AW1 = Stoerbitleiste
|
|||
|
:T FW 250 MW250 = Diskrepanz AW1
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 9 Stoerung negative Bitleiste
|
|||
|
:LW =TYP 14.10.93 HKT
|
|||
|
:L KS BN
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AW1
|
|||
|
:CFW
|
|||
|
:T FW 250 MW250 = Diskrepanz AW1
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 10 STOERAUSWERTUNG RW/KL/MO/QV
|
|||
|
:L =DW1 #S-DW
|
|||
|
:T FW 230 MW230 ZEIGER AUF STOERDATENWORT
|
|||
|
:L KF +64 #OFFS ab DW 64 Zwischenspeicher
|
|||
|
:+F
|
|||
|
:T FW 232 MW232 ZEIG. ZWISCHENSPEICHER
|
|||
|
:
|
|||
|
:L FW 230
|
|||
|
:L KF +192 ab DW 192 Quittierung v. PC
|
|||
|
:+F
|
|||
|
:T FW 234 MW234 ZEIGER AUF QUITTIERUNG
|
|||
|
:
|
|||
|
:LW =ANZ 2 STOERMELDUNGEN JE ELEMENT ?
|
|||
|
:L KF +2
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =DW2
|
|||
|
:T FW 240 MW240 ZEIGER AUF STOER-DW2
|
|||
|
:L KF +64
|
|||
|
:+F
|
|||
|
:T FW 242 MW242 ZEIGER AUF ZWISCHENSP.2
|
|||
|
:
|
|||
|
FB 102 -FB102 FAULT INDIREKT C:ZONE10ST.S5D LEN=401
|
|||
|
Page 6
|
|||
|
:L FW 240
|
|||
|
:L KF +192
|
|||
|
:+F
|
|||
|
:T FW 244 MW244 ZEIGER AUF QUITTUNG 2
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 11 STOER-DB
|
|||
|
:DO =STDB
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 12 STOERUNGSQUITTIERUNG
|
|||
|
:DO FW 230 MW230 = ZEIGER AUF STOER-DW
|
|||
|
:L DW 0
|
|||
|
:LW =QUIT #QUIT
|
|||
|
:AW
|
|||
|
:T FW 236 MW236 = ZWISCHENSPEICHER
|
|||
|
:
|
|||
|
:DO FW 230 MW230 = ZEIGER AUF STOER-DW
|
|||
|
:L DW 0
|
|||
|
:DO FW 234 MW234 = ZEIGER AUF QUITTIERUNG
|
|||
|
:L DW 0
|
|||
|
:AW
|
|||
|
:L FW 236 MW236 = ZWISCHENSPEICHER
|
|||
|
:OW
|
|||
|
:DO FW 234 MW234 = ZEIGER AUF QUITTIERUNG
|
|||
|
:T DW 0
|
|||
|
:
|
|||
|
:LW =ANZ QUITTIERUNG #DW2
|
|||
|
:L KF +2
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:DO FW 240
|
|||
|
:L DW 0
|
|||
|
:LW =QUIT
|
|||
|
:AW
|
|||
|
:T FW 246
|
|||
|
:
|
|||
|
:DO FW 240
|
|||
|
:L DW 0
|
|||
|
:DO FW 244
|
|||
|
:L DW 0
|
|||
|
:AW
|
|||
|
:L FW 246
|
|||
|
:OW
|
|||
|
:DO FW 244
|
|||
|
:T DW 0
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 13 NUR EINE STOERUNG ANZEIGEN
|
|||
|
:LW =ANZ
|
|||
|
:L KF +1
|
|||
|
:>F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L FW 250
|
|||
|
:L FW 252
|
|||
|
:OW
|
|||
|
:T FW 250
|
|||
|
FB 102 -FB102 FAULT INDIREKT C:ZONE10ST.S5D LEN=401
|
|||
|
Page 7
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 14 Stoerauswertung
|
|||
|
:A F 236.0 M236.0: 2.STOERW. N. BEARBEITET
|
|||
|
:R F 236.0
|
|||
|
:
|
|||
|
M005 :
|
|||
|
:LW =FILT FILTER
|
|||
|
:L FW 250 MW250 = DISKREPANZ
|
|||
|
:AW
|
|||
|
:T FW 250
|
|||
|
:
|
|||
|
:AN =FRG #FRG
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:AN =IMP #IMP _____-______________-_____
|
|||
|
:JC =M002
|
|||
|
: Stoerung bilden:
|
|||
|
:DO FW 232
|
|||
|
:L DW 0
|
|||
|
:LW =FILT Filter -> Bits ausserhalb des
|
|||
|
:CFW Filters bleiben erhalten
|
|||
|
:AW
|
|||
|
:L FW 250 MW250 = Diskrepanz
|
|||
|
:OW
|
|||
|
:
|
|||
|
:DO FW 232 ALTE DISKREPANZ LADEN
|
|||
|
:L DW 0 MW232=ZEIG. ALTE DISKREPANZ
|
|||
|
:TAK
|
|||
|
:DO FW 232 neue Diskrepanz speichern
|
|||
|
:T DW 0
|
|||
|
:AW alte u. neue Diskrepanz = Stoer.
|
|||
|
:
|
|||
|
:LW =FILT
|
|||
|
:AW
|
|||
|
:
|
|||
|
:DO FW 230
|
|||
|
:L DW 0
|
|||
|
:OW Stoerung wird hier nur gesetzt
|
|||
|
:DO FW 230
|
|||
|
:T DW 0
|
|||
|
:JU =M003 , nicht rueckgesetzt
|
|||
|
M002 :
|
|||
|
:DO FW 230
|
|||
|
:L DW 0
|
|||
|
:LW =FILT
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:T FW 254 MW254=Stoer.ausserhalb Filter
|
|||
|
:
|
|||
|
:DO FW 232
|
|||
|
:L DW 0
|
|||
|
:LW =FILT MW232 = Diskrepanz
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:L FW 250
|
|||
|
:OW
|
|||
|
:DO FW 232 MW250 = Diskrepanz
|
|||
|
:L DW 0
|
|||
|
:AW MW232 = Alte Diskrepanz
|
|||
|
:DO FW 232
|
|||
|
:T DW 0
|
|||
|
FB 102 -FB102 FAULT INDIREKT C:ZONE10ST.S5D LEN=401
|
|||
|
Page 8
|
|||
|
:
|
|||
|
:DO FW 234
|
|||
|
:L DW 0
|
|||
|
:TAK MW234 = Quittung PLS
|
|||
|
:XOW
|
|||
|
:AW
|
|||
|
:
|
|||
|
:DO FW 230
|
|||
|
:L DW 0
|
|||
|
:TAK MW230 = Stoerungen
|
|||
|
:XOW
|
|||
|
:AW
|
|||
|
:L FW 254 MW254=Stoer.ausserh.Filter
|
|||
|
:OW
|
|||
|
:DO FW 230
|
|||
|
:T DW 0
|
|||
|
: MW230=ZEIGER AUF STOERUNGEN
|
|||
|
:JU =M003
|
|||
|
M001 :L KF +0
|
|||
|
:DO FW 232
|
|||
|
:T DW 0
|
|||
|
M003 : MW232 = Zeiger Zwischenspeicher
|
|||
|
:LW =ANZ
|
|||
|
:L KF +2
|
|||
|
:<F
|
|||
|
:O F 236.0
|
|||
|
:JC =M004
|
|||
|
:
|
|||
|
:L FW 252
|
|||
|
:T FW 250
|
|||
|
:
|
|||
|
:L FW 240
|
|||
|
:T FW 230 M236.0=ZWEITES STOERWORT FERTIG
|
|||
|
:
|
|||
|
:L FW 242 ZEIGER FUER ZWEITES STOERWORT
|
|||
|
:T FW 232 MW252 = ZWEITE DISKREPANZ
|
|||
|
: MW250 = ERSTE DISKREPANZ
|
|||
|
:L FW 244
|
|||
|
:T FW 234 MW240 = Stoerdatenwort
|
|||
|
:AN F 236.0 MW230 = Stoerdatenwort
|
|||
|
:S F 236.0
|
|||
|
:JU =M005
|
|||
|
: Zeiger auf Zwischenspeicher
|
|||
|
M004 :***
|
|||
|
|
|||
|
|
|||
|
Segment 15
|
|||
|
:BE
|
|||
|
|
|||
|
FB 103 -FB103 TABLE C:ZONE10ST.S5D LEN=104
|
|||
|
Page 1
|
|||
|
Segment 1 Adressen aus Tabelle laden
|
|||
|
|
|||
|
===============================================================================
|
|||
|
|
|||
|
letzte Aenderung :
|
|||
|
|
|||
|
Erweiterung um indirekte Quell und Ziel DB Angabe
|
|||
|
10.06.94 rh
|
|||
|
|
|||
|
|
|||
|
|
|||
|
================================================================================
|
|||
|
Name :TABELLE
|
|||
|
Decl :DBQ I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :NOP I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KY
|
|||
|
Decl :DBZ I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :DWZ I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :SINR I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :ANZ I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :SPRU I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :ANF I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :NROK I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
|
|||
|
:L =DBQ
|
|||
|
:T FW 230
|
|||
|
:L =DBZ
|
|||
|
:T FW 232
|
|||
|
:LW =DWZ
|
|||
|
:T FW 234
|
|||
|
:L =SINR
|
|||
|
:T FW 236
|
|||
|
:LW =SPRU
|
|||
|
:T FW 238
|
|||
|
:L =SINR
|
|||
|
:D 1
|
|||
|
:LW =ANF
|
|||
|
:+F
|
|||
|
:T FW 240
|
|||
|
:L =DBQ
|
|||
|
:L KY 1,0
|
|||
|
:OW
|
|||
|
:JU -OB181:TEST DB/DX
|
|||
|
:BEC DB nicht vorhanden
|
|||
|
:TAK
|
|||
|
:T FW 242 MW242 = Laenge Quell-DB
|
|||
|
:L KF +0
|
|||
|
:T FW 246 MW246 = Zaehler
|
|||
|
:
|
|||
|
M002 :
|
|||
|
:JU -FB175 LOAD DW INDIR.
|
|||
|
Name :LADE DW
|
|||
|
DB : FW 230 MW230 = Quell-DB
|
|||
|
DW : FW 240 MW240 = Tabellen-Start
|
|||
|
DBDX : KS DB
|
|||
|
:T FW 244 MW244 = geladener Wert
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:LW =NOP
|
|||
|
:T FW 244
|
|||
|
:A =NROK
|
|||
|
:RB =NROK
|
|||
|
M001 :
|
|||
|
:JU -FB176 STORE DW INDIR.
|
|||
|
FB 103 -FB103 TABLE C:ZONE10ST.S5D LEN=104
|
|||
|
Page 2
|
|||
|
Name :TANS DW
|
|||
|
DB : FW 232 MW242 = Ziel-DB
|
|||
|
DW : FW 234 MW234 = Ziel-DW
|
|||
|
WERT : FW 244 MW244 = Wert
|
|||
|
DBDX : KS DB
|
|||
|
:L FW 234 MW234 = Zeiger Ziel-Tabelle
|
|||
|
:L KF +1
|
|||
|
:+F
|
|||
|
:T FW 234
|
|||
|
:
|
|||
|
:L FW 240 MW240 = Zeiger Quell-Tabelle
|
|||
|
:L FW 238 MW238 = Tabellensprung
|
|||
|
:+F
|
|||
|
:T FW 240
|
|||
|
:
|
|||
|
:L FW 246
|
|||
|
:I 1
|
|||
|
:T FW 246
|
|||
|
:LW =ANZ Anzahl der zu ladende Worte
|
|||
|
:<F
|
|||
|
:JC =M002
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 175 = FB175 LOAD DW INDIR. sp
|
|||
|
FB 176 = FB176 STORE DW INDIR. sp
|
|||
|
|
|||
|
OB 181 = OB181:TEST DB/DX
|
|||
|
|
|||
|
FB 104 -FB104 STANDARDFLAGS C:ZONE10ST.S5D LEN=624
|
|||
|
Page 1
|
|||
|
Segment 1 standard flags
|
|||
|
Name :STANDARD
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2 trigger toggle bits
|
|||
|
:L -MB 7 OLD TOGGLEBITS
|
|||
|
:L -MB 5 TOGGLEBITS
|
|||
|
:T -MB 7 OLD TOGGLEBITS
|
|||
|
:XOW
|
|||
|
:T -MB 6 ONE_SHOTS
|
|||
|
:***
|
|||
|
|
|||
|
FY 7 = MB 7 OLD TOGGLEBITS take over bit pattern
|
|||
|
FY 5 = MB 5 TOGGLEBITS pattern with flashing pulses from OB's
|
|||
|
FY 6 = MB 6 ONE_SHOTS rising and falling pulse (for one cycle)
|
|||
|
|
|||
|
Segment 3 constant flags
|
|||
|
:AN -M 0.1 CONSTANT 1
|
|||
|
:S -M 0.1 CONSTANT 1
|
|||
|
:
|
|||
|
:A -M 0.2 CONSTANT 0
|
|||
|
:R -M 0.2 CONSTANT 0
|
|||
|
:***
|
|||
|
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
F 0.2 = M 0.2 CONSTANT 0
|
|||
|
|
|||
|
Segment 4 control voltage / lamp test
|
|||
|
:A -E 22.0=z10.PLC-cvo:on
|
|||
|
:= -M 1.1 CONTROL VOLTAGE
|
|||
|
:
|
|||
|
:A -E 22.2=z10.PLC-lts:on
|
|||
|
:= -M 4.5 GLOBAL LAMBTEST
|
|||
|
:***
|
|||
|
|
|||
|
I 22.0 = E 22.0=z10.PLC-cvo:on control voltage on PLC
|
|||
|
F 1.1 = M 1.1 CONTROL VOLTAGE
|
|||
|
I 22.2 = E 22.2=z10.PLC-lts:on lamp test on PLC
|
|||
|
F 4.5 = M 4.5 GLOBAL LAMBTEST
|
|||
|
|
|||
|
Segment 5 unit idle
|
|||
|
:L KF +0
|
|||
|
:T -MW 162 PLANT STAT-BITS prepare plant status bits
|
|||
|
:
|
|||
|
:CX -DX200 PL1-5 MX520,HO580
|
|||
|
:A D 11.4 PHASE MX520_EMPTY: idle
|
|||
|
:A D 61.4 520_ia
|
|||
|
:A D 111.4 520_dinop
|
|||
|
:= -M 162.0 MX520 UNIT_IDLE
|
|||
|
:
|
|||
|
:A D 161.4 580_em
|
|||
|
:A D 211.4 580_ch
|
|||
|
:CX -DX201 PL6-10HO561,BD560
|
|||
|
:A D 11.4 580_ma
|
|||
|
:= -M 162.1 HO580 UNIT_IDLE
|
|||
|
:
|
|||
|
:A D 61.4 561_em
|
|||
|
:A D 111.4 561_ch
|
|||
|
:A D 161.4 561_di
|
|||
|
:= -M 162.2 HO561 UNIT_IDLE
|
|||
|
:***
|
|||
|
|
|||
|
FW 162 = MW 162 PLANT STAT-BITS
|
|||
|
FB 104 -FB104 STANDARDFLAGS C:ZONE10ST.S5D LEN=624
|
|||
|
Page 2
|
|||
|
F 162.0 = M 162.0 MX520 UNIT_IDLE
|
|||
|
F 162.1 = M 162.1 HO580 UNIT_IDLE
|
|||
|
F 162.2 = M 162.2 HO561 UNIT_IDLE
|
|||
|
|
|||
|
DX 200 = DX200 PL1-5 MX520,HO580 PL1-3: UNIT MX520 PL4,5: UNIT HO580
|
|||
|
DX 201 = DX201 PL6-10HO561,BD560 PL6:RES PL7-9:UNIT HO561 PL10:UNIT BD560
|
|||
|
|
|||
|
Segment 6 unit idle
|
|||
|
:A D 211.4 560_ch
|
|||
|
:CX -DX202 PL11-15 BD560,RES
|
|||
|
:A D 11.4 560_ma
|
|||
|
:A D 61.4 560_bl
|
|||
|
:A D 111.4 560_dinop
|
|||
|
:A D 161.4 560_di
|
|||
|
:= -M 162.3 BD560 UNIT_IDLE
|
|||
|
:***
|
|||
|
|
|||
|
F 162.3 = M 162.3 BD560 UNIT_IDLE
|
|||
|
|
|||
|
DX 202 = DX202 PL11-15 BD560,RES PL11-14: UNIT BD560 PL15: RESERVE
|
|||
|
|
|||
|
Segment 7 operator confirm on unit
|
|||
|
:CX -DX200 PL1-5 MX520,HO580
|
|||
|
:A D 19.4 PHASE MX520_EMPTY: oper.conf.
|
|||
|
:A D 69.4 520_ia
|
|||
|
:A D 119.4 520_dinop
|
|||
|
:= -M 163.0 MX520 CONFIRM
|
|||
|
:
|
|||
|
:A D 169.4 580_em
|
|||
|
:A D 219.4 580_ch
|
|||
|
:CX -DX201 PL6-10HO561,BD560
|
|||
|
:A D 19.4 580_ma
|
|||
|
:= -M 163.1 HO580 CONFIRM
|
|||
|
:
|
|||
|
:A D 69.4 561_em
|
|||
|
:A D 119.4 561_ch
|
|||
|
:A D 169.4 561_di
|
|||
|
:= -M 163.2 HO561 CONFIRM
|
|||
|
:***
|
|||
|
|
|||
|
F 163.0 = M 163.0 MX520 CONFIRM
|
|||
|
F 163.1 = M 163.1 HO580 CONFIRM
|
|||
|
F 163.2 = M 163.2 HO561 CONFIRM
|
|||
|
|
|||
|
DX 200 = DX200 PL1-5 MX520,HO580 PL1-3: UNIT MX520 PL4,5: UNIT HO580
|
|||
|
DX 201 = DX201 PL6-10HO561,BD560 PL6:RES PL7-9:UNIT HO561 PL10:UNIT BD560
|
|||
|
|
|||
|
Segment 8 operator confirm on unit
|
|||
|
:A D 219.4 560_ch
|
|||
|
:CX -DX202 PL11-15 BD560,RES
|
|||
|
:A D 19.4 560_ma
|
|||
|
:A D 69.4 560_bl
|
|||
|
:A D 119.4 560_dinop
|
|||
|
:A D 169.4 560_di
|
|||
|
:= -M 163.3 BD560 CONFIRM
|
|||
|
:***
|
|||
|
|
|||
|
F 163.3 = M 163.3 BD560 CONFIRM
|
|||
|
|
|||
|
DX 202 = DX202 PL11-15 BD560,RES PL11-14: UNIT BD560 PL15: RESERVE
|
|||
|
|
|||
|
Segment 9 release Mode switch
|
|||
|
:C -DB5 GLOBAL DATA
|
|||
|
:
|
|||
|
FB 104 -FB104 STANDARDFLAGS C:ZONE10ST.S5D LEN=624
|
|||
|
Page 3
|
|||
|
:A -M 162.0 MX520 UNIT_IDLE
|
|||
|
:A -M 162.1 HO580 UNIT_IDLE
|
|||
|
:A -M 162.2 HO561 UNIT_IDLE
|
|||
|
:A -M 162.3 BD560 UNIT_IDLE
|
|||
|
:= D 4.0 release Mode switch
|
|||
|
:
|
|||
|
:L -MW 162 PLANT STAT-BITS
|
|||
|
:T DW 5 plant status bits for pli
|
|||
|
:***
|
|||
|
|
|||
|
F 162.0 = M 162.0 MX520 UNIT_IDLE
|
|||
|
F 162.1 = M 162.1 HO580 UNIT_IDLE
|
|||
|
F 162.2 = M 162.2 HO561 UNIT_IDLE
|
|||
|
F 162.3 = M 162.3 BD560 UNIT_IDLE
|
|||
|
FW 162 = MW 162 PLANT STAT-BITS
|
|||
|
|
|||
|
DB 5 = DB5 GLOBAL DATA
|
|||
|
|
|||
|
Segment 10 Mode switch
|
|||
|
:L DW 1 MODE Plant
|
|||
|
:L KF +0
|
|||
|
:!=F
|
|||
|
:= -M 4.0 GLOBAL AUTO-MODE
|
|||
|
:
|
|||
|
:L DW 1 MODE Plant
|
|||
|
:L KF +1
|
|||
|
:!=F
|
|||
|
:= -M 4.1 GLOB. MANUAL-MODE
|
|||
|
:
|
|||
|
:L DW 1 MODE Plant
|
|||
|
:L KF +2
|
|||
|
:!=F
|
|||
|
:= -M 4.2 GLOB.SERVICE-MODE
|
|||
|
:***
|
|||
|
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
F 4.2 = M 4.2 GLOB.SERVICE-MODE
|
|||
|
|
|||
|
Segment 11 Init Service-mode
|
|||
|
:A -M 4.2 GLOB.SERVICE-MODE
|
|||
|
:AN -M 1.3 RUN UP INIT.
