batch-example-2/document/operations/HO580_SELF_CHECK_NB.md

6.6 KiB

HO580_SELF_CHECK_NB

operation

property value
AreaModel \DESKTOP-PKHILQE\BATCHCTL\ZONE-10\EQUIPMENT-MODEL.CFG
AreaModelDate 1950-02-28T00:00:00
Author D Clark
BeingEditedBy Not being handled yet
ClassBased false
DBSchema 3530
DefaultSize 0.
Description Self check operation for HO580 with direct transfer from HO561 (blender not used)
Duration 0
LocaleID -1
MaxSize 0.
MinSize 0.
ProductCode SC
RecipeType Operation
Released 0
ReleaseAsStep true
Resource HO580
VerificationDate 1950-02-28T00:00:00
Version 1.0
VersionDate 2023-10-16T14:46:49
Obsoleted false
NextWIPNumber 2
ParentVersionDate 1950-02-28T00:00:00
ParentVerificationDate 1950-02-28T00:00:00
ParentAreaModelDate 1950-02-28T00:00:00
SecurityAuthorityIdentifier NOT_AVAILABLE

parameters

Name PLCReference Type Default High Low EU Scale

reports

Name Type EU

steps

ACCUMULATOR:1

ACCUMULATOR

formula values

name type value defer EU
ADD Real 0
PROMPT String TURN HUMIDITY MONITORING OFF
RESET enumset YES YES_NO
USE_ACCUMULATOR enumset HUMIDITY_MONITORING ACCUMULATORS_ENUM

CHARGE:1

CHARGE

formula values

name type value defer EU
FINE_VALUE Real 0
HEEL Real 0
HEEL_TIME Integer 0
KIND_OF_DOSING enumset CONVEYING_ORDER_CONTROL_WEIGHING KIND_OF_DOSING
SPEED_COARSE Integer 670
SPEED_FINE Integer 950
SUB_ASSEMBLY Integer 1
TARGET_VALUE_DOSING_TIME Integer 30000
TOLERANCE Real 5
WEIGHT_TO_ADD Real 20

EP_PROMPT:1

EP_PROMPT

formula values

name type value defer EU
PROMPT String COVER IBC SENSOR

EP_PROMPT:2

EP_PROMPT

formula values

name type value defer EU
PROMPT String PLACE 20KG WEIGHT ON H0580

EP_PROMPT:3

EP_PROMPT

formula values

name type value defer EU
PROMPT String REMOVE WEIGHT FROM HO580 AND UNCOVER IBC SENSOR

PARTNER_RECEIVE:1

PARTNER_RECEIVE

formula values

name type value defer EU
REASON String

unit-procedures