DR540_HEAT

equipment module

unit: DR540

recipe phase: DRY

property value
UniqueName DR540_HEAT
RecipePhase DRY
EquipmentPhaseType TAGPHASE
UniqueID 215
MaxOwners 1
UploadDownloadFlags 1793
CreateParameterLimitTag false
CreateReportLimitTag false
OnControlScanRate 1000
OffControlScanRate 60000

control

name id type engineering units Server Path Address opc
ControlTagRequest Request Integer sigyl sigyl.dk400.phases DR540_HEAT.RQ N26:150
ControlTagCommand Command Integer sigyl sigyl.dk400.phases DR540_HEAT.OC N21:15
ControlTagFailure Failure Integer sigyl sigyl.dk400.phases DR540_HEAT.F N25:15
ControlTagOwner Owner Integer sigyl sigyl.dk400.phases DR540_HEAT.W N27:15/3
ControlTagPause Pause Integer sigyl sigyl.dk400.phases DR540_HEAT.P N27:15/4
ControlTagPaused Paused Integer sigyl sigyl.dk400.phases DR540_HEAT.PD N27:15/5
ControlTagSingleStep SingleStep Integer sigyl sigyl.dk400.phases DR540_HEAT.SS N27:15/2
ControlTagStatus Status Integer sigyl sigyl.dk400.phases DR540_HEAT.ST N24:15
ControlTagStepIndex StepIndex Integer sigyl sigyl.dk400.phases DR540_HEAT.SI N32:15
ControlTagUnit Unit Integer sigyl sigyl.dk400.phases DR540_HEAT.UN N23:15

requests

none

parameters

name id type engineering units Server Path Address opc
TEMPERATURE 1 Real DEGC sigyl sigyl.dk400.phases DR540_HEAT.P01 F103:10
PERCENTAGE 2 Integer % sigyl sigyl.dk400.phases DR540_HEAT.P02 N102:67
NUMBER_PULSES 3 Integer NONE sigyl sigyl.dk400.phases DR540_HEAT.P03 N102:68
MINS_TO_PULSE 4 Integer NONE sigyl sigyl.dk400.phases DR540_HEAT.P04 N102:69
HEAT_COOL 5 Enumeration sigyl sigyl.dk400.phases DR540_HEAT.P05 N102:70
OUTLET_TEMPERATURE 6 Integer DEGC sigyl sigyl.dk400.phases DR540_HEAT.P06 N102:71
STAGE_TIME 7 Integer MINUTES sigyl sigyl.dk400.phases DR540_HEAT.P07 N102:72
AIR_VOLUME 8 Real M3/HR sigyl sigyl.dk400.phases DR540_HEAT.P08 F103:11
FILTER_SHAKING_INTERVAL 9 Integer SECONDS sigyl sigyl.dk400.phases DR540_HEAT.P09 N102:161
FILTER_SHAKE_DURATION 10 Integer SECONDS sigyl sigyl.dk400.phases DR540_HEAT.P10 N102:162
AST_AIR 11 Integer % sigyl sigyl.dk400.phases DR540_HEAT.P11 N102:159
PULSE_CLOSED 12 Integer % sigyl sigyl.dk400.phases DR540_HEAT.P12 N102:160
RUN_ON_TIME 13 Integer SECONDS sigyl sigyl.dk400.phases DR540_HEAT.P13 N102:184

reports

name id type engineering units Server Path Address opc
ACTUAL_INLET_TEMPERATURE 1 Integer DEGC sigyl sigyl.dk400.phases DR540_HEAT.R01 N105:12
ACTUAL_OUTLET_TEMPERATURE 2 Integer DEGC sigyl sigyl.dk400.phases DR540_HEAT.R02 N105:13
ACTUAL_STAGE_TIME 3 Integer MINUTES sigyl sigyl.dk400.phases DR540_HEAT.R03 N105:14
AVERAGE_AIR_VOLUME 4 Real KG sigyl sigyl.dk400.phases DR540_HEAT.R04 F106:33

sequence

operations