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T DW 0 INIT Service-mode
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 4.2 = M 4.2 GLOB.SERVICE-MODE
|
|||
|
F 1.3 = M 1.3 RUN UP INIT.
|
|||
|
|
|||
|
Segment 12 clock level indicators
|
|||
|
:A -M 4.0 GLOBAL AUTO-MODE
|
|||
|
:A -M 4.4 HF AUTO-MODE
|
|||
|
:= -M 4.7 PLI_ENABLE_EXT_OW
|
|||
|
:
|
|||
|
:A -M 4.0 GLOBAL AUTO-MODE
|
|||
|
:= -M 4.4 HF AUTO-MODE
|
|||
|
:
|
|||
|
:A -M 6.5 ONE_SHOT 5_sec
|
|||
|
:= -M 0.6 CLOCK LEVEL IND.
|
|||
|
:***
|
|||
|
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
FB 104 -FB104 STANDARDFLAGS C:ZONE10ST.S5D LEN=624
|
|||
|
Page 4
|
|||
|
F 4.4 = M 4.4 HF AUTO-MODE
|
|||
|
F 4.7 = M 4.7 PLI_ENABLE_EXT_OW ext ownership for phase possible
|
|||
|
F 6.5 = M 6.5 ONE_SHOT 5_sec flashpulse 5 sec
|
|||
|
F 0.6 = M 0.6 CLOCK LEVEL IND.
|
|||
|
|
|||
|
Segment 13 one second impulse
|
|||
|
:A -M 6.3 ONE_SHOT 1_sec
|
|||
|
:= -M 0.3 1 SEC. IMPULSE
|
|||
|
:***
|
|||
|
|
|||
|
F 6.3 = M 6.3 ONE_SHOT 1_sec flashpulse 1 sec
|
|||
|
F 0.3 = M 0.3 1 SEC. IMPULSE
|
|||
|
|
|||
|
Segment 14 fault evaluation fast
|
|||
|
:A -M 6.4 ONE_SHOT 2_sec
|
|||
|
:= -M 0.7 FLT.EVAL. FAST
|
|||
|
:***
|
|||
|
|
|||
|
F 6.4 = M 6.4 ONE_SHOT 2_sec flashpulse 2 sec
|
|||
|
F 0.7 = M 0.7 FLT.EVAL. FAST
|
|||
|
|
|||
|
Segment 15 fault evaluation slow
|
|||
|
:A -M 6.5 ONE_SHOT 5_sec
|
|||
|
:= -M 1.0 FLT.EVAL. SLOW
|
|||
|
:***
|
|||
|
|
|||
|
F 6.5 = M 6.5 ONE_SHOT 5_sec flashpulse 5 sec
|
|||
|
F 1.0 = M 1.0 FLT.EVAL. SLOW
|
|||
|
|
|||
|
Segment 16 flash clock fast
|
|||
|
|
|||
|
|
|||
|
:A -M 5.2 TOGGLEBIT 500_ms
|
|||
|
:= -M 0.4 FLASH CLOCK FAST
|
|||
|
:***
|
|||
|
|
|||
|
F 5.2 = M 5.2 TOGGLEBIT 500_ms toggle of OB 12 (period 1 sec)
|
|||
|
F 0.4 = M 0.4 FLASH CLOCK FAST
|
|||
|
|
|||
|
Segment 17 flash clock slow
|
|||
|
|
|||
|
:A -M 5.3 TOGGLEBIT 1_sec
|
|||
|
:= -M 0.5 FLASH CLOCK SLOW
|
|||
|
:***
|
|||
|
|
|||
|
F 5.3 = M 5.3 TOGGLEBIT 1_sec toggle of OB 13 (period 2 sec)
|
|||
|
F 0.5 = M 0.5 FLASH CLOCK SLOW
|
|||
|
|
|||
|
Segment 18 clock for discharge flap
|
|||
|
|
|||
|
:L KT 014.2 impulse flap clock
|
|||
|
:T FW 200
|
|||
|
:L KT 010.1 break flap clock
|
|||
|
:T FW 202
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : -M 0.1 CONSTANT 1
|
|||
|
T : -T1 FLAP CLOCK
|
|||
|
DWIM : FW 200
|
|||
|
DWPA : FW 202
|
|||
|
AUSG : -M 1.5 FLAP CLOCK
|
|||
|
POS : -M 0.1 CONSTANT 1
|
|||
|
DBT : -DB5 GLOBAL DATA
|
|||
|
RM : -M 1.5 FLAP CLOCK
|
|||
|
FB 104 -FB104 STANDARDFLAGS C:ZONE10ST.S5D LEN=624
|
|||
|
Page 5
|
|||
|
T-IN : FW 204
|
|||
|
IN : KS
|
|||
|
SOLL : KF +0
|
|||
|
IST : FW 206
|
|||
|
FERT : F 208.0
|
|||
|
BITL : FW 210
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB5 GLOBAL DATA
|
|||
|
:***
|
|||
|
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
T 1 = T1 FLAP CLOCK standard
|
|||
|
F 1.5 = M 1.5 FLAP CLOCK
|
|||
|
|
|||
|
DB 5 = DB5 GLOBAL DATA
|
|||
|
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 19 rapper clock fast
|
|||
|
|
|||
|
:L KT 010.1 impulse rapper clock fast
|
|||
|
:T FW 200
|
|||
|
:L KT 050.1 break rapper clock fast
|
|||
|
:T FW 202
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : -M 0.1 CONSTANT 1
|
|||
|
T : -T2 RAPPER CLOCK FAST
|
|||
|
DWIM : FW 200
|
|||
|
DWPA : FW 202
|
|||
|
AUSG : -M 1.6 RAPPER CLOCK FAST
|
|||
|
POS : -M 0.1 CONSTANT 1
|
|||
|
DBT : -DB5 GLOBAL DATA
|
|||
|
RM : -M 1.6 RAPPER CLOCK FAST
|
|||
|
T-IN : FW 204
|
|||
|
IN : KS
|
|||
|
SOLL : KF +0
|
|||
|
IST : FW 206
|
|||
|
FERT : F 208.0
|
|||
|
BITL : FW 210
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB5 GLOBAL DATA
|
|||
|
:***
|
|||
|
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
T 2 = T2 RAPPER CLOCK FAST standard
|
|||
|
F 1.6 = M 1.6 RAPPER CLOCK FAST
|
|||
|
|
|||
|
DB 5 = DB5 GLOBAL DATA
|
|||
|
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 20 rapper clock slow
|
|||
|
|
|||
|
:L KT 010.1 impulse rapper clock slow
|
|||
|
:T FW 200
|
|||
|
:L KT 100.1 break rapper clock slow
|
|||
|
:T FW 202
|
|||
|
:JU -FB113 CLOCK GENERAT.TIM
|
|||
|
Name :TAKT
|
|||
|
FRG : -M 0.1 CONSTANT 1
|
|||
|
T : -T3 RAPPER CLOCK SLOW
|
|||
|
DWIM : FW 200
|
|||
|
DWPA : FW 202
|
|||
|
FB 104 -FB104 STANDARDFLAGS C:ZONE10ST.S5D LEN=624
|
|||
|
Page 6
|
|||
|
AUSG : -M 1.7 RAPPER CLOCK SLOW
|
|||
|
POS : -M 0.1 CONSTANT 1
|
|||
|
DBT : -DB5 GLOBAL DATA
|
|||
|
RM : -M 1.7 RAPPER CLOCK SLOW
|
|||
|
T-IN : FW 204
|
|||
|
IN : KS
|
|||
|
SOLL : KF +0
|
|||
|
IST : FW 206
|
|||
|
FERT : F 208.0
|
|||
|
BITL : FW 210
|
|||
|
DAUE : -M 0.1 CONSTANT 1
|
|||
|
DBST : -DB5 GLOBAL DATA
|
|||
|
:***
|
|||
|
|
|||
|
F 0.1 = M 0.1 CONSTANT 1
|
|||
|
T 3 = T3 RAPPER CLOCK SLOW standard
|
|||
|
F 1.7 = M 1.7 RAPPER CLOCK SLOW
|
|||
|
|
|||
|
DB 5 = DB5 GLOBAL DATA
|
|||
|
|
|||
|
FB 113 = FB113 CLOCK GENERAT.TIM with nominal instruction HKT al
|
|||
|
|
|||
|
Segment 21 evaluate level indicators
|
|||
|
:C -DB9 EVALUATE LEV.INDIC.
|
|||
|
:JU -FB107 LEVEL INDICATORS
|
|||
|
Name :SILOMELD
|
|||
|
EW : IW 18
|
|||
|
FOLG : DW 0
|
|||
|
MELD : DW 1
|
|||
|
ERST : DW 2
|
|||
|
TAKT : -M 0.6 CLOCK LEVEL IND.
|
|||
|
FILT : KM 10010010 00100100
|
|||
|
P-N : KM 00000000 00000000
|
|||
|
:JU -FB107 LEVEL INDICATORS
|
|||
|
Name :SILOMELD
|
|||
|
EW : IW 20
|
|||
|
FOLG : DW 3
|
|||
|
MELD : DW 4
|
|||
|
ERST : DW 5
|
|||
|
TAKT : -M 0.6 CLOCK LEVEL IND.
|
|||
|
FILT : KM 00110000 10100010 *(5) E21.5, E21.7
|
|||
|
P-N : KM 00000000 00000000
|
|||
|
:***
|
|||
|
|
|||
|
F 0.6 = M 0.6 CLOCK LEVEL IND.
|
|||
|
|
|||
|
DB 9 = DB9 EVALUATE LEV.INDIC.
|
|||
|
|
|||
|
FB 107 = FB107 LEVEL INDICATORS word by word HKT al
|
|||
|
|
|||
|
Segment 22 data transfer outputs->RSView-DB
|
|||
|
:JU -FB174 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS A All outputs are coppied to DB97
|
|||
|
DB-Q : KF +0 (Output RSView)
|
|||
|
VON : KF +4
|
|||
|
BIS : KF +27 !physically available AB4-AB27
|
|||
|
ZIEL : KS DB
|
|||
|
DB-Z : KF +97
|
|||
|
NACH : KF +2
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : KF +0
|
|||
|
L-B : KS BI
|
|||
|
:***
|
|||
|
FB 104 -FB104 STANDARDFLAGS C:ZONE10ST.S5D LEN=624
|
|||
|
Page 7
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
|
|||
|
FB 174 = FB174 COPY BLOCK Parameter: D sp
|
|||
|
|
|||
|
Segment 23 data transfer outputs->RSView-DB
|
|||
|
:JU -FB174 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS E All inputs are copied to DB98
|
|||
|
DB-Q : KF +0 (Input RSView)
|
|||
|
VON : KF +4
|
|||
|
BIS : KF +27 !physically available EB4-EB27
|
|||
|
ZIEL : KS DB
|
|||
|
DB-Z : KF +98
|
|||
|
NACH : KF +2
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : KF +0
|
|||
|
L-B : KS BI
|
|||
|
:***
|
|||
|
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
|
|||
|
FB 174 = FB174 COPY BLOCK Parameter: D sp
|
|||
|
|
|||
|
Segment 24 Initialize PLI
|
|||
|
: Transfer source:
|
|||
|
:L KF +207
|
|||
|
:T -MW180 PARAMETER 1 DX207 =>
|
|||
|
:L KF +0
|
|||
|
:T -MW182 PARAMETER 2 DW 0 =>
|
|||
|
:L KF +12
|
|||
|
:T -MW184 PARAMETER 3 12 DW's =>
|
|||
|
:***
|
|||
|
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
Segment 25 Initialize PLI MX520_EMPTY
|
|||
|
:O -M 4.0 GLOBAL AUTO-MODE If no AUTO- and no MANUAL-MODE
|
|||
|
:O -M 4.1 GLOB. MANUAL-MODE then PLI-Interface will be
|
|||
|
: initialisied
|
|||
|
:JC =M001
|
|||
|
:L KF +200
|
|||
|
:T FW 190 => PLI DX 200
|
|||
|
:L KF +0
|
|||
|
:T FW 192 => DW 0
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DX
|
|||
|
DB-Q : -MW180 PARAMETER 1
|
|||
|
VON : -MW182 PARAMETER 2
|
|||
|
BIS : -MW182 PARAMETER 2
|
|||
|
ZIEL : KS DX
|
|||
|
DB-Z : FW 190
|
|||
|
NACH : FW 192
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : -MW184 PARAMETER 3
|
|||
|
L-B : KS LA
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FB 104 -FB104 STANDARDFLAGS C:ZONE10ST.S5D LEN=624
|
|||
|
Page 8
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
Segment 26 Initialize PLI MX520_ING_ADD
|
|||
|
:O -M 4.0 GLOBAL AUTO-MODE If no AUTO- and no MANUAL-MODE
|
|||
|
:O -M 4.1 GLOB. MANUAL-MODE then PLI-Interface will be
|
|||
|
: initialisied
|
|||
|
:JC =M001
|
|||
|
:L KF +200
|
|||
|
:T FW 190 => PLI DX 200
|
|||
|
:L KF +50
|
|||
|
:T FW 192 => DW 50
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DX
|
|||
|
DB-Q : -MW180 PARAMETER 1
|
|||
|
VON : -MW182 PARAMETER 2
|
|||
|
BIS : -MW182 PARAMETER 2
|
|||
|
ZIEL : KS DX
|
|||
|
DB-Z : FW 190
|
|||
|
NACH : FW 192
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : -MW184 PARAMETER 3
|
|||
|
L-B : KS LA
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
Segment 27 Init PLI MX520_DISCHARGE_NOP
|
|||
|
:O -M 4.0 GLOBAL AUTO-MODE If no AUTO- and no MANUAL-MODE
|
|||
|
:O -M 4.1 GLOB. MANUAL-MODE then PLI-Interface will be
|
|||
|
: initialisied
|
|||
|
:JC =M001
|
|||
|
:L KF +200
|
|||
|
:T FW 190 => PLI DX 200
|
|||
|
:L KF +100
|
|||
|
:T FW 192 => DW 100
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DX
|
|||
|
DB-Q : -MW180 PARAMETER 1
|
|||
|
VON : -MW182 PARAMETER 2
|
|||
|
BIS : -MW182 PARAMETER 2
|
|||
|
ZIEL : KS DX
|
|||
|
DB-Z : FW 190
|
|||
|
NACH : FW 192
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : -MW184 PARAMETER 3
|
|||
|
L-B : KS LA
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
FB 104 -FB104 STANDARDFLAGS C:ZONE10ST.S5D LEN=624
|
|||
|
Page 9
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
Segment 28 Initialize PLI HO580_EMPTY
|
|||
|
:O -M 4.0 GLOBAL AUTO-MODE If no AUTO- and no MANUAL-MODE
|
|||
|
:O -M 4.1 GLOB. MANUAL-MODE then PLI-Interface will be
|
|||
|
: initialisied
|
|||
|
:JC =M001
|
|||
|
:L KF +200
|
|||
|
:T FW 190 => PLI DX 200
|
|||
|
:L KF +150
|
|||
|
:T FW 192 => DW 150
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DX
|
|||
|
DB-Q : -MW180 PARAMETER 1
|
|||
|
VON : -MW182 PARAMETER 2
|
|||
|
BIS : -MW182 PARAMETER 2
|
|||
|
ZIEL : KS DX
|
|||
|
DB-Z : FW 190
|
|||
|
NACH : FW 192
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : -MW184 PARAMETER 3
|
|||
|
L-B : KS LA
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
Segment 29 Initialize PLI HO580_CHARGE
|
|||
|
:O -M 4.0 GLOBAL AUTO-MODE If no AUTO- and no MANUAL-MODE
|
|||
|
:O -M 4.1 GLOB. MANUAL-MODE then PLI-Interface will be
|
|||
|
: initialisied
|
|||
|
:JC =M001
|
|||
|
:L KF +200
|
|||
|
:T FW 190 => PLI DX 200
|
|||
|
:L KF +200
|
|||
|
:T FW 192 => DW 200
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DX
|
|||
|
DB-Q : -MW180 PARAMETER 1
|
|||
|
VON : -MW182 PARAMETER 2
|
|||
|
BIS : -MW182 PARAMETER 2
|
|||
|
ZIEL : KS DX
|
|||
|
DB-Z : FW 190
|
|||
|
NACH : FW 192
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : -MW184 PARAMETER 3
|
|||
|
L-B : KS LA
|
|||
|
M001 :***
|
|||
|
FB 104 -FB104 STANDARDFLAGS C:ZONE10ST.S5D LEN=624
|
|||
|
Page 10
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
Segment 30 Initialize PLI HO561_EMPTY
|
|||
|
:O -M 4.0 GLOBAL AUTO-MODE If no AUTO- and no MANUAL-MODE
|
|||
|
:O -M 4.1 GLOB. MANUAL-MODE then PLI-Interface will be
|
|||
|
: initialisied
|
|||
|
:JC =M001
|
|||
|
:L KF +201
|
|||
|
:T FW 190 => PLI DX 201
|
|||
|
:L KF +50
|
|||
|
:T FW 192 => DW 50
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DX
|
|||
|
DB-Q : -MW180 PARAMETER 1
|
|||
|
VON : -MW182 PARAMETER 2
|
|||
|
BIS : -MW182 PARAMETER 2
|
|||
|
ZIEL : KS DX
|
|||
|
DB-Z : FW 190
|
|||
|
NACH : FW 192
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : -MW184 PARAMETER 3
|
|||
|
L-B : KS LA
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
Segment 31 Initialize PLI HO561_CHARGE
|
|||
|
:O -M 4.0 GLOBAL AUTO-MODE If no AUTO- and no MANUAL-MODE
|
|||
|
:O -M 4.1 GLOB. MANUAL-MODE then PLI-Interface will be
|
|||
|
: initialisied
|
|||
|
:JC =M001
|
|||
|
:L KF +201
|
|||
|
:T FW 190 => PLI DX 201
|
|||
|
:L KF +100
|
|||
|
:T FW 192 => DW 100
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DX
|
|||
|
DB-Q : -MW180 PARAMETER 1
|
|||
|
VON : -MW182 PARAMETER 2
|
|||
|
BIS : -MW182 PARAMETER 2
|
|||
|
ZIEL : KS DX
|
|||
|
DB-Z : FW 190
|
|||
|
NACH : FW 192
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : -MW184 PARAMETER 3
|
|||
|
L-B : KS LA
|
|||
|
FB 104 -FB104 STANDARDFLAGS C:ZONE10ST.S5D LEN=624
|
|||
|
Page 11
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
Segment 32 Initialize PLI HO561_DISCHARGE
|
|||
|
:O -M 4.0 GLOBAL AUTO-MODE If no AUTO- and no MANUAL-MODE
|
|||
|
:O -M 4.1 GLOB. MANUAL-MODE then PLI-Interface will be
|
|||
|
: initialisied
|
|||
|
:JC =M001
|
|||
|
:L KF +201
|
|||
|
:T FW 190 => PLI DX 201
|
|||
|
:L KF +150
|
|||
|
:T FW 192 => DW 150
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DX
|
|||
|
DB-Q : -MW180 PARAMETER 1
|
|||
|
VON : -MW182 PARAMETER 2
|
|||
|
BIS : -MW182 PARAMETER 2
|
|||
|
ZIEL : KS DX
|
|||
|
DB-Z : FW 190
|
|||
|
NACH : FW 192
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : -MW184 PARAMETER 3
|
|||
|
L-B : KS LA
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
Segment 33 Initialize PLI BL560_CHARGE
|
|||
|
:O -M 4.0 GLOBAL AUTO-MODE If no AUTO- and no MANUAL-MODE
|
|||
|
:O -M 4.1 GLOB. MANUAL-MODE then PLI-Interface will be
|
|||
|
: initialisied
|
|||
|
:JC =M001
|
|||
|
:L KF +201
|
|||
|
:T FW 190 => PLI DX 201
|
|||
|
:L KF +200
|
|||
|
:T FW 192 => DW 200
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DX
|
|||
|
DB-Q : -MW180 PARAMETER 1
|
|||
|
VON : -MW182 PARAMETER 2
|
|||
|
BIS : -MW182 PARAMETER 2
|
|||
|
ZIEL : KS DX
|
|||
|
DB-Z : FW 190
|
|||
|
NACH : FW 192
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FB 104 -FB104 STANDARDFLAGS C:ZONE10ST.S5D LEN=624
|
|||
|
Page 12
|
|||
|
LAEN : -MW184 PARAMETER 3
|
|||
|
L-B : KS LA
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
Segment 34 Initialize PLI BL560_MAN_ADD
|
|||
|
:O -M 4.0 GLOBAL AUTO-MODE If no AUTO- and no MANUAL-MODE
|
|||
|
:O -M 4.1 GLOB. MANUAL-MODE then PLI-Interface will be
|
|||
|
: initialisied
|
|||
|
:JC =M001
|
|||
|
:L KF +202
|
|||
|
:T FW 190 => PLI DX 202
|
|||
|
:L KF +0
|
|||
|
:T FW 192 => DW 0
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DX
|
|||
|
DB-Q : -MW180 PARAMETER 1
|
|||
|
VON : -MW182 PARAMETER 2
|
|||
|
BIS : -MW182 PARAMETER 2
|
|||
|
ZIEL : KS DX
|
|||
|
DB-Z : FW 190
|
|||
|
NACH : FW 192
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : -MW184 PARAMETER 3
|
|||
|
L-B : KS LA
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
Segment 35 Initialize PLI BL560_BLEND
|
|||
|
:O -M 4.0 GLOBAL AUTO-MODE If no AUTO- and no MANUAL-MODE
|
|||
|
