batch-example-2/document/equipment-modules/TA521_EP_OVERIDE_MAX_WEIGHT.md

4.0 KiB

TA521_EP_OVERIDE_MAX_WEIGHT

equipment module

unit: TA521

recipe phase: EP_OVERIDE_MAX_WEIGHT

property value
UniqueName TA521_EP_OVERIDE_MAX_WEIGHT
RecipePhase EP_OVERIDE_MAX_WEIGHT
EquipmentPhaseType TAGPHASE
UniqueID 41
MaxOwners 1
UploadDownloadFlags 2
CreateParameterLimitTag false
CreateReportLimitTag false
OnControlScanRate 1000
OffControlScanRate 60000

control

name id type engineering units Server Path Address opc
ControlTagRequest Request Integer InstructionBasedServer INSTRUCTIONS TA521_EP_OVERIDE_MAX_WEIGHT.RQ
ControlTagCommand Command Integer InstructionBasedServer INSTRUCTIONS TA521_EP_OVERIDE_MAX_WEIGHT.OC
ControlTagFailure Failure Integer InstructionBasedServer INSTRUCTIONS TA521_EP_OVERIDE_MAX_WEIGHT.F
ControlTagOwner Owner Integer InstructionBasedServer INSTRUCTIONS TA521_EP_OVERIDE_MAX_WEIGHT.W
ControlTagPause Pause Integer InstructionBasedServer INSTRUCTIONS TA521_EP_OVERIDE_MAX_WEIGHT.P
ControlTagPaused Paused Integer InstructionBasedServer INSTRUCTIONS TA521_EP_OVERIDE_MAX_WEIGHT.PD
ControlTagSingleStep SingleStep Integer InstructionBasedServer INSTRUCTIONS TA521_EP_OVERIDE_MAX_WEIGHT.SS
ControlTagStatus Status Integer InstructionBasedServer INSTRUCTIONS TA521_EP_OVERIDE_MAX_WEIGHT.ST
ControlTagStepIndex StepIndex Integer InstructionBasedServer INSTRUCTIONS TA521_EP_OVERIDE_MAX_WEIGHT.SI
ControlTagUnit Unit Integer InstructionBasedServer INSTRUCTIONS TA521_EP_OVERIDE_MAX_WEIGHT.UN

requests

name id type engineering units Server Path Address opc
REQUEST00 0 Integer InstructionBasedServer INSTRUCTIONS TA521_EP_OVERIDE_MAX_WEIGHT.Q01
REQUEST01 1 Integer InstructionBasedServer INSTRUCTIONS TA521_EP_OVERIDE_MAX_WEIGHT.Q02

parameters

name id type engineering units Server Path Address opc
CURRENT_WEIGHT 1 Real kg InstructionBasedServer INSTRUCTIONS TA521_EP_OVERIDE_MAX_WEIGHT.P01
MAX_EMPTY_WEIGHT 2 Real kg InstructionBasedServer INSTRUCTIONS TA521_EP_OVERIDE_MAX_WEIGHT.P02

reports

none

operations