batch-example-2/document/operations/DR540_LOD.md

10 KiB

DR540_LOD

operation

property value
AreaModel \DESKTOP-PKHILQE\BATCHCTL\ZONE-10\EQUIPMENT-MODEL.CFG
AreaModelDate 1950-02-28T00:00:00
Author GB
BeingEditedBy Not being handled yet
ClassBased false
DBSchema 3530
DefaultSize 0.
Duration 0
LocaleID -1
MaxSize 0.
MinSize 0.
ProductID Generic
RecipeType Operation
Released 0
ReleaseAsStep true
Resource DR540
VerificationDate 1950-02-28T00:00:00
Version 1.2
VersionDate 2023-05-15T12:48:10
Obsoleted false
NextWIPNumber 2
ParentVersionDate 1950-02-28T00:00:00
ParentVerificationDate 1950-02-28T00:00:00
ParentAreaModelDate 1950-02-28T00:00:00
SecurityAuthorityIdentifier NOT_AVAILABLE

parameters

Name PLCReference Type Default High Low EU Scale
DRY_TEMP 1 Real 0 100 0 DEGC false
DRY_TIME 1 Integer 0 100 0 MINUTES false
DRY_VOLUME 1 Real 0 10000 0 M3/HR false
LOD_TEMP 1 Real 0 100 0 DEGC false
LOD_TIME 1 Integer 0 100 0 MINUTES false
LOD_VOLUME 1 Real 0 10000 0 M3/HR false
MAX_LOD 1 Real 0 100 0 % false
MIN_LOD 1 Real 0 100 0 % false

reports

Name Type EU

steps

DRY:1

DRY

formula values

name type value defer EU
AIR_VOLUME Real LOD_VOLUME M3/HR
AST_AIR Integer 0
FILTER_SHAKE_DURATION Integer 2
FILTER_SHAKING_INTERVAL Integer 500
HEAT_COOL enumset NEITHER HEAT_COOL
MINS_TO_PULSE Integer 0
NUMBER_PULSES Integer 0
OUTLET_TEMPERATURE Integer 0
PERCENTAGE Integer 100
PULSE_CLOSED Integer 0
RUN_ON_TIME Integer 0
STAGE_TIME Integer LOD_TIME MINUTES
TEMPERATURE Real LOD_TEMP DEGC

DRY:2

DRY

formula values

name type value defer EU
AIR_VOLUME Real 2000
AST_AIR Integer 0
FILTER_SHAKE_DURATION Integer 0
FILTER_SHAKING_INTERVAL Integer 0
HEAT_COOL enumset NEITHER HEAT_COOL
MINS_TO_PULSE Integer 0
NUMBER_PULSES Integer 0
OUTLET_TEMPERATURE Integer 0
PERCENTAGE Integer 100
PULSE_CLOSED Integer 0
RUN_ON_TIME Integer 0
STAGE_TIME Integer 1
TEMPERATURE Real 30

DRY:3

DRY

formula values

name type value defer EU
AIR_VOLUME Real DRY_VOLUME M3/HR
AST_AIR Integer 0
FILTER_SHAKE_DURATION Integer 2
FILTER_SHAKING_INTERVAL Integer 180
HEAT_COOL enumset NEITHER HEAT_COOL
MINS_TO_PULSE Integer 0
NUMBER_PULSES Integer 0
OUTLET_TEMPERATURE Integer 0
PERCENTAGE Integer 100
PULSE_CLOSED Integer 0
RUN_ON_TIME Integer 60
STAGE_TIME Integer DRY_TIME MINUTES
TEMPERATURE Real DRY_TEMP DEGC

EP_LOD:1

EP_LOD

formula values

name type value defer EU
MAX_LOD Real MAX_LOD %
MIN_LOD Real MIN_LOD %

EP_LOD_REMINDER:1

EP_LOD_REMINDER

formula values

name type value defer EU

unit-procedures