:O -M 4.1 GLOB. MANUAL-MODE then PLI-Interface will be
|
|||
|
: initialisied
|
|||
|
:JC =M001
|
|||
|
:L KF +202
|
|||
|
:T FW 190 => PLI DX 202
|
|||
|
:L KF +50
|
|||
|
:T FW 192 => DW 50
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DX
|
|||
|
DB-Q : -MW180 PARAMETER 1
|
|||
|
VON : -MW182 PARAMETER 2
|
|||
|
BIS : -MW182 PARAMETER 2
|
|||
|
ZIEL : KS DX
|
|||
|
DB-Z : FW 190
|
|||
|
FB 104 -FB104 STANDARDFLAGS C:ZONE10ST.S5D LEN=624
|
|||
|
Page 13
|
|||
|
NACH : FW 192
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : -MW184 PARAMETER 3
|
|||
|
L-B : KS LA
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
Segment 36 Init PLI BL560_DISCHARGE_NOP
|
|||
|
:O -M 4.0 GLOBAL AUTO-MODE If no AUTO- and no MANUAL-MODE
|
|||
|
:O -M 4.1 GLOB. MANUAL-MODE then PLI-Interface will be
|
|||
|
: initialisied
|
|||
|
:JC =M001
|
|||
|
:L KF +202
|
|||
|
:T FW 190 => PLI DX 202
|
|||
|
:L KF +100
|
|||
|
:T FW 192 => DW 100
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DX
|
|||
|
DB-Q : -MW180 PARAMETER 1
|
|||
|
VON : -MW182 PARAMETER 2
|
|||
|
BIS : -MW182 PARAMETER 2
|
|||
|
ZIEL : KS DX
|
|||
|
DB-Z : FW 190
|
|||
|
NACH : FW 192
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : -MW184 PARAMETER 3
|
|||
|
L-B : KS LA
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
Segment 37 Initialize PLI BL560_DISCHARGE
|
|||
|
:O -M 4.0 GLOBAL AUTO-MODE If no AUTO- and no MANUAL-MODE
|
|||
|
:O -M 4.1 GLOB. MANUAL-MODE then PLI-Interface will be
|
|||
|
: initialisied
|
|||
|
:JC =M001
|
|||
|
:L KF +202
|
|||
|
:T FW 190 => PLI DX 202
|
|||
|
:L KF +150
|
|||
|
:T FW 192 => DW 150
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DX
|
|||
|
DB-Q : -MW180 PARAMETER 1
|
|||
|
VON : -MW182 PARAMETER 2
|
|||
|
BIS : -MW182 PARAMETER 2
|
|||
|
FB 104 -FB104 STANDARDFLAGS C:ZONE10ST.S5D LEN=624
|
|||
|
Page 14
|
|||
|
ZIEL : KS DX
|
|||
|
DB-Z : FW 190
|
|||
|
NACH : FW 192
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : -MW184 PARAMETER 3
|
|||
|
L-B : KS LA
|
|||
|
M001 :BE
|
|||
|
|
|||
|
F 4.0 = M 4.0 GLOBAL AUTO-MODE
|
|||
|
F 4.1 = M 4.1 GLOB. MANUAL-MODE
|
|||
|
FW 180 = MW180 PARAMETER 1
|
|||
|
FW 182 = MW182 PARAMETER 2
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FW 184 = MW184 PARAMETER 3
|
|||
|
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
FB 105 -FB105 KEY SWITCHES C:ZONE10ST.S5D LEN=46
|
|||
|
Page 1
|
|||
|
Segment 1 Betriebsart
|
|||
|
|
|||
|
|
|||
|
erstellt: 06.12.93 HKT
|
|||
|
|
|||
|
-------------------------------------------------------------------------------
|
|||
|
Parameter:
|
|||
|
==========
|
|||
|
|
|||
|
#STEU: Steuerspannung
|
|||
|
#S-PC: Schluesselschalter PC-Automatik
|
|||
|
#S-SP: Schlusselschalter SPS-Automatik
|
|||
|
#A-PC: Ausgang Automatik PC
|
|||
|
#A-SP: Ausgang Automatik SPS
|
|||
|
#Hand: Ausgang Hand
|
|||
|
#Sek1: 1-Sekundenimpuls
|
|||
|
|
|||
|
Name :B-ART
|
|||
|
Decl :STEU I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :S-PC I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :S-SP I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :A-PC I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :A-SP I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :HAND I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :SEK1 I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
|
|||
|
:ON =STEU Steuerspannung
|
|||
|
:ON =SEK1 1-Sekundenimpuls
|
|||
|
:BEC
|
|||
|
:A =S-PC S = Schluesselschalter
|
|||
|
:AN =S-SP
|
|||
|
:= =A-PC Automatic PC
|
|||
|
:
|
|||
|
:A =S-SP
|
|||
|
:AN =S-PC
|
|||
|
:= =A-SP Automatic SPS
|
|||
|
:
|
|||
|
:AN =S-PC
|
|||
|
:AN =S-SP
|
|||
|
:= =HAND Hand
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 106 -FB106 TRANSFER KF->KT C:ZONE10ST.S5D LEN=29
|
|||
|
Page 1
|
|||
|
Segment 1 Anlauf
|
|||
|
|
|||
|
PARAMETER:
|
|||
|
|
|||
|
1. IMP : ZEITIMPULS _________-________________-____________
|
|||
|
1 ZYKLUS LANG 'HIGH'
|
|||
|
|
|||
|
2. AW : AUSGANGSWORT
|
|||
|
3. EW : EINGANGSWORT
|
|||
|
4. FILT : FILTER
|
|||
|
5. S-DW : STOER DATENWORT
|
|||
|
6. OFFS : OFFSET ZUM DATENWORT STOERUNG
|
|||
|
7. FRG : FREIGABE
|
|||
|
8. POS : VERGLEICHSMODUS - 1: EINGANG = AUSGANG
|
|||
|
0: EINGANG = NICHT AUSGANG
|
|||
|
DER VERGLEICHSMODUS GIBT AN, OB DER EINGANG MIT DEM AUSGANG
|
|||
|
KOMMEN MUSS ODER ENTGEGENGESETZT
|
|||
|
|
|||
|
|
|||
|
AUFBAU DES STOERDATENBAUSTEINS:
|
|||
|
|
|||
|
BLOCK 1 : STOERUNGEN AN LEITSYSTEM
|
|||
|
BLOCK 2 : DISKREPANZEN ZWISCHEN E UND A
|
|||
|
BLOCK 3 : ERSTWERTMELDUNG
|
|||
|
BLOCK 4 : FEHLERQUITTUNG
|
|||
|
|
|||
|
|
|||
|
|
|||
|
FUNKTION DES BAUSTEINS:
|
|||
|
=======================
|
|||
|
|
|||
|
1. ZYKLISCHER VERGLEICH VON AUSGANGSWORT UND EINGANGSWORT
|
|||
|
UND ABSPEICHERN DER DISKREPANZ IN BLOCK 2
|
|||
|
|
|||
|
2. BILDUNG DER STOERUNGEN AUS AKTUELLER UND LETZTER DISKREPANZ
|
|||
|
|
|||
|
3. RUECKSETZEN DER STOERUNGEN, WENN KEINE DISKREPANZ ZWISCHEN E UND A
|
|||
|
UND EINE QUITTUNG VORLIEGT
|
|||
|
Name :KF->KT
|
|||
|
Decl :EINH I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :EING I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :AUSG I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
|
|||
|
:
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2 Anlaufmerker setzen
|
|||
|
:L =EING
|
|||
|
:DUF
|
|||
|
:LW =EINH
|
|||
|
:SLW 12
|
|||
|
:OW
|
|||
|
:T =AUSG
|
|||
|
:
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 107 -FB107 LEVEL INDICATORS C:ZONE10ST.S5D LEN=88
|
|||
|
Page 1
|
|||
|
Segment 1 DREHFLUEGELMELDER
|
|||
|
|
|||
|
|
|||
|
erstellt: Herkert 17.06.94
|
|||
|
|
|||
|
|
|||
|
----------------------------------------------------------------------------
|
|||
|
|
|||
|
FUNKTIONEN DES BAUSTEINS:
|
|||
|
========================
|
|||
|
|
|||
|
- ZEITLICHE ENTKOPPLUNG VON DREHFLUGELMELDERN / DEFINITIVE MELDUNG
|
|||
|
- QUITTIERBARE ERSTWERTMELDUNG FUER DARSTELLUNG AUF FARBGRAPHIK ETC.
|
|||
|
- LEERMELDUNG WIRD AUF EINGANG ZURUECKGEFUEHRT, SO DASS DIESER WIE
|
|||
|
NORMALER MELDER ABGEFRAGT WERDEN KANN.
|
|||
|
DER FB SOLL AM ANFANG DES ZYKLISCHEN PROGRAMMES AUFGERUFEN WERDEN,
|
|||
|
DAMIT DIE EINGANGE VOR DER ERSTEN ABFRAGE ENTKOPPELT WERDEN.
|
|||
|
|
|||
|
-----------------------------------------------------------
|
|||
|
Testaufbau : PB112
|
|||
|
-----------------------------------------------------------
|
|||
|
|
|||
|
Parameter:
|
|||
|
=========
|
|||
|
|
|||
|
EW : Eingangswort
|
|||
|
FOLG: Bitleiste, die dem Eingangswort folgt
|
|||
|
MELD: entkoppelter Melder
|
|||
|
ERST: Erstwertmeldung
|
|||
|
TAKT: __________-_____________-_____________ Zyklischer Impuls
|
|||
|
FILT: bestimmt, welche Bits im EW entkoppelt werden
|
|||
|
P-N : 1 = Erstwertmeldung bei positiver Flanke
|
|||
|
0 = Erstwertmeldung bei negativer Flanke
|
|||
|
|
|||
|
|
|||
|
T : _____-_____-_____-_____-_____-_____-_____-____
|
|||
|
EW : ____-----------_________________
|
|||
|
EW-FOLGE :
|
|||
|
Entkoppl. Entkoppl.
|
|||
|
!<----->! !<----->!
|
|||
|
MELDUNG : ___________------------_________
|
|||
|
|
|||
|
ERSTWERTMELDUNG:
|
|||
|
QUITTUNG :
|
|||
|
|
|||
|
Name :SILOMELD DREHFLUEGELMELDER
|
|||
|
Decl :EW I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :FOLG I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :MELD I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :ERST I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :TAKT I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :FILT I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KM
|
|||
|
Decl :P-N I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KM
|
|||
|
|
|||
|
:A =TAKT
|
|||
|
:JC =M001
|
|||
|
:L =EW ________________________________
|
|||
|
:L =FOLG
|
|||
|
:OW
|
|||
|
:L =MELD
|
|||
|
:AW
|
|||
|
:T FW 220
|
|||
|
:
|
|||
|
:L =EW
|
|||
|
FB 107 -FB107 LEVEL INDICATORS C:ZONE10ST.S5D LEN=88
|
|||
|
Page 2
|
|||
|
:L =FOLG
|
|||
|
:AW
|
|||
|
:L FW 220
|
|||
|
:OW
|
|||
|
:T =FOLG
|
|||
|
:JU =M002
|
|||
|
M001 :L =MELD
|
|||
|
:L =FOLG
|
|||
|
:T =MELD
|
|||
|
:TAK
|
|||
|
:XOW
|
|||
|
:L =ERST
|
|||
|
:OW
|
|||
|
:LW =FILT
|
|||
|
:AW
|
|||
|
:T =ERST
|
|||
|
:
|
|||
|
:L =MELD
|
|||
|
:CFW
|
|||
|
:LW =P-N
|
|||
|
:XOW
|
|||
|
:L =ERST
|
|||
|
:AW
|
|||
|
:LW =FILT
|
|||
|
:AW
|
|||
|
:T =ERST
|
|||
|
:
|
|||
|
:L =EW
|
|||
|
:T =FOLG
|
|||
|
M002 :
|
|||
|
:L =EW
|
|||
|
:LW =FILT
|
|||
|
:CFW
|
|||
|
:AW ERSTWERTMELDUNG
|
|||
|
:T FW 224
|
|||
|
:
|
|||
|
:L =MELD NEUE EINGANGSWORTFOLGE
|
|||
|
:LW =FILT
|
|||
|
:AW ________________________________
|
|||
|
:T =MELD
|
|||
|
: EINGAENGE ENTKOPPELN
|
|||
|
:L =MELD
|
|||
|
:L FW 224
|
|||
|
:OW
|
|||
|
:T =EW
|
|||
|
:
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 108 -FB108 TIMER IMITATION C:ZONE10ST.S5D LEN=105
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
FB 108 - TIMERNACHBILDUNG SE/SA STAND: 22.10.97
|
|||
|
===============================================================================
|
|||
|
***** CPU : ALLE *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : 18.03.93 K.WEBER
|
|||
|
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG :
|
|||
|
|
|||
|
NR. DATUM AENDERUNG BEARBEITER
|
|||
|
-------------------------------------------------------------------------------
|
|||
|
01 22.10.97 N4 (1) UR
|
|||
|
===============================================================================
|
|||
|
SYMBOLIKDATEI : KEINE
|
|||
|
---------------
|
|||
|
|
|||
|
BAUSTEINPARAMETER :
|
|||
|
-------------------
|
|||
|
#STRT : STARTBIT FUER TIMER
|
|||
|
#AKTI : ZEIT LAEUFT (SIEHE EIN-/AUSSCHALTVERZOEGERUNG)
|
|||
|
#AUSG : TIMERAUSGANG
|
|||
|
#TTYP : SE = EINSCHALTVERZ. SA = AUSSCHALTVERZ.
|
|||
|
#SOLL : SOLLZEIT
|
|||
|
#IST : ISTZEIT
|
|||
|
#IMP : IMPULS DER ZEITBASIS (IMPULS = 1 ZYKLUS LANG)
|
|||
|
|
|||
|
|
|||
|
LOKALE VARIABLEN :
|
|||
|
------------------
|
|||
|
KEINE VERWENDET
|
|||
|
|
|||
|
Name :TIMER
|
|||
|
Decl :STRT I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :RSET I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :AKTI I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :AUSG I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :TTYP I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KS
|
|||
|
Decl :SOLL I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :IST I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :IMP I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2 TIMER RESET
|
|||
|
:AN =RSET Bei Ansteuerung des Reset
|
|||
|
:JC =M001 Einganges wird der Timerausgang
|
|||
|
:RB =AUSG und das Timer Aktivsignal
|
|||
|
:RB =AKTI zurueckgesetzt.
|
|||
|
:
|
|||
|
:L KF +0 Die bereits abgelaufene Zeit
|
|||
|
:T =IST wird zurueckgesetzt.
|
|||
|
:
|
|||
|
:BEU Der Baustein wird nicht mehr
|
|||
|
: weiter bearbeitet.
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 3 Einschaltverzoegerung
|
|||
|
|
|||
|
|
|||
|
FB 108 -FB108 TIMER IMITATION C:ZONE10ST.S5D LEN=105
|
|||
|
Page 2
|
|||
|
Einschaltverzoegerung :
|
|||
|
__________
|
|||
|
STRT : __! !__
|
|||
|
____
|
|||
|
AKTI : __! !________
|
|||
|
_____
|
|||
|
AUSG : _______! !__
|
|||
|
|
|||
|
|
|||
|
:LW =TTYP Abfrage ob Einschaltverzoegerung
|
|||
|
:L KS SE angewaehlt
|
|||
|
:><F
|
|||
|
:JC =M001 Wenn ja, und
|
|||
|
:L =SOLL Zeitsollwert ist groesser als
|
|||
|
:L =IST Zeitistwert und
|
|||
|
:>F
|
|||
|
:A =STRT Startsignal steht an, dann
|
|||
|
:= =AKTI signalisiere 'Zeit ist aktiv'
|
|||
|
:
|
|||
|
:A =STRT Wenn Zeit abgelaufen und Start
|
|||
|
:AN =AKTI steht noch an, dann wird Ausgang
|
|||
|
:= =AUSG freigegeben.
|
|||
|
:
|
|||
|
:L KF +0 Istzeit wird erst geloescht
|
|||
|
:ON =STRT wenn Startsignal von 1 nach 0
|
|||
|
:JC =M002 wechselt
|
|||
|
:ON =AKTI Wenn die Zeit aktiv ist und
|
|||
|
:ON =IMP ein ext. Zeitimpuls ansteht,
|
|||
|
:JC =M001 dann wird
|
|||
|
:L =IST die Istzeit um
|
|||
|
:L KF +1 einen Zeitwert
|
|||
|
:+F erhoeht.
|
|||
|
M002 :T =IST
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 4 Ausschaltverzoegerung
|
|||
|
|
|||
|
22.10.97 UR - (1) IST-DATENWORT LOESCHEN WENN START NICHT MEHR ANSTEHT
|
|||
|
|
|||
|
Ausschaltverzoegerung :
|
|||
|
___________
|
|||
|
STRT : _! !_____
|
|||
|
___
|
|||
|
AKTI : _____________! !_
|
|||
|
_______________
|
|||
|
AUSG : _! !_
|
|||
|
|
|||
|
|
|||
|
:LW =TTYP Abfrage ob Ausschaltverzoegerung
|
|||
|
:L KS SA angewaehlt
|
|||
|
:><F
|
|||
|
:JC =M001 Wenn ja, und
|
|||
|
:L =SOLL Zeitsollwert ist groesser als
|
|||
|
:L =IST Zeitistwert und
|
|||
|
:>F
|
|||
|
:A =AUSG Ausgangssignal gesetzt und nicht
|
|||
|
:AN =STRT Startsignal angelegt dann
|
|||
|
:= =AKTI signalisiere Zeit aktiv
|
|||
|
:
|
|||
|
:O =STRT Wenn Startsignal anliegt oder
|
|||
|
:O =AKTI Zeit aktiv meldet dann wird
|
|||
|
:= =AUSG Ausgang ausgegeben
|
|||
|
:
|
|||
|
FB 108 -FB108 TIMER IMITATION C:ZONE10ST.S5D LEN=105
|
|||
|
Page 3
|
|||
|
:L KF +0 Wenn Ausgang = 0 dann wird
|
|||
|
:ON =AUSG Istzeit mit 0 initialisiert
|
|||
|
:O =STRT (1)
|
|||
|
:JC =M002
|
|||
|
:ON =AKTI Wenn die Zeit aktiv ist und ein
|
|||
|
:ON =IMP ext. Zeitimpuls ansteht
|
|||
|
:JC =M001 dann wird die
|
|||
|
:L =IST Istzeit um
|
|||
|
:L KF +1 einen Zeitwert
|
|||
|
:+F erhoeht.
|
|||
|
M002 :T =IST
|
|||
|
M001 :BE
|
|||
|
|
|||
|
|
|||
|
FB 109 -FB109 LUMINOUS PUSH-BUT C:ZONE10ST.S5D LEN=37
|
|||
|
Page 1
|
|||
|
Segment 1 Leuchttaster
|
|||
|
|
|||
|
|
|||
|
erstellt: 06.11.1992 Herkert
|
|||
|
|
|||
|
Parameter:
|
|||
|
=========
|
|||
|
|
|||
|
# Eing: Eingang
|
|||
|
# Ausg: Ausgang Lampe
|
|||
|
# Folg: Folgemerker zur Impulsauswertung
|
|||
|
# Rese: Reset zum externen Ruecksetzen des Ausgangs
|
|||
|
|
|||
|
|
|||
|
Funktion:
|
|||
|
=========
|
|||
|
|
|||
|
Eingang UN Ausgang -> Ausgang setzen
|
|||
|
|
|||
|
Eingang U Ausgang -> Ausgang ruecksetzen
|
|||
|
|
|||
|
Reset -> Ausgang ruecksetzen
|
|||
|
|
|||
|
Name :L-TAST
|
|||
|
Decl :EING I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :AUSG I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :FOLG I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :RESE I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
|
|||
|
:AN =AUSG
|
|||
|
:JC =M001
|
|||
|
:A =EING
|
|||
|
:AN =FOLG
|
|||
|
:RB =AUSG
|
|||
|
:JU =M002
|
|||
|
M001 :A =EING
|
|||
|
:AN =FOLG
|
|||
|
:S =AUSG
|
|||
|
M002 :
|
|||
|
:A =EING
|
|||
|
:= =FOLG
|
|||
|
:A =RESE Externer Reset
|
|||
|
:RB =AUSG
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 110 -FB110 PIPE DIVERTER C:ZONE10ST.S5D LEN=65
|
|||
|
Page 1
|
|||
|
Segment 1 Rohrweiche mit 2 Ausg./2 Eing.
|
|||
|
Name :RW
|
|||
|
Decl :V-OK I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :N1A1 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :N1A2 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :N2A1 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :N2A2 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :A1 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :E1 I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :A2 I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :E2 I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :RWOK I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :FREI I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
|
|||
|
:A =V-OK Vorgaenger ok
|
|||
|
:A(
|
|||
|
:A =A1 01 Ausgang 1
|
|||
|
:A =E1 01 Eingang 1
|
|||
|
:O 01
|
|||
|
:A =A2 01 Ausgang 2
|
|||
|
:A =E2 01 Eingang 2
|
|||
|
:) 01
|
|||
|
:= =RWOK Rohrweiche ok
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 2 Ausgaenge ansteuern
|
|||
|
:O =N1A1 Nachfolger 1 Ausgang 1
|
|||
|
:O =N1A2 Nachfolger 1 Ausgang 2
|
|||
|
:= =A1
|
|||
|
:
|
|||
|
:O =N2A1 Nachfolger 2 Ausgang 1
|
|||
|
:O =N2A2 Nachfolger 2 Ausgang 2
|
|||
|
:= =A2
|
|||
|
:
|
|||
|
:AN =A1
|
|||
|
:AN =A2
|
|||
|
:= =FREI Rohrweiche frei
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 111 -FB111 TABLE INDICATORS C:ZONE10ST.S5D LEN=188
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
***********************************************************
|
|||
|
**** F I L T E R S T E U E R U N G MAX. 10 VENTILE ****
|
|||
|
***********************************************************
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
PARAMETER: FRG : FREIGABE NORMALBETRIEB
|
|||
|
---------- ZAEH: ZAEHLERBYTE FUER FILTERTASCHENSTAND
|
|||
|
MOEGLICHE ANGABEN: DL,DR,MB,AB
|
|||
|
MAX : FESTPUNKTZAHL FUER MAXIMALE ANZAHL DER VENTILE
|
|||
|
TIMP: TIMER FUER IMPULSZEIT
|
|||
|
TPAU: TIMER FUER PAUSENZEIT
|
|||
|
DWIP: WORT MIT DEM IMPULSWERT FUER NORMALBETRIEB
|
|||
|
DWPA: WORT MIT DEM PAUSENWERT FUER NORMALBETRIEB
|
|||
|
A1 : AUSGANG 1 FUER VENTIL 1
|
|||
|
A2 : AUSGANG 2 FUER VENTIL 2
|
|||
|
. -"-
|
|||
|
. -"-
|
|||
|
A10 : AUSGANG 10 FUER VENTIL 10
|
|||
|
GEST: HILFSMERKER FUER FILTERSTEUERUNG GESTARTET
|
|||
|
(KEIN SCHMIERMERKER BENUTZEN)
|
|||
|
FIFE: HILFSMERKER FUER EINZELTASCHE GEREINIGT
|
|||
|
(KEIN SCHMIERMERKER BENUTZEN)
|
|||
|
DWI : WORT MIT DEM IMPULSWERT FUER ENTLEERZYKLUS
|
|||
|
DWP : WORT MIT DEM PAUSENWERT FUER ENTLEERZYKLUS
|
|||
|
ELZY: FREIGABE ENTLEERZYKLUSBETRIEB
|
|||
|
ELZG: AUSGANG ENTLEERZYKLUS GESTARTET
|
|||
|
(KEIN SCHMIERMERKER)
|
|||
|
ELZE: AUSGANG ENTLEERZYKLUS AM ENDE
|
|||
|
|
|||
|
|
|||
|
|
|||
|
FUNKTIONSWEISE NORMALBETRIEB
|
|||
|
----------------------------
|
|||
|
|
|||
|
SOBALD DIE FREIGABE ERTEILT WIRD LAEUFT DIE PAUSENZEIT AN. DER ZAEHLERSTAND
|
|||
|
WIRD BEIM ERSTEN BETRIEB AUF 1 GESETZT. NACHDEM DIE PAUSENZEIT ABGELAUFEN IST
|
|||
|
STARTET DIE IMPULSZEIT. GLEICHZEITIG IST DER IM ZAEHLER NOTIERTE FILTERAUSGANG
|
|||
|
GESETZT. NACH ABLAUF DER IMPULSZEIT IST DAS SIGNAL "FIFE" EIN ZYKLUS LANG 1 UND
|
|||
|
FUEHRT ZUR ERHOEHUNG DES ZAEHLERS UM 1 UND SETZT DIE PAUSENZEIT UND VENTIL ZU-
|
|||
|
RUECK. DARAUFHIN BEGINNT DER VORGANG ERNEUT MIT FILTER 2 .
|
|||
|
|
|||
|
BEI JEDER ERHOEHUNG WIRD GEPRUEFT, OB DER MAXIMAL VORGEGEBENE WERT SCHON ER-
|
|||
|
REICHT IST. WENN JA, ERFOLGT DIE ZAEHLUNG ERNEUT VON 1.
|
|||
|
|
|||
|
DAS SIGNAL "GEST" WIRD FUER EINE NOCHMALIGE BEARBEITUNG DES FB BENOETIGT, WENN
|
|||
|
DIE FREIGABE WEGGENOMMEN WIRD, UM ALLE SIGNALZUSTAENDE IM FB ZU LOESCHEN.
|
|||
|
|
|||
|
NACH ERNEUTER ERTEILUNG DER FREIGABE WIRD MIT DER ABREINIGUNG DES ZULETZT BE-
|
|||
|
ARBEITETEN FILTERS FORTGEFAHREN, UM BEI HAEUFIGEM SCHALTEN FUER DIE ABREINIGUNG
|
|||
|
ALLER FILTERTASCHEN ZU SORGEN.
|
|||
|
|
|||
|
|
|||
|
|
|||
|
FUNKTIONSWEISE ENTLEERZYKLUS
|
|||
|
-----------------------------
|
|||
|
|
|||
|
DER ABLAUF DER FILTERABREINIGUNG VERHAELT SICH WIE BEIM NORMALBETRIEB, WOBEI
|
|||
|
FB 111 -FB111 TABLE INDICATORS C:ZONE10ST.S5D LEN=188
|
|||
|
Page 2
|
|||
|
JEDOCH BEI START DES ENTLEERZYKLUS IMMER MIT DEM ERSTEN VENTIL BEGONNEN WIRD.
|
|||
|
NACH DER ABREINIGUNG DES LETZTEN VENTILS IST DER ENTLEERBETRIEB ABGESCHLOSSEN,
|
|||
|
D.H. DIE FILTER WERDEN NUR EINMAL GEREINIGT.
|
|||
|
|
|||
|
BEI START WIRD DAS SIGNAL ENTLEERBETRIEB GESTARTET AUSGEGEBEN UND AM ENDE
|
|||
|
DAS SIGNAL ENTLEERZYKLUS BEENDET.
|
|||
|
|
|||
|
|
|||
|
ANWENDUNGSBEREICH
|
|||
|
-----------------
|
|||
|
|
|||
|
- BEI FILTERREINIGUNGEN UEBER DIE SPS MIT MEHR ALS EINER FILTERTASCHE
|
|||
|
- FUER SILOBETROCKNUNG MEHRERER SILOS NACHEINANDER UEBER ZEIT WOBEI
|
|||
|
DIE PAUSENZEIT SEHR KURZ GEWAEHLT WERDEN KANN.
|
|||
|
- SCHIEBEREGISTER
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Name :FILTERST AZO FILTERSTEUERUNG
|
|||
|
Decl :FRG I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :ZAEH I/Q/D/B/T/C: I BI/BY/W/D: BY
|
|||
|
Decl :MAX I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :TIMP I/Q/D/B/T/C: T
|
|||
|
Decl :TPAU I/Q/D/B/T/C: T
|
|||
|
Decl :DWIP I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :DWPA I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :A1 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :A2 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :A3 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :A4 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :A5 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :A6 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :A7 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :A8 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :A9 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :A10 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :GEST I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :FIFE I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :DWI I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :DWP I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :ELZY I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :ELZE I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :ELZG I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
|
|||
|
:AN =ELZY KEIN ENTLEERZYKLUS MEHR
|
|||
|
:RB =ELZE ENTLEERZYKLUS ENDE RUECKSETZEN
|
|||
|
:RB =ELZG ENTLEERZYKLUS GESTARTET RUECKSET
|
|||
|
:AN =ELZY KEIN ENTLEERZYKLUS
|
|||
|
:AN =GEST NICHT MEHR AKTIV
|
|||
|
:AN =FRG NICHT MEHR FREIGEGEBEN
|
|||
|
:BEC PROGRAMM VERLASSEN
|
|||
|
:AN =ELZY -- PAUSENYZEIT UEBERGEBEN --
|
|||
|
:JC =M001
|
|||
|
:L =DWP PAUSE ENTLEERZYKLUS
|
|||
|
:JU =M002
|
|||
|
M001 :L =DWPA PAUSE NORMALBETRIEB
|
|||
|
M002 :A(
|
|||
|
:A =FRG 01 FREIGABE ERTEILT
|
|||
|
:O 01
|
|||
|
:A =ELZY 01 ENTLEERZYKLUSBETRIEB
|
|||
|
:AN =ELZE 01 ENTLEERZYKLUS AM ENDE
|
|||
|
:) 01
|
|||
|
:AN =FIFE
|
|||
|
:SD =TPAU PAUSENZEIT STARTEN
|
|||
|
FB 111 -FB111 TABLE INDICATORS C:ZONE10ST.S5D LEN=188
|
|||
|
Page 3
|
|||
|
:AN =ELZY -- IMPULSZEIT UEBERGEBEN --
|
|||
|
:JC =M003
|
|||
|
:L =DWI IMPULS ENTLEERZYKLUS
|
|||
|
:JU =M004
|
|||
|
M003 :L =DWIP IMPULS NORMALBETRIEB
|
|||
|
M004 :A =TPAU
|
|||
|
:SD =TIMP
|
|||
|
:A =TIMP
|
|||
|
:= =FIFE
|
|||
|
:L =ZAEH ZAEHLER GLEICH NULL?
|
|||
|
:L KF +0 WENN JA, SPRUNG ZU
|
|||
|
:!=F
|
|||
|
:JC =M005 ZAEHLER ERHOEHEN
|
|||
|
:L FW 200 MW200 IN AKKU SICHERN
|
|||
|
:L =ZAEH
|
|||
|
:T FW 200
|
|||
|
:A =TPAU
|
|||
|
:AN =FIFE
|
|||
|
:DO FW 200
|
|||
|
M006 :JU =M006
|
|||
|
:JU =M007 VENTIL 1
|
|||
|
:JU =M008 VENTIL 2
|
|||
|
:JU =M009 VENTIL 3
|
|||
|
:JU =M010 VENTIL 4
|
|||
|
:JU =M011 VENTIL 5
|
|||
|
:JU =M012 VENTIL 6
|
|||
|
:JU =M013 VENTIL 7
|
|||
|
:JU =M014 VENTIL 8
|
|||
|
:JU =M015 VENTIL 9
|
|||
|
:JU =M016 VENTIL 10
|
|||
|
M007 := =A1 == VENTILE ZUWEISEN ==
|
|||
|
:JU =M017
|
|||
|
M008 := =A2
|
|||
|
:JU =M017
|
|||
|
M009 := =A3
|
|||
|
:JU =M017
|
|||
|
M010 := =A4
|
|||
|
:JU =M017
|
|||
|
M011 := =A5
|
|||
|
:JU =M017
|
|||
|
M012 := =A6
|
|||
|
:JU =M017
|
|||
|
M013 := =A7
|
|||
|
:JU =M017
|
|||
|
M014 := =A8
|
|||
|
:JU =M017
|
|||
|
M015 := =A9
|
|||
|
:JU =M017
|
|||
|
M016 := =A10
|
|||
|
M017 :TAK
|
|||
|
:T FW 200
|
|||
|
:O =FRG GESTARTET SIGNAL LOESCHEN
|
|||
|
:O =ELZY ENTLEERZYKLUS
|
|||
|
:= =GEST
|
|||
|
:AN =FIFE FILTERTASCHE GEREINIGT, NEUE
|
|||
|
:BEC UND NEUE FILTER FIXIEREN
|
|||
|
M005 :AN =ELZY KEIN ENTLEERZYKLUS
|
|||
|
:JC =M018
|
|||
|
:A( WENN ZAEHLER UND MAX IDENTISCH
|
|||
|
:L =ZAEH 01 UND ENTLEERZYKLUS WAR GESTARTET
|
|||
|
:LW =MAX 01 DANN ENTLEERZYKLUS AM ENDE
|
|||
|
:>=F 01
|
|||
|
:) 01
|
|||
|
:A =ELZG ENDEKENNUNG SETZEN
|
|||
|
FB 111 -FB111 TABLE INDICATORS C:ZONE10ST.S5D LEN=188
|
|||
|
Page 4
|
|||
|
:S =ELZE
|
|||
|
:BEC
|
|||
|
:A =ELZG ENTLEERZYKLUS GESTARTET
|
|||
|
:JC =M018
|
|||
|
:L KF +0
|
|||
|
:T =ZAEH
|
|||
|
:AN =ELZG
|
|||
|
:S =ELZG
|
|||
|
M018 :
|
|||
|
:L =ZAEH ZAEHLER LADEN
|
|||
|
:LW =MAX REICHT, WENN JA , DANN AUF NULL
|
|||
|
:<F SETZEN UND WEITER ZU ZAEHLER
|
|||
|
:JC =M019 ERHOEHEN.
|
|||
|
:L KF +0
|
|||
|
:T =ZAEH
|
|||
|
M019 :L =ZAEH ZAEHLER UM 1 ERHOEHEN
|
|||
|
:I 1
|
|||
|
:T =ZAEH
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 112 -FB112 CLOCK GENERATOR ( C:ZONE10ST.S5D LIB=106 LEN=152
|
|||
|
Page 1
|
|||
|
Segment 1 Taktgenerator
|
|||
|
|
|||
|
|
|||
|
T A K T B A U S T E I N mit Rueckmeldung
|
|||
|
===========================================
|
|||
|
|
|||
|
-----------------------------------------------------------------------
|
|||
|
erstellt: 04.12.94 HKT
|
|||
|
-----------------------------------------------------------------------
|
|||
|
|
|||
|
|
|||
|
Parameter:
|
|||
|
==========
|
|||
|
|
|||
|
1 #FRG : Freigabe
|
|||
|
2 #DWIM : Impuls - Zeitwert
|
|||
|
3 #DWPA : Pause - Zeitwert
|
|||
|
4 #AUSG : Taktausgang
|
|||
|
5 #POS : 1 = positiver Start / 0 = negativer Start
|
|||
|
6 #DB : Datenbaustein
|
|||
|
7 #RM : Rueckmeldung #RM muss gleich #AUSG sein
|
|||
|
8 #IN : =KC 'IN' bei indirekter Adressierung
|
|||
|
9 #Takt : Sekundenimpuls
|
|||
|
10 #SOLL : Anzahl der Takte, 0 = Dauertakt
|
|||
|
11 #IST : Taktanzahl Istwert
|
|||
|
12 #FERT : Soll-Taktzahl erreicht
|
|||
|
13 #BITL : Code 1 aus 16 der Variablen #IST -> Bsp.: 3 = 0000000 00000100
|
|||
|
14 #DAUE : wenn = 1 dann Dauertakt; wenn = 0 dann Takt bis Ist = Soll
|
|||
|
15 #Akti : Timer aktiv
|
|||
|
|
|||
|
-----------------------------------------------------------------------------
|
|||
|
|
|||
|
Name :TAKT
|
|||
|
Decl :FREI I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :DWIS I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :DWIM I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :DWPA I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :AUSG I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :POS I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :DB I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :RM I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :TAKT I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :MAX I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :IST I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :FERT I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :BITL I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :DAUE I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :AKTI I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
|
|||
|
:L =DB
|
|||
|
:T FW 200
|
|||
|
:DO FW 200
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 2 Startvoraussetzungen
|
|||
|
:A =FREI
|
|||
|
:JC =M001
|
|||
|
:L KF +0
|
|||
|
:T =DWIS
|
|||
|
:T =IST
|
|||
|
FB 112 -FB112 CLOCK GENERATOR ( C:ZONE10ST.S5D LIB=106 LEN=152
|
|||
|
Page 2
|
|||
|
:AN =FREI
|
|||
|
:RB =AUSG
|
|||
|
:RB =FERT
|
|||
|
:RB =AKTI
|
|||
|
:L KF +0
|
|||
|
:T =BITL
|
|||
|
M001 :
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 3 Start Initialisierung
|
|||
|
:A =FREI
|
|||
|
:AN =AKTI
|
|||
|
:A =POS
|
|||
|
:S =AUSG
|
|||
|
:
|
|||
|
:A =FREI
|
|||
|
:= =AKTI
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 4 Pause
|
|||
|
:ON =TAKT
|
|||
|
:O =FERT
|
|||
|
:O =AUSG
|
|||
|
:O =RM
|
|||
|
:JC =M001
|
|||
|
:L =DWIS
|
|||
|
:L KF +1
|
|||
|
:+F
|
|||
|
:T =DWIS
|
|||
|
:L =DWPA
|
|||
|
:>=F
|
|||
|
:RB =AUSG
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:L KF +0
|
|||
|
:T =IST
|
|||
|
M001 :
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 5 Impuls
|
|||
|
:ON =TAKT
|
|||
|
:ON =AUSG
|
|||
|
:O =FERT
|
|||
|
:ON =RM
|
|||
|
:JC =M001
|
|||
|
:L =DWIS Impuls
|
|||
|
:L KF +1 Rueckmeldung ?
|
|||
|
:+F
|
|||
|
:T =DWIS
|
|||
|
:L =DWIM
|
|||
|
:>=F
|
|||
|
:RB =AUSG
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:L KF +0
|
|||
|
:T =DWIS
|
|||
|
:L =IST
|
|||
|
:L KF +1
|
|||
|
:+F
|
|||
|
:T =IST Impulszaehler erhoehen
|
|||
|
:L =MAX
|
|||
|
FB 112 -FB112 CLOCK GENERATOR ( C:ZONE10ST.S5D LIB=106 LEN=152
|
|||
|
Page 3
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:AN =DAUE
|
|||
|
:S =FERT
|
|||
|
:JC =M001
|
|||
|
:L KF +0 Dauertakt ?
|
|||
|
:T =IST Fertig - Sollimpulse erreicht
|
|||
|
M001 :
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 6 Bitleiste ausgeben
|
|||
|
:AN =AUSG
|
|||
|
:L KF +0
|
|||
|
:JC =M001
|
|||
|
:L =IST
|
|||
|
:D 1
|
|||
|
:T FW 250
|
|||
|
:L KM 00000000 00000001
|
|||
|
:DO FW 250
|
|||
|
:SLW 0
|
|||
|
M001 :
|
|||
|
:T =BITL
|
|||
|
:
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 113 -FB113 CLOCK GENERAT.TIM C:ZONE10ST.S5D LIB=106 LEN=318
|
|||
|
Page 1
|
|||
|
Segment 1 TAKTGENERATOR
|
|||
|
|
|||
|
FB 113 TAKTBAUSTEIN STAND : 16.09.96
|
|||
|
===============================================================================
|
|||
|
***** CPU : ALLE CPU'S *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : 31.11.92 HERKERT
|
|||
|
(HKT)
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG :
|
|||
|
|
|||
|
NR. DATUM AENDERUNG BEARBEITER
|
|||
|
-------------------------------------------------------------------------------
|
|||
|
01 31.01.94 INDIREKTE ADRESSIERUNG HKT
|
|||
|
VORGABGE TAKTZAHL
|
|||
|
02 28.06.94 AUSGABE BITLEISTE HKT
|
|||
|
03 17.09.96 AENDERUNG INDIREKTE ADRESSIERUNG; DOKUMENTATION UR
|
|||
|
===============================================================================
|
|||
|
SYMBOLIKDATEI : KEINE
|
|||
|
----------------------
|
|||
|
|
|||
|
BAUSTEINPARAMETER :
|
|||
|
--------------------
|
|||
|
#FRG : FREIGABE DES TAKTES
|
|||
|
#T : TIMRE NR.
|
|||
|
#DWIM : ZEITWERT FUER IMPULS
|
|||
|
#DWPA : ZEITWERT FUER PAUSE
|
|||
|
#AUSG : TAKTAUSGANG
|
|||
|
#POS : 1 = POSITIVER START / 0 = NEGATIVER START
|
|||
|
#DBT : DATENBAUSTEIN FUER ZEITWERTE BEI DIREKTER ADRESSIERUNG
|
|||
|
#RM : RUECKMELDUNG FUER TAKTAUSGANG
|
|||
|
#T-IN : TIMER-NR, BEI INDIREKTER ADRESSIERUNG
|
|||
|
#IN : = KC 'IN' BAUSTEIN WIRD INDIREKT BEARBEITET
|
|||
|
#SOLL : ANZAHL TAKTE, 0 = DAUERTAKT
|
|||
|
#IST : ANZAHL TAKTE ISTWERT
|
|||
|
#FERT : ANZAHL TAKTE ERREICHT
|
|||
|
#BITL : AUSGABE VON #IST ALS BITLEISTE -> BSP.: 3 = 0000000 00000100
|
|||
|
#DAUE : 1 = DAUERTAKT; 0 = TAKTE BIS #IST = #SOLL (NUR RELEVANT WENN #SOLL<>0)
|
|||
|
#DBST : STATUS-DB FUER #IST UND #BITL BEI DIREKTER ADRESSIERUNG
|
|||
|
|
|||
|
|
|||
|
LOKALE VARIABLEN :
|
|||
|
-------------------
|
|||
|
BAUSTEIN WIRD DIREKT PARAMETRIERT : MW250
|
|||
|
BAUSTEIN WIRD INDIREKT PARAMETRIERT : MW250
|
|||
|
|
|||
|
FUNKTION :
|
|||
|
-----------
|
|||
|
DIREKTE ADRESSIERUNG :
|
|||
|
DIE PARAMETER #DWIM UND #DWPA WERDEN AUS DEM BAUSTEIN DER DURCH #DBT FESTGELEGT
|
|||
|
IST GELADEN. DER TIMER WIRD DURCH #T FESTGELEGT.
|
|||
|
DIE PARAMETER #IST UND #BITL WERDEN AUS DEM BAUSTEIN DER DURCH #DBST FESTGELEGT
|
|||
|
IST GELADEN.
|
|||
|
|
|||
|
INDIREKTE ADRESSIERUNG :
|
|||
|
DIE PARAMETER #DWIM, #DWPA, #T-IN, #IST, #BITL WERDEN AUS DEM BAUSTEIN GELADEN
|
|||
|
DER BEIM AUFRUF DES FB'S AKTIV IST (#DBT UND #DBST HABEN KEINEN EINFLUSS)
|
|||
|
|
|||
|
ALLGEMEIN :
|
|||
|
PARAMETER #SOLL - 0 => DAUERTAKT WIRD ERZEUGT
|
|||
|
ANZAHL => WENN #DAUE=0 WIRD TAKT ERZEUGT BIS #IST=#SOLL
|
|||
|
WENN #DAUE=1 WIRD DAUERTAKT ERZEUGT. #BITL GEHT
|
|||
|
FB 113 -FB113 CLOCK GENERAT.TIM C:ZONE10ST.S5D LIB=106 LEN=318
|
|||
|
Page 2
|
|||
|
NUR BIS #SOLL UND FAENGT DANN WIEDER BEI 1 AN.
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Name :TAKT
|
|||
|
Decl :FRG I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :T I/Q/D/B/T/C: T
|
|||
|
Decl :DWIM I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :DWPA I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :AUSG I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :POS I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :DBT I/Q/D/B/T/C: B
|
|||
|
Decl :RM I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :T-IN I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :IN I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KS
|
|||
|
Decl :SOLL I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :IST I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :FERT I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :BITL I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :DAUE I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :DBST I/Q/D/B/T/C: B
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
Segment 2 DIREKTE ADRESSIERUNG
|
|||
|
:LW =IN
|
|||
|
:L KS IN
|
|||
|
:!=F INDIREKTE ADRESSIERUNG ?
|
|||
|
:JC =M001 JA -> NETZWERK NICHT BEARB.
|
|||
|
: NEIN -> NETZWERK WIRD BEARB.
|
|||
|
:DO =DBT +- TIMER-DB LADEN
|
|||
|
:
|
|||
|
:L =DWIM +- ZEITBASIS UEBERPRUEFEN
|
|||
|
:SRW 12 |
|
|||
|
:L KH 0000 |
|
|||
|
:><F |
|
|||
|
:JC =M002 |
|
|||
|
:L =DWIM | AUS ZEITBASIS .0
|
|||
|
:SRW 4 | ZEITBASIS .1 HERSTELLTEN
|
|||
|
:L KH 1000 | ZB.: KT 50.0 -> KT 5.1
|
|||
|
:OW |
|
|||
|
:T =DWIM +-
|
|||
|
:
|
|||
|
M002 :A =FRG FREIGABE ?
|
|||
|
:JC =M003 JA -> TAKT BEARBEITEN
|
|||
|
: NEIN -> AUSGAENGE RUECKSETZEN
|
|||
|
:AN =FRG +- AUSGAENGE RUECKSETZEN
|
|||
|
:RD =T |
|
|||
|
:RB =AUSG |
|
|||
|
:RB =FERT |
|
|||
|
:L KF +1 |
|
|||
|
:DO =DBST |
|
|||
|
:T =IST |
|
|||
|
:L KF +0 |
|
|||
|
:T =BITL +-
|
|||
|
:BEC +- BAUSTEIN ENDE
|
|||
|
:
|
|||
|
M003 :DO =DBST
|
|||
|
:LW =SOLL
|
|||
|
:L KF +0
|
|||
|
:<=F SOLLWERTVORGABE ?
|
|||
|
:JC =M004 NEIN -> NAECHSTER MODE
|
|||
|
:A =FERT JA -> SOLLW.ERREICHT PRUEFEN
|
|||
|
FB 113 -FB113 CLOCK GENERAT.TIM C:ZONE10ST.S5D LIB=106 LEN=318
|
|||
|
Page 3
|
|||
|
:RB =AUSG
|
|||
|
:BEC +- BAUSTEIN ENDE
|
|||
|
:
|
|||
|
M004 :L KT 000.0 UEBERPRUEFEN OB TIMER NEU
|
|||
|
:LC =T ANLAEUFT (ZEITWERT = KT000.0)
|
|||
|
:><F
|
|||
|
:O =T TIMER LAEUFT AN ?
|
|||
|
:JC =M005 NEIN ->
|
|||
|
: JA -> STARTZUSTAENDE SETZEN
|
|||
|
:A =POS +- WENN #POS=1 AUSGANG ANSTEUERN
|
|||
|
:S =AUSG +-
|
|||
|
:AN =FRG +- FUER TIMER START EINE
|
|||
|
:FR =T | POSITIVE FLANKE ERZEUGEN
|
|||
|
:A =FRG |
|
|||
|
:FR =T +-
|
|||
|
:
|
|||
|
M005 :DO =DBT
|
|||
|
:A =AUSG
|
|||
|
:JC =M006
|
|||
|
:A =T
|
|||
|
:S =AUSG
|
|||
|
:L =DWPA
|
|||
|
:AN =AUSG
|
|||
|
:AN =RM
|
|||
|
:SD =T
|
|||
|
:BEU
|
|||
|
:
|
|||
|
M006 :AN =T
|
|||
|
:JC =M007
|
|||
|
:A =AUSG
|
|||
|
:RB =AUSG
|
|||
|
:DO =DBST
|
|||
|
:LW =SOLL
|
|||
|
:L KF +0
|
|||
|
:<=F
|
|||
|
:JC =M007
|
|||
|
:DO =DBST
|
|||
|
:L =IST
|
|||
|
:L KF +1
|
|||
|
:+F
|
|||
|
:T =IST
|
|||
|
:LW =SOLL
|
|||
|
:>F
|
|||
|
:S =FERT
|
|||
|
:
|
|||
|
:AN =FERT
|
|||
|
:JC =M008
|
|||
|
:AN =DAUE
|
|||
|
:JC =M008
|
|||
|
:L KF +1
|
|||
|
:DO =DBST
|
|||
|
:T =IST
|
|||
|
:A =FERT
|
|||
|
:RB =FERT
|
|||
|
M008 :
|
|||
|
M007 :DO =DBT TIMER-DB LADEN
|
|||
|
:L =DWIM
|
|||
|
:A =AUSG
|
|||
|
:A =RM
|
|||
|
:SD =T
|
|||
|
:
|
|||
|
:DO =DBST STATUS-DB LADEN
|
|||
|
:L KF +0
|
|||
|
:L =IST
|
|||
|
FB 113 -FB113 CLOCK GENERAT.TIM C:ZONE10ST.S5D LIB=106 LEN=318
|
|||
|
Page 4
|
|||
|
:!=F
|
|||
|
:JC =M009
|
|||
|
:AN =AUSG
|
|||
|
:L KF +0
|
|||
|
:JC =M009
|
|||
|
:L =IST +- UMWANDLUNG DES ISTWERTES
|
|||
|
:D 1 | VOM VORGABEZAEHLER UND
|
|||
|
:T FW 250 | AUSGABE
|
|||
|
:L KM 00000000 00000001 |
|
|||
|
:DO FW 250 |
|
|||
|
:SLW 0 |
|
|||
|
M009 :T =BITL +- AUSGABE AUF #BITL
|
|||
|
:BEU
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 3 INDIREKTE ADRESSIERUNG
|
|||
|
:L =T-IN
|
|||
|
:T FW 250
|
|||
|
:
|
|||
|
:L =DWIM +- ZEITBASIS UEBERPRUEFEN
|
|||
|
:SRW 12 |
|
|||
|
:L KH 0000 |
|
|||
|
:><F |
|
|||
|
:JC =M001 |
|
|||
|
:L =DWIM | AUS ZEITBASIS .0
|
|||
|
:SRW 4 | ZEITBASIS .1 HERSTELLTEN
|
|||
|
:L KH 1000 | ZB.: KT 50.0 -> KT 5.1
|
|||
|
:OW |
|
|||
|
:T =DWIM +-
|
|||
|
:
|
|||
|
M001 :A =FRG FREIGABE ?
|
|||
|
:JC =M002 JA -> TAKT BEARBEITEN
|
|||
|
: NEIN -> AUSGAENGE RUECKSETZEN
|
|||
|
:AN =FRG +- AUSGAENGE RUECKSETZEN
|
|||
|
:DO FW 250 |
|
|||
|
:R -T0 IND.ADDRES.(DUMMY) |
|
|||
|
:RB =AUSG |
|
|||
|
:RB =FERT |
|
|||
|
:L KF +1 |
|
|||
|
:T =IST |
|
|||
|
:L KF +0 |
|
|||
|
:T =BITL +-
|
|||
|
:BEC +- BAUSTEIN ENDE
|
|||
|
:
|
|||
|
M002 :LW =SOLL
|
|||
|
:L KF +0
|
|||
|
:<=F SOLLWERTVORGABE ?
|
|||
|
:JC =M003 NEIN -> NAECHSTER MODE
|
|||
|
:A =FERT JA -> SOLLW.ERREICHT PRUEFEN
|
|||
|
:RB =AUSG
|
|||
|
:BEC +- BAUSTEIN ENDE
|
|||
|
:
|
|||
|
M003 :L KT 000.0 UEBERPRUEFEN OB TIMER NEU
|
|||
|
:DO FW 250 ANLAEUFT (ZEITWERT = KT000.0)
|
|||
|
:LC -T0 IND.ADDRES.(DUMMY)
|
|||
|
:><F
|
|||
|
:DO FW 250
|
|||
|
:O -T0 IND.ADDRES.(DUMMY) TIMER LAEUFT AN ?
|
|||
|
:JC =M004 NEIN ->
|
|||
|
: JA -> STARTZUSTAENDE SETZEN
|
|||
|
:A =POS +- WENN #POS=1 AUSGANG ANSTEUERN
|
|||
|
:S =AUSG +-
|
|||
|
FB 113 -FB113 CLOCK GENERAT.TIM C:ZONE10ST.S5D LIB=106 LEN=318
|
|||
|
Page 5
|
|||
|
:AN =FRG +- FUER TIMER START EINE
|
|||
|
:DO FW 250 | POSITIVE FLANKE ERZEUGEN
|
|||
|
:FR -T0 IND.ADDRES.(DUMMY) |
|
|||
|
:A =FRG |
|
|||
|
:DO FW 250 |
|
|||
|
:FR -T0 IND.ADDRES.(DUMMY) +-
|
|||
|
:
|
|||
|
M004 :A =AUSG
|
|||
|
:JC =M005
|
|||
|
:DO FW 250
|
|||
|
:AN -T0 IND.ADDRES.(DUMMY)
|
|||
|
:JC =M006
|
|||
|
:AN =AUSG
|
|||
|
:S =AUSG
|
|||
|
:
|
|||
|
M006 :L =DWPA
|
|||
|
:AN =AUSG
|
|||
|
:AN =RM
|
|||
|
:DO FW 250
|
|||
|
:SD -T0 IND.ADDRES.(DUMMY)
|
|||
|
:BEU
|
|||
|
:
|
|||
|
M005 :DO FW 250
|
|||
|
:AN -T0 IND.ADDRES.(DUMMY)
|
|||
|
:JC =M007
|
|||
|
:A =AUSG
|
|||
|
:RB =AUSG
|
|||
|
:
|
|||
|
:LW =SOLL
|
|||
|
:L KF +0
|
|||
|
:<=F
|
|||
|
:JC =M007
|
|||
|
:L =IST
|
|||
|
:L KF +1
|
|||
|
:+F
|
|||
|
:T =IST
|
|||
|
:LW =SOLL
|
|||
|
:>F
|
|||
|
:S =FERT
|
|||
|
:
|
|||
|
:AN =FERT
|
|||
|
:JC =M008
|
|||
|
:AN =DAUE
|
|||
|
:JC =M008
|
|||
|
:L KF +1
|
|||
|
:T =IST
|
|||
|
:A =FERT
|
|||
|
:RB =FERT
|
|||
|
M008 :
|
|||
|
M007 :L =DWIM
|
|||
|
:A =AUSG
|
|||
|
:A =RM
|
|||
|
:DO FW 250
|
|||
|
:SD -T0 IND.ADDRES.(DUMMY)
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:L =IST
|
|||
|
:!=F
|
|||
|
:JC =M009
|
|||
|
:AN =AUSG
|
|||
|
:L KF +0
|
|||
|
:JC =M009
|
|||
|
:L =IST +- UMWANDLUNG DES ISTWERTES
|
|||
|
:D 1 | VOM VORGABEZAEHLER UND
|
|||
|
FB 113 -FB113 CLOCK GENERAT.TIM C:ZONE10ST.S5D LIB=106 LEN=318
|
|||
|
Page 6
|
|||
|
:T FW 250 | AUSGABE
|
|||
|
:L KM 00000000 00000001 |
|
|||
|
:DO FW 250 |
|
|||
|
:SLW 0 |
|
|||
|
M009 :T =BITL +- AUSGABE AUF #BITL
|
|||
|
:
|
|||
|
:BE
|
|||
|
|
|||
|
T 0 = T0 IND.ADDRES.(DUMMY) standard
|
|||
|
|
|||
|
FB 114 -FB114 PT-1 LINK C:ZONE10ST.S5D LEN=131
|
|||
|
Page 1
|
|||
|
Segment 1 PT1-Glied
|
|||
|
|
|||
|
FB114 PT1-GLIED STAND: 23.04.96
|
|||
|
===============================================================================
|
|||
|
***** CPU : ALLE *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : XX.XX.XX G.HERKERT
|
|||
|
(HKT)
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG : 1 XX.XX.XX H.URBAN
|
|||
|
(UR)
|
|||
|
----------------------------------------------------
|
|||
|
===============================================================================
|
|||
|
SYMBOLIKDATEI : KEINE
|
|||
|
---------------
|
|||
|
|
|||
|
BAUSTEINPARAMETER :
|
|||
|
-------------------
|
|||
|
XE : Eingangssignal
|
|||
|
XA : Ausgangssignal
|
|||
|
T : Abtastzeit
|
|||
|
K : Proportionalitaetskonstante (bestimmt Verstaerkungsverhalten)
|
|||
|
K = 1 -> XA = XE
|
|||
|
T1 : Zeitkonstante (bestimmt Anstiegsverhalten)
|
|||
|
|
|||
|
FUNKTION :
|
|||
|
----------
|
|||
|
XE--|-----------####################
|
|||
|
XA = K*XE--|-----------#-------------******
|
|||
|
| # *
|
|||
|
| # * ####### = XE
|
|||
|
| # * ******* = XA
|
|||
|
|##*#*#*#*#*#*
|
|||
|
|_________________________________
|
|||
|
|
|||
|
XA/XE = G(s) = KR / (1+s*T1) ---> XA*(1+s*T1) = XE*KR
|
|||
|
XA + XA_1 *T1 = XE * KR
|
|||
|
|
|||
|
rekursiver Algorithmus:
|
|||
|
=======================
|
|||
|
+-------<-----------------------+
|
|||
|
| |
|
|||
|
1.Ableitung: XA_1 = ( XE * KR - XA ) / T1 |
|
|||
|
XA = XA + XA_1 * T |
|
|||
|
| |
|
|||
|
+------->-----------------------+
|
|||
|
|
|||
|
|
|||
|
Name :PT1
|
|||
|
Decl :XE2 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :XE1 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :XA2 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :XA1 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :T-2 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :T-1 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :K-2 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :K-1 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :T1-2 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :T1-1 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
|
|||
|
:***
|
|||
|
|
|||
|
FB 114 -FB114 PT-1 LINK C:ZONE10ST.S5D LEN=131
|
|||
|
Page 2
|
|||
|
Segment 2 MERKER SICHERN
|
|||
|
:JU -FB165 PUSH IN STACK
|
|||
|
Name :PUSH
|
|||
|
VON : KF +200
|
|||
|
BIS : KF +254
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 165 = FB165 PUSH IN STACK from FW 200 17.11.92 hkt sp
|
|||
|
|
|||
|
Segment 3 PARAMETER UMSPEICHERN
|
|||
|
:L =XE2
|
|||
|
:T FW 230
|
|||
|
:L =XE1
|
|||
|
:T FW 232
|
|||
|
:L =XA2
|
|||
|
:T FW 234
|
|||
|
:L =XA1
|
|||
|
:T FW 236
|
|||
|
:L =T-2
|
|||
|
:T FW 238
|
|||
|
:L =T-1
|
|||
|
:T FW 240
|
|||
|
:L =K-2
|
|||
|
:T FW 242
|
|||
|
:L =K-1
|
|||
|
:T FW 244
|
|||
|
:L =T1-2
|
|||
|
:T FW 246
|
|||
|
:L =T1-1
|
|||
|
:T FW 248
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 4 XA_1 = XE * KR
|
|||
|
:JU -FB234 FLOATING P.MULTI.
|
|||
|
Name :GP:MUL
|
|||
|
Z12 : FW 230
|
|||
|
Z11 : FW 232
|
|||
|
Z22 : FW 242
|
|||
|
Z21 : FW 244
|
|||
|
OV : F 254.0
|
|||
|
Z3=0 : F 254.0
|
|||
|
Z32 : FW 250
|
|||
|
Z31 : FW 252
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 234 = FB234 FLOATING P.MULTI.
|
|||
|
|
|||
|
Segment 5 XA_1 = XA_1 - XA
|
|||
|
:JU -FB233 FLOATING P.SUBTR.
|
|||
|
Name :GP:SUB
|
|||
|
Z12 : FW 250
|
|||
|
Z11 : FW 252
|
|||
|
Z22 : FW 234
|
|||
|
Z21 : FW 236
|
|||
|
OV : F 254.0
|
|||
|
Z3=0 : F 254.0
|
|||
|
Z32 : FW 250
|
|||
|
Z31 : FW 252
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 114 -FB114 PT-1 LINK C:ZONE10ST.S5D LEN=131
|
|||
|
Page 3
|
|||
|
FB 233 = FB233 FLOATING P.SUBTR.
|
|||
|
|
|||
|
Segment 6 XA_1 = XA_1 / T1
|
|||
|
:JU -FB235 FLOATING P.DIVIS.
|
|||
|
Name :GP:DIV
|
|||
|
Z12 : FW 250
|
|||
|
Z11 : FW 252
|
|||
|
Z22 : FW 246
|
|||
|
Z21 : FW 248
|
|||
|
OV : F 254.0
|
|||
|
FEH : F 254.0
|
|||
|
Z3=0 : F 254.0
|
|||
|
Z32 : FW 250
|
|||
|
Z31 : FW 252
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 235 = FB235 FLOATING P.DIVIS.
|
|||
|
|
|||
|
Segment 7 erg = XA_1 * T
|
|||
|
:JU -FB234 FLOATING P.MULTI.
|
|||
|
Name :GP:MUL
|
|||
|
Z12 : FW 250
|
|||
|
Z11 : FW 252
|
|||
|
Z22 : FW 238
|
|||
|
Z21 : FW 240
|
|||
|
OV : F 254.0
|
|||
|
Z3=0 : F 254.1
|
|||
|
Z32 : FW 250
|
|||
|
Z31 : FW 252
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 234 = FB234 FLOATING P.MULTI.
|
|||
|
|
|||
|
Segment 8 XA = XA + XA
|
|||
|
:JU -FB232 FLOATING P.ADD.
|
|||
|
Name :GP:ADD
|
|||
|
Z12 : FW 234
|
|||
|
Z11 : FW 236
|
|||
|
Z22 : FW 250
|
|||
|
Z21 : FW 252
|
|||
|
OV : F 254.0
|
|||
|
Z3=0 : F 254.1
|
|||
|
Z32 : FW 234
|
|||
|
Z31 : FW 236
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 232 = FB232 FLOATING P.ADD.
|
|||
|
|
|||
|
Segment 9 AUSGANGSSIGNAL AUSGEBEN
|
|||
|
:L FW 234
|
|||
|
:T =XA2
|
|||
|
:L FW 236
|
|||
|
:T =XA1
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
Segment 10 GESICHERTE MERKER LADEN
|
|||
|
:JU -FB166 POP OF STACK
|
|||
|
Name :POP
|
|||
|
:BE
|
|||
|
|
|||
|
FB 114 -FB114 PT-1 LINK C:ZONE10ST.S5D LEN=131
|
|||
|
Page 4
|
|||
|
FB 166 = FB166 POP OF STACK from FW 200 17.11.92 hkt sp
|
|||
|
|
|||
|
FB 115 -FB115 LUM.PUSH-BUT.WORD C:ZONE10ST.S5D LEN=48
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
FB 115 LEUCHTTASTER (WORT)
|
|||
|
===============================================================================
|
|||
|
***** CPU : ALLE *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : 09.02.95 H.URBAN
|
|||
|
(UR)
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG : 1 XX.XX.XX XXXXXXXXXXX
|
|||
|
(XXX)
|
|||
|
----------------------------------------------------
|
|||
|
2 XX.XX.XX XXXXXXXXXXX
|
|||
|
(XXX)
|
|||
|
----------------------------------------------------
|
|||
|
===============================================================================
|
|||
|
|
|||
|
SYMBOLIKDATEI : KEINE
|
|||
|
---------------
|
|||
|
|
|||
|
BAUSTEINPARAMETER :
|
|||
|
-------------------
|
|||
|
#EING : EINGANG TASTER
|
|||
|
#AUSG : AUSGANG LAMPE
|
|||
|
#FOLG : FOLGEMERKER ZUR IMPULSAUSWERTUNG
|
|||
|
#RESE : RESET ZUM EXTERNEN RUECKSETZEN DES AUSGANGES
|
|||
|
#FILT : FILTER 0 -> AUSGANG WIRD NICHT BEEINFLUSST
|
|||
|
1 -> AUSGANG WIRD DURCH #EING & #RESE BEEINFLUSST
|
|||
|
|
|||
|
LOKALE VARIABLEN : KEINE
|
|||
|
------------------
|
|||
|
|
|||
|
FUNKTION :
|
|||
|
----------
|
|||
|
EINGANG UN AUSGANG -> AUSGANG SETZEN
|
|||
|
|
|||
|
EINGANG U AUSGANG -> AUSGANG RUECKSETZEN
|
|||
|
|
|||
|
RESET -> AUSGANG RUECKSETZEN
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Name :L-TAST W
|
|||
|
Decl :EING I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :AUSG I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :FOLG I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :RESE I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :FILT I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KM
|
|||
|
|
|||
|
:L =RESE
|
|||
|
:LW =FILT
|
|||
|
:AW
|
|||
|
:T =RESE
|
|||
|
:
|
|||
|
:L =EING
|
|||
|
:L =FOLG
|
|||
|
:XOW
|
|||
|
:L =EING
|
|||
|
:AW
|
|||
|
:LW =FILT
|
|||
|
:AW
|
|||
|
FB 115 -FB115 LUM.PUSH-BUT.WORD C:ZONE10ST.S5D LEN=48
|
|||
|
Page 2
|
|||
|
:L =AUSG
|
|||
|
:XOW
|
|||
|
:L =RESE
|
|||
|
:CFW
|
|||
|
:AW
|
|||
|
:T =AUSG
|
|||
|
:
|
|||
|
:L =EING
|
|||
|
:T =FOLG
|
|||
|
:
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 116 -FB116 CLOCK WITH n IMP. C:ZONE10ST.S5D LIB=106 LEN=94
|
|||
|
Page 1
|
|||
|
Segment 1 Takt N-Impulse
|
|||
|
|
|||
|
|
|||
|
T A K T B A U S T E I N mit bestimmter Anzahl von Impulsen
|
|||
|
============================================================
|
|||
|
|
|||
|
-------------------------------------------------
|
|||
|
erstellt: 31.11.92 HKT
|
|||
|
|
|||
|
-------------------------------------------------
|
|||
|
|
|||
|
|
|||
|
Parameter:
|
|||
|
==========
|
|||
|
|
|||
|
|
|||
|
#FRG : Freigabe
|
|||
|
#T : Timer
|
|||
|
#DWIM : Impuls - Zeitwert
|
|||
|
#DWPA : Pause - Zeitwert
|
|||
|
#AUSG : Taktausgang
|
|||
|
#POS : 1 = positiver Start / 0 = negativer Start
|
|||
|
#DB : Datenbaustein
|
|||
|
#Z-WE : Zaehlwert
|
|||
|
#ZAEH : Zaehler
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Funktion:
|
|||
|
=========
|
|||
|
|
|||
|
Beispiel: Z-WE = 3 -> 3 Impulse erwuenscht
|
|||
|
|
|||
|
--------------------------------------------
|
|||
|
1 2 3
|
|||
|
___---______---______---____
|
|||
|
Imp:Pause
|
|||
|
|
|||
|
|
|||
|
___---------------------____
|
|||
|
|
|||
|
--------------------------------------------
|
|||
|
|
|||
|
Name :TAKT
|
|||
|
Decl :FRG I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :T I/Q/D/B/T/C: T
|
|||
|
Decl :DWIM I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :DWPA I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :AUSG I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :POS I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :RM I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :DB I/Q/D/B/T/C: B
|
|||
|
Decl :Z-WE I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :ZAEH I/Q/D/B/T/C: C
|
|||
|
|
|||
|
:L =Z-WE
|
|||
|
:L =ZAEH
|
|||
|
:>F
|
|||
|
:RB =FRG
|
|||
|
:
|
|||
|
:A =FRG
|
|||
|
:JC =M001
|
|||
|
:AN =FRG
|
|||
|
:RD =T
|
|||
|
FB 116 -FB116 CLOCK WITH n IMP. C:ZONE10ST.S5D LIB=106 LEN=94
|
|||
|
Page 2
|
|||
|
:RB =AUSG
|
|||
|
:BEC
|
|||
|
:
|
|||
|
M001 :
|
|||
|
:L KT 000.0 wenn der Timer neu anlaeuft
|
|||
|
:LC =T ist der Zeitwert KT 000.0
|
|||
|
:><F
|
|||
|
:O =T
|
|||
|
:JC =M002
|
|||
|
:A =POS Start mit Impuls eingestellt
|
|||
|
:S =AUSG
|
|||
|
:AN =FRG fuer die Timerfreigabe ist
|
|||
|
:FR =T eine positive Flanke
|
|||
|
:A =FRG erforderlich
|
|||
|
:FR =T
|
|||
|
M002 :
|
|||
|
:DO =DB
|
|||
|
:A =AUSG
|
|||
|
:JC =M003 Ausgang = '0'
|
|||
|
:AN =AUSG VKE=0 -> pos.Flanke ermoeglichen
|
|||
|
:SSU =ZAEH SSV = ZV=
|
|||
|
:
|
|||
|
:A =T
|
|||
|
:S =AUSG
|
|||
|
:
|
|||
|
:L =Z-WE
|
|||
|
:AN =AUSG positive Flanke
|
|||
|
:SSU =ZAEH SSV = ZV=
|
|||
|
:
|
|||
|
:A =T
|
|||
|
:A =AUSG
|
|||
|
:SSU =ZAEH SSV = ZV=
|
|||
|
:
|
|||
|
:L =DWPA
|
|||
|
:AN =AUSG
|
|||
|
:SD =T
|
|||
|
:BEU
|
|||
|
M003 : Ausgang = '1'
|
|||
|
:A =T
|
|||
|
:RB =AUSG
|
|||
|
:L =DWIM
|
|||
|
:A =AUSG
|
|||
|
:SD =T
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 117 -FB117 CLOCK W. RECEIPT C:ZONE10ST.S5D LEN=136
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
|
|||
|
|
|||
|
********************************************************************
|
|||
|
*** TAKTGENERATOR MIT 1 TIMER UND QUITTIERUNG MIT 1-9 AUSGAENGEN ***
|
|||
|
********************************************************************
|
|||
|
|
|||
|
|
|||
|
|
|||
|
PARAMETER: FRG : FREIGABE TAKTBETRIEB
|
|||
|
---------
|
|||
|
TMR : TIMER FUER IMPULS- UND PAUSENZEIT
|
|||
|
|
|||
|
DWPA : ZEITWERT FUER PAUSE (DW,MW)
|
|||
|
|
|||
|
DWIM : ZEITWERT FUER IMPULS (DW,MW)
|
|||
|
|
|||
|
RUEM : RUECKMELDUNG VOM BETRIEBSMITTEL
|
|||
|
Z.B. MOTORSCHUETZ, STATISCHER MERKER 1
|
|||
|
|
|||
|
AUS1 : ANSTEUERUNG DES BETRIEBSMITTELS
|
|||
|
AUS2 Z.B. VIBRATIONSMOTOR, FILTER, BLINKLAMPE
|
|||
|
USW.
|
|||
|
|
|||
|
MAX : MAXIMALE ANZAHL DER BENUTZTEN AUSGAENGE
|
|||
|
|
|||
|
AKT : NUMMER DES AKTUELLEN AUSGANGES
|
|||
|
MB ODER DL,DR
|
|||
|
|
|||
|
|
|||
|
|
|||
|
FUNKTIONSBESCHREIBUNG
|
|||
|
---------------------
|
|||
|
|
|||
|
|
|||
|
DIESER FUNKTIONSBAUSTEIN BENOETIGT LEDIGLICH EINEN TIMER UND DIE RUECKMELDUNG
|
|||
|
VOM BETRIEBSMITTELS. DIE RUECKMELDUNG IST DESHALB ERFORDERLICH UM EIN WEITER-
|
|||
|
LAUFEN DES TAKTAUSGANGES BEI AUSFALL DES BETRIEBSMITTELS ZU UNTERBINDEN UND
|
|||
|
DAMIT EINE FEHLERANALYSE DURCHFUEHREN ZU KOENNEN. SOMIT STEHEN DIE AUSGAENGE
|
|||
|
DES FB SOLANGE AN BIS DIE RUECKMELDUNG KOMMT, D.H. DIE IMPULSZEIT KANN NICHT
|
|||
|
ABLAUFEN. NATUERLICH KANN DER FB ALS EIN GEWOEHNLICHER TAKTGENERATOR VERWENDET
|
|||
|
WERDEN, INDEM ALS RUECKMELDUNG Z.B. EIN MERKER MIT STATUS 1 VERWENDET WIRD.
|
|||
|
|
|||
|
Name :TAKT QUI TAKT MIT QUITTIERUNG
|
|||
|
Decl :FRG I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :TMR I/Q/D/B/T/C: T
|
|||
|
Decl :DWPA I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :DWIM I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :RUEM I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :AUS1 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :AUS2 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :AUS3 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :AUS4 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :AUS5 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :AUS6 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :AUS7 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :AUS8 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :AUS9 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :MAX I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :AKT I/Q/D/B/T/C: Q BI/BY/W/D: BY
|
|||
|
Decl :HM I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
|
|||
|
:***
|
|||
|
FB 117 -FB117 CLOCK W. RECEIPT C:ZONE10ST.S5D LEN=136
|
|||
|
Page 2
|
|||
|
Segment 2 TAKTERZEUGUNG FUER MOTOREN
|
|||
|
:AN =FRG WENN KEINE FREIGABE DANN SPRUNG
|
|||
|
:JC =M001 ZUR RUECKSETZUNG AUSGANG UND TMR
|
|||
|
:AN =HM WENN HILFSMERKER GESETZT, DANN
|
|||
|
:JC =M002 SPRUNG ZU IMPULSZEITBEARBEITUNG
|
|||
|
:A =RUEM ANDERNFALLS RUECKMELDUNG
|
|||
|
:L =DWIM ABFRAGEN UND PAUSENZEIT STARTEN
|
|||
|
:SD =TMR
|
|||
|
:AN =TMR SOLANGE PAUSENZEIT NICHT UM
|
|||
|
:BEC FB VERLASSEN
|
|||
|
:AN =HM NACH ABLAUF AUSGANG SETZEN UND
|
|||
|
:= =HM SPRUNG ZUM VKE-START-TIMER
|
|||
|
:JU =M003 BEARBEITEN
|
|||
|
M002 :L =DWPA IMPULSZEIT STARTEN, WENN AUS-
|
|||
|
:SD =TMR GANG GESETZT.
|
|||
|
:AN =TMR
|
|||
|
:BEC NACH ABLAUF IMPULSZEIT AUSGANG
|
|||
|
:L =AKT UEBERPRUEFEN, OB MAX. ANZAHL
|
|||
|
:LW =MAX DER AUSGAENGE ERREICHT.WENN NEIN
|
|||
|
:<F SPRUNG ZUM NAECHSTEN AUSGANG
|
|||
|
:JC =M004
|
|||
|
:L KB 0 ANDERNFALL WIEDER VON NEUEM BE-
|
|||
|
:T =AKT GINNEN
|
|||
|
M004 :L =AKT NAECHSTER AUSGANG !!!
|
|||
|
:I 1
|
|||
|
:T =AKT
|
|||
|
:AN =HM HILFSMERKER AUF 1 SETZEN
|
|||
|
:= =HM
|
|||
|
M003 :AN =FRG TIMER INITIALISIEREN
|
|||
|
:L KT 000.0
|
|||
|
:SD =TMR
|
|||
|
M015 :L =AKT
|
|||
|
:T FW 220 ZAEHLERSTAND 0 AUSSCHLIESSEN
|
|||
|
:L KB 0
|
|||
|
:!=F
|
|||
|
:BEC
|
|||
|
:A =HM HILFSMERKER DEN AUSGAENGEN
|
|||
|
:DO FW 220 ZUWEISEN
|
|||
|
M005 :JU =M005
|
|||
|
:JU =M006 AUSGANG 1
|
|||
|
:JU =M007 AUSGANG 2
|
|||
|
:JU =M008 AUSGANG 3
|
|||
|
:JU =M009 USW.
|
|||
|
:JU =M010
|
|||
|
:JU =M011
|
|||
|
:JU =M012
|
|||
|
:JU =M013
|
|||
|
:JU =M014
|
|||
|
M006 := =AUS1
|
|||
|
:BEU
|
|||
|
M007 := =AUS2
|
|||
|
:BEU
|
|||
|
M008 := =AUS3
|
|||
|
:BEU
|
|||
|
M009 := =AUS4
|
|||
|
:BEU
|
|||
|
M010 := =AUS5
|
|||
|
:BEU
|
|||
|
M011 := =AUS6
|
|||
|
:BEU
|
|||
|
M012 := =AUS7
|
|||
|
:BEU
|
|||
|
M013 := =AUS8
|
|||
|
:BEU
|
|||
|
FB 117 -FB117 CLOCK W. RECEIPT C:ZONE10ST.S5D LEN=136
|
|||
|
Page 3
|
|||
|
M014 := =AUS9
|
|||
|
:BEU
|
|||
|
M001 :A =FRG TIMER NACH FREIGABERUECKNAHME
|
|||
|
:L KT 000.0 INITIALISIEREN
|
|||
|
:SD =TMR
|
|||
|
:A =FRG HILFSMERKER AUF NULL SETZEN
|
|||
|
:= =HM UND NOCHMALS DEN AUSGAENGEN
|
|||
|
:JU =M015 ZUWEISEN.
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 118 -FB118 PRESSURE TRANSMIT C:ZONE10ST.S5D LEN=172
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
FB 118 DRUCKAUFNEHMER STAND : 15.05.97
|
|||
|
===============================================================================
|
|||
|
***** CPU : 135U, 945, 948 *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : XX.XX.XX XXXXXXX
|
|||
|
XXXX
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG :
|
|||
|
|
|||
|
NR. DATUM AENDERUNG BEARBEITER
|
|||
|
-------------------------------------------------------------------------------
|
|||
|
01 15.05.97 PARAMETER S5S7 EINGEFUEGT UR
|
|||
|
PARAMETER TIMP EINGEFUEGT
|
|||
|
===============================================================================
|
|||
|
SYMBOLIK : KEINE
|
|||
|
================
|
|||
|
|
|||
|
|
|||
|
PARAMETER :
|
|||
|
===========
|
|||
|
#BGRN : BAUGRUPPE, KANAL
|
|||
|
#OG : OBERGRENZE (KF=+/-.....)
|
|||
|
#UG : UNTERGRENZE (KF=+/-......)
|
|||
|
#AUSG : AUSGABE DES EINGELESENEN UND UMGERECHNETEN WERTES
|
|||
|
#FEHL : FEHLER Z.B. BEI DRAHTBRUCH
|
|||
|
#AKTV : GEBLAESE AKTIV
|
|||
|
#TIMP : TIMER IMPULS FUER ABGLEICH AUF NULL
|
|||
|
S5S7 : S5 -> S5 FORMAT 512-2516 DIGIT
|
|||
|
S7 -> S7 FORMAT 0-27648 DIGIT
|
|||
|
|
|||
|
|
|||
|
BERECHNUNG:
|
|||
|
|
|||
|
S5-FORMAT -> AUSG = UG + ((OG - UG) * (BGRN - 512)) / 2048
|
|||
|
S7-FORMAT -> AUSG = UG + ((OG - UG) * BGRN ) / 27648
|
|||
|
|
|||
|
|
|||
|
BEMERKUNG: DIESER BAUSTEIN WANDELT ANALOGSIGNALE IN KF-FORMAT UM.
|
|||
|
IST DER AKTIV MERKER NICHT GESETZT WIRD DER AUSGANG AUTOMATISCH
|
|||
|
AUF NULL ABGEGLICHEN.
|
|||
|
|
|||
|
WICHTIG : DIE DATEN WORTE FUER OBER UND UNTERGRENZE MUESSEN BEI EINEM
|
|||
|
DATENVERLUST MIT WERTEN VORBELEGT WERDEN :
|
|||
|
|
|||
|
|
|||
|
DRUCKTRANSMITTER 0-1,5 OG +50 UG -100
|
|||
|
0-2.0 OG +100 UG -100
|
|||
|
0-4,0 OG +300 UG -100
|
|||
|
|
|||
|
Name :DRUCKAUF
|
|||
|
Decl :BGRN I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :OG I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :UG I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :AUSG I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :FEHL I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :AKTV I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :TIMP I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :S5S7 I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KS
|
|||
|
|
|||
|
:***
|
|||
|
FB 118 -FB118 PRESSURE TRANSMIT C:ZONE10ST.S5D LEN=172
|
|||
|
Page 2
|
|||
|
Segment 2
|
|||
|
:LW =S5S7
|
|||
|
:L KS S5
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =BGRN
|
|||
|
:T FW 220
|
|||
|
:
|
|||
|
:L FY 220
|
|||
|
:L KH 0000
|
|||
|
:><F
|
|||
|
:JC =M002
|
|||
|
:DO FW 220
|
|||
|
:L PW 0
|
|||
|
:JU =M003
|
|||
|
M002 :L KH 0000
|
|||
|
:T FY 220
|
|||
|
:DO FW 220
|
|||
|
:L OW 0
|
|||
|
M003 :
|
|||
|
:T FW 222
|
|||
|
:SRW 3
|
|||
|
:L KF +512
|
|||
|
:-F
|
|||
|
:T FW 220
|
|||
|
:
|
|||
|
:L =OG
|
|||
|
:L =UG
|
|||
|
:-F
|
|||
|
:FDG
|
|||
|
:L FW 220
|
|||
|
:FDG
|
|||
|
:XG
|
|||
|
:L KG +4882812-03
|
|||
|
:XG
|
|||
|
:GFD
|
|||
|
:L =UG
|
|||
|
:+F
|
|||
|
:
|
|||
|
:
|
|||
|
:T =AUSG
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 3
|
|||
|
:LW =S5S7
|
|||
|
:L KS S7
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =BGRN
|
|||
|
:T FW 220
|
|||
|
:
|
|||
|
:L FY 220
|
|||
|
:L KH 0000
|
|||
|
:><F
|
|||
|
:JC =M002
|
|||
|
:DO FW 220
|
|||
|
:L PW 0
|
|||
|
:JU =M003
|
|||
|
M002 :L KH 0000
|
|||
|
:T FY 220
|
|||
|
FB 118 -FB118 PRESSURE TRANSMIT C:ZONE10ST.S5D LEN=172
|
|||
|
Page 3
|
|||
|
:DO FW 220
|
|||
|
:L OW 0
|
|||
|
M003 :
|
|||
|
:T FW 220
|
|||
|
:
|
|||
|
:L =OG
|
|||
|
:L =UG
|
|||
|
:-F
|
|||
|
:FDG
|
|||
|
:L FW 220
|
|||
|
:FDG
|
|||
|
:XG
|
|||
|
:L KG +3616898-04
|
|||
|
:XG
|
|||
|
:GFD
|
|||
|
:L =UG
|
|||
|
:+F
|
|||
|
:
|
|||
|
:
|
|||
|
:T =AUSG
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 4
|
|||
|
:LW =S5S7
|
|||
|
:L KS S5
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:O F 222.7
|
|||
|
:O(
|
|||
|
:L FW 222 01
|
|||
|
:L KM 00000000 00000000 01
|
|||
|
:!=F 01
|
|||
|
:) 01
|
|||
|
:= =FEHL
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 5
|
|||
|
:O =AKTV
|
|||
|
:O =FEHL
|
|||
|
:ON =TIMP
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L =AUSG
|
|||
|
:L KF +0
|
|||
|
:!=F
|
|||
|
:JC =M001
|
|||
|
:>F
|
|||
|
:JC =M002
|
|||
|
:L =OG
|
|||
|
:I 1
|
|||
|
:T =OG
|
|||
|
:L =UG
|
|||
|
:I 1
|
|||
|
:T =UG
|
|||
|
:JU =M001
|
|||
|
:
|
|||
|
M002 :L =OG
|
|||
|
:D 1
|
|||
|
:T =OG
|
|||
|
FB 118 -FB118 PRESSURE TRANSMIT C:ZONE10ST.S5D LEN=172
|
|||
|
Page 4
|
|||
|
:L =UG
|
|||
|
:D 1
|
|||
|
:T =UG
|
|||
|
:
|
|||
|
M001 :BE
|
|||
|
|
|||
|
|
|||
|
FB 129 -FB129 3964(R) SUETRON C:ZONE10ST.S5D LIB=2102 LEN=147
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
FB 129 - BS1640 KOPPLUNG 3964R STAND: 23.01.96
|
|||
|
===============================================================================
|
|||
|
***** CPU : 948 *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : XX.XX.XX XXXXXXXXXXX
|
|||
|
(XXX)
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG : 1 10.04.95 H.URBAN
|
|||
|
AN CPU 948 ANGEPASST (UR)
|
|||
|
----------------------------------------------------
|
|||
|
2 23.01.96 HKT
|
|||
|
Parameter VIPA eingefuehrt (NW2)
|
|||
|
----------------------------------------------------
|
|||
|
===============================================================================
|
|||
|
SYMBOLIKDATEI : KEINE
|
|||
|
---------------
|
|||
|
|
|||
|
BAUSTEINPARAMETER :
|
|||
|
-------------------
|
|||
|
#WRDB : NUMMER DES KOPPEL-DB'S MIT TERMINAL
|
|||
|
#REQM : KOPPELMERKER
|
|||
|
#VIPA : "JA", WENN VIPA-KARTE EINGESETZT WIRD
|
|||
|
"NE", WENN CP524,CP525 EINGESETZT WIRD
|
|||
|
|
|||
|
|
|||
|
LOKALE VARIABLEN :
|
|||
|
------------------
|
|||
|
SCHMIERMERKER >= MW 248
|
|||
|
|
|||
|
FUNKTION :
|
|||
|
----------
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Name :BS1640KO
|
|||
|
Decl :WRDB I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :REQM I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :VIPA I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KS
|
|||
|
|
|||
|
:AN =REQM KOORD.MERKER NICHT GESETZT
|
|||
|
:BEC
|
|||
|
:AN =REQM KOORD.MERKER RUCKSETZEN
|
|||
|
:= =REQM
|
|||
|
:LW =WRDB KOMM.DB ANWAHLEN
|
|||
|
:T FW 254
|
|||
|
:DO FW 254
|
|||
|
:C -DB 0 IND.ADRESS.(DUMNY)
|
|||
|
:LW =WRDB ANFANGSADR. DES WRDB BESTIMMEN
|
|||
|
:SLW 1
|
|||
|
:L DH 000E EC00
|
|||
|
:+D
|
|||
|
:MAB
|
|||
|
:LRW +0
|
|||
|
:RLD 4
|
|||
|
:L KB 3
|
|||
|
:+D
|
|||
|
:T FD 248
|
|||
|
: --- MERKERBYTES SCHREIBEN ------
|
|||
|
:L DL 0
|
|||
|
:L KB 3 MERKERBYTES SCHREIBEN?
|
|||
|
FB 129 -FB129 3964(R) SUETRON C:ZONE10ST.S5D LIB=2102 LEN=147
|
|||
|
Page 2
|
|||
|
:><F
|
|||
|
:JC =M001 WENN ANDERER DATENTYP
|
|||
|
:L DH 000E FC00
|
|||
|
:L DW 1
|
|||
|
:+D
|
|||
|
:L KF -1
|
|||
|
:+D
|
|||
|
:T FD 252
|
|||
|
:JU =M002
|
|||
|
M001 :
|
|||
|
: --- AUSGANGSBYTES SCHREIBEN ----
|
|||
|
:L DL 0
|
|||
|
:L KB 2 AUSGANGSBYTES SCHREIBEN?
|
|||
|
:><F
|
|||
|
:JC =M003 WENN ANDERER DATENTYP
|
|||
|
:L KH EF80
|
|||
|
:L DW 1
|
|||
|
:+D
|
|||
|
:L KF -1
|
|||
|
:+D
|
|||
|
:T FD 252
|
|||
|
:JU =M002
|
|||
|
M003 :JU =M004
|
|||
|
M002 :
|
|||
|
M006 :L DR 0 1 BYTE KOPIEREN
|
|||
|
:L KB 0
|
|||
|
:!=F LANGE = 0
|
|||
|
:JC =M005
|
|||
|
:
|
|||
|
:L FW 252 ZIELADR. INKREMENTIEREN
|
|||
|
:L KB 1
|
|||
|
:+F
|
|||
|
:T FW 252
|
|||
|
:L FW 254 QUELLADR. INKREMENTIEREN
|
|||
|
:L KB 1
|
|||
|
:+F
|
|||
|
:T FW 254
|
|||
|
:L FW 252
|
|||
|
:TNB 1
|
|||
|
:L DR 0
|
|||
|
:L KF -1
|
|||
|
:+F
|
|||
|
:T DR 0
|
|||
|
:JU =M006
|
|||
|
M005 :JU =M007
|
|||
|
M004 :
|
|||
|
: --- MERKERBIT SCHREIBEN --------
|
|||
|
:L DL 0
|
|||
|
:L KB 12 MERKERBIT SCHREIBEN?
|
|||
|
:><F
|
|||
|
:JC =M008 WENN ANDERER DATENTYP
|
|||
|
:L DL 2 QUELLE LADEN
|
|||
|
:L KB 1
|
|||
|
:!=F
|
|||
|
:DO DW 1 AUF ZIEL SCHREIBEN
|
|||
|
:= -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
:JU =M007
|
|||
|
M008 :
|
|||
|
: --- AUSGANGSBIT SCHREIBEN ------
|
|||
|
:L DL 0
|
|||
|
:L KB 11 AUSGANGSBIT SCHREIBEN?
|
|||
|
:><F
|
|||
|
:JC =M009 WENN ANDERER DATENTYP
|
|||
|
:L DL 2 QUELLE LADEN
|
|||
|
FB 129 -FB129 3964(R) SUETRON C:ZONE10ST.S5D LIB=2102 LEN=147
|
|||
|
Page 3
|
|||
|
:L KB 1
|
|||
|
:!=F
|
|||
|
:DO DW 1 AUF ZIEL SCHREIBEN
|
|||
|
:= Q 0.0
|
|||
|
:JU =M007
|
|||
|
M009 :
|
|||
|
M007 :
|
|||
|
:***
|
|||
|
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
|
|||
|
DB 0 = DB 0 IND.ADRESS.(DUMNY)
|
|||
|
|
|||
|
Segment 2 KOPPELMERKER RUECKSETZEN
|
|||
|
|
|||
|
23.01.96 HKT - (1) NETZWERK WIRD NUR BEI CP'S BEARBEITET
|
|||
|
|
|||
|
:LW =VIPA BEI VIPA-KARTE NICHT ERF. (1)
|
|||
|
:L KS JA (1)
|
|||
|
:!=F (1)
|
|||
|
:BEC (1)
|
|||
|
:
|
|||
|
:LW =REQM
|
|||
|
:L KH 00FF
|
|||
|
:AW
|
|||
|
:T FW 254
|
|||
|
:
|
|||
|
:L DH 000F F200
|
|||
|
:L FW 254
|
|||
|
:+D
|
|||
|
:T FD 250
|
|||
|
:
|
|||
|
:DO FW 254
|
|||
|
:L FW 0
|
|||
|
:L FD 250
|
|||
|
:
|
|||
|
:TIR 3
|
|||
|
:
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 135 -FB135 TEST DATABIT C:ZONE10ST.S5D LEN=110
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
FB 135 DATENBIT ABFRAGE STAND : 21.12.92
|
|||
|
===============================================================================
|
|||
|
***** CPU : 948 *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : 21.12.94 G.HERKERT
|
|||
|
(HKT)
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG :
|
|||
|
|
|||
|
NR. DATUM AENDERUNG BEARBEITER
|
|||
|
-------------------------------------------------------------------------------
|
|||
|
01 XX.XX.XX XXX
|
|||
|
===============================================================================
|
|||
|
|
|||
|
|
|||
|
PARAMETER:
|
|||
|
==========
|
|||
|
|
|||
|
#DB : DATENBAUSTEIN
|
|||
|
#DW : DATENWORT
|
|||
|
#BIT : BIT_NUMMER
|
|||
|
#WERT : ZU TRANSFERIERNDER WERT
|
|||
|
#DBDX : BAUSTEIN_ART DB ODER DX
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Name :D-BIT AB
|
|||
|
Decl :DB I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :DW I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :BIT I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :WERT I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :DBDX I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KS
|
|||
|
|
|||
|
:JU -FB165 PUSH IN STACK
|
|||
|
Name :PUSH
|
|||
|
VON : KF +240
|
|||
|
BIS : KF +254
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 165 = FB165 PUSH IN STACK from FW 200 17.11.92 hkt sp
|
|||
|
|
|||
|
Segment 2
|
|||
|
:L =DW
|
|||
|
:L KF +0
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:LW =DBDX
|
|||
|
:L KS DB
|
|||
|
:!=F
|
|||
|
:JC =M002
|
|||
|
:TAK
|
|||
|
:L KS DX
|
|||
|
:!=F
|
|||
|
:JC =M003
|
|||
|
:JU =M001
|
|||
|
M002 :L =DB
|
|||
|
:JU -FB171 TEST DB
|
|||
|
Name :DB-TEST
|
|||
|
ADR : FW 240
|
|||
|
FB 135 -FB135 TEST DATABIT C:ZONE10ST.S5D LEN=110
|
|||
|
Page 2
|
|||
|
LAEN : FW 242
|
|||
|
DBDX : KS DB
|
|||
|
:JC =M001
|
|||
|
:JU =M004
|
|||
|
M003 :L =DB
|
|||
|
:JU -FB171 TEST DB
|
|||
|
Name :DB-TEST
|
|||
|
ADR : FW 240
|
|||
|
LAEN : FW 242
|
|||
|
DBDX : KS DX
|
|||
|
:JC =M001
|
|||
|
M004 :L FW 242
|
|||
|
:L =DW
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:L =DW
|
|||
|
:L =BIT
|
|||
|
:D 1
|
|||
|
:SRW 4
|
|||
|
:+F
|
|||
|
:T FW 244
|
|||
|
:L FW 242
|
|||
|
:>F
|
|||
|
:JC =M001
|
|||
|
:L FW 240
|
|||
|
:RLD 4
|
|||
|
:T FD 240
|
|||
|
:L FW 244
|
|||
|
:
|
|||
|
:+D
|
|||
|
:T FD 240
|
|||
|
:L FD 240
|
|||
|
:LIR 1
|
|||
|
:T FW 244
|
|||
|
:
|
|||
|
:L KM 00000000 00001111
|
|||
|
:L =BIT
|
|||
|
:D 1
|
|||
|
:AW
|
|||
|
:T FW 242
|
|||
|
:
|
|||
|
:L FW 244
|
|||
|
:DO FW 242
|
|||
|
:SRW 0
|
|||
|
:L KM 00000000 00000001
|
|||
|
:AW
|
|||
|
:JZ =M005
|
|||
|
:AN =WERT
|
|||
|
:S =WERT
|
|||
|
:JU =M001
|
|||
|
M005 :
|
|||
|
:A =WERT
|
|||
|
:RB =WERT
|
|||
|
M001 :
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 171 = FB171 TEST DB sp
|
|||
|
|
|||
|
Segment 3
|
|||
|
:JU -FB166 POP OF STACK
|
|||
|
Name :POP
|
|||
|
:BE
|
|||
|
|
|||
|
FB 135 -FB135 TEST DATABIT C:ZONE10ST.S5D LEN=110
|
|||
|
Page 3
|
|||
|
FB 166 = FB166 POP OF STACK from FW 200 17.11.92 hkt sp
|
|||
|
|
|||
|
FB 136 -FB136 ASSIGN DATABIT C:ZONE10ST.S5D LEN=147
|
|||
|
Page 1
|
|||
|
Segment 1 DATENBIT ZUWEISEN
|
|||
|
|
|||
|
FB 136 DATENBIT SETEN STAND : 22.07.96
|
|||
|
===============================================================================
|
|||
|
***** CPU : 948 *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : 21.12.92 G.HERKERT
|
|||
|
(HKT)
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG :
|
|||
|
|
|||
|
NR. DATUM AENDERUNG BEARBEITER
|
|||
|
-------------------------------------------------------------------------------
|
|||
|
01 24.07.96 N1 (1); WENN BIT=0 BAUSTEIN NICHT BEARBEITEN UR
|
|||
|
02
|
|||
|
===============================================================================
|
|||
|
SYMBOLIKDATEI : KEINE
|
|||
|
----------------------
|
|||
|
|
|||
|
BAUSTEINPARAMETER :
|
|||
|
--------------------
|
|||
|
|
|||
|
#DB : DATENBAUSTEIN
|
|||
|
#DW : DATENWORT, AB DEM DIE BITLEISTE BEGINNT
|
|||
|
#BIT : NUMMER DES BITS IN DER BITLEISTE
|
|||
|
#WERT : ZU TRANSFERIERNDER WERT (0 ODER 1)
|
|||
|
#DBDX : BAUSTEINART DB ODER DX
|
|||
|
|
|||
|
FUNKTION :
|
|||
|
-----------
|
|||
|
ES WIRD DAS BIT GESETZT ODER RUECKGESETZT, DAS DURCH DIE PARAMETER
|
|||
|
FESTGELEGT WURDE.
|
|||
|
|
|||
|
|
|||
|
BEISPIEL :
|
|||
|
-----------
|
|||
|
BITLEISTE AB DW 7
|
|||
|
|
|||
|
ZUORDNUNGSTABELLE
|
|||
|
|
|||
|
BIT IN KF DATENBIT
|
|||
|
--------------------------
|
|||
|
0 => KEINE AUSWIRKUNG
|
|||
|
1 => D 7.0
|
|||
|
2 => D 7.1
|
|||
|
:
|
|||
|
17 => D 8.0
|
|||
|
18 => D 8.1
|
|||
|
:
|
|||
|
33 => D 9.0
|
|||
|
34 => D 9.1
|
|||
|
|
|||
|
etc.
|
|||
|
|
|||
|
|
|||
|
Name :DBIT-ZUW
|
|||
|
Decl :DB I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :DW I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :BIT I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :WERT I/Q/D/B/T/C: I BI/BY/W/D: BI
|
|||
|
Decl :DBDX I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KS
|
|||
|
|
|||
|
FB 136 -FB136 ASSIGN DATABIT C:ZONE10ST.S5D LEN=147
|
|||
|
Page 2
|
|||
|
:
|
|||
|
:L =BIT +- WENN BIT = 0 WIRD (1)
|
|||
|
:L KF +0 | BAUSTEIN NICHT BEARBEITET (1)
|
|||
|
:!=F | (1)
|
|||
|
:BEC +- (1)
|
|||
|
:
|
|||
|
: !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
|
|||
|
: ! NACH ENDE DER TESTPHASE AN !
|
|||
|
: ! MARKIERTEN STELLEN BEA EIN- !
|
|||
|
: ! FUEGEN !
|
|||
|
: !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
|
|||
|
:L =DB
|
|||
|
:L KF +1
|
|||
|
:<=F
|
|||
|
:JC =M001
|
|||
|
:L =DB
|
|||
|
:L KF +255
|
|||
|
:>F
|
|||
|
:JC =M001
|
|||
|
:L =DW
|
|||
|
:L KF +0
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:JU =M002
|
|||
|
:
|
|||
|
M001 : BEA einfuegen
|
|||
|
:L =DB
|
|||
|
:T FW 200
|
|||
|
:L =DW
|
|||
|
:T FW 202
|
|||
|
:STS
|
|||
|
:
|
|||
|
M002 :
|
|||
|
:JU -FB165 PUSH IN STACK
|
|||
|
Name :PUSH
|
|||
|
VON : KF +240
|
|||
|
BIS : KF +254
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 165 = FB165 PUSH IN STACK from FW 200 17.11.92 hkt sp
|
|||
|
|
|||
|
Segment 2
|
|||
|
:L =DW
|
|||
|
:L KF +0
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:LW =DBDX BAUSTEIN = DB
|
|||
|
:L KS DB
|
|||
|
:!=F
|
|||
|
:JC =M002
|
|||
|
:TAK BAUSTEIN = DX
|
|||
|
:L KS DX
|
|||
|
:!=F
|
|||
|
:JC =M003
|
|||
|
:JU =M001 FALSCHER PARAMETER DBDX
|
|||
|
M002 :L =DB
|
|||
|
:JU -FB171 TEST DB
|
|||
|
Name :DB-TEST
|
|||
|
ADR : FW 240
|
|||
|
LAEN : FW 242
|
|||
|
DBDX : KS DB
|
|||
|
:JC =M001 DB NICHT VORHANDEN
|
|||
|
:JU =M004
|
|||
|
FB 136 -FB136 ASSIGN DATABIT C:ZONE10ST.S5D LEN=147
|
|||
|
Page 3
|
|||
|
M003 :L =DB
|
|||
|
:JU -FB171 TEST DB
|
|||
|
Name :DB-TEST
|
|||
|
ADR : FW 240
|
|||
|
LAEN : FW 242
|
|||
|
DBDX : KS DX
|
|||
|
:JC =M001
|
|||
|
M004 :L FW 242 DB - LAENGE TESTEN
|
|||
|
:L =DW
|
|||
|
:<F
|
|||
|
:JC =M001
|
|||
|
:L =DW
|
|||
|
:L =BIT
|
|||
|
:D 1
|
|||
|
:SRW 4
|
|||
|
:+F
|
|||
|
:T FW 244 DW - WORTADRESSE
|
|||
|
:L FW 242 > LAENGE
|
|||
|
:>F
|
|||
|
:JC =M001
|
|||
|
:L FW 240 MW240:aus FB171
|
|||
|
:RLD 4
|
|||
|
:T FD 240 ADRESSE DB DW 0
|
|||
|
:L FW 244 DATENWORTADRESSE
|
|||
|
: * slw1
|
|||
|
:+D
|
|||
|
:T FD 240
|
|||
|
:LIR 1
|
|||
|
:T FW 244 INHALT DATENWORT
|
|||
|
:
|
|||
|
:L KM 00000000 00001111
|
|||
|
:L =BIT
|
|||
|
:D 1
|
|||
|
:AW
|
|||
|
:T FW 246
|
|||
|
:
|
|||
|
:L KM 00000000 00000001
|
|||
|
:DO FW 246 MW 242 = BITADRESSE
|
|||
|
:SLW 0
|
|||
|
:A =WERT
|
|||
|
:JC =M005
|
|||
|
:CFW
|
|||
|
:L FW 244
|
|||
|
:AW
|
|||
|
:JU =M006
|
|||
|
M005 :L FW 244 ALTER DTAENWORTINHALT
|
|||
|
:OW
|
|||
|
M006 :
|
|||
|
:L FD 240 ADRESSE DB + OFFSET DATENWORT
|
|||
|
:TIR 3
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
FB 171 = FB171 TEST DB sp
|
|||
|
|
|||
|
Segment 3
|
|||
|
:JU -FB166 POP OF STACK
|
|||
|
Name :POP
|
|||
|
:BE
|
|||
|
|
|||
|
FB 166 = FB166 POP OF STACK from FW 200 17.11.92 hkt sp
|
|||
|
|
|||
|
FB 138 -FB138 RESERVE DWs C:ZONE10ST.S5D LEN=111
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
FB 138 - VORBELEGEN VON DW'S EINES DATENBAUSTEINS STAND:12.03.97
|
|||
|
===============================================================================
|
|||
|
***** CPU : ALLE *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : 22.11.95 H.URBAN
|
|||
|
(UR)
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG :
|
|||
|
|
|||
|
NR. DATUM AENDERUNG BEARBEITER
|
|||
|
-------------------------------------------------------------------------------
|
|||
|
01 12.03.97 N3 (1) UR
|
|||
|
===============================================================================
|
|||
|
SYMBOLIKDATEI : KEINE
|
|||
|
---------------
|
|||
|
|
|||
|
BAUSTEINPARAMETER :
|
|||
|
-------------------
|
|||
|
#DBNR : DATENBAUSTEIN NUMMER
|
|||
|
#VON : ANFANG IM DATENBAUSTEIN
|
|||
|
#BIS : ENDE IM DATENBAUSTEIN
|
|||
|
#LAEN : ANZAHL DATENWORTE
|
|||
|
#L-B : LA -> PARAMETER #VON UND #LAEN WERDEN AUSGEWERTET
|
|||
|
BI -> PARAMETER #VON UND #BIS WERDEN AUSGEWERTET
|
|||
|
#WERT : WERT MIT DEM DIE DATENWORTE VORBELEGT WERDEN SOLLEN
|
|||
|
#DBDX : BAUSTEINTYP 'DB' ODER 'DX'
|
|||
|
|
|||
|
LOKALE VARIABLEN :
|
|||
|
------------------
|
|||
|
MW 220 - MW228
|
|||
|
MERKER WERDEN GESICHERT, DUERFEN ARBER NICHT ALS PARAMETER VERWENDET WERDEN.
|
|||
|
|
|||
|
FUNKTION :
|
|||
|
----------
|
|||
|
BAUSTEIN BESCHREIBT DIE ANGEGEBENEN DATENWORTE MIT DEM IM PARAMETER WERT
|
|||
|
EINGETRAGENEN WERT.
|
|||
|
|
|||
|
|
|||
|
Name :DB-VORBE
|
|||
|
Decl :DBNR I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :VON I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :BIS I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :LAEN I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :L-B I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KS
|
|||
|
Decl :WERT I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KH
|
|||
|
Decl :DBDX I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KS
|
|||
|
|
|||
|
:
|
|||
|
:JU -FB165 PUSH IN STACK +- MERKER SICHERN
|
|||
|
Name :PUSH
|
|||
|
VON : KF +220 |
|
|||
|
BIS : KF +230 +-
|
|||
|
:
|
|||
|
:L =DBNR
|
|||
|
:T FW 220
|
|||
|
:L =VON
|
|||
|
:T FW 222
|
|||
|
:L =BIS
|
|||
|
:T FW 224
|
|||
|
:L =LAEN
|
|||
|
FB 138 -FB138 RESERVE DWs C:ZONE10ST.S5D LEN=111
|
|||
|
Page 2
|
|||
|
:T FW 226
|
|||
|
:LW =WERT
|
|||
|
:T FW 228
|
|||
|
:
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
FB 165 = FB165 PUSH IN STACK from FW 200 17.11.92 hkt sp
|
|||
|
|
|||
|
Segment 2 L-B AUSWERTEN
|
|||
|
:LW =L-B
|
|||
|
:L KS BI
|
|||
|
:!=F
|
|||
|
:JC =M001
|
|||
|
:LW =L-B
|
|||
|
:L KS LA
|
|||
|
:!=F
|
|||
|
:JC =M002
|
|||
|
:
|
|||
|
:JU -FB166 POP OF STACK
|
|||
|
Name :POP
|
|||
|
:BEU
|
|||
|
:
|
|||
|
M002 :L FW 222
|
|||
|
:L FW 226
|
|||
|
:+F
|
|||
|
:L KF +1
|
|||
|
:-F
|
|||
|
:T FW 224
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
FB 166 = FB166 POP OF STACK from FW 200 17.11.92 hkt sp
|
|||
|
|
|||
|
Segment 3 DW'S VORBELEGEN
|
|||
|
|
|||
|
12.03.97 UR - (1) FALSCHER PARAMETER ANGEGEBEN
|
|||
|
|
|||
|
:
|
|||
|
M004 :L FW 224 ENDE ERREICHT ?
|
|||
|
:L FW 222
|
|||
|
:<F
|
|||
|
:JC =M001 JA -> BAUSTEINENDE
|
|||
|
: NEIN -> NAECHSTES DW BEARBEITEN
|
|||
|
:LW =DBDX (1)
|
|||
|
:L KS DX
|
|||
|
:!=F
|
|||
|
:JC =M002
|
|||
|
:
|
|||
|
:JU -FB176 STORE DW INDIR. +- DATENWORT BESCHREIBEN (DB)
|
|||
|
Name :TANS DW
|
|||
|
DB : FW 220 |
|
|||
|
DW : FW 222 |
|
|||
|
WERT : FW 228 |
|
|||
|
DBDX : KS DB +-
|
|||
|
:JU =M003
|
|||
|
:
|
|||
|
M002 :JU -FB176 STORE DW INDIR. +- DATENWORT BESCHREIBEN (DX)
|
|||
|
Name :TANS DW
|
|||
|
DB : FW 220 |
|
|||
|
DW : FW 222 |
|
|||
|
WERT : FW 228 |
|
|||
|
DBDX : KS DX +-
|
|||
|
FB 138 -FB138 RESERVE DWs C:ZONE10ST.S5D LEN=111
|
|||
|
Page 3
|
|||
|
:
|
|||
|
M003 :L FW 222 +- ZEIGER ERHOEHEN
|
|||
|
:L KF +1 |
|
|||
|
:+F |
|
|||
|
:T FW 222 +-
|
|||
|
:JU =M004
|
|||
|
:
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
FB 176 = FB176 STORE DW INDIR. sp
|
|||
|
|
|||
|
Segment 4
|
|||
|
:JU -FB166 POP OF STACK
|
|||
|
Name :POP
|
|||
|
:BE
|
|||
|
|
|||
|
FB 166 = FB166 POP OF STACK from FW 200 17.11.92 hkt sp
|
|||
|
|
|||
|
FB 139 -FB139 X OF N F/I/O C:ZONE10ST.S5D LEN=28
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
|
|||
|
|
|||
|
erstellt: Herkert 1988
|
|||
|
----------------------
|
|||
|
|
|||
|
|
|||
|
Parameter:
|
|||
|
|
|||
|
# ANF : Anfangsadresse einer Bitleiste im M,A,E - Bereich (byte-orientiert)
|
|||
|
# AUSG : Wort, in dem die errechnete Bitadresse im Format KY ausgegeben
|
|||
|
wird und durch einen 'BEARBEITE' - Befehl bearbeitet werden kann
|
|||
|
|
|||
|
Bsp: Abhaengig von einer Bedingung soll das 4-te Bit im Merkerberich
|
|||
|
ab M7.0 gesetzt werden
|
|||
|
-> M 7.3
|
|||
|
KY 3,7
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Programmaufruf:
|
|||
|
|
|||
|
L KF +4 Die Nummer wird vor FbB-Aufruf in Akku1 geladen
|
|||
|
SPA FB X-aus-N
|
|||
|
#ANF : 7
|
|||
|
#AUSG: MW 200
|
|||
|
U -Bedingung
|
|||
|
B MW 200
|
|||
|
= M0.0
|
|||
|
------------------------------------------------------------------------------
|
|||
|
|
|||
|
|
|||
|
Name :X AUS N
|
|||
|
Decl :ANF I/Q/D/B/T/C: D KM/KH/KY/KS/KF/KT/KC/KG: KF
|
|||
|
Decl :AUSG I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
|
|||
|
:D 1 BSP: AKKU = 4 --> 4-1 = 3
|
|||
|
:L KM 00000000 00000111
|
|||
|
:AW
|
|||
|
:SLW 8 03 00 H
|
|||
|
:TAK
|
|||
|
:SRW 3 SRW 3 = DIV 8
|
|||
|
:OW
|
|||
|
:LW =ANF
|
|||
|
:+F
|
|||
|
:T =AUSG
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 140 -FB140 16-BIT DUALMUL. C:ZONE10ST.S5D LEN=37
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
FB 140 FESTPUNKT MULTIPLIKATION
|
|||
|
===============================================================================
|
|||
|
***** CPU : 948 *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : 04.11.94 H.URBAN
|
|||
|
(UR)
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG : 1 XX.XX.XX XXXXXXXXXXX
|
|||
|
(XXX)
|
|||
|
----------------------------------------------------
|
|||
|
===============================================================================
|
|||
|
|
|||
|
SYMBOLIKDATEI :
|
|||
|
|
|||
|
BAUSTEINPARAMETER :
|
|||
|
-------------------
|
|||
|
#Z1 : FESTPUNKT ZAHL 1
|
|||
|
#Z2 : FESTPUNKT ZAHL 2
|
|||
|
#Z3=0 : ERGEBNIS = NULL
|
|||
|
#Z32 : ERGEBNIS FESTPUNKT ZAHL HIGH-WORD
|
|||
|
#Z31 : ERGEBNIS FESTPUNKT ZAHL LOW-WORD
|
|||
|
|
|||
|
LOKALE VARIABLEN :
|
|||
|
------------------
|
|||
|
KEINE
|
|||
|
|
|||
|
FUNKTION :
|
|||
|
----------
|
|||
|
BILDET DEN MULTIPLIKATIONS FB 'MUL:16' DER CPU 95U,115U NACH
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Name :MUL:16
|
|||
|
Decl :Z1 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :Z2 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :Z3=0 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :Z32 I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :Z31 I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
|
|||
|
:L =Z1
|
|||
|
:L =Z2
|
|||
|
:XF
|
|||
|
:L KF +0
|
|||
|
:!=F
|
|||
|
:= =Z3=0
|
|||
|
:TAK
|
|||
|
:T =Z31
|
|||
|
:SSD 16
|
|||
|
:T =Z32
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 141 -FB141 16-BIT DUALDIV. C:ZONE10ST.S5D LEN=57
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
FB 141 FESTPUNKT DIVISION
|
|||
|
===============================================================================
|
|||
|
***** CPU : 948 *****
|
|||
|
===============================================================================
|
|||
|
NR. DATUM BEARBEITER
|
|||
|
------------------------------------------------------
|
|||
|
ERSTELLT : 27.01.94 H.URBAN
|
|||
|
(UR)
|
|||
|
-------------------------------------------------------------
|
|||
|
LETZTE AENDERUNG : 1 XX.XX.XX XXXXXXXXXXX
|
|||
|
(XXX)
|
|||
|
----------------------------------------------------
|
|||
|
===============================================================================
|
|||
|
|
|||
|
SYMBOLIKDATEI :
|
|||
|
|
|||
|
BAUSTEINPARAMETER :
|
|||
|
-------------------
|
|||
|
#Z1 : FESTPUNKT ZAHL 1 (DIVIDEND)
|
|||
|
#Z2 : FESTPUNKT ZAHL 2 (DIVISOR)
|
|||
|
#OV : ERGEBNIS ZU GROSS
|
|||
|
#FEH : DIVISION DURCH NULL
|
|||
|
#Z3=0 : ERGEBNIS = NULL
|
|||
|
#Z4=0 : REST IST NULL
|
|||
|
#Z32 : ERGEBNIS FESTPUNKT ZAHL (QUOTIENT)
|
|||
|
#Z31 : ERGEBNIS FESTPUNKT ZAHL (REST)
|
|||
|
|
|||
|
LOKALE VARIABLEN :
|
|||
|
------------------
|
|||
|
KEINE
|
|||
|
|
|||
|
FUNKTION :
|
|||
|
----------
|
|||
|
BILDET DEN DIVISIONS FB 'DIV:16' DER CPU 95U,115U NACH
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Name :DIV:16
|
|||
|
Decl :Z1 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :Z2 I/Q/D/B/T/C: I BI/BY/W/D: W
|
|||
|
Decl :OV I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :FEH I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :Z3=0 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :Z4=0 I/Q/D/B/T/C: Q BI/BY/W/D: BI
|
|||
|
Decl :Z3 I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
Decl :Z4 I/Q/D/B/T/C: Q BI/BY/W/D: W
|
|||
|
|
|||
|
:L =Z1
|
|||
|
:L =Z2
|
|||
|
::F
|
|||
|
:T =Z3
|
|||
|
:SSD 16
|
|||
|
:T =Z4
|
|||
|
:
|
|||
|
:L =Z2
|
|||
|
:L KF +0
|
|||
|
:!=F
|
|||
|
:= =FEH
|
|||
|
:L =Z3
|
|||
|
:L KF +0
|
|||
|
:!=F
|
|||
|
:= =Z3=0
|
|||
|
FB 141 -FB141 16-BIT DUALDIV. C:ZONE10ST.S5D LEN=57
|
|||
|
Page 2
|
|||
|
:L =Z4
|
|||
|
:L KF +0
|
|||
|
:!=F
|
|||
|
:= =Z4=0
|
|||
|
:BE
|
|||
|
|
|||
|
|
|||
|
FB 142 -FB142 PRINT C:ZONE10ST.S5D LEN=465
|
|||
|
Page 1
|
|||
|
Segment 1
|
|||
|
|
|||
|
|
|||
|
FORMAT DES DATENBLOCKES AUS DEM FIFO
|
|||
|
====================================
|
|||
|
|
|||
|
|
|||
|
DW1 ZAHLENART
|
|||
|
DW2 SPALTE
|
|||
|
DW3 ZEILENART
|
|||
|
|
|||
|
DW4 ZEILE / ZEILENENDE / SPALTE / ART / BLOCKLAENGE
|
|||
|
#### # # ## ## ## ####
|
|||
|
0-32 0-1 0-15
|
|||
|
|
|||
|
DW5 NUTZ DW1
|
|||
|
DW6 NUTZ DW2
|
|||
|
|
|||
|
|
|||
|
|
|||
|
DW10 ZEIGER AUF FIFO
|
|||
|
DW11 ZEIGER AUF DRUCK - DB
|
|||
|
DW12 ZEIGER AUF GELESENEN BLOCK
|
|||
|
DW13 ZEIGER AUF ZEILE IN BEARBEITUNG
|
|||
|
DW14 ZEIGER AUF ZU DRUCKENDE ZEILE
|
|||
|
DW15 DB MIT ZEILENFORMULAREN
|
|||
|
DW16 ZEIGER AUF FORMULARE
|
|||
|
DW17 FORMULARLAENGE
|
|||
|
DW18 STEUERBITS AN DRUCKER
|
|||
|
D 18.0 = DRUCKER START
|
|||
|
DW19 STEUERBITS VON DRUCKER
|
|||
|
D 19.0 = DRUCKER FERTIG
|
|||
|
|
|||
|
DW20 PUFFER-DB FUER GLEITPUNKTWANDLUNG
|
|||
|
|
|||
|
DR21 = VORKOMMASTELLEN
|
|||
|
DL21 = NACHKOMMASTELLEN
|
|||
|
|
|||
|
DW22 ZEIGER AUF VARIABLE IN BEARBEITUNGSZEILE
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
DW40 ZEILE IN BEARBEITUNG
|
|||
|
|
|||
|
DW80 ZU DRUCKENDE ZEILE
|
|||
|
|
|||
|
DW120 ZEILENFORMULARE
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Name :DRUCK
|
|||
|
|
|||
|
:C -DB213 PRINT WORKING DB
|
|||
|
:
|
|||
|
:JU -FB177 LOAD DW DIREKT
|
|||
|
Name :LADE DW
|
|||
|
DB : KF +197
|
|||
|
DW : KF +84
|
|||
|
DBDX : KS DB
|
|||
|
:T DW 15
|
|||
|
:
|
|||
|
:JU -FB177 LOAD DW DIREKT
|
|||
|
Name :LADE DW
|
|||
|
FB 142 -FB142 PRINT C:ZONE10ST.S5D LEN=465
|
|||
|
Page 2
|
|||
|
DB : KF +197
|
|||
|
DW : KF +82
|
|||
|
DBDX : KS DB
|
|||
|
:T DW 11
|
|||
|
:
|
|||
|
:L KF +39
|
|||
|
:T DW 13
|
|||
|
:
|
|||
|
:L KF +80
|
|||
|
:T DW 14
|
|||
|
:
|
|||
|
:L KF +41
|
|||
|
:T DW 17
|
|||
|
:
|
|||
|
:JU -FB177 LOAD DW DIREKT
|
|||
|
Name :LADE DW
|
|||
|
DB : KF +197
|
|||
|
DW : KF +110
|
|||
|
DBDX : KS DB
|
|||
|
:T DW 20
|
|||
|
:
|
|||
|
:L KF +4
|
|||
|
:T DR 21
|
|||
|
:
|
|||
|
:L KF +3
|
|||
|
:T DL 21
|
|||
|
:
|
|||
|
:L DR 18
|
|||
|
:T FY 254
|
|||
|
:L DR 19
|
|||
|
:T FY 255
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T FY 200
|
|||
|
:***
|
|||
|
|
|||
|
|
|||
|
DB 213 = DB213 PRINT WORKING DB plc scale
|
|||
|
|
|||
|
FB 177 = FB177 LOAD DW DIREKT sp
|
|||
|
|
|||
|
Segment 2
|
|||
|
|
|||
|
|
|||
|
:O F 254.0
|
|||
|
:O F 255.0
|
|||
|
:JC =M001
|
|||
|
:L DW 10
|
|||
|
:L KF +0
|
|||
|
:><F
|
|||
|
:JC =M001
|
|||
|
:L KF +201
|
|||
|
:L DW 27
|
|||
|
:>F
|
|||
|
:JC =M002
|
|||
|
:
|
|||
|
:L KF +233
|
|||
|
:L DW 27
|
|||
|
:>F
|
|||
|
:I 1
|
|||
|
:JC =M003
|
|||
|
M002 :L KF +201
|
|||
|
M003 :T DW 27
|
|||
|
:
|
|||
|
FB 142 -FB142 PRINT C:ZONE10ST.S5D LEN=465
|
|||
|
Page 3
|
|||
|
:L KF +0
|
|||
|
:DO DW 27
|
|||
|
:L DW 0
|
|||
|
:!=F
|
|||
|
:JC =M001
|
|||
|
:T DW 10
|
|||
|
:L KF +0
|
|||
|
:T DW 30
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 3
|
|||
|
|
|||
|
|
|||
|
:L DW 10
|
|||
|
:L KF +0
|
|||
|
:!=F
|
|||
|
:O F 254.6
|
|||
|
:JC =M001
|
|||
|
:L KF +0
|
|||
|
:T DW 1
|
|||
|
:T DW 2
|
|||
|
:T DW 3
|
|||
|
:T DW 4
|
|||
|
:
|
|||
|
:L KF +4
|
|||
|
:T DW 12
|
|||
|
:
|
|||
|
:JU -FB161 FIFO 1..64
|
|||
|
Name :FIFO
|
|||
|
ART : KS RD
|
|||
|
F-DB : DW 10
|
|||
|
QTYP : KS 2.
|
|||
|
Q-DB : DW 12
|
|||
|
Q-DW : DW 0
|
|||
|
LAEN : F 200.0
|
|||
|
LEER : F 200.1
|
|||
|
VOLL : F 200.2
|
|||
|
GEL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
:
|
|||
|
:L KM 00000100 00000000
|
|||
|
:L DW 4
|
|||
|
:AW
|
|||
|
:!=F
|
|||
|
:= F 254.7
|
|||
|
:
|
|||
|
:O F 200.0
|
|||
|
:O F 254.7
|
|||
|
:= F 254.4
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
|
|||
|
FB 161 = FB161 FIFO 1..64 plc scale sp
|
|||
|
|
|||
|
Segment 4
|
|||
|
:AN F 200.2
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L DW 4
|
|||
|
:SRW 4
|
|||
|
:L KM 00000000 00000011
|
|||
|
:AW
|
|||
|
FB 142 -FB142 PRINT C:ZONE10ST.S5D LEN=465
|
|||
|
Page 4
|
|||
|
:T DW 1
|
|||
|
:
|
|||
|
:L DW 4
|
|||
|
:SRW 6
|
|||
|
:L KM 00000000 00001111
|
|||
|
:AW
|
|||
|
:T DW 2
|
|||
|
:
|
|||
|
:L DW 4
|
|||
|
:SRW 11
|
|||
|
:L KM 00000000 00011111
|
|||
|
:AW
|
|||
|
:T DW 3
|
|||
|
M001 :***
|
|||
|
|
|||
|
|
|||
|
Segment 5
|
|||
|
:AN F 200.2
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L KF +11
|
|||
|
:T DW 0
|
|||
|
:
|
|||
|
:JU -FB140 16-BIT DUALMUL.
|
|||
|
Name :MUL:16
|
|||
|
Z1 : DW 2
|
|||
|
Z2 : DW 0
|
|||
|
Z3=0 : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
Z32 : DW 0
|
|||
|
Z31 : DW 2
|
|||
|
:
|
|||
|
:L DW 2
|
|||
|
:L KF +6
|
|||
|
:-F
|
|||
|
:T DW 2
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
|
|||
|
FB 140 = FB140 16-BIT DUALMUL. plc scale 05.04.95 UR sp
|
|||
|
|
|||
|
Segment 6
|
|||
|
:L DW 3
|
|||
|
:L KF +0
|
|||
|
:!=F
|
|||
|
:ON F 254.5
|
|||
|
:AN F 254.4
|
|||
|
:AN F 254.6
|
|||
|
:JC =M001
|
|||
|
:S F 254.6
|
|||
|
:
|
|||
|
:O F 254.0
|
|||
|
:O F 255.0
|
|||
|
:JC =M001
|
|||
|
:R F 254.5
|
|||
|
:
|
|||
|
:L DW 30
|
|||
|
:I 1
|
|||
|
:T DW 30
|
|||
|
:
|
|||
|
:L KY 13,10
|
|||
|
:AN F 254.7
|
|||
|
:AN F 254.4
|
|||
|
:JC =M002
|
|||
|
FB 142 -FB142 PRINT C:ZONE10ST.S5D LEN=465
|
|||
|
Page 5
|
|||
|
:R F 254.7
|
|||
|
:R F 254.4
|
|||
|
:L KF +0
|
|||
|
:T DW 10
|
|||
|
:DO DW 27
|
|||
|
:T DW 0
|
|||
|
:L KY 13,12
|
|||
|
M002 :T DW 79
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DB
|
|||
|
DB-Q : DW 11
|
|||
|
VON : DW 13
|
|||
|
BIS : DW 17
|
|||
|
ZIEL : KS DB
|
|||
|
DB-Z : DW 11
|
|||
|
NACH : DW 14
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : DW 17
|
|||
|
L-B : KS LA
|
|||
|
:
|
|||
|
:A F 254.6
|
|||
|
:R F 254.6
|
|||
|
:AN F 254.0
|
|||
|
:S F 254.0
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
Segment 7
|
|||
|
|
|||
|
|
|||
|
:L DW 3
|
|||
|
:L KF +0
|
|||
|
:!=F
|
|||
|
:O F 254.6
|
|||
|
:JC =M001
|
|||
|
:S F 254.5
|
|||
|
:
|
|||
|
:L DW 17
|
|||
|
:D 1
|
|||
|
:T DW 17
|
|||
|
:
|
|||
|
:L DW 3
|
|||
|
:L KF +1
|
|||
|
:-F
|
|||
|
:T DW 23
|
|||
|
:
|
|||
|
:JU -FB140 16-BIT DUALMUL.
|
|||
|
Name :MUL:16
|
|||
|
Z1 : DW 17
|
|||
|
Z2 : DW 23
|
|||
|
Z3=0 : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
Z32 : DW 0
|
|||
|
Z31 : DW 16
|
|||
|
:L DW 16
|
|||
|
:L KF +0
|
|||
|
:+F
|
|||
|
:T DW 16
|
|||
|
:
|
|||
|
:JU -FB173 COPY BLOCK
|
|||
|
FB 142 -FB142 PRINT C:ZONE10ST.S5D LEN=465
|
|||
|
Page 6
|
|||
|
Name :COPY DKF
|
|||
|
QUEL : KS DB
|
|||
|
DB-Q : DW 15
|
|||
|
VON : DW 16
|
|||
|
BIS : DW 0
|
|||
|
ZIEL : KS DB
|
|||
|
DB-Z : DW 11
|
|||
|
NACH : DW 13
|
|||
|
FEHL : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
LAEN : DW 17
|
|||
|
L-B : KS LA
|
|||
|
:L DW 17
|
|||
|
:I 1
|
|||
|
:T DW 17
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T DW 3
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
|
|||
|
FB 140 = FB140 16-BIT DUALMUL. plc scale 05.04.95 UR sp
|
|||
|
FB 173 = FB173 COPY BLOCK parameter: EW sp
|
|||
|
|
|||
|
Segment 8
|
|||
|
|
|||
|
|
|||
|
:L DW 1
|
|||
|
:L KF +1
|
|||
|
:><F
|
|||
|
:O F 254.6
|
|||
|
:JC =M001
|
|||
|
:
|
|||
|
:L DW 2
|
|||
|
:SRW 1
|
|||
|
:L DW 13
|
|||
|
:+F
|
|||
|
:T DW 22
|
|||
|
:
|
|||
|
:L DW 5
|
|||
|
:T FW 200
|
|||
|
:L DW 6
|
|||
|
:T FW 202
|
|||
|
:L DW 20
|
|||
|
:T FW 204
|
|||
|
:L DR 21
|
|||
|
:T FY 206
|
|||
|
:L DL 21
|
|||
|
:T FY 207
|
|||
|
:L DW 11
|
|||
|
:T FW 208
|
|||
|
:L DW 22
|
|||
|
:T FW 210
|
|||
|
:AN -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
:S -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
:L FY 254
|
|||
|
:T DR 18
|
|||
|
:
|
|||
|
:JU -FB141 16-BIT DUALDIV.
|
|||
|
Name :DIV:16
|
|||
|
Z1 : FW 200
|
|||
|
Z2 : FW 202
|
|||
|
OV : FW 204
|
|||
|
FEH : -M 0.0 IND.ADDRES(DUMMY)
|
|||
|
FB 142 -FB142 PRINT C:ZONE10ST.S5D LEN=465
|
|||
|
Page 7
|
|||
|
Z3=0 : FY 206
|
|||
|
Z4=0 : FY 207
|
|||
|
Z3 : FW 208
|
|||
|
Z4 : FW 210
|
|||
|
:
|
|||
|
:L DR 18
|
|||
|
:T FY 254
|
|||
|
:
|
|||
|
:L KF +0
|
|||
|
:T DW 1
|
|||
|
M001 :***
|
|||
|
|
|||
|
F 0.0 = M 0.0 IND.ADDRES(DUMMY)
|
|||
|
|
|||
|
FB 141 = FB141 16-BIT DUALDIV. plc scale 05.04.95 UR sp
|
|||
|
|
|||
|
[1w
|